Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(3)2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36772600

RESUMO

Industrial Control Systems (ICSs) were initially designed to be operated in an isolated network. However, recently, ICSs have been increasingly connected to the Internet to expand their capability, such as remote management. This interconnectivity of ICSs exposes them to cyber-attacks. At the same time, cyber-attacks in ICS networks are different compared to traditional Information Technology (IT) networks. Cyber attacks on ICSs usually involve a sequence of actions and a multitude of devices. However, current anomaly detection systems only focus on local analysis, which misses the correlation between devices and the progress of attacks over time. As a consequence, they lack an effective way to detect attacks at an entire network scale and predict possible future actions of an attack, which is of significant interest to security analysts to identify the weaknesses of their network and prevent similar attacks in the future. To address these two key issues, this paper presents a system-wide anomaly detection solution using recurrent neural networks combined with correlation analysis techniques. The proposed solution has a two-layer analysis. The first layer targets attack detection, and the second layer analyses the detected attack to predict the next possible attack actions. The main contribution of this paper is the proof of the concept implementation using two real-world ICS datasets, SWaT and Power System Attack. Moreover, we show that the proposed solution effectively detects anomalies and attacks on the scale of the entire ICS network.

2.
Sensors (Basel) ; 21(20)2021 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-34696053

RESUMO

Internet of Things (IoT) applications and services are becoming more prevalent in our everyday life. However, such an interconnected network of intelligent physical entities needs appropriate security to sensitive information. That said, the need for proper authentication and authorization is paramount. Access control is in the front line of such mechanisms. Access control determines the use of resources only to the specified and authorized users based on appropriate policy enforcement. IoT demands more sophisticated access control in terms of its usability and efficiency in protecting sensitive information. This conveys the need for access control to serve system-specific requirements and be flexibly combined with other access control approaches. In this paper, we discuss the potential for employing protocol-based and hybrid access control for IoT systems and examine how that can overcome the limitations of traditional access control mechanisms. We also focus on the key benefits and constraints of this integration. Our work further enhances the need to build hierarchical access control for large-scale IoT systems (e.g., Industrial IoT (IIoT) settings) with protocol-based and hybrid access control approaches. We, moreover, list the associated open issues to make such approaches efficient for access control in large-scale IoT systems.

3.
J Appl Oral Sci ; 20(3): 352-6, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22858703

RESUMO

OBJECTIVES: The objective of this one-year clinical study was to investigate the effect of two adhesive systems (Adper Single Bond, a two-step etch-and-rinse and Clearfil SE Bond, a two-step self-etch system) on pit-and-fissure sealant retention in newly-erupted teeth. This study compared the success of the sealants in mesial and distopalatal grooves with and without these two adhesive systems. MATERIAL AND METHODS: In a clinical trial, 35 children aged 6-8 years undergoing sealant placement were recruited. This one-year clinical study scored 70 mesial and 70 distopalatal sealants of newly-erupted permanent maxillary first molar, with a split-mouth design. All children received sealant alone in one permanent maxillary molar tooth. Children were randomized into two groups. One group received Self-etch (Se) bond plus sealant and the other group received Single Bond plus sealant in another permanent maxillary molar tooth. Clinical evaluation at 3, 6 and 12 months was performed and the retention was studied in terms of the success and failure. RESULTS: The success rate of sealant in the distopalatal groove, using SeB at 3, 6 and 12 months was 93.3% (95% CI: 68.0, 99.8), 73.3% (95% CI: 44.9, 92.2) and 66.7% (95% CI: 38.4, 88.2), respectively. It was greater than that of the distopalatal groove in SB group with a success rate of 62.5% (95% CI: 35.4, 84.8), 31.3% (95% CI: 11.8, 58.7) and 31.3% (95% CI: 11.8, 58.7), at the three evaluation periods. The success rate of sealant in the mesial groove using SeB was 86.6% (95% CI: 59.5, 98.3), 53.3% (95% CI: 26.6, 78.7) and 53.3% (95% CI: 26.6, 78.7), while this was 100% (95% CI: 79.4, 100.0), 81.3% (95% CI: 54.4, 96.0) and 81.3% (95% CI: 54.4, 96.0) using SB, at 3, 6 and 12-month evaluation periods. CONCLUSIONS: These results support the use of these two bonding agents in pit-and-fissure sealants under both isolated and contaminated conditions. Further, Se bond seemed to be less sensitive to moisture contamination.


Assuntos
Colagem Dentária/métodos , Cimentos Dentários/química , Selantes de Fossas e Fissuras/química , Erupção Dentária/efeitos dos fármacos , Bis-Fenol A-Glicidil Metacrilato/química , Bis-Fenol A-Glicidil Metacrilato/uso terapêutico , Distribuição de Qui-Quadrado , Criança , Cimentos Dentários/uso terapêutico , Feminino , Seguimentos , Humanos , Masculino , Selantes de Fossas e Fissuras/uso terapêutico , Cimentos de Resina/química , Cimentos de Resina/uso terapêutico , Propriedades de Superfície , Fatores de Tempo , Resultado do Tratamento
4.
J. appl. oral sci ; 20(3): 352-356, May-June 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-643733

RESUMO

OBJECTIVES: The objective of this one-year clinical study was to investigate the effect of two adhesive systems (Adper Single Bond, a two-step etch-and-rinse and Clearfil SE Bond, a two-step self-etch system) on pit-and-fissure sealant retention in newly-erupted teeth. This study compared the success of the sealants in mesial and distopalatal grooves with and without these two adhesive systems. MATERIAL AND METHODS: In a clinical trial, 35 children aged 6-8 years undergoing sealant placement were recruited. This one-year clinical study scored 70 mesial and 70 distopalatal sealants of newly-erupted permanent maxillary first molar, with a split-mouth design. All children received sealant alone in one permanent maxillary molar tooth. Children were randomized into two groups. One group received Self-etch (Se) bond plus sealant and the other group received Single Bond plus sealant in another permanent maxillary molar tooth. Clinical evaluation at 3, 6 and 12 months was performed and the retention was studied in terms of the success and failure. RESULTS: The success rate of sealant in the distopalatal groove, using SeB at 3, 6 and 12 months was 93.3% (95% CI: 68.0, 99.8), 73.3% (95% CI: 44.9, 92.2) and 66.7% (95% CI: 38.4, 88.2), respectively. It was greater than that of the distopalatal groove in SB group with a success rate of 62.5% (95% CI: 35.4, 84.8), 31.3% (95% CI: 11.8, 58.7) and 31.3% (95% CI: 11.8, 58.7), at the three evaluation periods. The success rate of sealant in the mesial groove using SeB was 86.6% (95% CI: 59.5, 98.3), 53.3% (95% CI: 26.6, 78.7) and 53.3% (95% CI: 26.6, 78.7), while this was 100% (95% CI: 79.4, 100.0), 81.3% (95% CI: 54.4, 96.0) and 81.3% (95% CI: 54.4, 96.0) using SB, at 3, 6 and 12-month evaluation periods. CONCLUSIONS: These results support the use of these two bonding agents in pit-and-fissure sealants under both isolated and contaminated conditions. Further, Se bond seemed to be less sensitive to moisture contamination.


Assuntos
Criança , Feminino , Humanos , Colagem Dentária/métodos , Cimentos Dentários/química , Selantes de Fossas e Fissuras/química , Erupção Dentária/efeitos dos fármacos , Bis-Fenol A-Glicidil Metacrilato/química , Bis-Fenol A-Glicidil Metacrilato/uso terapêutico , Distribuição de Qui-Quadrado , Cimentos Dentários/uso terapêutico , Seguimentos , Selantes de Fossas e Fissuras/uso terapêutico , Cimentos de Resina/química , Cimentos de Resina/uso terapêutico , Propriedades de Superfície , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...