Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Dent ; 19: 8, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35937153

RESUMO

Objectives: The aim of this study was to assess the microtensile bond strength of three universal adhesives to dentin and enamel. Materials and Methods: Sixty extracted human third molar teeth were chosen and divided into six groups regarding the adhesive (G-Premio Bond, Clearfil S3 Bond or Single Bond) and tooth surface. All the applied bonding agents were universal adhesives. The teeth were polished and the adhesives were applied; then the teeth were restored with composite resin. The samples were mounted in acrylic resin and sectioned. The specimens were subjected to a universal testing machine and the microtensile bond strength was measured. The failure mode of each specimen was determined under a stereomicroscope. Data were analyzed using two-way ANOVA (α=0.05). Results: The microtensile bond strength of G-Premio Bond to enamel and dentin was 11.79±8.27 and 17.55±9.47 MPa, respectively which was not significantly different from the values in Single Bond group (15.59±10.66 and 17.19±10.09 MPa to enamel and dentin, respectively; P>0.05). However, the values for Clearfil S3 Bond were 7.11±4.23 and 7.88±8.83 MPa to enamel and dentin, respectively, which were significantly lower than the values for G-Premio Bond (P<0.05). Scanning electron microscopic (SEM) images showed that the adhesive failure was dominant in both enamel and dentin groups and in all adhesive systems. Conclusion: G-Premio Bond and Single Bond provided higher microtensile bond strength compared with Clearfil S3 Bond. Universal adhesives with their acceptable performance can be applied in self-etch mode on both enamel and dentin.

2.
Polim Med ; 52(1): 13-18, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35801996

RESUMO

BACKGROUND: Resin composites have various applications. At the same time, they have some drawbacks, such as polymerization shrinkage. Conventional composites are polymerized in 2-mm thick layers. However, in posterior restoration, the 2-mm depth of cure is not satisfactory. To find a solution, resin composites have been vastly improved in terms of fillers, matrix and initiators. OBJECTIVES: To evaluate polymerization properties and physical characteristics of fiber-reinforced composites and compare them with bulk-fill composites that are designed for large posterior restorations. MATERIAL AND METHODS: Samples were prepared from each resin composite. The 3-point bending test was performed to evaluate the flexural strength of all composites. The depth of cure of the composite from 1 mm to 4 mm of depth was analyzed using Vickers hardness test (VHN). To analyze the degree of conversion, Fourier-transform infrared spectroscopy (FTIR) of the top and bottom surfaces of the samples with 4-mm thickness was calculated. The data were analyzed using one-way analysis of variance (ANOVA) test followed by post hoc test (95% confidence interval (95% CI)). RESULTS: The Filtek showed the highest flexural strength followed by everX and X-tra fil. At 1-mm depth, X-tra fil had the highest and Gradia had the lowest microhardness. At the 4-mm depth, the microhardness trend was as follows: everX > Filtek > X-tra fil > Gradia > Beautifil. The everX composite had the lowest reduction of the degree of conversion at 4-mm thickness, which showed a significant difference in comparison with Filtek, Gradia and X-tra fil composites. CONCLUSIONS: Based on the results of our study, it can be concluded that the fiber-reinforced composite everX showed more favorable results regarding polymerization properties, such as the degree of conversion and the depth of cure. However, the flexural strength results in Filtek were better than those in everX.


Assuntos
Resinas Compostas , Materiais Dentários , Resinas Compostas/química , Dureza , Testes de Dureza , Teste de Materiais , Polimerização , Espectroscopia de Infravermelho com Transformada de Fourier , Propriedades de Superfície
3.
Dent Mater J ; 40(4): 870-876, 2021 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-33692225

RESUMO

Yttria doped ZrO2 was deposited using an acidic zinc phosphatizing solution and the hydrothermal treatment. The coating was analyzed using a field emission-scanning electron microscope (FE-SEM), X-ray diffraction (XRD), energy-dispersive X-ray spectroscopy (EDX) and X-ray photoelectron spectroscopy (XPS). A piston on three balls (ISO 6872) was used for the measurement of biaxial flexural strength. MC3T3-E1 cells attachment was evaluated by SEM, and cell proliferation were assessed using MTS assay™. SEM images confirmed that the zinc phosphate coating layer was successfully prepared and fully covered the surface. The measured adhesive strength of the coating was 79.11 MPa. In vitro cell study indicated that the coated sample had better cell morphology and proliferation. XRD and EDS analysis revealed that the crystalline coating structure indexed as zinc phosphate (hopeite) and the substrate was assigned as zirconia. The flexural strength test showed that the strength of zirconia before and after hydrothermal treatment was not affected.


Assuntos
Zinco , Zircônio , Teste de Materiais , Propriedades de Superfície , Difração de Raios X
4.
Dent Mater J ; 40(4): 949-956, 2021 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-33716277

RESUMO

This study aimed to assess the mechanical and biological properties of bioactive glass (BG) coating on titanium (Ti). Bioinert Ti substrates were coated by BG to induce bioactivity to the surface. The sol-gel derived BG 58S sol was successfully prepared and coated on the abraded and blasted Ti surface using the sol-dip method. The characterization and cell study for all substrates' surface was carried out. Adhesion test confirmed that a firmly adhered BG coating layer was formed on the abraded and blasted Ti. The measured bonding strength between the coating and the blasted Ti substrate was the highest among all samples, which was 41.03±2.31 MPa. In-vitro cell viability and alkaline phosphatase activity (ALP) tests results also showed that BG coating on the Ti substrate improved the biological properties of the surface. The BG sol-dip coating method could be used to fabricate Ti substrate with a bioactive surface.


Assuntos
Materiais Revestidos Biocompatíveis , Titânio , Propriedades de Superfície
5.
J Oral Sci ; 63(2): 148-151, 2021 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-33504755

RESUMO

PURPOSE: The objective of this study was to evaluate the physical and mechanical properties of a short fiber-reinforced resin composite: everX-Posterior and compare it with two bulk-fill composites, namely, Filtek Bulk-fill and Beautifil-Bulk, which are intended for large posterior restorations. METHODS: Investigated properties were flexural strength, flexural modulus, surface roughness, volumetric shrinkage and depth of cure. Scanning electron microscopy images of each specimen after the flexural test were used for cross-sectional comparison. Results were analyzed using ANOVA following Tukey post-hoc test. RESULTS: Flexural strength of everX-Posterior was comparable with two other resin composites, showing higher flexural modulus. EverX-Posterior showed the highest surface roughness after polishing and the lowest volumetric shrinkage (2.29%) among all composites used in this study. Data also showed that the everX-Posterior depth of cure was 4.24 mm, which was the highest among the three groups. CONCLUSION: Based on the results of this study, it was concluded that everX-Posterior as a short fiber-reinforced composite showed improvements and satisfactory performance in mechanical and physical properties, which make it a reliable base material candidate for large posterior restorations.


Assuntos
Resinas Compostas , Materiais Dentários , Estudos Transversais , Teste de Materiais , Propriedades de Superfície
6.
J Clin Exp Dent ; 9(3): e372-e376, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28298977

RESUMO

BACKGROUND: Recently, incorporation of nanohydroxyapatite (NHA) has been suggested to improve the mechanical properties of glass ionomers (GIs). This study aimed to assess the effect of addition of NHA on wear of resin modified glass ionomer (RMGI) by tooth brushing simulation. MATERIAL AND METHODS: In this in vitro, experimental study, NHA in 1, 2, 5, 7 and 10wt% concentrations was added to Fuji II LC RMGI powder, and 48 samples (5×5mm) in five experimental and one control group (n=8) were fabricated. After polishing, cleaning and incubation at 37°C for three weeks, the samples were weighed and subjected to tooth brushing simulation in a toothpaste slurry according to ISO14569-1. Then, they were weighed again and the weight loss was calculated. The data were analyzed using one-way ANOVA and Tukey's test. RESULTS: The highest and the lowest weight loss was found in the 0% NHA (-1.052±0.176) and 5% NHA (-0.370±0.143) groups, respectively. Wear was significantly higher in 0% NHA group (P<0.05). No difference was detected in wear between 2 and 5wt% NHA or among 1, 7 and 10wt% NHA groups. Significant differences were noted in wear between 2 and 5wt% NHA and 1, 7 and 10wt% NHA groups (P<0.001). CONCLUSIONS: Incorporation of up to 10wt% of NHA increases the wear resistance of Fuji II LC RMGI. This increase was the highest when 2 and 5wt% NHA were added. Key words:Glass ionomer, hydroxyapatites, nanoparticles, dental restoration wear.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...