Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ultrasound Med Biol ; 46(11): 2956-2964, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32863063

RESUMO

The aim of this study is to assess the additional benefit of contrast-enhanced ultrasound (CEUS) over conventional ultrasonography (US) in identifying intra-testicular abnormalities among observers of different experiences. In this study, 91 focal testicular lesions (46 neoplastic, 45 non-neoplastic) imaged with gray-scale US/Doppler US and CEUS were classified using a 5-point scale. Three experienced and four inexperienced observers rated each lesion using gray-scale/color Doppler US alone and then with the addition of CEUS. Improved diagnostic specificity and accuracy with the addition of CEUS was observed for both experienced (specificity: 71.1% vs. 59.3%, p = 0.005; accuracy: 83.5% vs. 76.9%, p = 0.003) and inexperienced observers (specificity: 75.6% vs. 51.7%, p = 0.005; accuracy: 80.2% vs. 72.0%, p < 0.001). Significant inter-observer variability between the experienced and inexperienced observers when assessing conventional US alone was eliminated with the addition of CEUS. CEUS improves diagnostic accuracy of focal intra-testicular lesions for both experienced and inexperienced observers and reduces inter-observer variability in inexperienced operators.


Assuntos
Meios de Contraste , Doenças Testiculares/diagnóstico por imagem , Neoplasias Testiculares/irrigação sanguínea , Neoplasias Testiculares/diagnóstico por imagem , Testículo/irrigação sanguínea , Testículo/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Retrospectivos , Ultrassonografia/métodos , Adulto Jovem
2.
Radiology ; 287(3): 844-852, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29514018

RESUMO

Purpose To identify the minimum number of measurements required for the noninvasive assessment of liver fibrosis by using point shear-wave elastography (pSWE) and determine whether the use of a reliability indicator such as interquartile range [IQR]-to-median ratio will affect diagnostic performance. Materials and Methods Ten liver shear-wave velocity (SWV) measurements by pSWE were obtained in 232 participants. Interclass correlation coefficients (ICC) between the median of the first two through the first nine measurements and all 10 measurements were calculated; the minimum number of measurements with ICC greater than 0.95 versus all 10 measurements was determined. The diagnostic performance of the minimum number of measurements and 10 measurements in identifying significant (Ishak stage, ≥3) and severe fibrosis or cirrhosis (Ishak stage, ≥5) was compared by using areas under the receiver operating characteristic curve. These were compared between measurements that demonstrated higher or lower reliability (IQR-to-median ratio of ≤ 30% and IQR-to-median ratio of > 30%, respectively). Results Compared with 10 measurements, a minimum of six SWV measurements was required. The overall area under the curve for diagnosing significant (areas under the receiver operating characteristic curve, 0.828 vs 0.839; P = .487) and severe fibrosis or cirrhosis (0.953 vs 0.969, respectively; P = .145) did not differ according to number of measurements (six vs 10); a median of six measurements resulted in only limited disagreement (nine of 232 [3.9%]) versus histologic evaluation. When using 10 measurements, higher reliability measurements showed a lower percentage of discordance between pSWE and significant fibrosis and severe fibrosis or cirrhosis (22 [14.7%] and three [2.0%] of 150 cases, respectively) compared with lower reliability measurements (26 [31.7%] and eight [9.8%] of 82 cases, respectively). Significant fibrosis was an independent predictor for lower reliability (hazard ratio, 2.22; P < .020). Conclusion A limited number of SWV measurements (median six vs median 10) were required for the assessment of liver fibrosis by using pSWE. The number of measurements had less influence on the diagnostic accuracy compared with lower reliability measurements. © RSNA, 2018 Online supplemental material is available for this article.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Cirrose Hepática/diagnóstico por imagem , Adolescente , Adulto , Idoso , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/patologia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Adulto Jovem
3.
J Clin Imaging Sci ; 3: 22, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23814694

RESUMO

The von Meyenburg complex (VMC) is an uncommon congenital malformation and is characterized by benign bile duct hamartomas. These are usually discovered incidentally and may represent a diagnostic dilemma when liver metastases are suspected. MRI of VMC shows distinct imaging characteristics, but reporting of lesional contrast enhancement has been inconsistent, whilst microbubble contrast enhanced ultrasound provides 'real-time' evaluation of soft tissue vascularity. Given the diagnostic uncertainty over imaging in VMC, biopsy is often recommended as the definitive diagnosis. We report a biopsy proven case of VMC on a background of primary colonic malignancy investigated with ultrasound, contrast enhanced ultrasound, computed tomography CT, and magnetic resonance imaging MRI, and review the key imaging features.

4.
AJR Am J Roentgenol ; 199(3): W345-54, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22915425

RESUMO

OBJECTIVE: The purpose of this study is to determine the effectiveness of contrast-enhanced ultrasound in evaluating incidental focal testicular lesions in epididymitis. MATERIALS AND METHODS: Intratesticular lesions ipsilateral to epididymitis were subject to B-mode color Doppler ultrasound and contrast-enhanced ultrasound, with their appearances reviewed in consensus. Final interpretation was by histologic analysis or follow-up ultrasound. RESULTS: Over 28 months, 16 focal testicular lesions (median lesion size, 24 mm; range, 14-48 mm) in 14 patients (median age, 49 years; range, 18-81 years) were examined. Lesions were oval (n = 14), wedge shaped (n = 1), or involved the entire testis (n = 1). Lesions were isoechoic (n = 1), hypoechoic (n = 4), or of mixed echogenicity (n = 11). Color Doppler ultrasound flow was not clearly depicted in 13 lesions but was present in three lesions, with contrast-enhanced ultrasound concordant with color Doppler ultrasound, showing unequivocal absence of vascularity and increased flow, respectively. In the avascular lesions, rim enhancement (n = 6), vascular projections (n = 4), and irregular (n = 10) and smooth (n = 2) borders were documented. The observers identified infarction (n = 9), abscess (n = 4), orchitis (n = 1), and tumor (n = 2). Histologic examination (seven lesions in five patients) confirmed infarction, abscess formation, and seminoma; follow-up ultrasound confirmed resolution for eight patients. CONCLUSION: Contrast-enhanced ultrasound is a useful adjuvant to color Doppler ultrasound examination of a focal lesion in the testis ipsilateral to epididymitis to improve the characterization of nonvascularized tissue.


Assuntos
Meios de Contraste , Epididimite/complicações , Fosfolipídeos , Hexafluoreto de Enxofre , Doenças Testiculares/diagnóstico por imagem , Abscesso/diagnóstico por imagem , Abscesso/etiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Infarto/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Doenças Testiculares/etiologia , Neoplasias Testiculares/diagnóstico por imagem , Neoplasias Testiculares/etiologia , Testículo/irrigação sanguínea , Ultrassonografia Doppler em Cores , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...