Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 126
Filtrar
1.
Heliyon ; 10(9): e30265, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38726196

RESUMO

Antimicrobial residues in animal-derived foods have become a major source of concern around the world. Oxytetracycline (OTC), one of these antibiotics that belongs to the tetracycline family should be detected in these matrices. Nanostructured metal oxides have attracted a lot of scientific attention due to their special characteristics that can be exploited for creating innovative nanodevices. Therefore, in the present study, we report the fabrication of cobalt-doped ZnO/GO nanocomposites for OTC sensors using a simple and environmentally friendly method that does not require toxic solvents. Contact angle measurements, X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and UV-Vis were used to confirm the successful fabrication of the Co-ZnO/GO nanocomposite and to determine the surface area, Structural, morphological features, chemical composition and purity of the nanocomposite. The electrochemical and electrocatalytic properties were recorded using cyclic voltammetry (CV), electrochemical impedance spectroscopy, and differential pulse voltammetry (DPV). Optimizing parameters such as scan rate, pH value, deposition time, and deposition potential, we achieve a wide linear concentration range from 10-12 M to 10-7 M, with an impressive detection limit of 1.6 10-13 M.Notably, our sensor exhibits remarkable selectivity, demonstrating its usefulness for the detection of oxytetracycline traces in real milk samples. These results emphasize the novelty and practical significance of our work and provide a promising avenue for the development of sensitive and selective electrochemical sensing platforms in various fields.

2.
Colloids Surf B Biointerfaces ; 239: 113902, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38599037

RESUMO

CD146, also known as melanoma cell adhesion molecule (MCAM), is overexpressed in various cancer patients, making it a valuable predictor for early diagnosis. In this work, an immune sandwich electrochemical biosensor is proposed for sensitive and non-invasive quantitative detection of CD146 in serum. Zirconium-based MOF (UIO-66) was modified by simultaneous copper atom doping, in situ growth carbon-based support and physical embedding of platinum nanoparticles (PtNPs). Triple-modified Cu-UIO-66@SWCNT/PtNPs nanocomposites with high stability and excellent electrochemical properties, serve as surface modification materials for glassy carbon electrodes. Anti-CD146 antibody (Ab1) was grafted onto the electrode surface via Pt-S bond. Meanwhile, the secondary antibody (Ab2) was conjugated with silver nanoparticles (AgNPs) to cooperate for CD146 capture and achieve secondary electrical signal amplification. Under optimal conditions, square wave voltammetry was employed to determine CD146 in the concentration range of 10-9-10-4 mg/mL and a limit of detection of 12 fg/mL was obtained. Finally, it was successfully applied to the analysis of CD146 in lung and liver cancer patients' serum samples.


Assuntos
Técnicas Biossensoriais , Antígeno CD146 , Técnicas Eletroquímicas , Zircônio , Antígeno CD146/sangue , Humanos , Zircônio/química , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Nanopartículas Metálicas/química , Eletrodos , Prata/química , Platina/química , Neoplasias Pulmonares/sangue , Neoplasias Pulmonares/diagnóstico , Limite de Detecção , Nanotubos de Carbono/química , Neoplasias Hepáticas/sangue , Neoplasias Hepáticas/diagnóstico
3.
Micromachines (Basel) ; 15(3)2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38542544

RESUMO

We propose a new strategy using a sandwich approach for the detection of two HF biomarkers: tumor necrosis factor-α (TNF-α) and interleukin-10 (IL-10). For this purpose, magnetic nanoparticles (MNPs) (MNPs@aminodextran) were biofunctionalized with monoclonal antibodies (mAbs) using bis (sulfosuccinimidyl) suberate (BS3) as a cross-linker for the pre-concentration of two biomarkers (TNF-α and IL-10). In addition, our ISFETs were biofunctionalized with polyclonal antibodies (pAbs) (TNF-α and IL-10). The biorecognition between pAbs immobilized on the ISFET and the pre-concentrate antigen (Ag) on MNPs was monitored using electrochemical impedance spectroscopy (EIS). Our developed ImmunoFET showed a low detection limit (0.03 pg/mL) toward our target analyte when compared to previously published electrochemical immunosensors. It showed a higher sensitivity than for other HF biomarkers. Finally, the standard addition method was used to determine the unknown concentration in artificial saliva. The results matched with the expected values well.

4.
ACS Sens ; 8(10): 3623-3642, 2023 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-37819690

RESUMO

Over the past few decades, pathogens have posed a threat to human security, and rapid identification of pathogens should be one of the ideal methods to prevent major public health security outbreaks. Therefore, there is an urgent need for highly sensitive and specific approaches to identify and quantify pathogens. Clustered Regularly Interspaced Short Palindromic Repeats CRISPR/Cas systems and Argonaute (Ago) belong to the Microbial Defense Systems (MDS). The guided, programmable, and targeted activation of nucleases by both of them is leading the way to a new generation of pathogens detection. We compare these two nucleases in terms of similarities and differences. In addition, we discuss future challenges and prospects for the development of the CRISPR/Cas systems and Argonaute (Ago) biosensors, especially electrochemical biosensors. This review is expected to afford researchers entering this multidisciplinary field useful guidance and to provide inspiration for the development of more innovative electrochemical biosensors for pathogens detection.


Assuntos
Técnicas Biossensoriais , Sistemas CRISPR-Cas , Humanos
5.
Nanomaterials (Basel) ; 13(16)2023 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-37630900

RESUMO

In this paper, a microconductometric sensor has been designed, based on a chitosan composite including alcohol dehydrogenase-and its cofactor-and gold nanoparticles, and was calibrated by differential measurements in the headspace of aqueous solutions of ethanol. The role of gold nanoparticles (GNPs) was crucial in improving the analytical performance of the ethanol sensor in terms of response time, sensitivity, selectivity, and reproducibility. The response time was reduced to 10 s, compared to 21 s without GNPs. The sensitivity was 416 µS/cm (v/v%)-1 which is 11.3 times higher than without GNPs. The selectivity factor versus methanol was 8.3, three times higher than without GNPs. The relative standard deviation (RSD) obtained with the same sensor was 2%, whereas it was found to be 12% without GNPs. When the air from the operator's mouth was analyzed just after rinsing with an antiseptic mouthwash, the ethanol content was very high (3.5 v/v%). The background level was reached only after rinsing with water.

6.
Talanta ; 265: 124784, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37356191

RESUMO

We aim to develop an electrochemical sensor for a divalent metal ion (lead II), a highly toxic water contaminant. We explore a sensor formed with a hemicellulose polysaccharide extracted from the Opuntia Ficus Indica cactus associated with agarose as a sensitive layer deposited on a gold electrode. This sensor combines the functional groups of hemicellulose that could form a complex with metal ions and agarose with gelling properties to form a stable membrane. The sensor demonstrated a loading ability of Pb2+, with higher affinity compared to other metal ions such as Hg2+, Ni2+, and Cu2+, thanks to the chemical structure of hemicellulose. The detection was measured by square wave voltammetry based on a well-defined redox peak of the metal ions. The sensor shows high sensitivity towards Pb2+ with a detection limit of 1.3 fM. The application in river and sea water using the standard addition method for lead detection was studied.

7.
Nanomaterials (Basel) ; 13(10)2023 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-37242104

RESUMO

Microemulsions are novel drug delivery systems that have garnered significant attention in the pharmaceutical research field. These systems possess several desirable characteristics, such as transparency and thermodynamic stability, which make them suitable for delivering both hydrophilic and hydrophobic drugs. In this comprehensive review, we aim to explore different aspects related to the formulation, characterization, and applications of microemulsions, with a particular emphasis on their potential for cutaneous drug delivery. Microemulsions have shown great promise in overcoming bioavailability concerns and enabling sustained drug delivery. Thus, it is crucial to have a thorough understanding of their formulation and characterization in order to optimize their effectiveness and safety. This review will delve into the different types of microemulsions, their composition, and the factors that affect their stability. Furthermore, the potential of microemulsions as drug delivery systems for skin applications will be discussed. Overall, this review will provide valuable insights into the advantages of microemulsions as drug delivery systems and their potential for improving cutaneous drug delivery.

8.
Talanta ; 260: 124630, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37178675

RESUMO

Methanol (MeOH) is a solvent and cleaning agent used in industry, but it is poisonous when ingested. The recommended release threshold for MeOH vapor is 200 ppm. We present a novel sensitive micro-conductometric MeOH biosensor created by grafting alcohol oxidase (AOX) onto electrospun polystyrene-poly(amidoamine) dendritic polymer blend nanofibers (PS-PAMAM-ESNFs) on interdigitated electrodes (IDEs). The analytical performance of the MeOH microsensor was evaluated using gaseous MeOH, ethanol, and acetone samples collected from the headspace above aqueous solution with known concentration. The sensor's response time (tRes) fluctuates from 13 s to 35 s from lower to higher concentrations. The conductometric sensor has a sensitivity of 150.53 µS.cm-1 (v/v) for MeOH and a detection limit of 100 ppm in the gas phase. The MeOH sensor is 7.3 times less sensitive to ethanol and 136.8 times less sensitive to acetone. The sensor was verified for detecting MeOH in commercial rubbing alcohol samples.

9.
Sensors (Basel) ; 23(7)2023 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-37050763

RESUMO

Biosensors are devices composed of a biorecognition part and of a transduction part [...].


Assuntos
Técnicas Biossensoriais
10.
Talanta ; 260: 124552, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37087947

RESUMO

Previous researches have suggested the potential correlation between the development of breast cancer and the concentration of miRNA-21 in serum. Theoretically the doping of multivalent metal ions in WS2 could bring higher electron transfer capacity, but this hasn't been proven. To fill this research gap, through one-pot method we prepared seven nanocomposite structures modified with different metal ions (Co2+, Ni2+, Mn2+, Zn2+, Fe3+, Cr3+, La3+). Characterization revealed that ammonia produced by hydrothermal urea exfoliated the multilayer graphene oxide (MGO) and provided a nitrogen source for doping reduction to form a 3D flower-like structure (NrGOF) with high specific surface area. Meanwhile, the modification of WS2 by Fe3+ not only enhanced its electrochemical conductivity but also gave the material an additional peroxidase activity centre. In the composite Fe3+-WS2/NrGOF-AgNPs, NrGOF is used as a conductive loading interface for WS2, while Fe3+ served as the catalytic and electron transfer centre for secondary amplification of the electrochemical signal. The experimental results showed that the sensing platform has a low limit of detection (LOD) of 1.18 aM for miRNA-21 in the concentration range of 10-17-10-12 M and has been successfully applied to the detection of real serum samples.


Assuntos
Técnicas Biossensoriais , MicroRNAs , Nanocompostos , Oligoelementos , Nanocompostos/química , Técnicas Eletroquímicas/métodos , Técnicas Biossensoriais/métodos , Limite de Detecção
12.
Sensors (Basel) ; 23(3)2023 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-36772311

RESUMO

To protect consumers from risks related to overexposure to sulfadiazine, total residues of this antibacterial agent in animal-origin foodstuffs not exceed international regulations. To this end, a new electrochemical sensor based on a molecularly imprinted polymer nanocomposite using overoxidized polypyrrole and copper nanoparticles for the detection of sulfadiazine is elaborated. After optimization of the preparation of the electrochemical sensors, their differential pulse voltammetric signal exhibits an excellent stability and reproducibility at 1.05 V, with a large linear range between 10-9 and 10-5 mol L-1 and a low detection limit of 3.1 × 10-10 mol L-1. The produced sulfadiazine sensor was successfully tested in real milk samples. The combination of the properties of the electrical conduction of copper nanoparticles with the properties of the preconcentration of the molecularly imprinted overoxidized polypyrrole allows for the highly sensitive detection of sulfadiazine, even in real milk samples. This strategy is new and leads to the lowest detection limit yet achieved, compared to those of the previously published sulfadiazine electrochemical sensors.


Assuntos
Impressão Molecular , Nanopartículas , Animais , Cobre/química , Sulfadiazina , Polímeros/química , Pirróis/química , Reprodutibilidade dos Testes , Nanopartículas/química , Técnicas Eletroquímicas , Limite de Detecção , Eletrodos
13.
J Microencapsul ; 40(3): 125-156, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36749629

RESUMO

Encapsulation is the way to wrap or coat one substance as a core inside another tiny substance known as a shell at micro and nano scale for protecting the active ingredients from the exterior environment. A lot of active substances, such as flavours, enzymes, drugs, pesticides, vitamins, in addition to catalysts being effectively encapsulated within capsules consisting of different natural as well as synthetic polymers comprising poly(methacrylate), poly(ethylene glycol), cellulose, poly(lactide), poly(styrene), gelatine, poly(lactide-co-glycolide)s, and acacia. The developed capsules release the enclosed substance conveniently and in time through numerous mechanisms, reliant on the ultimate use of final products. Such technology is important for several fields counting food, pharmaceutical, cosmetics, agriculture, and textile industries. The present review focuses on the most important and high-efficiency methods for manufacturing micro/nanocapsules and their several applications in our life.


Assuntos
Nanocápsulas , Polímeros , Polietilenoglicóis
14.
Expert Opin Drug Deliv ; 20(2): 189-204, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36608938

RESUMO

INTRODUCTION: Cancer has one of the highest mortality rates globally. The traditional therapies used to treat cancer have harmful adverse effects. Considering these facts, researchers have explored new therapeutic possibilities with enhanced benefits. Nanoparticle development for cancer detection, in addition to therapy, has shown substantial progress over the past few years. AREA COVERED: Herein, the latest research regarding cancer treatment employing magnetic nanoparticles (MNPs) in chemo-, immuno-, gene-, and radiotherapy along with hyperthermia is summarized, in addition to their physio-chemical features, advantages, and limitations for clinical translation have also been discussed. EXPERT OPINION: MNPs are being extensively investigated and developed into effective modules for cancer therapy. They are highly functional tools aimed at cancer therapy owing to their excellent superparamagnetic, chemical, biocompatible, physical, and biodegradable properties.


Assuntos
Hipertermia Induzida , Nanopartículas de Magnetita , Nanopartículas , Neoplasias , Humanos , Nanopartículas de Magnetita/uso terapêutico , Nanopartículas de Magnetita/química , Neoplasias/tratamento farmacológico , Magnetismo , Terapia Combinada
15.
Int J Pharm ; 632: 122570, 2023 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-36587775

RESUMO

Nanotechnology has ultimately come into the domain of drug delivery. Nanosystems for delivery of drugs are promptly emerging science utilizing different nanoparticles as carriers. Biocompatible and stable nanocarriers are novel diagnosis tools or therapy agents for explicitly targeting locates with controllable way. Nanocarriers propose numerous advantages to treat diseases via site-specific as well as targeted delivery of particular therapeutics. In recent times, there are number of outstanding nanocarriers use to deliver bio-, chemo-, or immuno- therapeutic agents to obtain effectual therapeutic reactions and to minimalize unwanted adverse-effects. Nanoparticles possess remarkable potential for active drug delivery. Moreover, conjugation of drugs with nanocarriers protects drugs from metabolic or chemical modifications, through their way to targeted cells and hence increased their bioavailability. In this review, various systems integrated with different types of nanocarriers (inorganic. organic, quantum dots, and carbon nanotubes) having different compositions, physical and chemical properties have been discussed for drug delivery applications.


Assuntos
Nanopartículas , Nanotubos de Carbono , Nanotubos de Carbono/química , Sistemas de Liberação de Medicamentos , Nanopartículas/química , Nanotecnologia , Preparações Farmacêuticas , Portadores de Fármacos/química
16.
Micromachines (Basel) ; 13(12)2022 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-36557534

RESUMO

Assessing cortisol levels in human bodies has become essential to diagnose heart failure (HF). In this work, we propose a salivary cortisol detection strategy as part of an easily integrable lab-on-a-chip for detection of HF biomarkers. Our developed capacitive immunosensor based on hafnium oxide (HfO2)/silicon structure showed good linearity between increasing cortisol concentration and the charge-transfer resistance/capacitance. Moreover, the developed biosensor was demonstrated to be highly selective toward cortisol compared to other HF biomarkers such as tumor necrosis factor (TNF-α) and N-terminal pro-brain natriuretic peptide (NT-proBNP). The precision of our developed biosensor was evaluated, and the difference between the determined cortisol concentration in saliva and its expected one is <18%.

17.
Bioelectrochemistry ; 148: 108256, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36081272

RESUMO

MicroRNA-21 (miRNA-21) is a common biomarker with high expression in breast tumors. Therefore, sensitive detection of miRNA-21 is of great significance for clinical breast tumor diagnosis. A TH/rGO/CMK-3/AuNPs nanocomposite is composed of thionine (TH), reduced graphene oxide (rGO), ordered mesoporous carbon (CMK-3), and gold nanoparticles (AuNPs), which help to increase the specific surface area of a glassy carbon electrode (GCE) and to amplify the DPV signal. Meanwhile, methylene blue (MB) was combined with the capture probe guanine and absorbed by the composite material to mediate the differential pulse voltammetry (DPV) of the obtained miRNA biosensor. The current response decreased with increasing miRNA-21 concentration under optimal conditions. The biosensor responds to miRNA-21 in the 0.1fM-1 pM concentration range, and the detection limit (LOD) was 0.046 fM. Moreover, human serum samples were effectively detected utilizing the miRNA-21 biosensor with satisfactory results.


Assuntos
Técnicas Biossensoriais , Grafite , Nanopartículas Metálicas , MicroRNAs , Nanocompostos , Técnicas Biossensoriais/métodos , Carbono , Técnicas Eletroquímicas/métodos , Ouro , Guanina , Humanos , Limite de Detecção , Azul de Metileno
18.
Biosensors (Basel) ; 12(9)2022 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-36140112

RESUMO

Lysozyme (LYS) applications encompass anti-bacterial activity, analgesic, and anti-inflammatory effects. In this work, a porous framework that was based on the polymerization of pyrrole (PPy) in the presence of multi-functional graphene oxide/iron oxide composite (GO@Fe3O4) has been developed. Oxygen-containing and amine groups that were present in the nanocomposite were availed to assembly LYS as the molecularly imprinted polymer (MIP) template. The synthesized material (MIPPy/GO@Fe3O4) was electrodeposited on top of a gold microelectrode array. Transmission electron microscopy (TEM) and X-ray photoelectron spectroscopy (XPS) were used to confirm the adequate preparation of GO@Fe3O4, and the characterization of the resulting molecularly imprinted electrochemical sensor (MIECS) was carried out by electrochemical impedance spectrometry (EIS), FT-IR analysis, and scanning electron microscopy (SEM). The impedimetric responses were analyzed mathematically by fitting to a Q(Q(RW)) equivalent circuit and quantitative determination of LYS was obtained in a linear range from 1 pg/mL to 0.1 µg/mL, presenting good precision (RSD ≈ 10%, n = 5) and low limit of detection (LOD = 0.009 pg/mL). The fabrication of this device is relatively simple, scalable, rapid, and economical, and the sensor can be used up to nine times without disintegration. The MIECS was successfully applied to the determination of LYS in fresh chicken egg white sample and in a commercial drug, resulting in a straightforward platform for the routine monitoring of LYS.


Assuntos
Impressão Molecular , Nanocompostos , Aminas , Anti-Inflamatórios , Técnicas Eletroquímicas/métodos , Eletrodos , Ouro/química , Limite de Detecção , Impressão Molecular/métodos , Polímeros Molecularmente Impressos , Muramidase , Nanocompostos/química , Oxigênio , Polímeros/química , Pirróis/química , Espectroscopia de Infravermelho com Transformada de Fourier
19.
Anal Bioanal Chem ; 414(24): 7325-7334, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35974199

RESUMO

Achieving the early diagnosis of breast cancer, through ultrasensitive detection of tumor marker miRNA-155, is a significant challenge. Therefore, an ultrasensitive hairpin electrochemical biosensor based on graphite-like phase carbon nitride composite was proposed. In this paper, poly(D-glucosamine) (PDG) was used as a stabilizer and reducing agent to prepare gold nanoparticles at room temperature, and then a graphite-like phase with a two-dimensional lamellar structure carbon nitride was further combined with it to obtain the poly(D-glucosamine)/gold nanoparticles/graphite-like phase carbon nitride nanocomposite (PDG/AuNPs/g-C3N4), in order to achieve the goal of signal amplification. The specific hairpin capture probe (HP) that recognized and bound miRNA-155 was then grafted. The hairpin biosensor showed a linear range of 0.1 fM-1 pM with a detection limit of 0.05 fM using differential pulse voltammetry (DPV) electrochemical analysis. Furthermore, the excellent performance hairpin electrochemical biosensor had been applied to the detection of miRNA-155 in human serum samples with good recovery.


Assuntos
Técnicas Biossensoriais , Neoplasias da Mama , Grafite , Nanopartículas Metálicas , MicroRNAs , Nanocompostos , Biomarcadores Tumorais , Técnicas Biossensoriais/métodos , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/genética , Técnicas Eletroquímicas/métodos , Feminino , Glucosamina , Ouro/química , Grafite/química , Humanos , Limite de Detecção , Nanopartículas Metálicas/química , Nanocompostos/química , Nitrilas , Compostos de Nitrogênio , Substâncias Redutoras
20.
Artigo em Inglês | MEDLINE | ID: mdl-35834580

RESUMO

A phospholipid-based liposome layer was used as an effective biomimetic membrane model to study the binding of the pH-dependent fusogenic peptide (E4-GGYC) from the influenza virus hemagglutinin HA2 subunit. To this end, a multiparameter surface plasmon resonance approach (MP-SPR) was used for monitoring peptide-liposome interactions at two pH values (4.5 and 8) by means of recording sensorgrams in real time without the need for labeling. Biotinylated liposomes were first immobilized as a monolayer onto the surface of an SPR gold chip coated with a streptavidin layer. Multiple sets of sensorgrams with different HA2 peptide concentrations were generated at both pHs. Dual-wavelength Fresnel layer modeling was applied to calculate the thickness (d) and the refractive index (n) of the liposome layer to monitor the change in its optical parameters upon interaction with the peptide. At acidic pH, the peptide, in its α helix form, entered the lipid bilayer of liposomes, inducing vesicle swelling and increasing membrane robustness. Conversely, a contraction of liposomes was observed at pH 8, associated with noninsertion of the peptide in the double layer of phospholipids. The equilibrium dissociation constant KD = 4.7 × 10-7 M of the peptide/liposome interaction at pH 4.5 was determined by fitting the "OneToOne" model to the experimental sensorgrams using Trace Drawer software. Our experimental approach showed that the HA2 peptide at a concentration up to 100 µM produced no disruption of liposomes at pH 4.5.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...