Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Opt ; 45(34): 8674-88, 2006 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-17119564

RESUMO

The Extreme-Ultraviolet Imaging Spectrometer (EIS) is the first of a new generation of normal-incidence, two-optical-element spectroscopic instruments developed for space solar extreme-ultraviolet astronomy. The instrument is currently mounted on the Solar-B satellite for a planned launch in late 2006. The instrument observes in two spectral bands, 170-210 A and 250-290 A. The spectrograph geometry and grating prescription were optimized to obtain excellent imaging while still maintaining readily achievable physical and fabrication tolerances. A refined technique using low ruling density surrogate gratings and optical metrology was developed to align the instrument with visible light. Slit rasters of the solar surface are obtained by mechanically tilting the mirror. A slit exchange mechanism allows selection among four slits at the telescope focal plane. Each slit is precisely located at the focal plane. The spectrograph imaging performance was optically characterized in the laboratory. The resolution was measured using the Mg iii and Ne iii lines in the range of 171-200 A. The He ii line at 256 A and Ne iii lines were used in the range of 251-284 A. The measurements demonstrate an equivalent resolution of ~2 arc sec? on the solar surface, in good agreement with the predicted performance. We describe the EIS optics, mechanisms, and measured performance.

2.
Appl Opt ; 45(34): 8689-705, 2006 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-17119565

RESUMO

The laboratory end-to-end testing of the Extreme-Ultraviolet Imaging Spectrometer (EIS) for the Solar-B satellite is reported. A short overview of the EIS, which observes in two bands in the extreme-ultraviolet wavelength range, is given. The calibration apparatus is described, including details of the light sources used. The data reduction and analysis procedure are outlined. The wavelength calibration using a Penning source to illuminate the aperture fully is presented. We discuss the aperture determination using a radiometrically calibrated hollow-cathode-based source. We then give an account of the predicted and measured efficiencies from consideration of the efficiencies of individual optical elements in first order, an account of efficiencies out of band when radiation incident in one band is detected in the other, and efficiencies in multiple orders. The efficiencies measured in first order for in band and out of band are compared with the predictions and the sensitivity, and its uncertainties are derived. Application of the radiometric calibration is discussed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...