Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Medicina (Kaunas) ; 60(2)2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38399609

RESUMO

Background and Objectives: The purpose of this study was to compare clinical outcomes and polyethylene (PE) insert thickness between total knee arthroplasty (TKA) systems providing 1 mm and 2 mm increments. Materials and Methods: In this randomized controlled trial, 50 patients (100 knees) undergoing same-day or staggered bilateral TKA were randomized to receive a TKA system providing 1 mm increments in one knee (1 mm group) and a TKA system providing 2 mm increments in the other knee (2 mm group). At 2 years postoperatively, Knee Society Score (KSS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, Forgotten Joint Score (FJS), range of motion (ROM), and insert thicknesses were compared between the groups. Results: A total of 47 patients (94 knees) participated in follow-up analysis. In each group, patient-reported outcomes improved significantly after TKA (all, p < 0.05). There were no significant differences in patient-reported outcomes. The mean ROM was not significantly different between groups at preoperative and 2-year points. The rate of postoperative flexion contracture ≥ 5° was 2.1% and 4.3%, and the rate of postoperative recurvatum ≥ 5° was 4.3% and 2.1% in the 1 mm group and 2 mm, respectively (all, p = 1.000). Mean insert thickness was significantly thinner in the 1 mm group than the 2 mm group (p = 0.001). The usage rate of a thick insert (≥14 mm) was 12.7% and 38.3% in the 1 mm group and 2 mm group (p = 0.005). Conclusions: The use of a TKA system providing 1 mm PE insert thickness increments offered no clinical benefit in terms of patient reported outcomes over systems with 2 mm increments at 2 years of follow-up. However, the TKA system with 1 mm increments showed significantly thinner PE insert usage. As a theoretical advantage of 1 mm increments has yet to be proven, the mid- to long-term effects of thinner PE insert usage must be determined.


Assuntos
Prótese do Joelho , Osteoartrite do Joelho , Humanos , Polietileno/uso terapêutico , Resultado do Tratamento , Articulação do Joelho/cirurgia , Joelho , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular
2.
Am J Sports Med ; 47(7): 1694-1700, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31084488

RESUMO

BACKGROUND: Injection of intra-articular corticosteroids is effective for improving the recovery of range of motion (ROM) and pain in various conditions of the shoulder but its use is limited after rotator cuff repair owing to concern over the possible harmful effects of steroids on the repaired tendon. PURPOSE: To evaluate the effect of intra-articular corticosteroid injections on the clinical outcomes and cuff integrity of patients after rotator cuff repair. STUDY DESIGN: Randomized controlled trial; Level of evidence, 1. METHODS: Between March 2011 and April 2014, 80 patients with a small- to medium-sized rotator cuff tear were enrolled in this study and underwent arthroscopic rotator cuff repair. Forty patients received an injection of triamcinolone (40 mg) and lidocaine (1.5 mL) into the glenohumeral joint 8 weeks after surgery (group 1), while the remaining 40 patients received normal saline injection (group 2). Outcome measures-including ROM, American Shoulder and Elbow Surgeons (ASES) score, Constant score, pain visual analog scale, and Simple Shoulder Test score-were evaluated at 3, 6, and 12 months after surgery and at the last follow-up. The integrity of the repaired tendon was evaluated by magnetic resonance imaging (MRI) and classified per Sugaya classification at 8 weeks (before injection) and 12 months after surgery. RESULTS: The mean follow-up period was 25.7 months. At 3 months postoperatively, patients in group 1 had a significantly higher ROM with respect to forward flexion ( P = .05), external rotation at the side ( P = .05), and external rotation at abduction ( P = .04) as compared with group 2, whereas no significant difference was noted between the groups for internal rotation behind the back ( P = .65). Patients in group 1 had significantly lower visual analog scale pain scores ( P = .02) and higher ASES scores (group 1, 68.90; group 2, 60.28; P = .02) at 3-month follow-up. However, there was no significant difference after 6 months with respect to ROM and ASES scores (group 1, 77.80; group 2, 75.88; P = .33). Retears (Sugaya classification IV and V) were determined by MRI at 12 months and observed in a total of 7 patients (8.8%): 3 from group 1 (7.5%) and 4 from group 2 (10%). No retears were observed on MRI in the remaining 73 patients (91.2%): 37 patients from group 1 and 36 patients from group 2. There was no statistically significant difference in rate of retears between groups ( P = .69). CONCLUSION: Intra-articular injection of corticosteroids after rotator cuff repair does not increase the risk of retears and is thus an effective and safe treatment method for increasing ROM (forward flexion, external rotation) and improving clinical score (ASES) during the early postoperative period of patients undergoing rotator cuff repair.


Assuntos
Corticosteroides/administração & dosagem , Artroscopia/métodos , Lesões do Manguito Rotador/cirurgia , Manguito Rotador/cirurgia , Idoso , Método Duplo-Cego , Feminino , Humanos , Injeções , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Prospectivos , Amplitude de Movimento Articular , Rotação , Articulação do Ombro/cirurgia , Resultado do Tratamento
3.
Medicine (Baltimore) ; 97(13): e0189, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29595654

RESUMO

RATIONALE: To the best of our knowledge, this is an extremely rare case of traumatic C1-2 rotatory subluxation associated with multiple C2 fractures. PATIENT CONCERNS: We report the case of a 63-year-old man with type 2 traumatic C1-2 rotatory subluxation (Fielding and Hawkins classification) associated with type III dens (Anderson and D'Alonzo classification) and bilateral articular facet fractures of C2. This injury occurred as a result of falling down in a drunken state. The patient complained of neck pain and mild degree of torticollis but did not show any neurologic abnormalities. DIAGNOSES: Plain radiographs of cervical spine showed extensive soft tissue swelling, a fracture fragment, disruption of spinolaminar line at C1-2 level, and bony overlapping of right side lateral joint of C1-2. Two- and three-dimensional reconstructed computed tomography scans clearly demonstrated complicated C1-2 combined injury. The atlantodental interval was normal. INTERVENTION: By skull traction and derotation, closed reduction of C1-2 rotatory subluxation with a type III dens and bilateral articular facet fractures of C2 was successfully achieved. He was managed with halovest fixation for 3 months. OUTCOMES: At the 1-year follow-up visit solid fusion and improvement of clinical symptoms were achieved without C1-2 instability. LESSONS: Despite traumatic C1-2 rotatory subluxation associated with multiple C2 fractures, trial of closed reduction should be considered as the first choice of treatment so as to preserve C1-2 motion.


Assuntos
Vértebras Cervicais , Luxações Articulares/patologia , Fraturas da Coluna Vertebral/patologia , Acidentes por Quedas , Intoxicação Alcoólica , Fraturas Múltiplas , Humanos , Luxações Articulares/diagnóstico , Luxações Articulares/terapia , Masculino , Pessoa de Meia-Idade , Fraturas da Coluna Vertebral/diagnóstico , Fraturas da Coluna Vertebral/terapia
4.
J Pediatr Orthop B ; 26(5): 429-432, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27846037

RESUMO

A 10-year-old patient presented to the emergency room after a motor vehicle accident. The patient was diagnosed with left scapular body fracture and concomitant inferior angle apophyseal separation with intrathoracic displacement causing hemopneumothorax. The displaced scapular body was reduced surgically and separated apophysis of the inferior angle was fixed to the scapular body with absorbable suture. Postoperative 2-year follow-up showed a good result. A literature search found two pediatric cases of intrathoracic displacement of scapular body fracture. There was no previous report of apophyseal separation of the inferior angle of the scapula.


Assuntos
Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Escápula/diagnóstico por imagem , Escápula/cirurgia , Vértebras Torácicas/diagnóstico por imagem , Vértebras Torácicas/cirurgia , Criança , Humanos , Masculino
5.
Korean J Physiol Pharmacol ; 12(3): 111-5, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20157403

RESUMO

The effects of (-)-epigallocatechin gallate (EGCG) on pacemaker activities of cultured interstitial cells of Cajal (ICC) from murine small intestine were investigated using whole-cell patch-clamp technique at 30 and Ca(2+) image analysis. ICC generated spontaneous pacemaker currents at a holding potential of -70 mV. The treatment of ICC with EGCG resulted in a dose-dependent decrease in the frequency and amplitude of pacemaker currents. SQ-22536, an adenylate cyclase inhibitor, and ODQ, a guanylate cyclase inhibitor, did not inhibit the effects of EGCG. EGCG-induced effects on pacemaker currents were not inhibited by glibenclamide, an ATP-sensitive K(+) channel blocker and TEA, a Ca(2+)-activated K(+) channel blocker. Also, we found that EGCG inhibited the spontaneous [Ca(2+)](i) oscillations in cultured ICC. In conclusion, EGCG inhibited the pacemaker activity of ICC and reduced [Ca(2+)](i) oscillations by cAMP-, cGMP-, ATP-sensitive K+ channel-independent manner.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...