Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Lab Med ; 43(1): 73-81, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36045059

RESUMO

Background: BRCA testing is necessary for establishing a management strategy for ovarian cancer. Several BRCA testing strategies, including germline and somatic testing, are implemented in clinical practice in Korea. We aimed to comparatively evaluate their cost-effectiveness from patients' perspective. Methods: We developed a decision model comprising five BRCA testing strategies implemented in Korea: (1) germline testing first, followed by somatic tumor testing for patients without a germline variant; (2) somatic testing first, followed by germline testing for patients with a variant detected by somatic testing; (3) both germline and somatic testing; (4) germline testing alone; and (5) somatic testing alone, with no testing as the comparator. One-way sensitivity analysis was conducted to test the uncertainty of key parameters. Results: Assuming a willingness-to-pay of $20,000 per progression-free life-year gain (PF-LYG), all five strategies were considered cost-effective. Strategy 4 was the most cost-effective option, with an incremental cost-effectiveness ratio (ICER) of $2,547.7 per PF-LYG, followed by strategy 1, with an ICER of $3,978.4 per PF-LYG. Even when the parameter values were varied within the possible range, the ICERs of all strategies did not exceed the willingness-to-pay threshold. Conclusions: Considering the importance of knowing a patient's BRCA gene status, germline testing first, followed by somatic testing, may be a reasonable option.


Assuntos
Neoplasias Ovarianas , Análise Custo-Benefício , Feminino , Células Germinativas/patologia , Humanos , Neoplasias Ovarianas/diagnóstico , Neoplasias Ovarianas/genética , Neoplasias Ovarianas/patologia , República da Coreia
2.
HLA ; 100(3): 260-261, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35557036

RESUMO

The HLA-A*26:01:75 allele differs from HLA-A*26:01:01:01 allele by a single nucleotide in codon -10.3.


Assuntos
Antígenos HLA-A , Sequenciamento de Nucleotídeos em Larga Escala , Alelos , Códon , Éxons/genética , Antígenos HLA-A/genética , Humanos
3.
J Int Med Res ; 49(6): 3000605211014390, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34154430

RESUMO

OBJECTIVE: LIA-ANA-Profile-17S is a multiplex line immunoassay that simultaneously detects 17 antinuclear antibodies (ANAs) against extractable nuclear antigens (ENAs). We evaluated the utility of LIA-ANA-Profile-17S as a supplement to ANA indirect immunofluorescence (IIF) and EliA ENA (a fluorescence enzyme immunoassay) for diagnosis of ANA-associated rheumatic diseases. METHODS: Sera were collected from 245 patients referred for an ANA IIF test. LIA-ANA-Profile-17S results were compared with those of EliA ENA. The kappa coefficients, agreement rates, and diagnostic performance of these tests were assessed for systemic lupus erythematosus (SLE) and Sjögren's syndrome (SjS). RESULTS: We observed almost perfect interassay agreement for antibodies against Ro52/Ro60, CENP-B, and Scl-70 (kappa = 0.91, 0.97, and 1.00, respectively); strong agreement for anti-SS-B/La antibody (kappa = 0.81); and relatively low agreement for other antibodies, including those against dsDNA, Sm, RNP, and Jo-1. For SLE diagnosis, LIA-ANA-Profile-17S showed lower sensitivity and similar specificity compared with EliA ENA. The sensitivity and specificity of these two assays were similar for SjS diagnosis. CONCLUSIONS: The specificity of LIA-ANA-Profile-17S was enhanced when combined with ANA IIF and was comparable with that of EliA ENA. LIA-ANA-Profile-17S showed relatively good agreement with EliA ENA. In combination with ANA IIF, these assays showed enhanced diagnostic performance.


Assuntos
Anticorpos Antinucleares , Antígenos Nucleares , Técnica Indireta de Fluorescência para Anticorpo , Humanos , Imunoensaio , Técnicas Imunoenzimáticas , Sensibilidade e Especificidade
4.
ACS Appl Mater Interfaces ; 7(15): 7920-6, 2015 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-25835190

RESUMO

Highly stretchable conductors are essential components in deformable electronics. Owing to their high stretchability and conductivity, liquid metals have attracted significant attention for use as circuits and interconnections. However, their poor wettability to stretchable metal electrodes prevents the formation of stable electrical connections. This study examined two approaches for creating a stable interface between a liquid metal (EGaIn) and stretchable metal electrodes via: (i) the use of honeycomb-structured stretchable metal electrodes and (ii) the addition of a conducting polymer interlayer. The line width of the honeycomb had a significant influence on the formation of a stable interface. The liquid metal formed a stable film layer on honeycomb metal electrodes, which have line widths of less than 50 µm. Coating PEDOT: PSS with a nonionic surfactant lowered the interfacial energy of EGaIn with flat stretchable metal surfaces; hence EGaIn was coated uniformly on the stretchable metal surfaces. Strain sensors were fabricated as a demonstrative example of an application that utilizes the stable interface.

5.
Dent Mater J ; 27(1): 133-8, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18309622

RESUMO

The present study investigated the effect of fluoride released from dental restoratives on orthodontic NiTi wires. Five different restoratives (four fluoride-containing and one non-fluoride-containing) and four different NiTi wires were examined in this study. The pH of artificial saliva (AS) was adjusted to 2.5 and 6. Content of released fluoride was determined daily for 10 days. The morphology of wires was observed using a scanning electron microscope. After immersion for 10 days, the initial microhardness of the wires decreased by 0.3-5.6% depending on the test solution. Dyract AP (DA) and F2000 (F2) (compomers) released significantly more fluoride than the other resin products (composite resins) regardless of the test solution. In pH 2.5 solution, both DA and F2 released 40-45 ppm/day fluoride for five to six days. As for the wires in contact, they did not show any visible modification in surface morphology. Therefore, despite the released fluoride, wires in contact with the fluoride-containing restoratives were not damaged regardless of the pH value of test solution.


Assuntos
Cariostáticos/química , Ligas Dentárias/química , Materiais Dentários/química , Restauração Dentária Permanente , Fluoretos/química , Níquel/química , Fios Ortodônticos , Titânio/química , Ligas/química , Compômeros/química , Resinas Compostas/química , Cobre/química , Cimentos de Ionômeros de Vidro/química , Dureza , Humanos , Concentração de Íons de Hidrogênio , Teste de Materiais , Microscopia Eletrônica de Varredura , Saliva Artificial/química , Propriedades de Superfície , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...