Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Knee Surg Relat Res ; 23(3): 153-8, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22570827

RESUMO

PURPOSE: We attempted to determine the degree of rotation of the femoral component to achieve an ideal rectangular flexion gap with minimal medial collateral ligament (MCL) release using a modified measured technique. MATERIALS AND METHODS: Group I consisted of 60 osteoarthritis patients (72 cases) who underwent total knee arthroplasty (TKA) with minimal MCL release and Group II consisted of 48 patients without osteoarthritis (61 cases). We performed computed tomography (CT) scanning of the knee with 90 degree flexion in all of the patients and analyzed the angles between the distal femur landmarks and the tibial mechanical axis using a Picture Archiving Communication system. External rotation of the femoral component from the Whiteside line and posterior condylar line was measured in group I who underwent TKA with minimum MCL release. The variance in the mediolateral flexion gap according to the degree of rotation was also measured using an Auto-Computer Aided Design program. RESULTS: The CT scans showed that the Whiteside line, posterior condylar line, and transepicondylar line was more internally rotated on average from the longitudinal axis of tibia by 4.12°, 5.54°, and 4.64°, respectively, in group I compared to group II. In group I, the femoral component was inserted with an average external rotation of 5.6° from the posterior condylar line and with an average external rotation of 2.0° from the Whiteside line with minimal MCL release. From the measurements of the femoral component size and the variance in the degree of rotation using an Auto-CAD program, it was found that the change in the mediolateral flexion gap was greater when the rotation angle was greater and it was greater when the size of femoral component was larger at the same rotation angle. CONCLUSIONS: The average rotation angle of the femoral component to achieve an ideal rectangular flexion gap with minimal MCL release in TKA was an external rotation of 5.6° from the posterior condylar line and an external rotation of 2.0° from the Whiteside line. We concluded that when a femoral component is small in size, greater than average external rotation needs to be applied and when a femoral component is large in size, less than average external rotation needs to be applied.

3.
J Cardiovasc Ultrasound ; 19(4): 199-202, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22259664

RESUMO

Cardiac conduction system impairment is a rare clinical manifestation of Behçet's disease. We report a patient who showed 1st degree atrioventricular block at first presentation, and showed aggravated finding of 3rd degree atrioventricular block on five months later. His cardiac manifestation finally developed to acute severe aortic regurgitation on six months later from his first cardiac manifestation. We observed this rapid progression during 6 months and successfully improved symptom and disease severity of the patient with treatment targeting Behçet's disease.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...