Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
JACC Adv ; 3(3)2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38433786

RESUMO

BACKGROUND: Severe COVID-19 infection is known to alter myocardial perfusion through its effects on the endothelium and microvasculature. However, the majority of patients with COVID-19 infection experience only mild symptoms, and it is unknown if their myocardial perfusion is altered after infection. OBJECTIVES: The authors aimed to determine if there are abnormalities in myocardial blood flow (MBF), as measured by stress cardiac magnetic resonance (CMR), in individuals after a mild COVID-19 infection. METHODS: We conducted a prospective, comparative study of individuals who had a prior mild COVID-19 infection (n = 30) and matched controls (n = 26) using stress CMR. Stress and rest myocardial blood flow (sMBF, rMBF) were quantified using the dual sequence technique. Myocardial perfusion reserve was calculated as sMBF/rMBF. Unpaired t-tests were used to test differences between the groups. RESULTS: The median time interval between COVID-19 infection and CMR was 5.6 (IQR: 4-8) months. No patients with the COVID-19 infection required hospitalization. Symptoms including chest pain, shortness of breath, syncope, and palpitations were more commonly present in the group with prior COVID-19 infection than in the control group (57% vs 7%, P < 0.001). No significant differences in rMBF (1.08 ± 0.27 mL/g/min vs 0.97 ± 0.29 mL/g/min, P = 0.16), sMBF (3.08 ± 0.79 mL/g/min vs 3.06 ± 0.89 mL/g/min, P = 0.91), or myocardial perfusion reserve (2.95 ± 0.90 vs 3.39 ± 1.25, P = 0.13) were observed between the groups. CONCLUSIONS: This study suggests that there are no significant abnormalities in rest or stress myocardial perfusion, and thus microvascular function, in individuals after mild COVID-19 infection.

2.
Med Phys ; 50(8): 4734-4743, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37415411

RESUMO

BACKGROUND: The production of individualized anthropomorphic phantoms via three-dimensional (3D) printing methods offers promising possibilities to assess and optimize radiation exposures for specifically relevant patient groups (i.e., overweighed or pregnant persons) that are not adequately represented by standardized anthropomorphic phantoms. However, the equivalence of printed phantoms must be demonstrated exemplarily with respect to the resulting image contrasts and dose distributions. PURPOSE: To reproduce a conventionally produced anthropomorphic phantom of a female chest and breasts and to evaluate their equivalence with respect to image contrasts and absorbed doses at the example of a computed tomography (CT) examination of the chest. METHODS: In a first step, the effect of different print settings on the CT values of printed samples was systematically investigated. Subsequently, a transversal slice and breast add-ons of a conventionally produced female body phantom were reproduced using a multi-material extrusion-based printer, considering six different types of tissues (muscle, lung, adipose, and glandular breast tissue, as well as bone and cartilage). CT images of the printed and conventionally produced phantom parts were evaluated with respect to their geometric correspondence, image contrasts, and absorbed doses measured using thermoluminescent dosimeters. RESULTS: CT values of printed objects are highly sensitive to the selected print settings. The soft tissues of the conventionally produced phantom could be reproduced with a good agreement. Minor differences in CT values were observed for bone and lung tissue, whereas absorbed doses to the relevant tissues were identical within the measurement uncertainties. CONCLUSION: 3D-printed phantoms are with exception of minor contrast differences equivalent to their conventionally manufactured counterparts. When comparing the two production techniques, it is important to note that conventionally manufactured phantoms should not be considered as absolute benchmarks, as they also only approximate the human body in terms of its absorption, and attenuation of x-rays as well as its geometry.


Assuntos
Mama , Imagens de Fantasmas , Impressão Tridimensional , Tomografia Computadorizada por Raios X , Feminino , Humanos , Tomografia Computadorizada por Raios X/métodos , Mama/diagnóstico por imagem
3.
Radiat Oncol ; 18(1): 88, 2023 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-37217934

RESUMO

BACKGROUND: In stereotactic radiotherapy, dose is prescribed to an isodose surrounding the planning target volume (PTV). However, the desired dose inhomogeneity inside the PTV leaves the specific dose distribution to the gross tumor volume (GTV) unspecified. A simultaneously integrated boost (SIB) to the GTV could solve this shortcoming. In a retrospective planning study with 20 unresected brain metastases, a SIB approach was tested against the classical prescription. METHODS: For all metastases, the GTV was isotropically enlarged by 3 mm to a PTV. Two plans were generated, one according to the classical 80% concept with 5 times 7 Gy prescribed (on D2%) to the 80% PTV surrounding isodose (with D98%(PTV) ≥ 35 Gy), and the other one following a SIB concept with 5 times 8.5 Gy average GTV dose and with D98%(PTV) ≥ 35 Gy as additional requirement. Plan pairs were compared in terms of homogeneity inside GTV, high dose in PTV rim around GTV, and dose conformity and gradients around PTV using Wilcoxon matched pairs signed rank test. RESULTS: The SIB concept was superior to the classical 80% concept concerning dose homogeneity inside GTV: Heterogeneity index of GTV was in the SIB concept (median 0.0513, range 0.0397-0.0757) significantly (p = 0.001) lower than in the 80% concept (median 0.0894, range 0.0447-0.1872). Dose gradients around PTV were not inferior. The other examined measures were comparable. CONCLUSION: Our stereotactic SIB concept better defines the dose distribution inside PTV and can be considered for clinical use.


Assuntos
Neoplasias Encefálicas , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos , Estudos de Viabilidade , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundário
4.
Int J Cardiovasc Imaging ; 39(5): 1001-1011, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36648573

RESUMO

This study aimed to assess the image quality and accuracy of respiratory-gated real-time two-dimensional (2D) cine incorporating deep learning reconstruction (DLR) for the quantification of biventricular volumes and function compared with those of the standard reference, that is, breath-hold 2D balanced steady-state free precession (bSSFP) cine, in an adult population. Twenty-four patients (15 men, mean age 50.7 ± 16.5 years) underwent cardiac magnetic resonance for clinical indications, and 2D DLR and bSSFP cine were acquired on the short-axis view. The image quality scores were based on three main criteria: blood-to-myocardial contrast, endocardial edge delineation, and presence of motion artifacts throughout the cardiac cycle. Biventricular end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and left ventricular mass (LVM) were analyzed. The 2D DLR cine had significantly shorter scan time than bSSFP (41.0 ± 11.3 s vs. 327.6 ± 65.8 s; p < 0.0001). Despite an analysis of endocardial edge definition and motion artifacts showed significant impairment using DLR cine compared with bSSFP (p < 0.01), the two sequences demonstrated no significant difference in terms of biventricular EDV, ESV, SV, and EF (p > 0.05). Moreover, the linear regression yielded good agreement between the two techniques (r ≥ 0.76). However, the LVM was underestimated for DLR cine (109.8 ± 34.6 g) compared with that for bSSFP (116.2 ± 40.2 g; p = 0.0291). Respiratory-gated 2D DLR cine is a reliable technique that could be used in the evaluation of biventricular volumes and function in an adult population.


Assuntos
Aprendizado Profundo , Masculino , Adulto , Humanos , Pessoa de Meia-Idade , Idoso , Reprodutibilidade dos Testes , Valor Preditivo dos Testes , Imagem Cinética por Ressonância Magnética/métodos , Volume Sistólico , Função Ventricular
5.
Sci Rep ; 11(1): 18546, 2021 09 17.
Artigo em Inglês | MEDLINE | ID: mdl-34535689

RESUMO

Myocardial tissue T1 constitutes a reliable indicator of several heart diseases related to extracellular changes (e.g. edema, fibrosis) as well as fat, iron and amyloid content. Magnetic resonance (MR) T1-mapping is typically achieved by pixel-wise exponential fitting of a series of inversion or saturation recovery measurements. Good anatomical alignment between these measurements is essential for accurate T1 estimation. Motion correction is recommended to improve alignment. However, in the case of inversion recovery sequences, this correction is compromised by the intrinsic contrast variation between frames. A model-based, non-rigid motion correction method for MOLLI series was implemented and validated on a large database of cardiac clinical cases (n = 186). The method relies on a dedicated similarity metric that accounts for the intensity changes caused by T1 magnetization relaxation. The results were compared to uncorrected series and to the standard motion correction included in the scanner. To automate the quantitative analysis of results, a custom data alignment metric was defined. Qualitative evaluation was performed on a subset of cases to confirm the validity of the new metric. Motion correction caused noticeable (i.e. > 5%) performance degradation in 12% of cases with the standard method, compared to 0.3% with the new dedicated method. The average alignment quality was 85% ± 9% with the default correction and 90% ± 7% with the new method. The results of the qualitative evaluation were found to correlate with the quantitative metric. In conclusion, a dedicated motion correction method for T1 mapping MOLLI series has been evaluated on a large database of clinical cardiac MR cases, confirming its increased robustness with respect to the standard method implemented in the scanner.


Assuntos
Cardiopatias/diagnóstico por imagem , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Algoritmos , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade
6.
Int J Cardiol ; 343: 164-170, 2021 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-34517017

RESUMO

BACKGROUND: Despite the low spatial resolution of 2D-multisegment late gadolinium enhancement (2D-MSLGE) sequences, it may be useful in uncooperative patients instead of standard 2D single segmented inversion recovery gradient echo late gadolinium enhancement sequences (2D-SSLGE). The aim of the study is to assess the feasibility and comparison of 2D-MSLGE reconstructed with artificial intelligence reconstruction deep learning noise reduction (NR) algorithm compared to standard 2D-SSLGE in consecutive patients with ischemic cardiomyopathy (ICM). METHODS: Fifty-seven patients with known ICM referred for a clinically indicated CMR were enrolled in this study. 2D-MSLGE were reconstructed using a growing level of NR (0%,25%,50%,75%and 100%). Subjective image quality, signal to noise ratio (SNR) and contrast to noise ratio (CNR) were evaluated in each dataset and compared to standard 2D-SSLGE. Moreover, diagnostic accuracy, LGE mass and scan time were compared between 2D-MSLGE with NR and 2D-SSLGE. RESULTS: The application of NR reconstruction ≥50% to 2D-MSLGE provided better subjective image quality, CNR and SNR compared to 2D-SSLGE (p < 0.01). The best compromise in terms of subjective and objective image quality was observed for values of 2D-MSLGE 75%, while no differences were found in terms of LGE quantification between 2D-MSLGE versus 2D-SSLGE, regardless the NR applied. The sensitivity, specificity, negative predictive value, positive predictive value and accuracy of 2D-MSLGE NR 75% were 87.77%,96.27%,96.13%,88.16% and 94.22%, respectively. Time of acquisition of 2D-MSLGE was significantly shorter compared to 2D-SSLGE (p < 0.01). CONCLUSION: When compared to standard 2D-SSLGE, the application of NR reconstruction to 2D-MSLGE provides superior image quality with similar diagnostic accuracy.


Assuntos
Cardiomiopatias , Aprendizado Profundo , Algoritmos , Inteligência Artificial , Meios de Contraste , Estudos de Viabilidade , Gadolínio , Humanos , Imageamento por Ressonância Magnética
7.
MAGMA ; 34(5): 757-766, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33839986

RESUMO

OBJECTIVE: Image post-processing corrects for cardiac and respiratory motion (MoCo) during cardiovascular magnetic resonance (CMR) stress perfusion. The study analyzed its influence on visual image evaluation. MATERIALS AND METHODS: Sixty-two patients with (suspected) coronary artery disease underwent a standard CMR stress perfusion exam during free-breathing. Image post-processing was performed without (non-MoCo) and with MoCo (image intensity normalization; motion extraction with iterative non-rigid registration; motion warping with the combined displacement field). Images were evaluated regarding the perfusion pattern (perfusion deficit, dark rim artifact, uncertain signal loss, and normal perfusion), the general image quality (non-diagnostic, imperfect, good, and excellent), and the reader's subjective confidence to assess the images (not confident, confident, very confident). RESULTS: Fifty-three (non-MoCo) and 52 (MoCo) myocardial segments were rated as 'perfusion deficit', 113 vs. 109 as 'dark rim artifacts', 9 vs. 7 as 'uncertain signal loss', and 817 vs. 824 as 'normal'. Agreement between non-MoCo and MoCo was high with no diagnostic difference per-patient. The image quality of MoCo was rated more often as 'good' or 'excellent' (92 vs. 63%), and the diagnostic confidence more often as "very confident" (71 vs. 45%) compared to non-MoCo. CONCLUSIONS: The comparison of perfusion images acquired during free-breathing and post-processed with and without motion correction demonstrated that both methods led to a consistent evaluation of the perfusion pattern, while the image quality and the reader's subjective confidence to assess the images were rated more favorably for MoCo.


Assuntos
Coração , Angiografia por Ressonância Magnética , Artefatos , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Movimento (Física) , Imagem de Perfusão
8.
Br J Radiol ; 94(1120): 20201249, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33733811

RESUMO

OBJECTIVE: To compare left ventricular (LV) and right ventricular (RV) volume, function, and image quality of a respiratory-triggered two-dimensional (2D)-cine k-adaptive-t-autocalibrating reconstruction for Cartesian sampling (2D kat-ARC) with those of the standard reference, namely, breath-hold 2D balanced steady-state free precession (2D SSFP), in patients with repaired tetralogy of Fallot (TOF). METHODS: 30 patients (14 males, mean age 32.2 ± 13.9 years) underwent cardiac magnetic resonance, and 2D kat-ARC and 2D SSFP images were acquired on short-axis view. Biventricular end-diastolic volume (EDV) and end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and LV mass (LVM) were analysed. RESULTS: The 2D kat-ARC had significantly shorter scan time (35.2 ± 9.1 s vs 80.4 ± 16.7 s; p < 0.0001). Despite an analysis of image quality showed significant impairment using 2D kat-ARC compared to 2D SSFP cine (p < 0.0001), the two sequences demonstrated no significant difference in terms of biventricular EDV, LVESV, LVSV, LVEF, and LVM. However, the RVESV was overestimated for 2D kat-ARC compared with that for 2D SSFP (73.8 ± 43.2 ml vs 70.3 ± 44.5 ml, p = 0.0002) and the RVSV and RVEF were underestimated (RVSV = 46.2±20.5 ml vs 49.4 ± 20.4 ml, p = 0.0024; RVEF = 40.2±12.7% vs. 43.5±14.0%, p = 0.0002). CONCLUSION: Respiratory-triggered 2D kat-ARC cine is a reliable technique that could be used in the evaluation of LV volumes and function. ADVANCES IN KNOWLEDGE: 2D cine kat-ARC is a reliable technique for the assessment LV volume and function in patients with repaired TOF.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico por imagem , Adulto , Suspensão da Respiração , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Complicações Pós-Operatórias/fisiopatologia , Reprodutibilidade dos Testes , Volume Sistólico , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Direita/fisiopatologia
9.
Eur Radiol ; 31(6): 3846-3855, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33219845

RESUMO

OBJECTIVES: The aim of this study was to assess the effect of a deep learning (DL)-based reconstruction algorithm on late gadolinium enhancement (LGE) image quality and to evaluate its influence on scar quantification. METHODS: Sixty patients (46 ± 17 years, 50% male) with suspected or known cardiomyopathy underwent CMR. Short-axis LGE images were reconstructed using the conventional reconstruction and a DL network (DLRecon) with tunable noise reduction (NR) levels from 0 to 100%. Image quality of standard LGE images and DLRecon images with 75% NR was scored using a 5-point scale (poor to excellent). In 30 patients with LGE, scar size was quantified using thresholding techniques with different standard deviations (SD) above remote myocardium, and using full width at half maximum (FWHM) technique in images with varying NR levels. RESULTS: DLRecon images were of higher quality than standard LGE images (subjective quality score 3.3 ± 0.5 vs. 3.6 ± 0.7, p < 0.001). Scar size increased with increasing NR levels using the SD methods. With 100% NR level, scar size increased 36%, 87%, and 138% using 2SD, 4SD, and 6SD quantification method, respectively, compared to standard LGE images (all p values < 0.001). However, with the FWHM method, no differences in scar size were found (p = 0.06). CONCLUSIONS: LGE image quality improved significantly using a DL-based reconstruction algorithm. However, this algorithm has an important impact on scar quantification depending on which quantification technique is used. The FWHM method is preferred because of its independency of NR. Clinicians should be aware of this impact on scar quantification, as DL-based reconstruction algorithms are being used. KEY POINTS: • The image quality based on (subjective) visual assessment and image sharpness of late gadolinium enhancement images improved significantly using a deep learning-based reconstruction algorithm that aims to reconstruct high signal-to-noise images using a denoising technique. • Special care should be taken when scar size is quantified using thresholding techniques with different standard deviations above remote myocardium because of the large impact of these advanced image enhancement algorithms. • The full width at half maximum method is recommended to quantify scar size when deep learning algorithms based on noise reduction are used, as this method is the least sensitive to the level of noise and showed the best agreement with visual late gadolinium enhancement assessment.


Assuntos
Aprendizado Profundo , Gadolínio , Algoritmos , Cicatriz/diagnóstico por imagem , Cicatriz/patologia , Meios de Contraste , Feminino , Humanos , Aumento da Imagem , Imageamento por Ressonância Magnética , Masculino , Miocárdio/patologia
10.
Magn Reson Imaging ; 74: 223-231, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33035638

RESUMO

BACKGROUND: Cardiac magnetic resonance (CMR) flow quantification is typically performed using 2D phase-contrast (PC) imaging of a plane perpendicular to flow. 3D-PC imaging (4D-flow) allows offline quantification anywhere in a thick slab, but is often limited by suboptimal signal, potentially alleviated by contrast enhancement. We developed a non-contrast 4D-flow sequence, which acquires multiple overlapping thin slabs (MOTS) to minimize signal loss, and hypothesized that it could improve image quality, diagnostic accuracy, and aortic flow measurements compared to non-contrast single-slab approach. METHODS: We prospectively studied 20 patients referred for transesophageal echocardiography (TEE), who underwent CMR (GE, 3 T). 2D-PC images of the aortic valve and three 4D-flow datasets covering the heart were acquired, including single-slab, pre- and post-contrast, and non-contrast MOTS. Each 4D-flow dataset was interpreted blindly for ≥moderate valve disease and compared to TEE. Flow visualization through each valve was scored (0 to 4), and aortic-valve flow measured on each 4D-flow dataset and compared to 2D-PC reference. RESULTS: Diagnostic quality visualization was achieved with the pre- and post-contrast 4D-flow acquisitions in 25% and 100% valves, respectively (scores 0.9 ± 1.1 and 3.8 ± 0.5), and in 58% with the non-contrast MOTS (1.6 ± 1.1). Accuracy of detection of valve disease was 75%, 92% and 82%, respectively. Aortic flow measurements were possible in 53%, 95% and in 89% patients, respectively. The correlation between pre-contrast single-slab measurements and 2D-PC reference was weak (r = 0.21), but improved with both contrast enhancement (r = 0.71) and with MOTS (r = 0.67). CONCLUSIONS: Although non-contrast MOTS 4D-flow improves valve function visualization and diagnostic accuracy, a significant proportion of valves cannot be accurately assessed. However, aortic flow measurements using non-contrast MOTS is feasible and reaches similar accuracy to that of contrast-enhanced 4D-flow.


Assuntos
Coração/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética , Aorta/diagnóstico por imagem , Aorta/fisiologia , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
11.
J Thorac Imaging ; 35(5): 326-333, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32845112

RESUMO

PURPOSE: The aim of this study was to assess the reliability of a 2D dark-blood phase-sensitive late gadolinium enhancement sequence (2D-DBPSLGE) compared with 2D phase-sensitive inversion recovery late gadolinium enhancement sequence (2D-BBPSLGE) in patients with ischemic cardiomyopathy (ICM). MATERIALS AND METHODS: A total of 73 patients with a clinical history of ICM were prospectively enrolled. The following endpoints were evaluated: (a) comparison of image quality between 2D-BBPSLGE and 2D-DBPSLGE for differentiation between blood pool-late gadolinium enhancement (LGE), remote myocardium-LGE, and blood pool-remote myocardium; (b) diagnostic accuracy of 2D-DBPSLGE compared with gold standard 2D-BBPSLGE for the evaluation of infarcted segments; (c) diagnostic accuracy of 2D-DBPSLGE for the evaluation of microvascular obstruction (MVO); (d) comparison of transmurality index between 2D-BBPSLGE and 2D-DBPSLGE; (e) comparison of papillary muscle hyperenhancement between 2D-BBPSLGE and 2D-DBPSLGE; inter-reader agreement for depiction of hyperenhanced segments in both LGE sequences. Data were analyzed using paired t test, Wilcoxon test, and McNemar test, and η coefficient and intercorrelation coefficient (ICC). RESULTS: Image quality was superior for 2D-DBPSLGE for differentiation of blood pool-LGE (P<0.001). 2D-DBPSLGE, compared with 2D-BBPSLGE, showed a sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of 96.93%, 99.89%, 99.71%, 98.78, and 99.04%, respectively. Concerning MVO detection, 2D-DBPSLGE showed a sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of 66.67%, 100.00%, 100.00%, 80.95%, and 86.21%, respectively. 2D-DBPSLGE underestimated the transmurality (P=0.007) and identified papillary muscle hyperenhancement (P<0.001). Both LGE sequences showed comparable interobserver agreement for the evaluation of infarcted areas (2D-BBPSLGE: ICC 0.99;2D-DBPSLGE: ICC 0.99). CONCLUSIONS: Compared with 2D-BBPSLGE, 2D-DBPSLGE sequences provide better differentiation between LGE and blood-pool, while underestimating LGE trasmurality and the presence of MVO.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Meios de Contraste , Gadolínio , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Isquemia Miocárdica/diagnóstico por imagem , Cardiomiopatias/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/complicações , Estudos Prospectivos , Reprodutibilidade dos Testes
12.
Radiat Oncol J ; 34(4): 313-321, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27951625

RESUMO

PURPOSE: Total scalp irradiation (TSI) is a rare but challenging indication. We previously reported that non-coplanar intensity-modulated radiotherapy (IMRT) was superior to coplanar IMRT in organ-at-risk (OAR) protection and target dose distribution. This consecutive treatment planning study compared IMRT with volumetric-modulated arc therapy (VMAT). MATERIALS AND METHODS: A retrospective treatment plan databank search was performed and 5 patient cases were randomly selected. Cranial imaging was restored from the initial planning computed tomography (CT) and target volumes and OAR were redelineated. For each patients, three treatment plans were calculated (coplanar/non-coplanar IMRT, VMAT; prescribed dose 50 Gy, single dose 2 Gy). Conformity, homogeneity and dose volume histograms were used for plan. RESULTS: VMAT featured the lowest monitor units and the sharpest dose gradient (1.6 Gy/mm). Planning target volume (PTV) coverage and homogeneity was better in VMAT (coverage, 0.95; homogeneity index [HI], 0.118) compared to IMRT (coverage, 0.94; HI, 0.119) but coplanar IMRT produced the most conformal plans (conformity index [CI], 0.43). Minimum PTV dose range was 66.8% -88.4% in coplanar, 77.5%-88.2% in non-coplanar IMRT and 82.8%-90.3% in VMAT. Mean dose to the brain, brain stem, optic system (maximum dose) and lenses were 18.6, 13.2, 9.1, and 5.2 Gy for VMAT, 21.9, 13.4, 14.5, and 6.3 Gy for non-coplanar and 22.8, 16.5, 11.5, and 5.9 Gy for coplanar IMRT. Maximum optic chiasm dose was 7.7, 8.4, and 11.1 Gy (non-coplanar IMRT, VMAT, and coplanar IMRT). CONCLUSION: Target coverage, homogeneity and OAR protection, was slightly superior in VMAT plans which also produced the sharpest dose gradient towards healthy tissue.

13.
NMR Biomed ; 29(7): 952-60, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27195474

RESUMO

Individual tumor characterization and treatment response monitoring based on current medical imaging methods remain challenging. This work investigates hyperpolarized (13) C compounds in an orthotopic rat hepatocellular carcinoma (HCC) model system before and after transcatheter arterial embolization (TAE). HCC ranks amongst the top six most common cancer types in humans and accounts for one-third of cancer-related deaths worldwide. Early therapy response monitoring could aid in the development of personalized therapy approaches and novel therapeutic concepts. Measurements with selectively (13) C-labeled and hyperpolarized urea, pyruvate and fumarate were performed in tumor-bearing rats before and after TAE. Two-dimensional, slice-selective MRSI was used to obtain spatially resolved maps of tumor perfusion, cell energy metabolic conversion rates and necrosis, which were additionally correlated with immunohistochemistry. All three injected compounds, taken together with their respective metabolites, exhibited similar signal distributions. TAE induced a decrease in blood flow into the tumor and thus a decrease in tumor to muscle and tumor to liver ratios of urea, pyruvate and its metabolites, alanine and lactate, whereas conversion rates remained stable or increased on TAE in tumor, muscle and liver tissue. Conversion from fumarate to malate successfully indicated individual levels of necrosis, and global malate signals after TAE suggested the washout of fumarase or malate itself on necrosis. This study presents a combination of three (13) C compounds as novel candidate biomarkers for a comprehensive characterization of genetically and molecularly diverse HCC using hyperpolarized MRSI, enabling the simultaneous detection of differences in tumor perfusion, metabolism and necrosis. If, as in this study, bolus dynamics are not required and qualitative perfusion information is sufficient, the desired information could be extracted from hyperpolarized fumarate and pyruvate alone, acquired at higher fields with better spectral separation. Copyright © 2016 John Wiley & Sons, Ltd.


Assuntos
Espectroscopia de Ressonância Magnética Nuclear de Carbono-13/métodos , Carcinoma Hepatocelular/metabolismo , Carcinoma Hepatocelular/terapia , Embolização Terapêutica/métodos , Imagem Molecular/métodos , Compostos Orgânicos/metabolismo , Animais , Carcinoma Hepatocelular/diagnóstico , Linhagem Celular Tumoral , Feminino , Imageamento por Ressonância Magnética/métodos , Ratos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
14.
MAGMA ; 28(6): 591-8, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26449715

RESUMO

OBJECTIVE: (13)C metabolic MRI using hyperpolarized (13)C-bicarbonate enables preclinical detection of pH. To improve signal-to-noise ratio, experimental procedures were refined, and the influence of pH, buffer capacity, temperature, and field strength were investigated. MATERIALS AND METHODS: Bicarbonate preparation was investigated. Bicarbonate was prepared and applied in spectroscopy at 1, 3, 14 T using pure dissolution, culture medium, and MCF-7 cell spheroids. Healthy rats were imaged by spectral-spatial spiral acquisition for spatial and temporal bicarbonate distribution, pH mapping, and signal decay analysis. RESULTS: An optimized preparation technique for maximum solubility of 6 mol/L and polarization levels of 19-21% is presented; T1 and SNR dependency on field strength, buffer capacity, and pH was investigated. pH mapping in vivo is demonstrated. CONCLUSION: An optimized bicarbonate preparation and experimental procedure provided improved T1 and SNR values, allowing in vitro and in vivo applications.


Assuntos
Bicarbonatos/metabolismo , Espectroscopia de Prótons por Ressonância Magnética/métodos , Algoritmos , Animais , Isótopos de Carbono , Meios de Contraste , Gadolínio , Concentração de Íons de Hidrogênio , Mucosa Intestinal/metabolismo , Rim/metabolismo , Fígado/metabolismo , Miocárdio/metabolismo , Ratos , Ratos Endogâmicos Lew , Sensibilidade e Especificidade , Razão Sinal-Ruído , Células Tumorais Cultivadas
15.
Magn Reson Med ; 73(6): 2274-82, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25046867

RESUMO

PURPOSE: Because pH plays a crucial role in several diseases, it is desirable to measure pH in vivo noninvasively and in a spatially localized manner. Spatial maps of pH were quantified in vitro, with a focus on method-based errors, and applied in vivo. METHODS: In vitro and in vivo (13) C mapping were performed for various flip angles for bicarbonate (BiC) and CO2 with spectral-spatial excitation and spiral readout in healthy Lewis rats in five slices. Acute subcutaneous sterile inflammation was induced with Concanavalin A in the right leg of Buffalo rats. pH and proton images were measured 2 h after induction. RESULTS: After optimizing the signal to noise ratio of the hyperpolarized (13) C-bicarbonate, error estimation of the spectral-spatial excited spectrum reveals that the method covers the biologically relevant pH range of 6 to 8 with low pH error (< 0.2). Quantification of pH maps shows negligible impact of the residual bicarbonate signal. pH maps reflect the induction of acute metabolic alkalosis. Inflamed, infected regions exhibit lower pH. CONCLUSION: Hyperpolarized (13) C-bicarbonate pH mapping was shown to be sensitive in the biologically relevant pH range. The mapping of pH was applied to healthy in vivo organs and interpreted within inflammation and acute metabolic alkalosis models.


Assuntos
Bicarbonatos/metabolismo , Membro Anterior , Rim/metabolismo , Espectroscopia de Prótons por Ressonância Magnética/métodos , Animais , Isótopos de Carbono , Concentração de Íons de Hidrogênio , Imagens de Fantasmas , Ratos , Ratos Endogâmicos BUF , Ratos Endogâmicos Lew , Sensibilidade e Especificidade , Razão Sinal-Ruído
16.
J Magn Reson Imaging ; 42(1): 175-9, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25256847

RESUMO

BACKGROUND: Inner volume (IV) excitation was explored with respect to scan time reduction of cardiac gated double inversion recovery multi-echo fast spin echo (MEFSE) to measure the transverse relaxation time (T2 ) in the myocardium. METHODS: The IV imaging was achieved by applying orthogonal slice selection for the excitation and refocusing pulses. The T2 map accuracy was investigated using different excitation and refocusing pulses. The performance of IV-MEFSE was compared with MEFSE on phantoms and eight healthy volunteers, acquiring eight echo times in a single breath-hold. RESULTS: Compared with MEFSE, IV-MEFSE allowed a scan time reduction from 26 s to 16 s, but caused a T2 overestimation of approximately 10% due to stimulated echoes. CONCLUSION: IV successfully reduced the scan time to a single breath-hold feasible for many patients and remarkably facilitated the scan prescription, because there was no image aliasing concern. Care should be taken in using IV for T2 mapping because of T2 relaxation time overestimation.


Assuntos
Algoritmos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Coração/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Radiol Res Pract ; 2014: 871619, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25548671

RESUMO

Hyperpolarized (13)C imaging allows real-time in vivo measurements of metabolite levels. Quantification of metabolite conversion between [1-(13)C]pyruvate and downstream metabolites [1-(13)C]alanine, [1-(13)C]lactate, and [(13)C]bicarbonate can be achieved through kinetic modeling. Since pyruvate interacts dynamically and simultaneously with its downstream metabolites, the purpose of this work is the determination of parameter values through a multisite, dynamic model involving possible biochemical pathways present in MR spectroscopy. Kinetic modeling parameters were determined by fitting the multisite model to time-domain dynamic metabolite data. The results for different pyruvate doses were compared with those of different two-site models to evaluate the hypothesis that for identical data the uncertainty of a model and the signal-to-noise ratio determine the sensitivity in detecting small physiological differences in the target metabolism. In comparison to the two-site exchange models, the multisite model yielded metabolic conversion rates with smaller bias and smaller standard deviation, as demonstrated in simulations with different signal-to-noise ratio. Pyruvate dose effects observed previously were confirmed and quantified through metabolic conversion rate values. Parameter interdependency allowed an accurate quantification and can therefore be useful for monitoring metabolic activity in different tissues.

18.
J Magn Reson ; 243: 40-6, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24717443

RESUMO

Dynamic nuclear polarisation has enabled real-time metabolic imaging of pyruvate and its metabolites. Conventional imaging sequences rely on predefined settings and do not account for intersubject variations in biological parameters such as perfusion. We present a fully automatic real-time bolus tracking sequence for hyperpolarised substrates which starts the imaging acquisition at a defined point on the bolus curve. This reduces artefacts due to signal change and allows for a more efficient use of hyperpolarised magnetisation. For single time point imaging methods, bolus tracking enables a more reliable and consistent quantification of metabolic activity. An RF excitation with a small flip angle is used to obtain slice-selective pyruvate tracking information in rats. Moreover, in combination with a copolarised urea and pyruvate injection, spectrally selective tracking on urea allows obtaining localised bolus tracking information without depleting the pyruvate signal. Particularly with regard to clinical application, the bolus tracking technique could provide an important step towards a routine assessment protocol which removes operator dependencies and ensures comparable results.


Assuntos
Rim/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Modelos Biológicos , Ácido Pirúvico/farmacocinética , Animais , Isótopos de Carbono/química , Isótopos de Carbono/farmacocinética , Simulação por Computador , Marcação por Isótopo , Taxa de Depuração Metabólica , Ácido Pirúvico/química , Ratos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Radiat Oncol ; 9: 82, 2014 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-24656070

RESUMO

BACKGROUND: This clinical study compared four different cases of extensive scalp malignancies treated by intensity-modulated radiation therapy. The merits of coplanar and non-coplanar Step-and-shoot total scalp irradiation techniques were evaluated against the background of the literature. METHODS: Four patients (angiosarcoma, n=2, cutaneous B-cell non-Hodgkin lymphoma, B-NHL, n=1, mycosis fungoides, n=1) treated between 2008 and 2012 at our institution were retrospectively analyzed. For every patient with executed coplanar plan, a non-coplanar plan and vice versa has been calculated additionally for direct comparison. Three patients underwent limited surgery before radiotherapy. Individual adapted bolus material was used for every patient (helmet). Total scalp dose was 30 Gy (B-NHL, mycosis fungoides) and 50 Gy (angiosarcoma) with fractional doses of 2.0-2.5 Gy (without sequential local boost in three patients). Conformity and homogeneity indexes and dose volume histograms were used for treatment plan comparison. RESULTS: Dose hot spots were higher in coplanar plans (110-128% Dmax). Non-coplanar plans showed a more homogeneous dose distribution (HI = .12 - .17) and superior PTV coverage (88 - 96%). Target dose coverage was 81-117% in non-coplanar and 30-128% in coplanar plans. Coplanar plans yielded a stronger dose gradient across the target (.7-1.6 Gy/mm) compared to non-coplanar plans (.8-1.3 Gy/mm). The most conformal plan was a non-coplanar plan (CI = .7). Mean and maximum brain doses were comparable and showed an almost linear decrease between min. and max. dose. The optic chiasm and brain stem was spared most with non-coplanar plans, mean doses to the lenses ranged between 4 and 8 Gy and were higher in non-coplanar plans as were doses to the optic nerves.Radiotherapy tolerance was acceptable and acute side effects included erythema, scalp pain, alopecia and radiodermatitis which all spontaneously resolved. Two patients accomplished partial response, two patients showed complete response after radiotherapy. Three patients had locally controlled tumors without recurrence until their deaths or at last follow up, one patient had local progression shortly after radiotherapy. CONCLUSIONS: Photon-IMRT is an effective and feasible approach to treat extensive scalp malignancies. Non-coplanar beams could increase dose homogeneity and PTV coverage and might reduce doses particularly to the optic chiasm.


Assuntos
Hemangiossarcoma/radioterapia , Linfoma não Hodgkin/radioterapia , Micose Fungoide/radioterapia , Radioterapia de Intensidade Modulada/métodos , Couro Cabeludo , Neoplasias Cutâneas/radioterapia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fótons/uso terapêutico , Planejamento da Radioterapia Assistida por Computador/métodos , Estudos Retrospectivos , Couro Cabeludo/efeitos da radiação
20.
NMR Biomed ; 27(5): 561-9, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24664927

RESUMO

The combination of hyperpolarized MRS with diffusion weighting (dw) allows for determination of the apparent diffusion coefficient (ADC), which is indicative of the intra- or extracellular localization of the metabolite. Here, a slice-selective pulsed-gradient spin echo sequence was implemented to acquire a series of dw spectra from rat muscle in vivo to determine the ADCs of multiple metabolites after a single injection of hyperpolarized [1- ¹³C]pyruvate. An optimal control optimized universal-rotation pulse was used for refocusing to minimize signal loss caused by B1 imperfections. Non-dw spectra were acquired interleaved with the dw spectra and these were used to correct for signal decay during the acquisition as a result of T1 decay, pulse imperfections, flow etc. The data showed that the ADC values for [1- ¹³C]lactate (0.4-0.7 µm² /ms) and [1- ¹³C]alanine (0.4-0.9 µm² /ms) were about a factor of two lower than the ADC of [1- ¹³C]pyruvate (1.1-1.5 µm²/ms). This indicates a more restricted diffusion space for the former two metabolites consistent with lactate and alanine being intracellular. The higher ADC for pyruvate (similar to the proton ADC) reflected that the injected substance was not confined inside the muscle cells but also present extracellular.


Assuntos
Espectroscopia de Ressonância Magnética Nuclear de Carbono-13 , Metaboloma , Animais , Simulação por Computador , Difusão , Masculino , Músculos/metabolismo , Ratos Sprague-Dawley , Marcadores de Spin
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...