Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Eur J Heart Fail ; 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39113628

RESUMO

AIMS: Among patients with cardiogenic shock, immediate initiation of extracorporeal membrane oxygenation (ECMO) did not demonstrate any benefit at 30 days. The present study evaluated 1-year clinical outcomes of the Extracorporeal Membrane Oxygenation in the therapy of Cardiogenic Shock (ECMO-CS) trial. METHODS AND RESULTS: The ECMO-CS trial randomized 117 patients with severe or rapidly progressing cardiogenic shock to immediate initiation of ECMO or early conservative strategy. The primary endpoint for this analysis was 1-year all-cause mortality. Secondary endpoints included a composite of death, resuscitated cardiac arrest or implantation of another mechanical circulatory support device, duration of mechanical ventilation, and the length of intensive care unit (ICU) and hospital stays. In addition, an unplanned post-hoc subgroup analysis was performed. At 1 year, all-cause death occurred in 40 of 58 (69.0%) patients in the ECMO arm and in 40 of 59 (67.8%) in the early conservative arm (hazard ratio [HR] 1.02, 95% confidence interval [CI] 0.66-1.58; p = 0.93). The composite endpoint occurred in 43 (74.1%) patients in the ECMO group and in 47 (79.7%) patients in the early conservative group (HR 0.83, 95% CI 0.55-1.25; p = 0.29). The durations of mechanical ventilation, ICU stay and hospital stay were comparable between groups. Significant interaction with treatment strategy and 1-year mortality was observed in subgroups according to baseline mean arterial pressure (MAP) indicating lower mortality in the subgroup with low baseline MAP (<63 mmHg: HR 0.58, 95% CI 0.29-1.16; pinteraction = 0.017). CONCLUSIONS: Among patients with severe or rapidly progressing cardiogenic shock, immediate initiation of ECMO did not improve clinical outcomes at 1 year compared to the early conservative strategy. However, immediate ECMO initiation might be beneficial in patients with advanced haemodynamic compromise.

2.
J Interv Card Electrophysiol ; 67(1): 53-60, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36805921

RESUMO

BACKGROUND: Visually guided laser balloon ablation is known as an effective pulmonary vein (PV) isolation device. The third-generation laser balloon ablation system (X3) equipped with compliant balloon and an automated motor-driven laser output mechanism, namely RAPID mode, has been clinically proven for PV isolation. METHODS: PV isolation with X3 was performed in all the patients with paroxysmal and early-stage persistent atrial fibrillation (AF). Acute data for PV isolation and clinical outcomes including supraventricular tachyarrhythmia (SVT: AF, atrial flutter, or atrial tachycardia)-free survival rate beyond 1 year were analyzed. RESULTS: A total of 110 patients (62 ± 13 years old, 80% of paroxysmal AF) were treated with X3. RAPID mode with was utilized to achieve PV isolation in all cases. In combination with RAPID mode and spot mode laser ablation, 91.1% (380/417) of veins were isolated on the first circumferential lesion set and did not require touch-up ablation and during the index procedure 100% of attempted veins were isolated. The mean procedure time was 77.0 ± 22.7 min and LA dwell time was 61.9 ± 22.0 min. Total duration of laser application was 5.1 ± 2.3 min per vein. At 1 year, SVT-free survival rate was 93.7% in paroxysmal AF patients, and 81.1% in persistent AF patients. CONCLUSIONS: A novel continuous automatic laser balloon ablation system was proved to be safe and effective for both paroxysmal and persistent AF patients. The clinical result demonstrated that PV isolation with X3 could achieve a high SVT-free survival rate.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Terapia a Laser , Veias Pulmonares , Humanos , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Terapia a Laser/métodos , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos
3.
J Clin Med ; 12(16)2023 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-37629360

RESUMO

Transcatheter aortic valve replacement (TAVR) is a minimally invasive therapeutic procedure with a consistent, linear increase in the number of implantations worldwide. Recently, TAVR has been rapidly expanding into lower-risk populations. Sporadic cases of late prosthesis-related Stanford type A dissection have been documented in self-expanding, as well as balloon-expandable TAVR valves, manifested primarily as acute aortic syndrome. We present the case of a 76-year-old male, who experienced refractory in-hospital cardiac arrest with non-shockable rhythm due to the obstruction of coronary flow caused by aortic dissection type A, with entry directly adjacent to the aortic prosthesis according to autopsy. The patient died despite the engagement of extracorporeal cardiopulmonary resuscitation. Aortic dissection developed one year after a transfemoral TAVR procedure using an Edwards SAPIEN 3 29 mm self-expanding valve. TAVR-associated late aortic dissection type A represents a rare, life-threatening condition with various clinical manifestations. The risk factors have not been well described and the differential diagnosis may be challenging. As the number of TAVR recipients and their life expectancy is increasing, we may face this complication more often in future.

4.
Circulation ; 147(6): 454-464, 2023 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-36335478

RESUMO

BACKGROUND: Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is increasingly being used for circulatory support in patients with cardiogenic shock, although the evidence supporting its use in this context remains insufficient. The ECMO-CS trial (Extracorporeal Membrane Oxygenation in the Therapy of Cardiogenic Shock) aimed to compare immediate implementation of VA-ECMO versus an initially conservative therapy (allowing downstream use of VA-ECMO) in patients with rapidly deteriorating or severe cardiogenic shock. METHODS: This multicenter, randomized, investigator-initiated, academic clinical trial included patients with either rapidly deteriorating or severe cardiogenic shock. Patients were randomly assigned to immediate VA-ECMO or no immediate VA-ECMO. Other diagnostic and therapeutic procedures were performed as per current standards of care. In the early conservative group, VA-ECMO could be used downstream in case of worsening hemodynamic status. The primary end point was the composite of death from any cause, resuscitated circulatory arrest, and implementation of another mechanical circulatory support device at 30 days. RESULTS: A total of 122 patients were randomized; after excluding 5 patients because of the absence of informed consent, 117 subjects were included in the analysis, of whom 58 were randomized to immediate VA-ECMO and 59 to no immediate VA-ECMO. The composite primary end point occurred in 37 (63.8%) and 42 (71.2%) patients in the immediate VA-ECMO and the no early VA-ECMO groups, respectively (hazard ratio, 0.72 [95% CI, 0.46-1.12]; P=0.21). VA-ECMO was used in 23 (39%) of no early VA-ECMO patients. The 30-day incidence of resuscitated cardiac arrest (10.3.% versus 13.6%; risk difference, -3.2 [95% CI, -15.0 to 8.5]), all-cause mortality (50.0% versus 47.5%; risk difference, 2.5 [95% CI, -15.6 to 20.7]), serious adverse events (60.3% versus 61.0%; risk difference, -0.7 [95% CI, -18.4 to 17.0]), sepsis, pneumonia, stroke, leg ischemia, and bleeding was not statistically different between the immediate VA-ECMO and the no immediate VA-ECMO groups. CONCLUSIONS: Immediate implementation of VA-ECMO in patients with rapidly deteriorating or severe cardiogenic shock did not improve clinical outcomes compared with an early conservative strategy that permitted downstream use of VA-ECMO in case of worsening hemodynamic status. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02301819.


Assuntos
Oxigenação por Membrana Extracorpórea , Parada Cardíaca , Humanos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/terapia , Oxigenação por Membrana Extracorpórea/métodos , Hemodinâmica , Mortalidade Hospitalar , Estudos Retrospectivos
5.
J Pers Med ; 12(12)2022 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-36556249

RESUMO

Veno-venous extracorporeal membrane oxygenation (VV-ECMO) is a life-saving treatment for respiratory failure that may serve as a bridge to patient recovery or lung transplantation. In COVID-19, recovery is somewhat unpredictable and occasionally occurs after >100 days on VV-ECMO support. Thus, determining therapy cessation may be difficult. We report the case of a 59-year-old male without specific risk factors admitted to a tertiary center for rapidly progressive respiratory failure due to severe COVID-19, despite aggressive mechanical ventilatory support. Immediate insertion of VV-ECMO was associated with prompt resolution of hypoxemia and hypercapnia; however, all therapeutic efforts to wean the patient from VV-ECMO failed. During the prolonged hospitalization on VV-ECMO, sepsis was the most life-threatening complication. The patient overcame roughly 40 superinfections, predominantly affecting the respiratory tract, and spent 183 days on antimicrobial treatment. Although the function of other organ systems was generally stable, gradually progressive right ventricular dysfunction due to precapillary pulmonary hypertension required increasing doses of inotropes. A successful lung transplantation was performed after 207 days of VV-ECMO support. The present case provides evidence for prolonged VV-ECMO therapy as a bridge to lung transplantation in severe COVID-19 despite numerous, predominantly infectious complications.

6.
Sci Rep ; 12(1): 17076, 2022 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-36224296

RESUMO

Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is widely used in the treatment of patients experiencing cardiogenic shock (CS). However, increased VA-ECMO blood flow (EBF) may significantly impair left ventricular (LV) performance. The objective of the present study was to assess the effect of VA-ECMO on LV function in acute CS with concomitant severe aortic stenosis (AS) or mitral regurgitation (MR) in a porcine model. Eight female swine (45 kg) underwent VA-ECMO implantation under general anaesthesia and mechanical ventilation. Acute CS was induced by global myocardial hypoxia. Subsequently, severe AS was simulated by obstruction of the aortic valve, while severe MR was induced by mechanical destruction of the mitral valve. Haemodynamic and LV performance variables were measured at different rates of EBF rates (ranging from 1 to 4 L/min), using arterial and venous catheters, a pulmonary artery catheter, and LV pressure-volume catheter. Data are expressed as median (interquartile range). Myocardial hypoxia resulted in declines in cardiac output to 2.7 (1.9-3.1) L/min and LV ejection fraction to 15.2% (10.5-19.3%). In severe AS, increasing EBF from 1 to 4 L/min was associated with a significant elevation in mean arterial pressure (MAP), from 33.5 (24.2-34.9) to 56.0 (51.9-73.3) mmHg (P ˂ 0.01). However, LV volumes (end-diastolic, end-systolic, stroke) remained unchanged, and LV end-diastolic pressure (LVEDP) significantly decreased from 24.9 (21.2-40.0) to 19.1 (15.2-29.0) mmHg (P ˂ 0.01). In severe MR, increasing EBF resulted in a significant elevation in MAP from 49.0 (28.0-53.4) to 72.5 (51.4-77.1) mmHg (P ˂ 0.01); LV volumes remained stable and LVEDP increased from 17.1 (13.7-19.1) to 20.8 (16.3-25.6) mmHg (P ˂ 0.01). Results of this study indicate that the presence of valvular heart disease may alleviate negative effect of VA-ECMO on LV performance in CS. Severe AS fully protected against LV overload, and partial protection was also detected with severe MR, although at the cost of increased LVEDP and, thus, higher risk for pulmonary oedema.


Assuntos
Estenose da Valva Aórtica , Oxigenação por Membrana Extracorpórea , Insuficiência da Valva Mitral , Animais , Oxigenação por Membrana Extracorpórea/métodos , Feminino , Hipóxia , Insuficiência da Valva Mitral/terapia , Choque Cardiogênico/terapia , Suínos , Função Ventricular Esquerda/fisiologia
7.
Circulation ; 146(24): 1808-1819, 2022 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-36134574

RESUMO

BACKGROUND: Pulsed field ablation (PFA) has a unique safety profile when used to treat atrial fibrillation, largely related to its preferentiality for myocardial tissue ablation, in particular, esophageal sparing. A pentaspline catheter was the first such PFA system studied clinically for atrial fibrillation ablation; in these initial regulatory trials, the catheter was used for pulmonary vein isolation and left atrial posterior wall ablation. Since its regulatory approval in Europe, in clinical practice, physicians have ablated beyond pulmonary vein isolation and left atrial posterior wall ablation to expanded lesion sets in closer proximity to coronary arteries. This is an unstudied important issue because preclinical and clinical data have raised the potential for coronary arterial spasm. Herein, we studied the vasospastic potential of PFA lesion sets, both remote from and adjacent to coronary arteries. METHODS: During routine atrial fibrillation ablation using the pentaspline PFA catheter, coronary angiography was performed before, during, and after pulsed field applications. The lesion sets studied included: (1) those remote from the coronary arteries such as pulmonary vein isolation (n=25 patients) and left atrial posterior wall ablation (n=5), and (2) ablation of the cavotricuspid isthmus (n=20) that is situated adjacent to the right coronary artery. RESULTS: During pulmonary vein isolation and left atrial posterior wall ablation, coronary spasm did not occur, but cavotricuspid isthmus ablation provoked severe subtotal vasospasm in 5 of 5 (100%) consecutive patients, and this was relieved by intracoronary nitroglycerin in 5.5±3.5 minutes. ST-segment elevation was not observed. However, no patient (0%, P=0.004) had severe spasm if first administered parenteral nitroglycerin, either intracoronary (n=5) or intravenous (n=10), before treatment. CONCLUSIONS: Coronary vasospasm was not provoked during PFA at locations remote from coronary arteries, but when the energy is delivered adjacent to a coronary artery, PFA routinely provokes subclinical vasospasm. This phenomenon is attenuated by nitroglycerin, administered either post hoc to treat spasm or as prophylaxis.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Ablação por Cateter/efeitos adversos , Átrios do Coração , Nitroglicerina/uso terapêutico , Resultado do Tratamento
8.
Int J Mol Sci ; 24(1)2022 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-36613937

RESUMO

There are substantial differences in autonomic nervous system activation among heart (cardiac) failure (CF) patients. The effect of acute CF on autonomic function has not been well explored. The aim of our study was to assess the effect of experimental acute CF on heart rate variability (HRV). Twenty-four female pigs with a mean body weight of 45 kg were used. Acute severe CF was induced by global myocardial hypoxia. In each subject, two 5-min electrocardiogram segments were analyzed and compared: before the induction of myocardial hypoxia and >60 min after the development of severe CF. HRV was assessed by time-domain, frequency-domain and nonlinear analytic methods. The induction of acute CF led to a significant decrease in cardiac output, left ventricular ejection fraction and an increase in heart rate. The development of acute CF was associated with a significant reduction in the standard deviation of intervals between normal beats (50.8 [20.5−88.1] ms versus 5.9 [2.4−11.7] ms, p < 0.001). Uniform HRV reduction was also observed in other time-domain and major nonlinear analytic methods. Similarly, frequency-domain HRV parameters were significantly changed. Acute severe CF induced by global myocardial hypoxia is associated with a significant reduction in HRV.


Assuntos
Insuficiência Cardíaca , Isquemia Miocárdica , Feminino , Suínos , Animais , Frequência Cardíaca/fisiologia , Volume Sistólico , Função Ventricular Esquerda/fisiologia , Hipóxia
9.
J Cardiovasc Electrophysiol ; 32(5): 1367-1375, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33682228

RESUMO

INTRODUCTION: When cardiac magnetic resonance (MR) is performed after previous leadless transcatheter pacemaker implantation, an image distortion has to be expected in the heart region and evaluation of myocardial tissue can be affected. In this clinical prospective study, we aim to assess the extent and impact of this artifact on individual ventricular segments and compare it to conventional pacing devices. METHODS: Total of 20 patients with leadless pacemaker placed in the right ventricle underwent cardiac MR imaging in a 1.5 Tesla scanner. A multiplanar segmentation was used to demarcate the left and right ventricular myocardium as well as the pacemaker-caused image artifact in systolic and diastolic time frames. Artifact size and its relative influence on myocardial segments were quantitatively assessed and expressed in AHA-17 model. RESULTS: Implanted leadless pacemaker caused an image artifact with a volume of 48 ± 5 ml. Most distorted were the apical septal (53 ± 23%), apical inferior (30 ± 18%), and midventricular inferoseptal (30 ± 20%) segments. The artifact intersection with basal and lateral segments was none or negligible (up to 2%). The portion of left ventricular (LV) myocardium affected by the artifact was significantly higher in systole (8 ± 4%) compared to diastole (10 ± 3%; p < .001). CONCLUSION: Implantation of leadless pacemaker represents no obstacle for cardiac MR imaging but causes an image artifact located mostly in septal, inferoseptal, and anteroseptal segments of apical and midventricular LV myocardium. With the exception of the apex, diastolic timing reduces the image distortion of all segments and improves global ventricular assessment.


Assuntos
Artefatos , Marca-Passo Artificial , Coração , Humanos , Espectroscopia de Ressonância Magnética , Estudos Prospectivos
10.
Mol Cell Biochem ; 476(3): 1313-1326, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33387216

RESUMO

The assessment and monitoring of the tissue perfusion is extremely important in critical conditions involving circulatory shock. There is a wide range of established methods for the assessment of cardiac output as a surrogate of oxygen delivery to the peripheral tissues. However, the evaluation of whether particular oxygen delivery is sufficient to ensure cellular metabolic demands is more challenging. In recent years, specific biochemical parameters have been described to indicate the status between tissue oxygen demands and supply. In this review, the authors summarize the application of some of these biochemical markers, including mixed venous oxygen saturation (SvO2), lactate, central venous-arterial carbon dioxide difference (PCO2 gap), and PCO2 gap/central arterial-to-venous oxygen difference (Ca-vO2) for hemodynamic assessment of tissue perfusion. The thorough monitoring of the adequacy of tissue perfusion and oxygen supply in critical conditions is essential for the selection of the most appropriate therapeutic strategy and it is associated with improved clinical outcomes.


Assuntos
Microcirculação , Monitorização Fisiológica/métodos , Oxigênio/metabolismo , Artérias/metabolismo , Biomarcadores/metabolismo , Dióxido de Carbono , Glucose/metabolismo , Hemodinâmica , Humanos , Hipóxia , Ácido Láctico , Consumo de Oxigênio , Perfusão , Prognóstico , Espectroscopia de Luz Próxima ao Infravermelho
11.
JACC Clin Electrophysiol ; 6(14): 1744-1751, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33357570

RESUMO

OBJECTIVES: The authors report their single-center experience with the retrieval and replacement of long-term implanted leadless cardiac pacemakers (LPs) and the factors contributing to success. BACKGROUND: LPs are a clinically effective and safe alternative to standard transvenous pacemakers for single-chamber ventricular pacing. However, the feasibility of retrieving and replacing long-term implanted LPs is not well known. METHODS: A total of 34 patients with implanted Nanostim LPs (mean implantation duration 1,570 ± 479 days) subsequently underwent retrieval. On the basis of fluoroscopic imaging, the cohort was divided into 2 groups: those with remarkable swinging movement (SM) of the LP docking button (n = 25) and those without SM (n = 9). RESULTS: The overall LP retrieval success rate was 85% (n = 29). New leadless devices were implanted in 27 patients immediately after LP retrieval. No procedure-related adverse events occurred. The rate of successful LP retrieval was significantly higher in the SM group (25 of 25 [100%]) than in the no-SM group (4 of 9 [44%]) (p < 0.001), and fluoroscopy time during the retrieval procedure was shorter in the SM group (12.7 ± 8.6 min) than in the no-SM group (45.6 ± 19 min) (p < 0.001). CONCLUSIONS: This study demonstrated the feasibility and safety of retrieval of long-term implanted LPs after a mean duration of 4 years. Retrieval was most successful in patients whose docking buttons exhibited significant SM.


Assuntos
Marca-Passo Artificial , Desenho de Equipamento , Fluoroscopia , Humanos , Marca-Passo Artificial/efeitos adversos , Próteses e Implantes
12.
JACC Case Rep ; 2(14): 2249-2252, 2020 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-34317150

RESUMO

This is the first report of the management of a patient with cardiac resynchronization therapy using leadless biventricular pacing. Successful retrieval of a 4-year-old Micra transcatheter pacing system (TPS) and reimplantation of a new Micra TPS prevented device-to-device interactions from multiple pacing devices in the right ventricle. (Level of Difficulty: Advanced.).

13.
Crit Care ; 23(1): 364, 2019 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-31752966

RESUMO

BACKGROUND: Continuous, reliable evaluation of left ventricular (LV) contractile function in patients with advanced heart failure requiring intensive care remains challenging. Continual monitoring of dP/dtmax from the arterial line has recently become available in hemodynamic monitoring. However, the relationship between arterial dP/dtmax and LV dP/dtmax remains unclear. This study aimed to determine the relationship between arterial dP/dtmax and LV dP/dtmax assessed using echocardiography in patients with acute heart failure. METHODS: Forty-eight patients (mean age 70.4 years [65% male]) with acute heart failure requiring intensive care and hemodynamic monitoring were recruited. Hemodynamic variables, including arterial dP/dtmax, were continually monitored using arterial line pressure waveform analysis. LV dP/dtmax was assessed using continuous-wave Doppler analysis of mitral regurgitation flow. RESULTS: Values from continual arterial dP/dtmax monitoring were significantly correlated with LV dP/dtmax assessed using echocardiography (r = 0.70 [95% confidence interval (CI) 0.51-0.82]; P < 0.0001). Linear regression analysis revealed that LV dP/dtmax = 1.25 × (arterial dP/dtmax) (P < 0.0001). Arterial dP/dtmax was also significantly correlated with stroke volume (SV) (r = 0.63; P < 0.0001) and cardiac output (CO) (r = 0.42; P = 0.0289). In contrast, arterial dP/dtmax was not correlated with SV variation, dynamic arterial elastance, heart rate, systemic vascular resistance (SVR), or mean arterial pressure. Markedly stronger agreement between arterial and LV dP/dtmax was observed in subgroups with higher SVR (N = 28; r = 0.91; P <  0.0001), lower CO (N = 26; r = 0.81; P <  0.0001), and lower SV (N = 25; r = 0.60; P = 0.0014). A weak correlation was observed in the subjects with lower SVR (N = 20; r = 0.61; P = 0.0004); in the subgroups with higher CO (N = 22) and higher SV (N = 23), no significant correlation was found. CONCLUSION: Our results suggest that in patients with acute heart failure requiring intensive care with an arterial line, continuous calculation of arterial dP/dtmax may be used for monitoring LV contractility, especially in those with higher SVR, lower CO, and lower SV, such as in patients experiencing cardiogenic shock. On the other hand, there was only a weak or no significant correlation in the subgroups with higher CO, higher SV, and lower SVR.


Assuntos
Ecocardiografia Doppler/métodos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca/fisiologia , Contração Miocárdica/fisiologia , Função Ventricular Esquerda/fisiologia , Idoso , Idoso de 80 Anos ou mais , Débito Cardíaco/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto
14.
PLoS One ; 13(4): e0196321, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29689088

RESUMO

INTRODUCTION: Veno-arterial extracorporeal life support (ECLS) is increasingly being used to treat rapidly progressing or severe cardiogenic shock. However, it has been repeatedly shown that increased afterload associated with ECLS significantly diminishes left ventricular (LV) performance. The objective of the present study was to compare LV function and coronary flow during standard continuous-flow ECLS support and electrocardiogram (ECG)-synchronized pulsatile ECLS flow in a porcine model of cardiogenic shock. METHODS: Sixteen female swine (mean body weight 45 kg) underwent ECLS implantation under general anesthesia and artificial ventilation. Subsequently, acute cardiogenic shock, with documented signs of tissue hypoperfusion, was induced by initiating global myocardial hypoxia. Hemodynamic cardiac performance variables and coronary flow were then measured at different rates of continuous or pulsatile ECLS flow (ranging from 1 L/min to 4 L/min) using arterial and venous catheters, a pulmonary artery catheter, an LV pressure-volume loop catheter, and a Doppler coronary guide-wire. RESULTS: Myocardial hypoxia resulted in declines in mean cardiac output to 1.7±0.7 L/min, systolic blood pressure to 64±22 mmHg, and LV ejection fraction (LVEF) to 22±7%. Synchronized pulsatile flow was associated with a significant reduction in LV end-systolic volume by 6.2 mL (6.7%), an increase in LV stroke volume by 5.0 mL (17.4%), higher LVEF by 4.5% (18.8% relative), cardiac output by 0.37 L/min (17.1%), and mean arterial pressure by 3.0 mmHg (5.5%) when compared with continuous ECLS flow at all ECLS flow rates (P<0.05). At selected ECLS flow rates, pulsatile flow also reduced LV end-diastolic pressure, end-diastolic volume, and systolic pressure. ECG-synchronized pulsatile flow was also associated with significantly increased (7% to 22%) coronary flow at all ECLS flow rates. CONCLUSION: ECG-synchronized pulsatile ECLS flow preserved LV function and coronary flow compared with standard continuous-flow ECLS in a porcine model of cardiogenic shock.


Assuntos
Circulação Coronária/fisiologia , Modelos Animais de Doenças , Oxigenação por Membrana Extracorpórea/métodos , Fluxo Pulsátil/fisiologia , Choque Cardiogênico/terapia , Suínos , Função Ventricular Esquerda/fisiologia , Animais , Vasos Coronários/fisiopatologia , Eletrocardiografia/métodos , Feminino , Hemodinâmica , Cuidados para Prolongar a Vida/métodos , Choque Cardiogênico/patologia , Choque Cardiogênico/fisiopatologia
15.
Crit Care ; 21(1): 172, 2017 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-28687073

RESUMO

BACKGROUND: Despite marked advances in intensive cardiology care, current options for outcome prediction in cardiac arrest survivors remain significantly limited. The aim of our study was, therefore, to compare the day-specific association of neuron-specific enolase (NSE) with outcomes in out-of-hospital cardiac arrest (OHCA) survivors treated with hypothermia. METHODS: Eligible patients were OHCA survivors treated with targeted temperature management at 33 °C for 24 h using an endovascular device. Blood samples for NSE levels measurement were drawn on days 1, 2, 3, and 4 after hospital admission. Thirty-day neurological outcomes according to the Cerebral Performance Category (CPC) scale and 12-month mortality were evaluated as clinical end points. RESULTS: A total of 153 cardiac arrest survivors (mean age 64.2 years) were enrolled in the present study. Using ROC analysis, optimal cutoff values of NSE for prediction of CPC 3-5 score on specific days were determined as: day 1 > 20.4 mcg/L (sensitivity 63.3%; specificity 82.1%; P = 0.002); day 2 > 29.0 mcg/L (72.5%; 94.4%; P < 0.001); and day 3 > 20.7 mcg/L (94.4%; 86.7%; P < 0.001). The highest predictive value, however, was observed on day 4 > 19.4 mcg/L (93.5%; 91.0%; P < 0.001); NSE value >50.2 mcg/L at day 4 was associated with poor outcome with 100% specificity and 42% sensitivity. Moreover, NSE levels measured on all individual days also predicted 12-month mortality (P < 0.001); the highest predictive value for death was observed on day 3 > 18.1 mcg/L (85.3%; 72.0%; P < 0.001). Significant association with prognosis was found also for changes in NSE at different time points. An NSE level on day 4 > 20.0 mcg/L, together with a change > 0.0 mcg/L from day 3 to day 4, predicted poor outcome (CPC 3-5) with 100% specificity and 73% sensitivity. CONCLUSIONS: Our results suggest that NSE levels are a useful tool for predicting 30-day neurological outcome and long-term mortality in OHCA survivors treated with targeted temperature management at 33 °C. The highest associations of NSE with outcomes were observed on day 4 and day 3 after cardiac arrest.


Assuntos
Parada Cardíaca Extra-Hospitalar/mortalidade , Fosfopiruvato Hidratase/análise , Medição de Risco/métodos , Idoso , Biomarcadores/análise , Biomarcadores/sangue , Feminino , Humanos , Unidades de Terapia Intensiva/organização & administração , Unidades de Terapia Intensiva/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Modelos Neurológicos , Exame Neurológico/métodos , Fosfopiruvato Hidratase/sangue , Prognóstico , Estudos Prospectivos , Curva ROC
16.
Eur J Heart Fail ; 19 Suppl 2: 124-127, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28470919

RESUMO

AIMS: Extracorporeal membrane oxygenation (ECMO) in veno-arterial configuration represents an increasingly used method for circulatory support. ECMO in cardiogenic shock offers rapid improvement of circulatory status and significant increase in tissue perfusion. Current evidence on the use of ECMO in cardiogenic shock remains insufficient. The aim of the ECMO-CS trial is to compare two recognized therapeutic approaches in the management of severe cardiogenic shock: early conservative therapy and early implantation of veno-arterial ECMO on the background of standard care. METHODS: Eligible patients have either rapidly deteriorating or severe cardiogenic shock, defined using echocardiography, hemodynamic and metabolic criteria. Patients are randomized to the one of two arms: immediate veno-arterial ECMO therapy or early conservative therapy. All other diagnostic and therapeutic procedures are performed as per current standard of care, including other cardiovascular interventions (i.e. percutaneous coronary intervention or cardiac surgery). Follow-up includes visits at 30 days, 6 months and 12 months. Primary endpoint is a composite of death from any cause, resuscitated circulatory arrest, and implantation of another mechanical circulatory support device at 30 days. The sample size of 120 individuals (60 in each arm) provides 80% power to detect 50% reduction of primary endpoint, at alpha = 0.05. Patient recruitment started in October 2014. CONCLUSION: The results of the ECMO-CS trial may significantly influence current practice in the management of patients with severe and rapidly deteriorating cardiogenic shock. ECMO-CS trial registration number is NCT02301819.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Insuficiência Cardíaca/terapia , Hemodinâmica/fisiologia , Seleção de Pacientes , Choque Cardiogênico/terapia , Idoso , Feminino , Seguimentos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Choque Cardiogênico/complicações , Choque Cardiogênico/fisiopatologia , Resultado do Tratamento
17.
J Am Heart Assoc ; 5(10)2016 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-27680664

RESUMO

BACKGROUND: Transcatheter left atrial appendage closure is an alternative therapy for stroke prevention in atrial fibrillation patients. These procedures are currently guided with transesophageal echocardiography and fluoroscopy in most centers. As intracardiac echocardiography (ICE) is commonly used in other catheter-based procedures, we sought to determine the safety and effectiveness of intracardiac echocardiography-guided left atrial appendage closure with the Watchman device. METHODS AND RESULTS: A total of 27 patients (11 males, 77.0±8.5 years) with atrial fibrillation receiving Watchman left atrial appendage closure under intracardiac echocardiography guidance at a single center were investigated. All patients were implanted successfully. There were no major procedural complications. The overall procedure-related complication rate was 14.8%, mainly due to access site hematoma. Transesophageal echocardiography demonstrated successful closure of the left atrial appendage in all patients at 45 days after device implant. CONCLUSIONS: Transcatheter left atrial appendage closure with intracardiac echocardiography guidance is safe and feasible.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Técnicas de Imagem Cardíaca/métodos , Ecocardiografia Transesofagiana/métodos , Próteses e Implantes , Acidente Vascular Cerebral/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Cateterismo Cardíaco , Ecocardiografia/métodos , Procedimentos Endovasculares , Estudos de Viabilidade , Feminino , Humanos , Cuidados Intraoperatórios , Masculino , Acidente Vascular Cerebral/etiologia , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento
18.
J Cardiovasc Electrophysiol ; 27 Suppl 1: S29-37, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26969220

RESUMO

INTRODUCTION: Catheter ablation is an effective treatment of scar-related ventricular tachycardia (VT), but the overall complexity of the procedure has precluded its widespread use. Remote magnetic navigation (RMN) has been shown to facilitate cardiac mapping and ablation of VT in a retrospective series. STOP-VT is the first multicenter, prospective, single-arm and single-procedure study evaluating RMN-based mapping and ablation of post-infarction VT. METHODS: Patients with documented VT and prior MI, in whom an ICD was implanted either for primary or secondary prevention, were recruited from four EU and US centers. Either a transseptal (48 patients) or transaortic (5 patients) approach was employed to gain access for ventricular endocardial mapping/ablation during VT (entrainment mapping, activation mapping) and/or substrate mapping in sinus rhythm (elimination of fractionated/late potentials, variable extent of substrate modification) with RMN and irrigated RF ablation. The primary endpoints were as follows: (i) non-inducibility of the target VT or any other sustained VT; (ii) elimination of sustained VT/VF during ICD follow-up of up to 12 months. RESULTS: The cohort included 53 consecutive patients (median age 67 years, 49 men, median LVEF 31%). One hemodynamically unstable patient was excluded at the onset of mapping. Inducibility of sustained VT was achieved an average of 2.2 times per patient (1-8), with mean tachycardia cycle length (TCL) 374 milliseconds (179-510). Mean total procedure and fluoroscopy times were 223 minutes and 8.7 minutes, respectively; mean cumulative fluoroscopy time during mapping and ablation was 0.95 minutes; maximum power averaged 42.3 W with nominal saline 30 cc/min irrigation; mean cumulative RF time was 38 minutes. Non-inducibility of the target VT was achieved in 49/52 patients (94.2%) and non-inducibility of any VT was achieved in 38/52 patients (73.1%). A combination of RMN and manual ablation was performed in two patients, rendering one non-inducible. During the 12-month ICD follow-up period, freedom from any sustained VT/VF was observed in 30 patients (62%), of which 19 (63%) were off antiarrhythmic medications. Five patients expired during follow-up: one presented with a VT storm, but for the others, death was not related to VT/VF (MI-cardiogenic shock, pulmonary embolism, bronchogenic carcinoma, end stage heart failure). No procedural complications were reported. CONCLUSIONS: This first prospective, single-procedure, multicenter study indicates that remote magnetic navigation is a safe and effective method for catheter ablation of post-infarction VT.


Assuntos
Ablação por Cateter/métodos , Internacionalidade , Fenômenos Magnéticos , Procedimentos Cirúrgicos Robóticos/métodos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Idoso , Estudos de Coortes , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
19.
Artif Organs ; 40(4): 353-9, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26412075

RESUMO

The protective effects of ischemic postconditioning (IPC) and nitric oxide (NO) administration have been demonstrated in several ischemic scenarios. However, current evidence regarding the effect of IPC and NO in extracorporeal cardiopulmonary resuscitation remains lacking. Fifteen female swine (body weight 45 kg) underwent veno-arterial extracorporeal membrane oxygenation (ECMO) implantation; cardiac arrest-ventricular fibrillation was induced by rapid ventricular pacing. After 20 min of cardiac arrest, blood flow was restored by increasing the ECMO flow rate to 4.5 L/min. The animals (five per group) were then randomly assigned to receive IPC (three cycles of 3 min ischemia and reperfusion), NO (80 ppm via oxygenator), or mild hypothermia (HT; 33.0°C). Cerebral oximetry and aortic blood pressure were monitored continuously. After 90 min of reperfusion, blood samples were drawn for the measurement of troponin I, myoglobin, creatine-phosphokinase, alanine aminotransferase, neuron-specific enolase, cystatin C, and reactive oxygen metabolite (ROM) levels. Significantly higher blood pressure and cerebral oxygen saturation values were observed in the HT group compared with the IPC and NO groups (P < 0.05). The levels of troponin I, myoglobin, creatine phosphokinase, and alanine aminotransferase were significantly lower in the HT group (P < 0.05); levels of neuron-specific enolase, cystatin C, and ROM were not significantly different. IPC and NO were comparable in all monitored parameters. The results of the present study indicate that IPC and NO administration are not superior interventions to HT for the maintenance of blood pressure, cerebral oxygenation, organ protection, and suppression of oxidative stress following extracorporeal cardiopulmonary resuscitation.


Assuntos
Reanimação Cardiopulmonar/métodos , Oxigenação por Membrana Extracorpórea/métodos , Pós-Condicionamento Isquêmico/métodos , Óxido Nítrico/uso terapêutico , Substâncias Protetoras/uso terapêutico , Alanina Transaminase/sangue , Animais , Pressão Sanguínea , Creatina Quinase/sangue , Cistatina C/sangue , Modelos Animais de Doenças , Feminino , Mioglobina/sangue , Estresse Oxidativo , Fosfopiruvato Hidratase/sangue , Espécies Reativas de Oxigênio/sangue , Suínos , Troponina I/sangue
20.
J Interv Card Electrophysiol ; 44(3): 265-71, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26475792

RESUMO

PURPOSE: We evaluated the correlation between pulmonary venous (PV) anatomy and acute and long-term success of PV isolation (PVI) with two balloon-based ablation catheter techniques. METHODS: One hundred consecutive patients were analyzed in two equal groups treated with either the second-generation cryoballoon (CRYO) catheter or the visually guided laser ablation (VGLA) catheter. All patients underwent multi-detector computed tomography (CT) imaging. The primary and secondary efficacy endpoints were the procedural achievement of proven electrical isolation of all veins and freedom from atrial fibrillation (AF) within a 1-year follow-up period, respectively. RESULTS: Variant PV anatomy was observed in 32% of patients in the CRYO group and in 40% of patients in the VGLA group. All PVs were targeted with either the CRYO catheter (n = 199) or the VGLA catheter (n = 206). One hundred ninety-three of 199 PVs (97%) were successfully isolated in the CRYO group and 194 of 206 PVs (94%) in the VGLA group (p = 0.83). Over a 12-month follow-up, AF recurrence was documented in 11/45 (24%) and 7/43 (16%) patients in the CRYO and the VGLA groups, respectively (p = 0.21). In the CRYO group, a larger left inferior PV size was associated with worse long-term outcome (p = 0.001). In the VGLA group, a larger left superior PV size (p = 0.003) and more oval right inferior PV were associated with worse acute success (p = 0.038). There was no absolute cutoff between PV anatomy and clinical success. CONCLUSIONS: The variability of PV anatomy did not significantly compromise acute success of PVI or patient outcomes.


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Criocirurgia/instrumentação , Terapia a Laser/instrumentação , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Sistema de Condução Cardíaco/diagnóstico por imagem , Sistema de Condução Cardíaco/efeitos da radiação , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Radiografia , Resultado do Tratamento , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA