Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Transfusion ; 60(8): 1804-1810, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32339301

RESUMO

BACKGROUND: A single, simplified approach for human immunodeficiency virus (HIV)-1/HIV-2 antibody confirmation/differentiation is needed for the HIV blood donation supplemental algorithm used in the United States. A clinical evaluation of the Geenius assay was performed-the same assay used for HIV diagnostic confirmation/differentiation in the United States since 2014. STUDY DESIGN AND METHODS: Well-characterized unlinked donation samples classified as HIV negative, false positive, or confirmed positive were included in the study: 200 antibody-nonreactive, 200 HIV-1 immunofluorescence assay (IFA) confirmed-positive, and 100 antibody-screen false-positive donations, equally divided between serum and plasma. Samples were retrieved from a repository, relabeled, and tested by an immunochromatographic test (Geenius HIV 1/2 Supplemental Assay, Bio-Rad). Comparator testing involved parallel US Food and Drug Administration (FDA)-licensed HIV-1 IFA or HIV-2 enzyme immunoassay (EIA) supplemental testing for any sample missing those results as part of routine testing (otherwise test-of-record results were used). Samples with discordant results were further tested with a rapid test (Multispot HIV-1/HIV-2 Rapid Test, Bio-Rad) to provide final sample interpretations. Testing volume reductions with the Geenius were estimated from screening performed by the American Red Cross from September 2016 to April 2019. RESULTS: Clinical results were 100% sensitivity and specificity with an indeterminate rate of 4.0% to 5.0%. From 2016 to 2019, sole use of the Geenius would reduce testing complexity for 5265 antibody repeat-reactive donations including 95.7% (5028) false positives, eliminating approximately 5000 unnecessary tests. CONCLUSION: Geenius FDA licensure (August 26, 2019) adding the HIV-1/HIV-2 differentiation/confirmation donation supplemental claim will enable replacement of previously used FDA-licensed supplemental assays while maintaining comparable sensitivity, avoiding thousands of unnecessary HIV-1-IFA, western blot, and HIV-2-EIA tests.


Assuntos
Algoritmos , Doadores de Sangue , Seleção do Doador , Anticorpos Anti-HIV/sangue , Infecções por HIV/sangue , HIV-1 , HIV-2 , Feminino , Humanos , Imunoensaio , Técnicas Imunoenzimáticas , Masculino , Estados Unidos , United States Food and Drug Administration
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...