Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
1.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1528847

RESUMO

This study aimed to compare the subgingival microbiota of subjects with and without breast cancer (BC). Patients with BC (Group 1; n= 50) and without BC (Group 2; n=50) with periodontitis (A) and without periodontitis (B). The study was conducted in two phases (P1 and P2). One biofilm sample was collected from each subject and analyzed by DNA-DNA Hybridization (Checkerboard DNA-DNA). The relative abundance of the subgingival microbiota differed between the Case and Control groups. However, some species were higher in patients in the Case than in Control subjects and differed between the groups in both phases. Composition of the subgingival microbial community according to the Socransky complex was related to periodontal disease, followed by clinical attachment of level (CAL ≥4mm), age, and tooth loss, which were found to be abundant in Cases when compared with controls. Patients with Tumor Grade II and III had a higher prevalence of tooth loss and CAL≥4mm. It was concluded that in individuals with BC, the sub-gingival microbiota exhibited atypical changes, but they developed periodontal disease.


El objetivo de este estudio fue comparar la microbiota subgingival de sujetos con y sin cáncer de mama (CM). Pacientes con CM (Grupo 1; n= 50) y sin CM (Grupo 2; n=50) con periodontitis (A) y sin periodontitis (B). El estudio se realizó en das fases (P1 y P2). Se recogió una muestra de biopelícula de cada sujeto y se analizó mediante hibridación ADN-ADN (tablero de ajedrez ADN-ADN). La abundancia relativa de la microbiota subgingival difirió entre los grupos de Caso y Control. Sin embargo, algunas especies fueron más altas en los pacientes del Caso que en los sujetos del Control y difirieron entre los grupos en ambas fases. La composición de la comunidad microbiana subgingival según el complejo de Socransky se relacionó con la enfermedad periodontal, seguida por el nivel de inserción clínica (CAL≥4mm), la edad y la pérdida de dientes, que se mostró abundante en los casos en comparación con los controles. Los pacientes con Tumor Grado II y III tuvieron mayor prevalencia de pérdida dental y CAL≥4mm. Se concluyó que en individuos con CM la microbiota subgingival presentó cambios atípicos, pero sin embargo, desarrollaron enfermedad periodontal.

2.
Int. j. odontostomatol. (Print) ; 17(3): 356-371, sept. 2023. ilus, tab, graf
Artigo em Inglês | LILACS | ID: biblio-1514380

RESUMO

The present study aimed to review the literature on the main complications of antineoplastic therapies and the degree of knowledge of dental surgeons about these complications. A bibliographic search was conducted in the main health databases PUBMED (www.pubmed.gov) and Scholar Google (www.scholar.google.com.br), in which studies published from 1987 to 2023 were collected. Laboratory studies, case reports, systematic and literature reviews, which were developed in living individuals, about the main neoplastic genes and their relationship with the cells of individuals affected by neoplasms in the head and neck region, and studies on the care with this group of patients, were included. Therefore, articles that did not deal with neoplasm and the main complications of antineoplastic therapies were excluded. Neoplasm is a clonal disorder, caused by mutations, resulting from changes in the genetic structure of cells. Each healthy cell has instructions on how to grow and divi de. In the presence of any error in these instructions (mutation), it can result in a diseased cell that, when proliferating, may cause a tumor. Countless knowledge has been accumulated over the years on the main characteristics of neoplasms, whether they are cancer cell biology, carcinogenesis mechanism, neoplasms of the maxillofacial system and sequels of antineoplastic treatments. In this context, methods have been developed that offer a better quality of life for patients diagnosed with this pathology, as well as preventive vaccine models that may, in the not too distant future, contribute to this goal to be successfully achieved.


El presente estudio tuvo como objetivo revisar la literatura sobre las principales complicaciones de las terapias antineoplásicas y el grado de conocimiento de los odontólogos sobre este abordaje. Se realizó una búsqueda bibliográfica en las principales bases de datos de salud PUBMED (www.pubmed.gov) y Scholar Google (www.scholar.google.com.br), en la que se recopilaron estudios publicados entre 1987 y 2023. Fueron incluidos estudios de laboratorio, relatos de casos, revisiones de la literatura y revisiones sistemáticas, desarrolladas en individuos vivos, que incluyeran los principales genes neoplásicos y su relación con las células de individuos afectados por neoplasias en la cabeza y el cuello. También, se tuvieron en cuenta estudios relacionados con la atención a este grupo de pacientes. La neoplasia es un trastorno clonal, causado por mutaciones, como resultado de cambios en la estructura genética de las células. Cada célula sana tiene instrucciones sobre cómo crecer y dividirse. En presencia de cualquier error en estas instrucciones (mutación), puede provocar una célula alterada que, al proliferar, puede causar un tumor. Se han acumulado innumerables conocimientos a lo largo de los años sobre las principales características de las neoplasias, ya sea sobre biología de células cancerosas, el mecanismo de la carcinogénesis, la neoplasias del sistema maxilofacial y las diferentes secuelas de tratamientos antineoplásicos. En este contexto, se han desarrollado métodos que ofrecen una mejor calidad de vida para los pacientes diagnosticados con esta patología, así como modelos de vacunas preventivas que, en un futuro no muy lejano, pueden contribuir a alcanzar este objetivo con éxito.


Assuntos
Humanos , Assistência Odontológica , Genes Neoplásicos/genética , Neoplasias de Cabeça e Pescoço/genética
3.
Int. j. odontostomatol. (Print) ; 17(3): 245-250, sept. 2023. ilus
Artigo em Inglês | LILACS | ID: biblio-1514376

RESUMO

This article aims to describe a clinical case of the use of the injectable restorative technique with composite resin in a patient with an esthetic complaint in the anterior teeth. Producing direct restorations in anterior teeth when performed with composite resin demands a long clinical time. Results often depend on the operator's ability to reproduce proper form, function, and esthetics. Lately, the versatility of composite resins has increased. As this material evolved, new techniques were introduced to simplify the restorative process and save time. The restorative technique with injectable fluid composite resin, in addition to delivering faster and with a certain ease, is capable of increasing the predictability of treatment results. However, it is known that flowable resins have lower wear resistance and color stability compared to conventional resins. Thus, a version of this material with a higher filler content in its composition was introduced to the market, to improve wear resistance and gloss retention. Long-term studies evaluating the use of low-viscosity resins are needed. The injectable technique can accurately reproduce the morphology obtained in the wax-up of the case, generating a satisfactory esthetic and functional result. Despite simplifying the fabrication of restorations when compared to the conventional technique, it is still necessary for the operator to have some experience and aptitude. The clinical time for the production of restorations has been considerably reduced. The material showed good flow, shine, and polish in the immediate result. However, the finishing and polishing of the restorations required a longer clinical period than usual and in the short- term follow-up, flaws in the gingival margins and a new finishing and polishing procedure were necessary. Therefore, the technique described in this article can be considered a restorative alternative, but it is still not able to replace the tradit ional method of making previous esthetic restorations.


Este artículo tiene como objetivo describir un caso clínico del uso de la técnica restauradora inyectable con resina compuesta en un paciente con una queja estética en los dientes anteriores. Producir restauraciones directas en dientes anteriores cuando se realizan con resina compuesta demanda un largo tiempo clínico. Los resultados a menudo dependen de la capacidad del operador para reproducir la forma, la función y la estética adecuadas. Últimamente, la versatilidad de las resinas compuestas ha aumentado. A medida que este material evolucionó, se introdujeron nuevas técnicas para simplificar el proceso de restauración y ahorrar tiempo. La técnica restauradora con resina compuesta fluida inyectable, además de una entrega más rápida y segura, es capaz de aumentar la previsibilidad de los resultados del tratamiento. Sin embargo, se sabe que las resinas fluidas tienen menor resistencia al desgaste y estabilidad del color en comparación con las resinas convencionales. Así, se introdujo en el mercado una versión de este material con un mayor contenido de relleno en su composición, con el objetivo de mejorar la resistencia al desgaste y la retención del brillo. Se necesitan estudios a largo plazo que evalúen el uso de resinas de baja viscosidad. La técnica inyectable es capaz de reproducir fielmente la morfología obtenida en el encerado del caso, generando un resultado estético y funcional satisfactorio. A pesar de simplificar la fabricación de restauraciones en comparación con la técnica convencional, todavía es necesario que el operador tenga cierta experiencia y aptitud. El tiempo clínico para la producción de restauraciones se ha reducido considerablemente. El material mostró buena fluidez, brillo y pulido en el resultado inmediato. Sin embargo, el acabado y pulido de las restauraciones requirió de un período de tiempo clínico más largo de lo habitual y en el seguimiento a corto plazo, fueron necesarios defectos en los márgenes gingivales y un nuevo procedimiento de acabado y pulido. Por lo tanto, la técnica descrita en este artículo puede considerarse una alternativa restauradora, pero aún no es capaz de reemplazar el método tradicional de realizar restauraciones estéticas previas.


Assuntos
Humanos , Masculino , Adulto , Resinas Compostas , Restauração Dentária Permanente/métodos , Facetas Dentárias , Estética Dentária
4.
Int. j. odontostomatol. (Print) ; 17(2): 174-185, jun. 2023. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1440356

RESUMO

This in silico study aimed to evaluate the biomechanical behavior of a full-arch implant-supported prosthesis on titanium and zirconia monotype implants. A 3D mandible containing 1.0 mm thick cortical and cancellous bone was modeled. Four dental implants (3.3 x 10 mm) were inserted into the jaw model in each model. The implants consisted of Titanium (Ti-S group) and Zirconia Monotype/one-piece (Zr-S group). Fixed full-arch implant-supported prostheses were cemented onto the implant. The models were exported to the analysis software and divided into meshes composed of nodes and tetrahedral elements. All materials were considered isotropic, elastic, and homogeneous. Therefore, all contacts were considered bonded, the mandible model was fixed in all directions, applying a static structural axial load of 300 N on the bottom of the fossa of the left mola r teeth. Microstrain and von-Mises stress (MPa) were adopted as failure criteria. Comparable stress and strain values were shown in the peri-implant bone for both groups. However, the Ti-S group presented a lower stress value (1,155.8 MPa) than the Zr-S group (1,334.2 MPa). Regarding bone tissues, the Ti-S group presented 612 µε and the Zr-S group presented 254 µε. The highest strain peak was observed in bone tissues around the implant closer to the load for both groups. Evaluating monotype zirconia and titanium implants, it is suggested that the greater the rigidity of the implant, the greater the concentration of internal stre sses and the less dissipation to the surrounding tissues. Therefore, monotype ceramic implants composed of yttrium-stabilized tetragonal polycrystalline zirconia may be a viable alternative to titanium implants for full-arch prostheses.


El objetivo de este estudio in silico fue evaluar el comportamiento biomecánico de una prótesis implanto soportada de arcada completa sobre implantes monotipo de titanio y zirconia. Se modeló una mandíbula en 3D que contenía tejido óseo cortical y esponjoso de 1,0 mm de espesor. En cada modelo, se insertaron cuatro implantes dentales (3,3 x 10 mm) en el modelo de mandíbula. Los implantes consistieron en Monotipo de Titanio y Zirconia. Sobre el implante se cementaron prótesis implanto soportadas de arcada completa fija. Los modelos se exportaron al software de análisis y se dividieron en mallas compuestas por nodos y elementos tetraédricos. Todos los materiales se consideraron isotrópicos, elásticos y homogéneos. Por lo tanto, todos los contactos se consideraron cementados, el modelo mandibular se fijó en todas las direcciones, aplicando una carga vertical estructural estática de 300 N en el fondo de la fosa de los dientes molares izquierdos. Se seleccionaron la microesfuerzo y la tensión de Von-Mises (MPa) como criterios de falla. Se mostraron valores de tensión y deformación comparables en el hueso periimplantario para ambos grupos. Sin embargo, el grupo Ti-S presentó un valor de estrés menor (1.155,8 MPa) que el grupo Zr-S (1.334,2 MPa). En cuanto a los tejidos óseos, el grupo Ti-S presentó 612 µε y el grupo Zr-S presentó 254 µε. La mayor concentración de deformación en el tejido óseo se observó en los tejidos alrededor del implante más cerca de la carga para ambos grupos. Al evaluar los implantes monotípicos de zirconia y titanio, se sugiere que cuanto mayor sea la rigidez del implante, mayor será la concentración de tensiones internas y menor la disipación a los tejidos circundantes. Por lo tanto, los implantes cerámicos monotipo compuestos de zirconia policristalina tetragonal estabilizada con itrio pueden ser una alternativa viable a los implantes de titanio para prótesis de arcada completa.


Assuntos
Implantes Dentários , Materiais Dentários , Estresse Mecânico , Fenômenos Biomecânicos , Análise de Elementos Finitos , Mandíbula/diagnóstico por imagem
5.
Int. j. odontostomatol. (Print) ; 17(2): 142-154, jun. 2023. tab, ilus
Artigo em Inglês | LILACS | ID: biblio-1440352

RESUMO

The present study proposed to describe, through a literature review, the use of new therapeutic management which allows for offering a better quality of life to individuals affected by these pathologies. A bibliographic search was conducted in the main health databases PUBMED (www.pubmed.gov) and Scholar Google (www.scholar.google.com.br), in which studies published from 1987 to 2023 were collected. In the first stage, the list of retrieved articles was examined by reading the titles and abstracts. In the second stage, the studies were selected by reading the full contents. Two authors (JDMM and DAQ) performed stages 1 and 2. Experimental, clinical, case-control, randomized controlled, and laboratory cohort studies, case reports, systematic reviews, and literature reviews, which were developed in living individuals, were included. Therefore, articles that did not deal with the subject in question, letters to the editor, opinion articles, duplicated literature in databases, and literature that did not address the variables under study, we re excluded. Contemporary dentistry uses alternative treatments capable of improving the patient's condition since a cure is not always possible. Therefore, the possibility of improving the quality of life becomes an important point to be reached. Evidence-based healthcare has made great advances in recent decades, especially in the areas of orofacial pain, TMD, and occlusion, especially related to orthodontic, prosthetic, and restorative care.


En el presente estudio se propuso describir, a través de una revisión bibliográfica, el uso de nuevos manejos terapéuticos que permitan brindar una mejor calidad de vida a los individuos afectados por estas patologías. Se realizó una búsqueda bibliográfica en las principales bases de datos de salud PUBMED (www.pubmed.gov) y Scholar Google (www.scholar.google.com.br), en las que se recopilaron estudios publicados entre 1987 y 2023. En la primera etapa, se examinó la lista de artículos recuperados mediante la lectura de los títulos y resúmenes. En la segunda etapa, los estudios fueron seleccionados mediante la lectura del contenido completo. Dos autores (JDMM y DAQ) realizaron las etapas 1 y 2. Se incluyeron estudios de cohortes experimentales, clínicos, de casos y controles, controlados aleatorios y de laboratorio, informes de casos, revisiones sistemáticas y revisiones de la literatura, que se desarrollaron en individuos vivos. Por lo tanto, se excluyeron artículos que no trataran el tema en cuestión, cartas al editor, artículos de opinión, literatura duplicada en bases de datos y literatura que no abordara las variables en estudio. La odontología contemporánea utiliza tratamientos alternativos capaces de mejorar el estado del paciente, ya que no siempre es posible la curación. Por lo tanto, la posibilidad de mejorar la calidad de vida se convierte en un objetivo importante. La atención médica basada en la evidencia ha logrado grandes avances en las últimas décadas, especialmente en las áreas de dolor orofacial, TMD y oclusión, especialmente en relación con la atención de ortodoncia, prótesis y restauración.


Assuntos
Humanos , Dor Facial/terapia , Transtornos da Articulação Temporomandibular/terapia , Terapia por Acupuntura/métodos , Estimulação Elétrica Nervosa Transcutânea/métodos
6.
J Esthet Restor Dent ; 35(6): 927-936, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37203879

RESUMO

PURPOSE: The aim of this study was to evaluate staining layer behavior applied to high-translucency zirconia (YZHT), feldspathic ceramics (FD), and zirconia-reinforced lithium silicate (ZLS) surfaces against different antagonists. METHODS AND MATERIALS: Monolithic ceramic discs (n = 120) (ø 12 mm; thickness, 1.2 mm; ISO 6872) were obtained, 30 from YZHT and FD, and 60 from ZLS CAD/CAM blocks (staining layer applied before or after the crystallization procedure). The specimens were divided into 12 subgroups (n = 10) according to the antagonists: steatite, polymer-infiltrated ceramic, or zirconia. Mechanical cycling (1.5 × 104 cycles; 15 N; horizontal displacement, 6 mm; 1.7 Hz) and flexural strength tests (1 mm/min-1000 kg cell) were performed. The differences between final and initial roughnesses (Ra, Rz, and Rsm), the mass loss, and the flexural strength data were individually analyzed by two-way ANOVA and Tukey's test (α = 0.05). RESULTS: The roughnesses of all ceramics did not present a statistically significant difference before wear simulation: Ra (p = 0.3348), Rz (p = 0.5590), and Rsm (p = 0.5330). After the wear simulation, the Ra parameter was not affected by an interaction between ceramic and antagonist (p = 0.595). The Rz and Rsm parameters were affected only by the antagonist pistons (both, p = 0.000). The ceramics used in this study showed statistically significant differences in mass loss after the wear test (p < 0.0001). The additional firing (2 steps) of the ZLS2 led to a higher lost mass quantity. CONCLUSION: All ceramics presented similar initial roughnesses and similar roughnesses after the wear simulation. The zirconia antagonist showed better performance against ceramics with high crystalline content. CLINICAL SIGNIFICANCE: It is clear that restorative materials must be carefully selected by dental practitioners according to indications, properties, and antagonists. The steatite antagonist, that is, an enamel analog, showed better performance against vitreous ceramics, while the zirconia antagonist showed better performance against ceramics with high crystalline content. Wear affects the surface roughnesses of the ceramics. Additional firing for the staining of the zirconia-reinforced lithium silicate ceramic led to a greater loss of mass.


Assuntos
Porcelana Dentária , Lítio , Humanos , Porcelana Dentária/química , Odontólogos , Teste de Materiais , Papel Profissional , Cerâmica/química , Zircônio/química , Silicatos , Propriedades de Superfície , Desenho Assistido por Computador
7.
Braz. dent. sci ; 26(2): 1-10, 2023. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1436570

RESUMO

The maxillary bone restriction can limit the implants position to support a full-arch prosthesis. Objective:Therefore, this study evaluated the biomechanical behavior of a full-arch prosthesis supported by six implants in different configurations: group A (implants inserted in the region of canines, first premolars and second molars), group B (implants inserted in the region of first premolar, first molar and second molar) and group C (implants in second premolar, first premolar and second molar). Material and Methods: The models were analyzed by the finite element method validated by strain gauge. Three types of loads were applied: in the central incisors, first premolars and second molars, obtaining results of von-Mises stress peaks and microstrain. All registered results reported higher stress concentration in the prosthesis of all groups, with group C presenting higher values in all structures when compared to A and B groups. The highest mean microstrain was also observed in group C (288.8 ± 225.2 µÎµ/µÎµ), however, there was no statistically significant difference between the evaluated groups. In both groups, regardless of the magnitude and direction of the load, the maximum von-Mises stresses recorded for implants and prosthesis displacements were lower in group A. Conclusion: It was concluded that an equidistant distribution of implants favors biomechanical behavior of full-arch prostheses supported by implants; and the placement of posterior implants seems to be a viable alternative to rehabilitate totally edentulous individuals. (AU)


A limitação óssea maxilar totais pode limitar o posicionamento dos implantes para suportar uma prótese de arco total. Objetivo: Sendo assim, este estudo avaliou o comportamento biomecânico de uma prótese de arco total suportada por seis implantes em diferentes configurações: grupo A (implantes inseridos na região de caninos, primeiros pré-molares e segundos molares), grupo B (implantes inseridos na região de primeiro pré-molar, primeiro molar e segundo molar) e grupo C (implantes em segundo pré-molar, primeiro pré-molar e segundo molar). Materiais e métodos: Os modelos foram analisados pelo método de elementos finitos validados por extensometria. Foram aplicados três tipos de cargas: nos incisivos centrais, primeiros pré-molares e nos segundos molares, obtendo resultados de picos de tensão de von-Mises e microdeformação. Todos os resultados registrados mostraram maior concentração de tensão na prótese de todos os grupos, sendo que o grupo C apresentou maiores valores em todas as estruturas quando comparado com os grupos A e B. A maior média de microdeformação também foi observada no grupo C (288,8 ± 225,2 µÎµ/µÎµ), no entanto, não houve diferença estatisticamente significativa entre os grupos avaliados. Em todos os grupos, independentemente da magnitude e direção da carga, as tensões máximas de von-Mises registradas para os implantes e deslocamentos de próteses foram menores no grupo A. Conclusão: Concluiu-se que a distribuição de implantes de forma equidistante favorece o desempenho biomecânico das próteses de arco total suportada por implantes; e o posicionamento de implantes posteriores parece ser uma alternativa viável para reabilitar indivíduos densdentados totais. (AU)


Assuntos
Fenômenos Biomecânicos , Implantes Dentários , Prótese Dentária , Análise de Elementos Finitos , Maxila
8.
Materials (Basel) ; 15(22)2022 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-36431619

RESUMO

The present study aimed to evaluate the biomechanical behavior of PEEK abutments with different heights on single titanium implants. To investigate the implant surface, different tests (scanning electron microscopy, energy-dispersive X-ray, and X-ray diffraction) were adopted. Herein, 20 implants received the 4.5 × 4.0 mm PEEK short abutment (SA) and 20 received the 4.5 × 5.5 mm PEEK long abutment (LA). The abutments were installed using dual-cure resin cement. To determine the fatigue test, two specimens from each group were submitted to the single load fracture test. For this, the samples were submitted to a compressive load of (0.5 mm/min; 30°) in a universal testing machine. For the fatigue test, the samples received 2,000,000 cycles (2 Hz; 30°). The number of cycles and the load test was analyzed by the reliability software SPSS statistics using Kaplan-Meier and Mantel-Cox tests (log-rank) (p < 0.05). The maximum load showed no statistically significant differences (p = 0.189) for the SA group (64.1 kgf) and the LA group (56.5 kgf). The study groups were statistically different regarding the number of cycles (p = 0.022) and fracture strength (p = 0.001). PEEK abutments can be indicated with caution for implant-supported rehabilitation and may be suitable as temporary rehabilitation.

9.
Materials (Basel) ; 15(18)2022 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-36143553

RESUMO

This study aimed to evaluate the biomechanical behavior of Morse taper implants using different abutments (CMN abutment [(CMN Group] and miniconical abutments [MC Group]), indicated to support a screw-retained 3-unit fixed partial denture. For the in vitro test, polyurethane blocks were fabricated for both groups (n = 10) and received three implants in the "offset" configuration and their respective abutments (CMN or MC) with a 3-unit fixed partial denture. Four strain gauges were bonded to the surface of each block. For the finite element analysis, 3D models of both groups were created and exported to the analysis software to perform static structural analysis. All structures were considered homogeneous, isotropic, and elastic. The contacts were considered non-linear with a friction coefficient of 0.3 between metallic structures and considered bonded between the implant and substrate. An axial load of 300 N was applied in three points (A, B, and C) for both methods. The microstrain and the maximum principal stress were considered as analysis criteria. The obtained data were submitted to the Mann-Whitney, Kruskal-Wallis, and Dunn's multiple comparison test (α = 5%). The results obtained by strain gauge showed no statistical difference (p = 0.879) between the CMN (645.3 ± 309.2 µÎµ) and MC (639.3 ± 278.8 µÎµ) and allowed the validation of computational models with a difference of 6.3% and 6.4% for the microstrains in the CMN and MC groups, respectively. Similarly, the results presented by the computational models showed no statistical difference (p = 0.932) for the CMN (605.1 ± 358.6 µÎµ) and MC (598.7 ± 357.9 µÎµ) groups. The study concluded that under favorable conditions the use of CMN or MP abutments to support a fixed partial denture can be indicated.

10.
Dent J (Basel) ; 10(8)2022 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-36005243

RESUMO

This study aimed to evaluate the use of bioengineering tools, finite element analysis, strain gauge analysis, photoelastic analysis, and digital image correlation, in computational studies with greater validity and reproducibility. A bibliographic search was performed in the main health databases PUBMED and Scholar Google, in which different studies, among them, laboratory studies, case reports, systematic reviews, and literature reviews, which were developed in living individuals, were included. Therefore, articles that did not deal with the use of finite element analysis, strain gauge analysis, photoelastic analysis, and digital image correlation were excluded, as well as their use in computational studies with greater validity and reproducibility. According to the methodological analysis, it is observed that the average publication of articles in the Pubmed database was 2.03 and with a standard deviation of 1.89. While in Google Scholar, the average was 0.78 and the standard deviation was 0.90. Thus, it is possible to verify that there was a significant variation in the number of articles in the two databases. Modern dentistry finds in finite element analysis, strain gauge, photoelastic and digital image correlation a way to analyze the biomechanical behavior in dental materials to obtain results that assist to obtain rehabilitations with favorable prognosis and patient satisfaction.

11.
Materials (Basel) ; 15(15)2022 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-35955276

RESUMO

This study aimed to evaluate the influence of thermomechanical cycling (TMC) and type of abutment on the misfit and compressive strength of the implant−abutment interface. Forty 3.75-mm external hexagon implants with 25° angled abutments were divided into four groups (N = 10). Group A: overcast plus TMC; Group B: overcast without TMC; Group C: completely cast plus TMC; Group D: completely cast without TMC. Abutments were fixed to the implants with 32-Ncm torque, and groups A and C specimens were cyclically loaded at 80 N with 2 Hz for 1 million cycles. The misfit on the implant−abutment interface was evaluated by optical microscope (100×) and the compressive strength test was performed in a universal test machine. For statistical analysis, a two-way ANOVA and post hoc Tukey test were used. There was no difference in misfit presented by all the abutments in the absence of TMC (p > 0.05). When TMC was performed, the completely cast abutments showed greater misfit than overcast ones (p = 0.001). Regarding compressive strength, irrespective of TMC performed, the overcast abutments showed higher compressive strength values than completely cast abutments (p = 0.003). Moreover, disregarding the type of abutment used, the absence of TMC provided higher compressive strength values (p < 0.001). It was concluded that thermomechanical cyclic loading aggravated the misfit, especially in completely cast abutments, regardless of material or fabrication technique, and reduced the compressive strength of the two types of abutments tested.

12.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1385891

RESUMO

ABSTRACT: The aim of this study was to evaluate the dental and periodontal condition of alcohol-dependents from a Brazilian Recovery Center. Sixty male individuals (30 alcoholic and 30 non-alcoholic) and aged between 32 and 72 years old were clinically evaluated. Interviews, dental and periodontal clinical examinations were obtained from all participants. The Pearson Chi-Square Test and Exact Fisher test were used to compare categorical data. The t-Student's test was adopted for non-categorical data. Multiple logistic regressions were used to evaluate the association of variables in the groups. The alcoholics were younger, consumed more tobacco, had lower frequency of tooth brushing and dental flossing, higher number of missing and decayed teeth, more residual root, and more teeth with presence of visible plaque index (OR = 0.5, 95 % Cl = 4.4 to 5.5), when compared to the non-alcoholics. Alcoholics at the Recovery Center performed poor oral hygiene, had higher number of sites with periodontal disease, and worse oral hygiene than non-alcoholic individuals. As regards professional follow-up, there was similarity between the groups evaluated.


RESUMEN: El objetivo de este estudio fue evaluar las condiciones dentales y periodontales de los alcohólicos de un Centro de Recuperación de Brasil. Sesenta hombres (30 alcohólicos y 30 no alcohólicos) y con edades comprendidas entre 32 y 72 años fueron evaluados clínicamente. Se obtuvieron entrevistas, exámenes clínicos dentales y periodontales de todos los participantes. La prueba de Chi-cuadrado de Pearson y la prueba exacta de Fisher se utilizaron para comparar datos categóricos. La prueba de t-Student se adoptó para datos no categóricos. Se utilizaron regresiones logísticas múltiples para evaluar la asociación de variables en los grupos. Los alcohólicos eran más jóvenes, consumían más tabaco, tenían menor frecuencia de cepillado dental y uso de hilo dental, mayor número de dientes perdidos y cariados, más raíz residual y más dientes con presencia de índice de placa visible (OR = 0,5, 95 % Cl = 4,4 a 5,5), en comparación con los no alcohólicos. Los alcohólicos en el Centro de Recuperación realizan una mala higiene bucal, tenían un mayor número de sitios con enfermedad periodontal y una peor higiene bucal que los no alcohólicos. En cuanto al seguimiento profesional, hubo similitud entre los grupos evaluados.

13.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1385868

RESUMO

ABSTRACT: The most common failure in implantology are due to mechanical instability. Torque loosening or fracture of the screws are the most frequent complications. Furthermore, the fractured screw retrieval is complicated and time-consuming. So, modifications in the design of implant systems are justifiable to offer a greater degree of biomechanical stability. Thus, the present study proposes to evaluate an experimental geometry for abutment screw regarding failure probability and torque loss. Twenty implant/abutments sets (e-fix, A.S. Technology - Titanium Fix) were divided into the following groups (n=10 in each group): (1) Conventional screw (Screw neck ø 1.5 mm) and (2) Experimental screw (screw neck constricted ø 1.2 mm). The abutments were tightened with a controlled torque meter device following the manufacturer's recommendations. Mechanical cycling was carried out with a load of 50 N.cm during 5 x 10 6 cycles with a frequency of 2 Hz at a temperature of 37°C (ISO 14801). A digital torque meter was used to measure the reverse torque values of the prosthetic screw and the micro abutment screw, before and after loading. Data were statistically analyzed by One-way Anova and Tukey test (95 %). The results of the mean values of torque loss of the micro abutment screw were 58.44 % for the control group and 55.31 % for the experimental group and the mean torque loss for the prosthetic screw was 53.3 % and 61.3 % of the conventional and experimental groups, respectively. The survival probability was 100 % for both screw groups. It was concluded that experimental screw showed a similar behavior to conventional screws, showing similar reliability after fatigue life testing.


RESUMEN: En implantología las fallas más habituales se deben a la inestabilidad mecánica. El aflojamiento del torque o la fractura de los tornillos son las complicaciones más frecuentes. Además, la recuperación del tornillo fracturado es complicada y requiere mucho tiempo. Por tanto, las modificaciones en el diseño de los sistemas de implantes están justificados para ofrecer un mayor grado de estabilidad biomecánica. Por lo tanto, el presente estudio propone evaluar una geometría experimental para tornillo de pilar en cuanto a probabilidad de falla y pérdida de torque. Se dividieron veinte conjuntos de implantes / pilares (e-fix, AS Technology - Titanium Fix) en los siguientes grupos (n = 10 en cada grupo): (1) Tornillo convencional (cuello de tornillo ø 1,5 mm) y (2) Tornillo experimental (cuello de rosca estrechado ø 1,2 mm). Los pilares se apretaron con un dispositivo medidor de torque controlado siguiendo las recomendaciones del fabricante. El ciclo mecánico se realizó con una carga de 50 N.cm durante 5 x 10 6 ciclos con una frecuencia de 2 Hz a una temperatura de 37° C (ISO 14801). Se utilizó un medidor de torque digital para medir los valores de torque inverso del tornillo protésico y el tornillo de micro pilar, antes y después de la carga. Los datos se analizaron estadísticamente mediante la prueba One-way Anova y Tukey (95%). Los resultados de los valores medios de pérdida de torque del micro tornillo de pilar fueron 58,44 % para el grupo de control y 55,31 % para el grupo experimental y la pérdida de torque media para el tornillo protésico fue 53,3 % y 61,3 % de los grupos convencional y experimental, respectivamente. La probabilidad de supervivencia fue del 100 % para ambos grupos de tornillos. Se concluyó que el tornillo experimental mostró un comportamiento similar a los tornillos convencionales, mostrando una fiabilidad similar después de la prueba de vida a fatiga.

14.
Dent J (Basel) ; 10(1)2022 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-35049610

RESUMO

This study evaluated the influence of distal implants angulation and framework material in the stress concentration of an All-on-4 full-arch prosthesis. A full-arch implant-supported prosthesis 3D model was created with different distal implant angulations and cantilever arms (30° with 10-mm cantilever; 45° with 10-mm cantilever and 45° with 6-mm cantilever) and framework materials (Cobalt-chrome [CoCr alloy], Yttria-stabilized tetragonal zirconia polycrystal [Y-TZP] and polyetheretherketone [PEEK]). Each solid was imported to computer-aided engineering software, and tetrahedral elements formed the mesh. Material properties were assigned to each solid with isotropic and homogeneous behavior. The contacts were considered bonded. A vertical load of 200 N was applied in the distal region of the cantilever arm, and stress was evaluated in Von Misses (σVM) for prosthesis components and the Maximum (σMAX) and Minimum (σMIN) Principal Stresses for the bone. Distal implants angled in 45° with a 10-mm cantilever arm showed the highest stress concentration for all structures with higher stress magnitudes when the PEEK framework was considered. However, distal implants angled in 45° with a 6-mm cantilever arm showed promising mechanical responses with the lowest stress peaks. For the All-on-4 concept, a 45° distal implants angulation is only beneficial if it is possible to reduce the cantilever's length; otherwise, the use of 30° should be considered. Comparing with PEEK, the YTZP and CoCr concentrated stress in the framework structure, reducing the stress in the prosthetic screw.

15.
Comput Methods Biomech Biomed Engin ; 25(3): 239-246, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34559574

RESUMO

This study aimed to evaluate the biomechanical behavior, stress distributions and bone microstrain of fixed partial dentures (FPD) with ceramic abutments supported on monotype zirconia implants, titanium implants and two-piece zirconia implants, using finite element analysis. A three-dimensional model of the jaw was simulated containing 1.0 mm thick cortical bone and cancellous bone tissue. A FPD and implant models (4.1 x 10 mm) were modeled containing a cement-retained implant abutment. These models were replicated in three groups with similar geometries: Titanium Implant and Zirconia Abutment (Ti-Zr); Zirconia Implant and Zirconia Abutment (Zr-Zr) and Monotype Zirconia Implant (Zr-S). An axial load of 300 N was applied to the center of the first premolar. The microstrain (µÎµ) and the Von-Mises stress (MPa) were assumed as failures criteria. For the three groups, a higher stress concentration was observed in the region of FPD connectors. The Ti-Zr group showed a higher stress concentration in the prosthesis and implant when compared to the other groups. However, the smaller elastic modulus of the titanium implant, in relation to the zirconia, provided a lower stress in the abutment and in the prosthetic screw. The monotype implant system allowed a more homogeneous stress distribution and its strain were predominantly located in the cervical region of the peri-implant bone tissue. Monotype or two-piece zirconia implants can be used for rehabilitation with FPD. However, the absence of separation between implant and abutment in the monotype system avoids the stress concentration in the prosthetic screw and reduced the peri-implant bone strain.


Assuntos
Implantes Dentários , Dente Suporte , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Prótese Parcial Fixa , Análise de Elementos Finitos , Estresse Mecânico , Titânio , Zircônio
16.
Braz. dent. sci ; 25(4): 1-9, 2022. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1410540

RESUMO

Aim: To describe through a clinical case report the surgical sequence of rehabilitation with 3D-printed implants associated with maxillary sinus floor lift with synthetic regenerative materials, including biphasic bioceramic. Case Report: Patient had an agenesis of the upper left premolars (#12 and #13), a vertical bone deficiency caused by maxillary sinus' pneumatization, and a horizontal alveolar resorption around the missing teeth area. During the surgical procedures, incisions, detachment, and osteotomy were performed in the lateral region of the maxillary sinus. The sinus membrane was detached and lifted 10 mm. Then, a thick poly(dioxanone)-based synthetic resorbable membrane (Plenum) was inserted and adapted inside the sinus to protect the sinus membrane. After the osteotomies with sub-instrumentation, 3D-printed implants (Plenum) were installed in the #12 area (3.5mm x 11.5 mm; 30N) and #13 area (4.0mm x 10mm; 20N). The maxillary sinus was entirely filled with a biphasic bioceramic, HA/ß-TCP (70:30) 500-1000 µm (Plenum) and covered by the same synthetic resorbable membrane. Connective tissue graft from the palatal area was positioned internally to the flap and stabilized with sutures to improve the vestibular tissue architecture. The entire surgical wound was sutured, and the tissues stabilized. No complications occurred in the postoperative period. Conclusion: The use of synthetic regenerative memberane and 3D-printed implants seems to be a promising option in areas of deficient bone remnants (AU)


Objetivo: Descrever por meio de um relato de caso clínico a sequência cirúrgica de reabilitação com implantes obtidos por impressão 3D associados à elevação do assoalho do seio maxilar com materiais regenerativos sintéticos, incluindo uma biocerâmica bifásica. Relato de Caso: Paciente apresentava agenesia dos pré-molares superiores esquerdos (24 e 25), deficiência óssea vertical causada pela pneumatização do seio maxilar e reabsorção alveolar horizontal ao redor da área dos dentes ausentes. Durante os procedimentos cirúrgicos foram realizados incisões, descolamento e osteotomia na região lateral do seio maxilar. A membrana sinusal foi descolada e elevada 10 mm. Em seguida, uma membrana reabsorvível sintética à base de poli(dioxanona) espessa (Plenum) foi inserida e adaptada dentro do seio para proteger a membrana do seio. Após as osteotomias com subinstrumentação, implantes impressos em 3D (Plenum) foram instalados na área do 24 (3,5mm x 11,5mm; 30N) e na área do 25 (4,0mm x 10mm; 20N). O seio maxilar foi inteiramente preenchido com biocerâmica bifásica, HA/ß-TCP (70:30)500-1000 µm (Plenum) e recoberto pela mesma membrana sintética reabsorvível. O tecido conjuntivo da região palatina foi posicionado internamente ao retalho e estabilizado com suturas para melhorar a arquitetura do tecido vestibular. Toda a ferida cirúrgica foi suturada e os tecidos estabilizados. Não ocorreram complicações no pós-operatório. Conclusão:A utilização de biomateriais regenerativos sintéticos e implantes impressos parece ser uma opção promissora em áreas de remanescentes ósseos deficientes.(AU)


Assuntos
Humanos , Masculino , Adulto , Implantes Dentários , Transplante de Tecidos , Levantamento do Assoalho do Seio Maxilar , Impressão Tridimensional , Seio Maxilar
17.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1385835

RESUMO

ABSTRACT: To evaluate the stresses generated in upper premolars rehabilitated with ceramic fragments (table-top) of lithium disilicate on the occlusal surface. An upper premolar was modeled following its anatomical references using computer aided design software (Rhinoceros version 5.0 SR8, USA). The dental tissues were individually designed containing enamel, dentin and periodontal ligament. The main anatomical points were used as parameters for model creation. Ceramic fragments were modeled varying their maximum thicknesses as: 0.5 mm, 1.0 mm and 1.5 mm. Solid geometries were exported to the analysis software (ANSYS 17.2, USA) in STEP format. The materials were considered isotropic, homogeneous and linear, and the values of the elastic modulus of the materials and structures were used to perform a static structural mechanical analysis. The set was submitted to 200 N load. The system fixation was defined on the basis of the three- dimensional model, and the results were obtained in MPa according to the failure criteria of the analyzed materials (tensile stress). Occlusal restoration was not detrimental to mechanical behavior. Stress distribution in the internal region of the restoration was similar between the groups. Thicker fragments presented a lower concentration of tensile stress, therefore suggesting better prognosis in attenuating tensile stresses in the tooth region. More conservative occlusal ceramic fragments presented worse prognosis. However, all evaluated thickness for table-tops support the occlusal rehabilitation of upper premolars when submitted to 200 N loading.


RESUMEN: El objetivo fue evaluar las tensiones generadas en los premolares superiores rehabilitados con fragmentos cerámicos (tablero) de disilicato de litio en la superficie oclusal. Se modeló un premolar superior siguiendo sus referencias anatómicas utilizando un software de diseño asistido por computadora (Rhinoceros versión 5.0 SR8, EE. UU.). Los tejidos dentales se moldearon individualmente conteniendo esmalte, dentina y ligamento periodontal. Los principales puntos anatómicos se utilizaron como parámetros para la creación del modelo. Los fragmentos cerámicos se modelaron variando sus espesores máximos como: 0,5 mm, 1,0 mm y 1,5 mm. Las geometrías sólidas se exportaron al software de análisis (ANSYS 17.2, EE. UU.) En formato STEP. Los materiales se consideraron isotrópicos, homogéneos y lineales, y los valores del módulo elástico de los materiales y estructuras se utilizaron para realizar un análisis mecánico estructural estático. El conjunto se sometió a una carga de 200 N. La fijación del sistema se definió a partir del modelo tridimensional, y los resultados se obtuvieron en MPa según los criterios de falla de los materiales analizados (tensión de tracción). La restauración oclusal no perjudica el comportamiento mecánico. La distribución de la tensión en la región interna de la restauración es similar entre los grupos. Los fragmentos más gruesos presentaron una menor concentración de tensión de tracción, lo que sugiere un mejor pronóstico en la atenuación de las tensiones de tracción en la región dentaria. Los fragmentos cerámicos oclusales más conservadores presentaron peor pronóstico. Sin embargo, todos los espesores evaluados para tableros de mesa en disilicato de litio apoyan la rehabilitación oclusal de los premolares superiores cuando se someten a una carga de 200 N.

18.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1385842

RESUMO

ABSTRACT: The aim of this study was to evaluate the influence of overtorque on integrity, strength and stress on external hexagonal implants (EH), with two different grades (N=10): conventional (C), grade 4; and modified (M), grade 4 with thermal treatment. The dimensions of EH were 3.75 x 13 mm; the specimens were fixed and submitted to SEM analysis and image acquisition. The abutment was then retained with 70 N/cm, re-analyzed by SEM, and a second image was obtained. The images were analyzed by Image J software (1.44o- NIH, USA) for dimensional variations measurement on surface of the hexagonal area. The finite element method was applied with a similar compliance to calculate the resultant stress (MPa) during the torque. Results were statistically analyzed with t-student test (5 %). The dimensional accuracy of M (0.22 mm2) was statistically significant (p<0.05). Minimum principal stress and von-Mises stress of C (-19.95 MPa, -19.94 MPa), were lower than M values (-55.83 MPa, -55.96 MPa), respectively. However, the M group showed lower deformation than C group. Therefore, more rigid titanium alloy is a promising alternative to avoid plastic deformation of prosthetic connec tions even concentrating higher stress magnitude on its structure.


RESUMEN: El objetivo de este estudio fue evaluar la influencia del sobrepar en la integridad, la fuerza y la tensión en los implantes hexagonales externos (EH), con dos grados diferentes (N = 10): convencional (C), grado 4; y modificado (M), grado 4 con tratamiento térmico. Las dimensiones de EH eran 3,75 de diámetro x 13 mm de longitud; las muestras se fijaron y se sometieron a análisis SEM y adquisición de imágenes. A continuación, el pilar se retuvo con 70 N / cm, se volvió a analizar por SEM y se obtuvo una segunda imagen. Las imágenes se analizaron con el software Image J (1.44o-NIH, EE. UU.) Para medir las variaciones dimensionales en la superficie superior del área hexagonal, que fue causada por un par excesivo. El método de los elementos finitos se aplicó con un cumplimiento similar para calcular la tensión resultante (MPa) durante el par. Los resultados se analizaron estadísticamente con la prueba t-student (5 %). La precisión dimensional de M (0,22 mm2) fue estadísticamente significativa (p <0,05). La tensión principal mínima y la tensión de von-Mises de C (-19,95 MPa, -19,94 MPa), fueron inferiores a los valores de M (-55,83 MPa, -55,96 MPa), respectivamente. Sin embargo, el hexágono del grupo M mostró menor deformación que el grupo C. Por lo tanto, la aleación de titanio más rígida es una alternativa prometedora para evitar la deformación plástica de las conexiones protésicas incluso concentrando una mayor magnitud de tensión en su estructura.

19.
PLoS One ; 16(10): e0258131, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34644314

RESUMO

The present article examines the impact of intellectual property (IP) utilization and concentration on economic growth in Mexico. The findings presented center on the use of different forms of IP by researchers in the National System of Researchers (SNI in Spanish) of Mexico. We focus especially on the externalities associated with the use of IP by researchers, as well as on understanding how knowledge about, and utilization of IP relates to economic growth, as measured by gross domestic product (GDP). The results of our analyses indicate that in the context of the Mexican SNI, the utilization of certain forms of IP, specifically patents and industrial designs, had a positive impact on economic growth, while the use of utility models was negatively linked to drivers of growth. Policies based on these results could seek to foster awareness and utilization of particular forms of IP by SNI researchers, which in turn could result in greater economic growth in Mexico.


Assuntos
Propriedade Intelectual , Conhecimento , Pesquisadores , Humanos , México
20.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1385780

RESUMO

ABSTRACT: The present study aims to describe through a literature review, the main types of noble and non-noble alloys in dentistry looking to identify the adhesion mechanisms, compositions and mechanical properties, and its applicability as a rehabilitation resource nowadays. A bibliographic search was conducted in the main health databases PUBMED (www.pubmed.gov) and Scholar Google (www.scholar.google.com.br), in which studies published from 1971 to 2021 were collected. Laboratory studies, case reports, systematic and literature reviews, which were developed in living individuals. Articles that did not deal with metal alloys and its use in dentistry were excluded. Through the review, it was possible to ver ify that all works presented the metal alloys and their main properties, indicating that they are divided into three main types: hi gh noble alloys, noble alloys and base metal alloys differing in their levels of constituent noble metals. Several alloys and meta ls are available for the dental market each presenting advantages and disadvantages, mainly based on its specific composition.Continuous research and development are resulting in the production of new technologies and products, giving dental surgeons even more options in the design and manufacture of restorations using metal alloys and understanding that these resources will still be viable alternatives in oral rehabilitations. However, further studies on metal alloys are needed to better understand this subject.


RESUMEN: El presente trabajo tuvo como objetivo describir a través de una revisión de la literatura, los principales tipos de aleaciones nobles y no nobles utilizados en odontología buscando identificar los mecanismos de adhesión, composiciones y propiedades mecánicas, así como reflejar su aplicabilidad como recurso rehabilitador en la actualidad. Realizamos una búsqueda bibliográfica em las principales bases de datos de salud PUBMED (www.pubmed.gov) y Scholar Google (www.scholar.google.com.br), en la que se recopilaron estudios publicados desde 1971 hasta 2021. Estudios de laboratorio, informes de casos, revisiones sistemáticas y bibliográficas, que se desarrollaron en individuos vivos. Sin embargo, se excluyeron los artículos que no trataban sobre aleaciones metálicas y su uso en odontología. Se pudo observar que todos los trabajos presentaban las aleaciones metálicas y sus principales propiedades indicando que se estas dividen en tres tipos principales: aleaciones altamente nobles, aleaciones nobles y aleaciones de metales base que difierenen sus niveles de metales nobles constituyentes. Hay varias aleaciones y metales disponibles para el mercado dental, cada uno presenta ventajas y desventajas, principalmente en función de su composición específica. La investigación y el desarrollo continuo están dando como resultado la producción de nuevas tecnologías y productos, brindando a los cirujanos dentistas aún más opciones en el diseño y fabricación de las restauraciones, utilizando aleaciones metálicas y, permite concluir que estos recursos seguirán siendo alternativas viables en los tratamientos de rehabilitación. Sin embargo, se necesitan más estudios sobre el tema abordado en el trabajo, para una comprensión más profunda del tema.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...