Filtrar
1.
Am J Physiol Heart Circ Physiol ; 293(3): H1334-43, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17616750

RESUMO

The vitamin D(3) and nicotine (VDN) model is a model of isolated systolic hypertension (ISH) due to arterial calcification raising arterial stiffness and vascular impedance similar to an aged and stiffened arterial tree. We therefore analyzed the impact of this aging model on normal and diseased hearts with myocardial infarction (MI). Wistar rats were treated with VDN (n = 9), subjected to MI by coronary ligation (n = 10), or subjected to a combination of both MI and VDN treatment (VDN/MI, n = 14). A sham-treated group served as control (Ctrl, n = 10). Transthoracic echocardiography was performed every 2 wk, whereas invasive indexes were obtained at week 8 before death. Calcium, collagen, and protein contents were measured in the heart and the aorta. Systolic blood pressure, pulse pressure, thoracic aortic calcium, and end-systolic elastance as an index of myocardial contractility were highest in the aging model group compared with MI and Ctrl groups (P(VDN) < 0.05, 2-way ANOVA). Left ventricular wall stress and brain natriuretic peptide (P(VDNxMI) = not significant) were highest, while ejection fraction, stroke volume, and cardiac output were lowest in the combined group versus all other groups (P(VDNxMI) < 0.05). The combination of ISH due to this aging model and MI demonstrates significant alterations in cardiac function. This model mimics several clinical phenomena of cardiovascular aging and may thus serve to further study novel therapies.


Assuntos
Envelhecimento/fisiologia , Cardiomiopatias/fisiopatologia , Sistema Cardiovascular/fisiopatologia , Modelos Animais de Doenças , Animais , Cardiomiopatias/induzido quimicamente , Colecalciferol , Hipertensão/induzido quimicamente , Hipertensão/fisiopatologia , Masculino , Contração Miocárdica/fisiologia , Infarto do Miocárdio/induzido quimicamente , Infarto do Miocárdio/fisiopatologia , Nicotina , Ratos , Ratos Wistar , Volume Sistólico/fisiologia , Disfunção Ventricular Esquerda/induzido quimicamente , Disfunção Ventricular Esquerda/fisiopatologia
2.
Artif Organs ; 31(4): 290-300, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17437498

RESUMO

Recently, a new oxygenator (Dideco 903 [D903], Dideco, Mirandola, Italy) has been introduced to the perfusion community, and we set about testing its oxygen transfer performance and then comparing it to two other models. This evaluation was based on the comparison between oxygen transfer slope, gas phase arterial oxygen gradients, degree of blood shunting, maximum oxygen transfer, and diffusing capacity calculated for each membrane. Sixty patients were randomized into three groups of oxygenators (Dideco 703 [D703], Dideco; D903; and Quadrox, Jostra Medizintechnik AG, Hirrlingen, Germany) including 40/20 M/F of 68.6 +/- 11.3 years old, with a body weight of 71.5 +/- 12.1 kg, a body surface area (BSA) of 1.84 +/- 0.3 m(2), and a theoretical blood flow rate (index 2.4 times BSA) of 4.4 +/- 0.7 L/min. The maximum oxygen transfer (VO(2)) values were 313 mL O(2)/min (D703), 579 mL O(2)/min (D903), and 400 mL O(2)/min (Quadrox), with the D903 being the most superior (P < 0.05). Oxygen (O(2)) gradients were 320 mm Hg (D703), 235 mm Hg (D903), and 247 mm Hg (Quadrox), meaning D903 and Quadrox are more efficient versus the D703 (P < 0.05). Shunt fraction (Qs/Qt) and diffusing capacity (DmO(2)) were comparable (P = ns). Diffusing capacity values indexed to BSA (DmO(2)/m(2)) were 0.15 mL O(2)/min/mm Hg/m(2) (D703), 0.2 mL O(2)/min/mm Hg/m(2) (D903), and 0.18 mL O(2)/min/mm Hg/m(2) (Quadrox) with D903 outperforming D703 (P < 0.0005). During hypothermia (32.0 +/- 0.3 degrees C), there was a lower absolute and relative VO(2 )for all three oxygenators (P = ns). The O(2) gradients, DmO(2) and DmO(2)/m(2), were significantly lower for all oxygenators (P < 0.01). Also, Qs/Qt significantly rose for all oxygenators (P < 0.01). The oxygen transfer curve is characteristic to each oxygenator type and represents a tool to quantify oxygenator performance. Using this parameter, we demonstrated significant differences among commercially available oxygenators. However, all three oxygenators are considered to meet the oxygen needs of the patients.


Assuntos
Ponte Cardiopulmonar/instrumentação , Ponte de Artéria Coronária/instrumentação , Oxigenação por Membrana Extracorpórea/instrumentação , Hipotermia Induzida , Oxigênio/metabolismo , Oxigenadores de Membrana , Idoso , Ponte Cardiopulmonar/métodos , Ponte de Artéria Coronária/métodos , Oxigenação por Membrana Extracorpórea/métodos , Feminino , Humanos , Masculino , Consumo de Oxigênio , Temperatura
3.
Artif Organs ; 31(1): 23-30, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17209957

RESUMO

Since the inception of cardiopulmonary bypass (CPB), little progress has been made concerning the design of cardiotomy suction (CS). Because this is a major source of hemolysis, we decided to test a novel device (Smartsuction [SS]) specifically aimed at minimizing hemolysis during CPB in a clinical setting. Block randomization was carried out on a treated group (SS, n=28) and a control group (CTRL, n=26). Biochemical parameters were taken pre-, peri-, and post CPB and were compared between the two groups using the Student's t-test with statistical significance when P<0.05. No significant differences in patient demographics were observed between the two groups. Lactate dehydrogenase (LDH) and plasma free hemoglobin (PFH) pre-CPB were comparable for the CTRL and SS groups, respectively. LDH peri-CPB was 275+/-100 U/L versus 207+/-83 U/L for the CTRL and SS groups, respectively (P<0.05). PFH was 486+/-204 mg/L versus 351+/-176 mg/L for the CTRL and SS groups, respectively (P<0.05). LDH post CPB was 354+/-116 U/L versus 275+/-89 U/L for the CTRL and SS groups, respectively (P<0.05). PFH was 549+/-271 mg/L versus 460+/-254 mg/L for the CTRL and SS groups, respectively (P<0.05). Preoperative hematocrit (Hct) of 43+/-5% (CTRL) versus 37+/-5% (SS), and hemoglobin (Hb) of 141+/-16 g/L (CTRL) versus 122+/-17 g/L (SS) were significantly lower in the SS group. However, when normalized (N), the SS was capable of conserving Hct, Hb, and erythrocyte count perioperatively. Erythrocytes (N) were 59+/-5% (CTRL) versus 67+/-9% (SS); Hct (N) was 59+/-6% (CTRL) versus 68+/-9% (SS), and Hb (N) was 61+/-6% (CTRL) versus 70+/-10% (SS) (all P<0.05). This novel SS device evokes significantly lowered blood PFH and LDH values peri- and post CPB compared with the CTRL blood using a CS system. The SS may be a valuable alternative compared to traditional CS techniques.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ponte Cardiopulmonar/efeitos adversos , Ponte Cardiopulmonar/instrumentação , Máquina Coração-Pulmão/efeitos adversos , Hemólise , Complicações Pós-Operatórias/prevenção & controle , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Procedimentos Cirúrgicos Cardíacos/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sucção/efeitos adversos , Sucção/instrumentação , Sucção/métodos
4.
J Appl Physiol (1985) ; 102(3): 1123-9, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17158245

RESUMO

It has been suggested that the shape of the normalized time-varying elastance curve [E(n)(t(n))] is conserved in different cardiac pathologies. We hypothesize, however, that the E(n)(t(n)) differs quantitatively after myocardial infarction (MI). Sprague-Dawley rats (n = 9) were anesthetized, and the left anterior descending coronary artery was ligated to provoke the MI. A sham-operated control group (CTRL) (n = 10) was treated without the MI. Two months later, a conductance catheter was inserted into the left ventricle (LV). The LV pressure and volume were measured and the E(n)(t(n)) derived. Slopes of E(n)(t(n)) during the preejection period (alpha(PEP)), ejection period (alpha(EP)), and their ratio (beta = alpha(EP)/alpha(PEP)) were calculated, together with the characteristic decay time during isovolumic relaxation (tau) and the normalized elastance at end diastole (E(min)(n)). MI provoked significant LV chamber dilatation, thus a loss in cardiac output (-33%), ejection fraction (-40%), and stroke volume (-30%) (P < 0.05). Also, it caused significant calcium increase (17-fold), fibrosis (2-fold), and LV hypertrophy. End-systolic elastance dropped from 0.66 +/- 0.31 mmHg/microl (CTRL) to 0.34 +/- 0.11 mmHg/microl (MI) (P < 0.05). Normalized elastance was significantly reduced in the MI group during the preejection, ejection, and diastolic periods (P < 0.05). The slope of E(n)(t(n)) during the alpha(PEP) and beta were significantly altered after MI (P < 0.05). Furthermore, tau and end-diastolic E(min)(n) were both significantly augmented in the MI group. We conclude that the E(n)(t(n)) differs quantitatively in all phases of the heart cycle, between normal and hearts post-MI. This should be considered when utilizing the single-beat concept.


Assuntos
Infarto do Miocárdio/fisiopatologia , Função Ventricular Esquerda/fisiologia , Animais , Pressão Sanguínea/fisiologia , Volume Cardíaco/fisiologia , Elasticidade , Masculino , Infarto do Miocárdio/patologia , Miocárdio/patologia , Ratos , Ratos Sprague-Dawley , Fatores de Tempo
5.
Perfusion ; 22(5): 311-6, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18416215

RESUMO

BACKGROUND: To date, there is no quality assurance program that correlates patient outcome to perfusion service provided during cardiopulmonary bypass (CPB). A score was devised, incorporating objective parameters that would reflect the likelihood to influence patient outcome. The purpose was to create a new method for evaluating the quality of care the perfusionist provides during CPB procedures and to deduce whether it predicts patient morbidity and mortality. METHODS: We analysed 295 consecutive elective patients. We chose 10 parameters: fluid balance, blood transfused, Hct, ACT, PaO2, PaCO2, pH, BE, potassium and CPB time. Distribution analysis was performed using the Shapiro-Wilcoxon test. This made up the PerfSCORE and we tried to find a correlation to mortality rate, patient stay in the ICU and length of mechanical ventilation. Univariate analysis (UA) using linear regression was established for each parameter. Statistical significance was established when p < 0.05. Multivariate analysis (MA) was performed with the same parameters. RESULTS: The mean age was 63.8 +/- 12.6 years with 70% males. There were 180 CABG, 88 valves, and 27 combined CABG/valve procedures. The PerfSCORE of 6.6 +/- 2.4 (0-20), mortality of 2.7% (8/295), CPB time 100 +/- 41 min (19-313), ICU stay 52 +/- 62 hrs (7-564) and mechanical ventilation of 10.5 +/- 14.8 hrs (0-564) was calculated. CPB time, fluid balance, PaO2, PerfSCORE and blood transfused were significantly correlated to mortality (UA, p < 0.05). Also, CPB time, blood transfused and PaO2 were parameters predicting mortality (MA, p < 0.01). Only pH was significantly correlated for predicting ICU stay (UA). Ultrafiltration (UF) and CPB time were significantly correlated (UA, p < 0.01) while UF (p < 0.05) was the only parameter predicting mechanical ventilation duration (MA). CONCLUSIONS: CPB time, blood transfused and PaO2 are independent risk factors of mortality. Fluid balance, blood transfusion, PaO2, PerfSCORE and CPB time are independent parameters for predicting morbidity. PerfSCORE is a quality of perfusion measure that objectively quantifies perfusion performance.


Assuntos
Ponte Cardiopulmonar/mortalidade , Ponte Cardiopulmonar/normas , Assistência Perioperatória/estatística & dados numéricos , Indicadores de Qualidade em Assistência à Saúde , Índice de Gravidade de Doença , Idoso , Transfusão de Sangue/mortalidade , Transfusão de Sangue/estatística & dados numéricos , Feminino , Humanos , Unidades de Terapia Intensiva/estatística & dados numéricos , Tempo de Internação/estatística & dados numéricos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Morbidade , Oxigênio/sangue , Estudos Prospectivos , Respiração Artificial/estatística & dados numéricos , Estudos Retrospectivos , Fatores de Risco
6.
Am J Physiol Heart Circ Physiol ; 291(4): H1942-51, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16699077

RESUMO

The vitamin D(3) and nicotine (VDN) model is one of isolated systolic hypertension (ISH) in which arterial calcification raises arterial stiffness and vascular impedance. The effects of VDN treatment on arterial and cardiac hemodynamics have been investigated; however, a complete analysis of ventricular-arterial interaction is lacking. Wistar rats were treated with VDN (VDN group, n = 9), and a control group (n = 10) was included without the VDN. At week 8, invasive indexes of cardiac function were obtained using a conductance catheter. Simultaneously, aortic pressure and flow were measured to derive vascular impedance and characterize ventricular-vascular interaction. VDN caused significant increases in systolic (138 +/- 6 vs. 116 +/- 13 mmHg, P < 0.01) and pulse (42 +/- 10 vs. 26 +/- 4 mmHg, P < 0.01) pressures with respect to control. Total arterial compliance decreased (0.12 +/- 0.08 vs. 0.21 +/- 0.04 ml/mmHg in control, P < 0.05), and pulse wave velocity increased significantly (8.8 +/- 2.5 vs. 5.1 +/- 2.0 m/s in control, P < 0.05). The arterial elastance and end-systolic elastance rose significantly in the VDN group (P < 0.05). Wave reflection was augmented in the VDN group, as reflected by the increase in the wave reflection coefficient (0.63 +/- 0.06 vs. 0.52 +/- 0.05 in control, P < 0.05) and the amplitude of the reflected pressure wave (13.3 +/- 3.1 vs. 8.4 +/- 1.0 mmHg in control, P < 0.05). We studied ventricular-arterial coupling in a VDN-induced rat model of reduced arterial compliance. The VDN treatment led to development of ISH and provoked alterations in cardiac function, arterial impedance, arterial function, and ventricular-arterial interaction, which in many aspects are similar to effects of an aged and stiffened arterial tree.


Assuntos
Volume Cardíaco/efeitos dos fármacos , Colecalciferol/farmacologia , Vasos Coronários/fisiologia , Estimulantes Ganglionares/farmacologia , Hipertensão/fisiopatologia , Nicotina/farmacologia , Função Ventricular , Animais , Volume Cardíaco/fisiologia , Complacência (Medida de Distensibilidade) , Vasos Coronários/efeitos dos fármacos , Relação Dose-Resposta a Droga , Elasticidade/efeitos dos fármacos , Ventrículos do Coração/efeitos dos fármacos , Hemodinâmica/efeitos dos fármacos , Hemodinâmica/fisiologia , Masculino , Modelos Cardiovasculares , Ratos , Ratos Wistar , Resistência Vascular/efeitos dos fármacos , Resistência Vascular/fisiologia
7.
Anesthesiology ; 104(5): 1004-14, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16645453

RESUMO

BACKGROUND: Postinfarct remodeled myocardium exhibits numerous structural and biochemical alterations. So far, it is unknown whether postconditioning elicited by volatile anesthetics can also provide protection in the remodeled myocardium. METHODS: Myocardial infarct was induced in male Wistar rats by ligation of the left anterior descending coronary artery. Six weeks later, hearts were buffer-perfused and exposed to 40 min of ischemia followed by 90 min of reperfusion. Anesthetic postconditioning was induced by 15 min of 2.1 vol% isoflurane. In some experiments, LY294002 (15 microM), a phosphatidylinositol 3-kinase inhibitor, was coadministered with isoflurane. Masson's trichrome staining, immunohistochemistry, Western blot analysis, and reverse-transcription polymerase chain reaction served to confirm remodeling. In buffer-perfused hearts, functional recovery was recorded, and acute infarct size was measured using 1% triphenyltetrazolium chloride staining and lactate dehydrogenase release during reperfusion. Western blot analysis was used to determine phosphorylation of reperfusion injury salvage kinases including protein kinase B/Akt and its downstream targets after 15 min of reperfusion. RESULTS: Infarct hearts exhibited typical macroscopic and molecular changes of remodeling. Isoflurane postconditioning improved functional recovery and decreased acute infarct size, as determined by triphenyltetrazolium (35 +/- 5% in unprotected hearts vs. 8 +/- 3% in anesthetic postconditioning; P < 0.05) and lactate dehydrogenase release. This protection was abolished by LY294002, which inhibited phosphorylation of protein kinase B/Akt and its downstream targets glycogen synthase kinase 3beta, endothelial nitric oxide synthase, and p70S6 kinase. CONCLUSIONS: Infarct-remodeled myocardium is receptive to protection by isoflurane postconditioning via protein kinase B/Akt signaling. This is the first time to demonstrate that anesthetic postconditioning retains its marked protection in diseased myocardium.


Assuntos
Anestésicos Inalatórios/farmacologia , Cardiotônicos , Isoflurano/farmacologia , Proteína Oncogênica v-akt/fisiologia , Proteínas Proto-Oncogênicas c-akt/fisiologia , Transdução de Sinais/efeitos dos fármacos , Remodelação Ventricular/efeitos dos fármacos , Animais , Western Blotting , Hemodinâmica/efeitos dos fármacos , Técnicas In Vitro , Masculino , Miocárdio/ultraestrutura , RNA Mensageiro/biossíntese , RNA Mensageiro/isolamento & purificação , Ratos , Ratos Wistar , Reação em Cadeia da Polimerase Via Transcriptase Reversa
8.
Eur J Cardiothorac Surg ; 29(4): 525-9, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16476552

RESUMO

OBJECTIVE: Transthoracic echocardiography (TTE) has been used clinically to disobstruct venous drainage cannula and to optimise placement of venous cannulae in the vena cava but it has never been used to evaluate performance capabilities. Also, little progress has been made in venous cannula design in order to optimise venous return to the heart lung machine. We designed a self-expandable Smartcanula (SC) and analysed its performance capability using echocardiography. METHODS: An epicardial echocardiography probe was placed over the SC or control cannula (CTRL) and a Doppler image was obtained. Mean (V(m)) and maximum (V(max)) velocities, flow and diameter were obtained. Also, pressure drop (DeltaP(CPB)) was obtained between the central venous pressure and inlet to venous reservoir. LDH and Free Hb were also compared in 30 patients. Comparison was made between the two groups using the student's t-test with statistical significance established when p<0.05. RESULTS: Age for the SC and CC groups were 61.6+/-17.6 years and 64.6+/-13.1 years, respectively. Weight was 70.3+/-11.6 kg and 72.8+/-14.4 kg, respectively. BSA was 1.80+/-0.2 m(2) and 1.82+/-0.2 m(2), respectively. CPB times were 114+/-53 min and 108+/-44 min, respectively. Cross-clamp time was 59+/-15 min and 76+/-29 min, respectively (p=NS). Free-Hb was 568+/-142 U/l versus 549+/-271 U/l post-CPB for the SC and CC, respectively (p=NS). LDH was 335+/-73 mg/l versus 354+/-116 mg/l for the SC and CC, respectively (p=NS). V(m) was 89+/-10 cm/s (SC) versus 63+/-3 cm/s (CC), V(max) was 139+/-23 cm/s (SC) versus 93+/-11 cm/s (CC) (both p<0.01). DeltaP(CPB) was 30+/-10 mmHg (SC) versus 43+/-13 mmHg (CC) (p<0.05). A Bland-Altman test showed good agreement between the two devices used concerning flow rate calculations between CPB and TTE (bias 300 ml+/-700 ml standard deviation). CONCLUSIONS: This novel Smartcanula design, due to its self-expanding principle, provides superior flow characteristics compared to classic two stage venous cannula used for adult CPB surgery. No detrimental effects were observed concerning blood damage. Echocardiography was effective in analysing venous cannula performance and velocity patterns.


Assuntos
Ponte Cardiopulmonar , Cateterismo Venoso Central/métodos , Ponte de Artéria Coronária , Cuidados Intraoperatórios/métodos , Adulto , Idoso , Antropometria , Cateterismo Venoso Central/instrumentação , Ecocardiografia Doppler/métodos , Desenho de Equipamento , Feminino , Hemoglobinas/metabolismo , Humanos , Lactato Desidrogenases/sangue , Masculino , Pessoa de Meia-Idade , Veia Cava Inferior/diagnóstico por imagem
9.
Am J Physiol Heart Circ Physiol ; 290(4): H1540-8, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16299257

RESUMO

The rodent model of myocardial infarction (MI) is extensively used in heart failure studies. However, long-term follow-up of echocardiographic left ventricular (LV) function parameters such as the myocardial performance index (MPI) and its ratio with the fractional shortening (LVFS/MPI) has not been validated in conjunction with invasive indexes, such as those derived from the conductance catheter (CC). Sprague-Dawley rats with left anterior descending coronary artery ligation (MI group, n = 9) were compared with a sham-operated control group (n = 10) without MI. Transthoracic echocardiography (TTE) was performed every 2 wk over an 8-wk period, after which classic TTE parameters, especially MPI and LVFS/MPI, were compared with invasive indexes obtained by using a CC. Serial TTE data showed significant alterations in the majority of the noninvasive functional and structural parameters (classic and novel) studied in the presence of MI. Both MPI and LVFS/MPI significantly (P < 0.05 for all reported values) correlated with body weight (r = -0.58 and 0.76 for MPI and LVFS/MPI, respectively), preload recruitable stroke work (r = -0.61 and 0.63), LV end-diastolic pressure (LVEDP) (r = 0.82 and -0.80), end-diastolic volume (r = 0.61 and -0.58), and end-systolic volume (r = 0.46 and -0.48). Forward stepwise linear regression analysis revealed that, of all variables tested, LVEDP was the only independent determinant of MPI (r = 0.84) and LVFS/MPI (r = 0.83). We conclude that MPI and LVFS/MPI correlate strongly and better than the classic noninvasive TTE parameters with established, invasively assessed indexes of contractility, preload, and volumetry. These findings support the use of these two new noninvasive indexes for long-term analysis of the post-MI LV remodeling.


Assuntos
Ecocardiografia Doppler em Cores/métodos , Testes de Função Cardíaca/métodos , Interpretação de Imagem Assistida por Computador/métodos , Infarto do Miocárdio/diagnóstico por imagem , Índice de Gravidade de Doença , Disfunção Ventricular Esquerda/diagnóstico por imagem , Animais , Cateterismo Cardíaco , Modelos Animais de Doenças , Masculino , Infarto do Miocárdio/complicações , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto , Disfunção Ventricular Esquerda/etiologia
10.
Interact Cardiovasc Thorac Surg ; 5(5): 540-3, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17670641

RESUMO

OBJECTIVES: To assess the performance of 45F vs. 36F smartcanula in CPB with gravity drainage alone. METHODS: Twenty patients were randomly assigned to two groups receiving for venous drainage a smartcanula which is collapsed over a mandrel for trans-atrial insertion into the inferior vena cava and expanded in situ to either 45F or 36F. RESULTS: Valve replacement/repair was realized in 7/10 and/or CABG in 6/10 for 36F (69+/-13 years) vs. 5/10 and 5/10, respectively, for 45F (63+/-11 years: NS). Body weight and surface area (BSA) were 83+/-9 kg (1.9+/-0.2 m2, max 2.2 m2) for 36F vs. 79+/-6 kg: NS (1.9+/-0.1 m2 (NS), max 2.1 m2) for 45F. Insertion and access orifice diameter (area) was 6 mm and 10 mm (78.5 mm2) for the 36F vs. 6 mm and 13 mm (132 mm2) for the 45F (+69%). Calculated target pump flow (2.4 l/min/m2) was 4.7+/-0.4 l/min for 36F vs. 4.5+/-0.3 l/min for 45F. Achieved pump flow accounted for 5.0+/-0.3 l/min for 36F (8% above target) vs. 4.8+/-0.3 l/min for 45F (8% above target): NS. The water balance during the pump run (clear volume added minus hemofilter and urine output) was 2.2+/-0.3 l for 36F vs. 2.0 l for 45F: NS. CONCLUSION: Due to its 'open' wall (the vena cava provides the seal), its reduced wall thickness (range: 0.0-0.4 mm), and its self-expanding design, the 36F smartcanula requiring a 30F access orifice has sufficient drainage capacity by gravity alone for full CPB in adults with a BSA up to 2.2 mm2.

11.
Heart Surg Forum ; 8(4): E241-5, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16112936

RESUMO

Devices for venous cannulation have seen significant progress over time: the original, rigid steel cannulas have evolved toward flexible plastic cannulas with wire support that prevents kinking, very thin walled wire wound cannulas allowing for percutaneous application, and all sorts of combinations. In contrast to all these rectilinear venous cannula designs, which present the same cross-sectional area over their entire intravascular path, the smartcanula concept of "collapsed insertion and expansion in situ" is the logical next step for venous access. Automatically adjusting cross-sectional area up to a pre-determined diameter or the vessel lumen provides optimal flow and ease of use for both, insertion and removal. Smartcanula performance was assessed in a small series of patients (76 +/- 17 kg) undergoing redo procedures. The calculated target pump flow (2.4 L/min/m2) was 4.42 +/- 61 L/ min. Mean pump flow achieved during cardiopulmonary bypass was 4.84 +/- 87 L/min or 110% of the target. Reduced atrial chatter, kink resistance in situ, and improved blood drainage despite smaller access orifice size, are the most striking advantages of this new device. The benefits of smart cannulation are obvious in remote cannulation for limited access cardiac surgery, but there are many other cannula applications where space is an issue, and that is where smart cannulation is most effective.


Assuntos
Procedimentos Cirúrgicos Cardíacos/instrumentação , Cateterismo/instrumentação , Procedimentos Cirúrgicos Cardíacos/métodos , Ponte Cardiopulmonar/instrumentação , Ponte Cardiopulmonar/métodos , Cateterismo/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Perfusão/instrumentação , Perfusão/métodos
12.
Artif Organs ; 28(7): 649-54, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15209858

RESUMO

Since the initiation of cardiac surgery using cardiopulmonary bypass, little progress has been made concerning the design of catheters for vascular access. However, in the last few years, research in this specialized field has established that catheter performance not only depends on size but also on the catheter's design. The catheter's drainage hole surface area correlates with its performance, i.e., flow; the ratio of the catheter's diameter to the patient's vein diameter also correlates with flow. These findings should influence the design of future models. An example is presented with the development of the Smartcanula which maximizes hole surface area and minimizes the wall thickness in order to optimize flow rate and vascular access to the patient.


Assuntos
Ponte Cardiopulmonar , Cateteres de Demora , Cateterismo Periférico , Humanos
13.
J Extra Corpor Technol ; 35(3): 207-11, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-14653422

RESUMO

Vacuum-assist venous drainage (VAVD) can increase venous blood return during cardiopulmonary bypass (CPB) procedures. However, the negative pressure created in the closed cardiotomy reservoir can be transmitted to the oxygenator if a nonocclusive or centrifugal arterial pump is used, resulting in bubble transgression (BT) from the gas to blood compartment of the oxygenator. We analyzed the vacuum pressure required to produce BT using an in vitro circuit including successively a closed reservoir, a pump (centrifugal or roller), and an oxygenator. A constant hydrostatic pressure was maintained onto the oxygenator. Vacuum was applied on the cardiotomy reservoir, progressively increasing negative pressure from 0 to -80 mmHg and monitoring BT with a bubble detector. Six different oxygenators were compared. A partially occlusive roller pump and a centrifugal pump were compared to a control, which was without any pump. A mean negative pressure of -53 +/- 7 mmHg was necessary to produce BT in all the oxygenators in the absence of a pump. The presence of a centrifugal pump between the reservoir and the oxygenator significantly increased the negative pressure required to produce BT compared to the control (-67 +/- 7 mmHg, p < .05). No bubbles were detected using the roller pump (> -80 mmHg needed for BT), thus statistically significant when compared to the centrifugal pump (p < .05). The centrifugal pump offers significant resistance to BT but not as much compared to the roller pump, though BT cannot be prevented if the pump is turned off while the vacuum remains on the reservoir. Therefore, VAVD is a safe technique as long as the perfusionist stops the vacuum when the arterial pump is no longer in use.


Assuntos
Ponte Cardiopulmonar/instrumentação , Oxigenação por Membrana Extracorpórea/instrumentação , Oxigenadores , Sucção/instrumentação , Adulto , Ponte Cardiopulmonar/métodos , Humanos , Técnicas In Vitro , Oxigenadores/normas , Suíça
14.
Perfusion ; 18(4): 219-24, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-14575410

RESUMO

Cardiopulmonary bypass (CPB) remains the key technology for more complex cardiac operations. The perfusion equipment used nowadays has seen tremendous progress since its introduction into clinical practice 50 years ago. However, overall, CPB is still far from perfect. Major haemodilution is not only a problem for red cell-dependent gas transport, but also for the platelet and humeral factor-dependent coagulation, the protein-dependent intravascular oncotic pressure and so forth. Reduction of the priming volume through further miniaturization of CPB equipment is, therefore, the most obvious next step. A systematic approach needs to optimize all CPB components, including pumps, oxygenator/heat exchanger structures, filters, reservoirs, cardiotomy suction, tubings and cannulas. This report provides an update of already commercially available low prime perfusion devices (e.g., the CORx integrated pump-oxygenator) as well as promising prototypes like the smart suction system and the smartcanula.


Assuntos
Ponte Cardiopulmonar/instrumentação , Miniaturização , Cateterismo , Desenho de Equipamento , Humanos , Oxigenadores
15.
ASAIO J ; 49(4): 365-9, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12918575

RESUMO

To limit the morbidity of cardiopulmonary bypass (CPB), a new concept of integrating pumping, oxygenation, and air removal into a single unit has been developed (CardioVention Inc., Santa Clara, CA). The air filtration capacity of this system was tested. Three calves (73.2 +/- 2 kg) were connected to the integrated system by jugular and carotid cannulation. The integrated unit was challenged with injections of boluses of air of 5, 10, and 20 ml, three times each, and for a blood flow of 3 L/min and 5 L/min, respectively. The bubble count and size were recorded downstream of the unit with a Doppler ultrasound. At 3 L/min, bubbles were detected after injections of 20 ml only (n = 7 for the nine boluses). At 5 L/min, 1 bubble was detected with the nine injections of 5 ml, 14 bubbles were detected with nine injections of 10 ml, and 25 bubbles were detected with nine injections of 20 ml. No bubble exceeded 40 microm in diameter as determined by the Doppler ultrasound. The air filtering capacity of the CardioVention system is excellent both in terms of bubble count and of size after injection of large boluses of air. Its integrated concept offers a simplification of the circuit with fewer devices and connections, which further reduces the risk of accidental air introduction.


Assuntos
Ponte Cardiopulmonar/instrumentação , Ar , Animais , Ponte Cardiopulmonar/efeitos adversos , Bovinos , Desenho de Equipamento , Filtração/instrumentação , Humanos
16.
Perfusion ; 18(1): 61-5, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12705652

RESUMO

During cardiopulmonary bypass (CPB), venous drainage may be impeded due to small vessel and cannula size or chattering, thus, blood return to the heart-lung machine is reduced. We designed a self-expandable prototype cannula, which is able to maintain the vein open and overcome this problem and analysed its performance capability. This prototype and several other cannulae were tested using an access vessel diameter of 7 mm. An in vitro circuit was set up with a 10 mm penrose latex tube simulating the patient's vein placed between the patient preload reservoir and the cannula, encasing the cannula's inlet(s). Maximum flow rate was determined for passive venous drainage (PVD) at preloads (P) of 2 and 4 mmHg. We compared these results to three classic single-stage venous cannulae: basket tip, thoracic drain and percutaneous tip. By comparing the other cannulae to the prototype, under PVD conditions and a central venous pressure (CVP) of 2 mmHg, the prototype cannula's flow rate (1.32 +/- 0.04 L/min) outperformed the basket type (the best performing comparator) (1.02 +/- 0.08 L/min) by 23% (p < 0.005). When the preload was increased to 4 mmHg under PVD conditions, the same trend was noted with the prototype cannula (1.65 +/- 0.05 L/min), outperforming the basket cannula's value (1.26 +/- 0.05 L/min) by 24% (p < 0.001). This new cannula design provides superior flow characteristics, under all test conditions, compared to the classic single-stage venous cannulae used for paediatric CPB surgery.


Assuntos
Cateterismo Venoso Central/instrumentação , Velocidade do Fluxo Sanguíneo , Criança , Desenho de Equipamento , Análise de Falha de Equipamento , Hemorreologia , Humanos
17.
Ann Thorac Surg ; 74(4): S1330-3, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12400811

RESUMO

BACKGROUND: During percutaneous cannulation, the diameter of the venous cannula is determined by the size of the access site. To limit this restriction, the Smart cannula (Cardiosmart Ltd., Fribourg, Switzerland) has been developed. Because its design allows self-expansion within the recipient vein, diameter restriction is limited to the access site. METHODS: In 6 calves (78 +/- 4.3 kg), the jugular vein and the carotid artery were cannulated through a cervicotomy. The Smart cannula was tested against three percutaneous cannulas with a diameter of 27, 25, and 21F, respectively. Stenotic percutaneous access to the vein was simulated by 1-cm wide tape encircling the vein that could be adjusted to a diameter of 27, 25, and 21F, respectively. The maximal flow rate, reached with stable reservoir level and a negative pressure of 44 mm Hg, was determined three times for each access size with the Smart cannula (one size fits all) and the corresponding percutaneous cannula successively. RESULTS: For an access size of 27F, the flow of the Smart cannula was 5.7 +/- 0.4 L/min and that of the percutaneous cannula was 4.3 +/- 0.2 L/min (p < 0.0001); for 25F, flow rates were 5.6 +/- 0.5 and 3.9 +/- 0.2 L/min, respectively (p < 0.0001); and for 21F, the flow rates were 4.3 +/- 0.4 and 2.7 +/- 0.3 L/min, respectively (p < 0.0001). The percentage increase of flow for the 27, 25, and 21F sizes were 34% +/- 9%, 42% +/- 16%, and 53% +/- 18%, respectively (one-way analysis of variance, p = 0.014). CONCLUSIONS: For the present set-up, the Smart cannula outperforms commercially available percutaneous cannulas. The smaller the size of the insertion site, we observed a higher gain of flow with the Smart cannula.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cateterismo/instrumentação , Toracoscopia , Animais , Artérias Carótidas , Bovinos , Desenho de Equipamento , Veias Jugulares
18.
ASAIO J ; 48(5): 483-6, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12296567

RESUMO

Trillium coating (Medtronic Inc., Minneapolis, MN) offers, in addition to the presence of heparin, endothelium-like properties of its negatively charged surface. Its thromboresistant properties on coated connectors are tested here and compared with uncoated standard connectors, as well as with the Carmeda BioActive surface (CBAS) heparin surface coating. A partial cardiopulmonary bypass bovine model (body weight 68 +/- 5 kg) was selected, and the surfaces were exposed to the blood stream (pump flow 3.5 L/min) for up to 350 minutes without systemic heparinization. Thereafter, another set of samples was exposed to stagnant blood for 20 minutes. Besides hemodynamic, hematologic, and biochemical analyses, the macroscopic appearance of 45 blood exposed surface samples were graded semiquantitatively on a scale of 0 to 10: no macroscopic deposits = grade 0, one spot (1 mm diameter) = grade 1, two spots = grade 2, five or more spots = grade 5, 10% of the surface covered with clots = grade 6, 100% covered = grade 10. When exposed to blood flow, Trillium and CBAS coatings showed a statistically significant (p = 0.03) better thromboresistance (score: 0 +/- 0 for both) than uncoated connectors (score: 0.8 +/- 1.5) in this nonheparinized model. The same holds true when the connectors were exposed to stagnant blood (score: 0 +/- 0 for both coatings vs 4.3 +/- 2.8 for controls; p = 0.03). Therefore, Trillium coating exhibits significant antithrombotic properties that outperform standards for connectors used in clinical perfusion.


Assuntos
Ponte Cardiopulmonar/métodos , Materiais Revestidos Biocompatíveis/farmacologia , Trombose/prevenção & controle , Animais , Anticoagulantes/farmacologia , Pressão Sanguínea , Ponte Cardiopulmonar/instrumentação , Bovinos , Hemoglobinas , Heparina/farmacologia , Oxigênio/sangue , Tempo de Coagulação do Sangue Total
19.
Eur J Cardiothorac Surg ; 21(5): 840-6, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-12062272

RESUMO

OBJECTIVE: Standard cardiopulmonary bypass (CPB) circuits with their large surface area and volume contribute to postoperative systemic inflammatory reaction and hemodilution. In order to minimize these problems a new approach has been developed resulting in a single disposable, compact arterio-venous loop, which has integral kinetic-assist pumping, oxygenating, air removal, and gross filtration capabilities (CardioVention Inc., Santa Clara, CA, USA). The impact of this system on gas exchange capacity, blood elements and hemolysis is compared to that of a conventional circuit in a model of prolonged perfusion. METHODS: Twelve calves (mean body weight: 72.2+/-3.7 kg) were placed on cardiopulmonary bypass for 6 h with a flow of 5 l/min, and randomly assigned to the CardioVention system (n=6) or a standard CPB circuit (n=6). A standard battery of blood samples was taken before bypass and throughout bypass. Analysis of variance was used for comparison. RESULTS: The hematocrit remained stable throughout the experiment in the CardioVention group, whereas it dropped in the standard group in the early phase of perfusion. When normalized for prebypass values, both profiles differed significantly (P<0.01). Both O2 and CO2 transfers were significantly improved in the CardioVention group (P=0.04 and P<0.001, respectively). There was a slightly higher pressure drop in the CardioVention group but no single value exceeded 112 mmHg. No hemolysis could be detected in either group with all free plasma Hb values below 15 mg/l. Thrombocyte count, when corrected by hematocrit and normalized by prebypass values, exhibited an increased drop in the standard group (P=0.03). CONCLUSION: The CardioVention system with its concept of limited priming volume and exposed foreign surface area, improves gas exchange probably because of the absence of detectable hemodilution, and appears to limit the decrease in the thrombocyte count which may be ascribed to the reduced surface. Despite the volume and surface constraints, no hemolysis could be detected throughout the 6 h full-flow perfusion period.


Assuntos
Ponte Cardiopulmonar/instrumentação , Animais , Plaquetas/fisiologia , Ponte Cardiopulmonar/métodos , Bovinos , Modelos Animais , Oxigênio/fisiologia , Pressão , Troca Gasosa Pulmonar
20.
Rev Med Suisse Romande ; 122(3): 137-40, 2002 Mar.
Artigo em Francês | MEDLINE | ID: mdl-12014251

RESUMO

The mechanical cardiac assistance, once limited only to the adult patients, is now progressively extended to the paediatric population, including neonates. Currently for children with cardiorespiratory insufficiency requiring for a mechanical assistance there are available several options: Intra-Aortic Balloon Pump, Extra-Corporeal Membrane Oxygenation (ECMO) et le Ventricular Assist Device. From April 1999 in our Department of Cardiovascular Surgery at CHUV 8 children, including 4 neonates, have been treated with ECMO. Indications, contra-indications, advantages, disadvantages, results and complications of the available options of paediatric mechanical cardiac assistance are described.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Cardiopatias Congênitas/terapia , Insuficiência Cardíaca/terapia , Balão Intra-Aórtico/métodos , Criança , Pré-Escolar , Coração Auxiliar , Humanos , Lactente , Recém-Nascido