Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Shoulder Elbow Surg ; 33(4): 900-907, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37625693

RESUMO

BACKGROUND: Outpatient total shoulder arthroplasty (TSA) presents a safe alternative to inpatient arthroplasty, while helping meet the rapidly rising volume of shoulder arthroplasty needs and minimizing health care costs. Identifying the correct patient for outpatient surgery is critical to maintaining the safety standards with TSA. This study sought to update an ambulatory surgery center (ASC) TSA patient-selection algorithm previously published by our institution. METHODS: A retrospective chart review of TSAs was performed in an ASC at a single institution to collect patient demographics, perioperative risk factors, and postoperative outcomes with regard to reoperations, hospital admissions, and complications. The existing ASC algorithm for outpatient TSA was altered based on collected perioperative information, review of pertinent literature, and anesthesiology recommendations. RESULTS: A total of 319 TSAs were performed in an ASC in 298 patients over 7 years. Medically related complications occurred in 3 patients (0.9%) within 90 days of surgery, 2 of whom required hospital admission (0.6%) for acute kidney injury and pulmonary embolus. There were no instances of major cardiac events. Orthopedic-related complications occurred in 11 patients (3.4%), with hematoma development requiring evacuation and instability requiring revision being the most common causes. CONCLUSIONS: There was a low rate of perioperative complications and hospital admissions, confirming the safety of TSAs in an ASC setting. Based on prior literature and the population included, a pre-existing patient-selection algorithm was updated to better reflect increased comfort, knowledge, and data regarding safe patient selection for TSA in an ASC.


Assuntos
Artroplastia do Ombro , Humanos , Estudos Retrospectivos , Procedimentos Cirúrgicos Ambulatórios/efeitos adversos , Pacientes Ambulatoriais , Seleção de Pacientes , Algoritmos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
2.
Eur J Orthop Surg Traumatol ; 34(2): 893-900, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37770594

RESUMO

PURPOSE: The primary goal of this study was to investigate whether superior humeral head osteophyte (SHO) size is associated with rotator cuff insufficiency, including rotator cuff tear (RCT), supraspinatus tendon thickness, and fatty infiltration of the rotator cuff muscles. METHODS: Patients ≥ 18 years who were diagnosed with glenohumeral osteoarthritis were retrospectively reviewed. SHO size was determined by radiograph. MRI measured SHO and RCT presence, type, and size; supraspinatus tendon thickness; and fatty infiltration of rotator cuff musculature. RESULTS: A total of 461 patients were included. Mean SHO size was 1.93 mm on radiographs and 2.13 mm on MRI. Risk ratio for a RCT was 1.14. For each 1-mm increase in SHO size on radiograph, supraspinatus tendon thickness decreased by 0.20 mm. SHO presence was associated with moderate-to-severe fatty infiltration of the supraspinatus with a risk ratio of 3.16. CONCLUSION: SHOs were not associated with RCT but were associated with higher risk of supraspinatus FI and decreased tendon thickness, which could indicate rotator cuff insufficiency. LEVEL OF EVIDENCE: IV.


Assuntos
Osteoartrite , Osteófito , Lesões do Manguito Rotador , Articulação do Ombro , Humanos , Manguito Rotador/diagnóstico por imagem , Cabeça do Úmero/diagnóstico por imagem , Osteófito/complicações , Osteófito/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem , Lesões do Manguito Rotador/complicações , Lesões do Manguito Rotador/diagnóstico por imagem , Osteoartrite/complicações , Osteoartrite/diagnóstico por imagem
3.
Arthroplast Today ; 22: 101164, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37521741

RESUMO

Background: Cryoneurolysis utilizes temperatures below -20°C for nonpermanent analgesia to control pain in total knee arthroplasty (TKA). There is concern that body habitus could limit pain control because of accuracy of cryoneurolysis to subcutaneous nerves. This study aimed to determine the relationship between body habitus and effectiveness of cryoneurolysis on postoperative pain control. Methods: A retrospective chart review was performed on patients undergoing cryoneurolysis before primary TKA from 2017 to 2019. Included were 114 patients (58 control group and 56 treatment group). Cryoneurolysis patients were divided into 3 groups (small, medium, and large) based on the soft tissue to femoral diaphysis ratio of 7 cm proximal to superior pole of the patella. Postoperative outcome measures were morphine equivalents, numerical rating score for pain, range of motion, and Knee Injury and Osteoarthritis Outcome Score Joint Replacement. Results: The small cryoneurolysis group showed decreased opioid consumption at the 2, 6, and 12 weeks compared with control group, with morphine equivalents significantly decreased at 2 weeks for small compared with medium groups (54.3 vs 142.9, P = .0097). Numerical rating score for pain decreased significantly between small and medium groups (3.4 vs 4.0, P = .012) and between medium and large groups (4.0 vs 2.4, P = .012). Range of motion increased at 12 weeks for small group compared with medium group (118 vs 112, P = .042). There were no differences in any outcome measure between small and large groups. Conclusions: Body habitus does not appear to affect efficacy of cryoneurolysis in controlling postoperative pain following TKA. Cryoneurolysis remains a useful tool for multimodal pain management.

4.
Orthop Clin North Am ; 54(2): 209-225, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36894293

RESUMO

Shoulder arthroplasty is a rapidly improving and utilized management for end-stage arthritis that is associated with improved functional outcomes, pain relief, and long-term implant survival. Accurate placement of the glenoid and humeral components is critical for improved outcomes. Traditionally, preoperative planning was limited to radiographs and 2-dimensional computed tomography (CT); however, 3-dimensional CT is becoming more commonly utilized and necessary to understand complex glenoid and humeral deformities. To further increase accurate component placement, intraoperative assistive devices-patient-specific instrumentation, navigation, and mixed reality-minimize malpositioning, increase surgeon accuracy, and maximize fixation. These intraoperative technologies likely represent the future of shoulder arthroplasty.


Assuntos
Artroplastia do Ombro , Realidade Aumentada , Articulação do Ombro , Cirurgia Assistida por Computador , Humanos , Artroplastia do Ombro/métodos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Imageamento Tridimensional
5.
JBJS Case Connect ; 10(3): e20.00161, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32910611

RESUMO

CASE: A 58-year-old man sustained multiple right foot injuries during a motor vehicle accident that included a calcaneus fracture requiring open reduction and internal fixation (ORIF). The procedure was complicated by a prominent implant inferior to the sustentaculum, which necessitated a return to the operating room. Commonly used fluoroscopic views do not adequately image this area. A cadaveric study was undertaken to identify the optimal 2-dimensional fluoroscopic view that evaluates prominent implants at the medial calcaneus. CONCLUSION: The sustentaculum tunnel view gives a reliable image of prominent medial implants, and use of this technique may limit complications after calcaneus ORIF.


Assuntos
Calcâneo/diagnóstico por imagem , Traumatismos do Pé/diagnóstico por imagem , Fraturas Ósseas/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Acidentes de Trânsito , Calcâneo/lesões , Traumatismos do Pé/cirurgia , Fixação Interna de Fraturas , Fraturas Ósseas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade
6.
ACS Synth Biol ; 6(8): 1440-1444, 2017 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-28430408

RESUMO

If fieldable riboswitch-based biological sensors are to fulfill their potential, it is necessary to increase their signal output. Here we report a novel modular amplification system using a riboswitch to initiate signaling between a sensing strain and a reporter strain of E. coli. A quorum sensing signaling molecule biologically wires the sensing and reporter strains together. The amplification circuit increased the amount of fluorescence generated on ligand binding compared to when the riboswitch controlled fluorescence expression directly. This had the corollary effect of increasing the sensitivity of the system, and allowed riboswitch-based reporting in E. coli strains that did not produce a detectable output when the riboswitch directly controlled reporter expression. The amplification circuit also reduced the time required to detect a signal output. The modularity of this amplification system coupled with the achievable increases in output can advance the development of riboswitches and biological sensors.


Assuntos
Técnicas Biossensoriais/métodos , Escherichia coli/genética , Regulação Bacteriana da Expressão Gênica/genética , Genes Reporter/genética , Riboswitch/genética , Espectrometria de Fluorescência/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...