Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 103
Filtrar
2.
Eur J Med Chem ; 191: 112120, 2020 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-32120339

RESUMO

N-Methylpyrrolidone is one of several chemotypes that have been described as a mimetic of acetyl-lysine in the development of bromodomain inhibitors. In this paper, we describe the synthesis of a 4-phenyl substituted analogue - 1-methyl-4-phenylpyrrolidin-2-one - and the use of aryl substitution reactions as a divergent route for derivatives. Ultimately, this has led to structurally complex, chiral compounds with progressively improved affinity as inhibitors of bromodomain-containing protein 4.


Assuntos
Proteínas de Ciclo Celular/antagonistas & inibidores , Desenho de Fármacos , Pirrolidinonas/farmacologia , Fatores de Transcrição/antagonistas & inibidores , Proteínas de Ciclo Celular/metabolismo , Cristalografia por Raios X , Relação Dose-Resposta a Droga , Transferência Ressonante de Energia de Fluorescência , Humanos , Modelos Moleculares , Estrutura Molecular , Pirrolidinonas/química , Relação Estrutura-Atividade , Fatores de Transcrição/metabolismo
3.
Bioorg Med Chem ; 27(24): 115157, 2019 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-31727451

RESUMO

N-Methylpyrrolidone is a solvent molecule which has been shown to compete with acetyl-lysine-containing peptides for binding to bromodomains. From crystallographic studies, it has also been shown to closely mimic the acetamide binding motif in several bromodomains, but has not yet been directly pursued as a fragment in bromodomain inhibition. In this paper, we report the elaboration of N-methylpyrrolidone as a potential lead in fragment-based drug design. Firstly, N-methylpyrrolidone was functionalised to provide points for chemical elaboration. Then, the moiety was incorporated into analogues of the reported bromodomain inhibitor, Olinone. X-ray crystallography revealed that the modified analogues showed comparable binding affinity and structural mimicry to Olinone in the bromodomain binding site.


Assuntos
Proteínas de Ciclo Celular/química , Desenho de Fármacos , Pirrolidinonas/síntese química , Fatores de Transcrição/química , Sítios de Ligação , Proteínas de Ciclo Celular/metabolismo , Cristalografia por Raios X , Transferência Ressonante de Energia de Fluorescência , Regulação da Expressão Gênica/efeitos dos fármacos , Humanos , Modelos Moleculares , Estrutura Molecular , Ligação Proteica , Conformação Proteica , Pirrolidinonas/química , Relação Estrutura-Atividade , Fatores de Transcrição/metabolismo
4.
Int J Lab Hematol ; 39(6): 653-662, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28766854

RESUMO

INTRODUCTION: Mutations in fibrinogen (Fgn) genes, causing dysfibrinogenaemia, can result in either a bleeding or thrombophilic diathesis. Dysfibrinogenaemia is infrequently encountered in hospital laboratories, and the utility of different assays in the diagnosis of dysfibrinogenaemia has not previously been explored in a multicentre study. We describe here an exercise in which PRO-RBDD project (prospective data collection on patients with fibrinogen and Factor XIII deficiencies) centres, and UK NEQAS centres, performed investigations for dysfibrinogenaemia. METHODS: Samples from donors with dysfibrinogenaemia (sample 1: gamma p.Arg301Cys, sample 2: Bbeta166Arg3Cys-Fgn Longmont, sample 3: Aalpha p.Arg35His) and a normal donor were sent to laboratories for investigation for possible dysfibrinogenaemia. Median, coefficient of variation and range were determined for each assay method. RESULTS: Results were returned from 62 UK NEQAS and 24 PRO-RBDD centres. PT, APTT, Clauss fibrinogen and thrombin times were performed by >90% of centres, with 51% performing reptilase times, and 31% fibrinogen antigen. All centres identified samples 1 and 3 as abnormal. However, 39% of centres reported a normal or raised fibrinogen for the Fgn Longmont sample, and marked differences in Clauss fibrinogen results with different reagents were noted for this sample (median 1.01 g/L vs 5.10 g/L for the two mostly widely used reagents). CONCLUSION: In-house studies suggest that the method of detection of fibrin clot formation may result in different Clauss fibrinogen measurements with FgnLongmont plasma. It is possible that some widely used methodologies, both using optical and mechanical end-point detection systems, will fail to detect this rare fibrinogen variant.


Assuntos
Afibrinogenemia/diagnóstico , Afibrinogenemia/genética , Erros de Diagnóstico , Fibrinogênio , Testes de Coagulação Sanguínea/métodos , Feminino , Fibrinogênio/genética , Fibrinogênio/metabolismo , Humanos , Masculino , Mutação , Reino Unido
5.
Int J Lab Hematol ; 39(4): 350-358, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28406553

RESUMO

INTRODUCTION: FXIII deficiency is a rare bleeding disorders, and specific FXIII assays are recommended to detect this deficiency. We investigated the performance and accuracy of FXIII investigations in two exercises, comparing centres enrolled in the PRO-RBDD project (prospective data collection on patients with fibrinogen and Factor XIII deficiencies), and UK NEQAS BC centres. METHODS: Samples from a FXIII deficient subject and a normal donor were sent to participating centres, to investigate for FXIII deficiency, and interpret their results. Median, coefficient of variation and range were determined. RESULTS: Results were returned from 98 UK NEQAS BC and 28 PRO-RBDD centres. Up to 40% of UK NEQAS BC and 52% of PRO-RBDD centres reported clot solubility results - with diagnostic errors by two NEQAS BC centres (false negatives for the FXIII deficient sample) and one PRO-RBDD centre (false positive for the normal sample). Over 70% of UK NEQAS BC centres and PRO-RBDD centres performed FXIII assays. Median results were similar between the two groups, with the exception of sample 3 in survey 2 (5.5 vs. 14.0 µ/dl for UK NEQAS BC and PRO-RBDD centres respectively, P < 0.001). Diagnostic errors were made by 2 UK NEQAS BC centres. CONCLUSION: Approximately 70% of centres now employ FXIII assays, complying with international recommendations. However, solubility tests continue to be used. Our data show this can be successful, depending on the sensitivity of the method in use. Diagnostic errors are made by centres using both solubility screens and FXIII assays, and laboratories should ensure good quality assurance procedures to improve diagnostic accuracy.


Assuntos
Deficiência do Fator XIII/diagnóstico , Coagulação Sanguínea , Testes de Coagulação Sanguínea/métodos , Testes de Coagulação Sanguínea/normas , Serviços de Laboratório Clínico/normas , Fator XIII , Deficiência do Fator XIII/sangue , Feminino , Pesquisas sobre Atenção à Saúde , Humanos , Laboratórios , Masculino , Garantia da Qualidade dos Cuidados de Saúde , Reprodutibilidade dos Testes , Reino Unido
6.
Haemophilia ; 22(5): 806-12, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27217329

RESUMO

INTRODUCTION: Although the variability in factor VIII (FVIII):C measurement is well recognized, this has not been widely reported for post-FVIII infusion samples. AIM/METHODS: Three samples from haemophilia A patients were distributed in a UK National External Quality Assessment Scheme survey, each after treatment with either ReFacto AF, Kogenate FS or Advate. Fifty-two UK haemophilia centres performed FVIII assays using one-stage (n = 46) and chromogenic (n = 10) assays. Centres calibrated assays with the local plasma standard and with ReFacto AF laboratory standard for the ReFacto AF sample. RESULTS/CONCLUSIONS: Chromogenic assays gave significantly higher results than one-stage assays (P < 0.0001, 32% difference) in the post-Kogenate sample but not in the post-ReFacto AF (11% higher by chromogenic assay, ns) or post-Advate samples (3% lower by chromogenic, ns) when assays were calibrated with plasma standards. Twenty centres used all Instrumentation Laboratory (IL)-activated partial thromboplastin time reagents (Synthasil)/IL deficient plasma/reference plasma) in the one-stage assay and 15 used all Siemens reagents (Actin FS/Siemens deficient plasma/reference plasma); this made a significant difference to results post-ReFacto AF (41% higher by IL reagents, P < 0.0001) and Advate (39% higher by IL reagents, P < 0.0001), but not Kogenate (7% higher by IL, ns) when calibrated with plasma standards. Differences between results obtained with different one-stage assay reagents for monitoring Advate have implications for dosing patients. Furthermore, there was considerable inter-laboratory variation as indicated by CVs in the range 15-26% for chromogenic assay and 12-19% for one-stage assay results. This study suggests that external quality assessment schemes should offer participation in post-FVIII infusion schemes where haemophilic patients are monitored.


Assuntos
Testes de Coagulação Sanguínea , Coagulantes/análise , Fator VIII/análise , Testes de Coagulação Sanguínea/normas , Compostos Cromogênicos/química , Coagulantes/normas , Coagulantes/uso terapêutico , Fator VIII/normas , Fator VIII/uso terapêutico , Hemofilia A/tratamento farmacológico , Humanos , Tempo de Tromboplastina Parcial , Kit de Reagentes para Diagnóstico
9.
Int J Lab Hematol ; 37(4): 495-502, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25496193

RESUMO

INTRODUCTION: External quality assessment (EQA) is an important component of quality assurance for laboratory tests of haemostasis. Lyophilization of plasma confers stability of labile clotting factors, allowing valid comparison of results between participating centres. However, elevated ambient temperatures in some geographical areas could affect the stability of lyophilized samples in transit. METHODS: The effect on lyophilized plasma samples of consistent elevated temperature with respect to haemostasis tests was determined in a single centre. The temperature to which packages were exposed during transit was also monitored. RESULTS: Survey packages were exposed to average temperatures up to 31.9 °C and maximum temperatures up to 39.7 °C over delivery periods between 1 and 8 weeks. In-house studies revealed samples to be stable over a 6-week period at a constant 30 °C, and only small changes were observed for samples exposed to 37 °C for 4 weeks. 6-week storage at 37 °C was associated with average changes of up to 15% in factor assay activity. CONCLUSION: Lyophilized EQA material employed in UK NEQAS surveys is stable under conditions encountered for the majority of participants, but in cases of delayed delivery of samples, the effect of temperature on sample integrity must be considered when assessing laboratory performance.


Assuntos
Testes de Coagulação Sanguínea/normas , Proteínas Sanguíneas/química , Plasma/química , Liofilização , Humanos , Estabilidade Proteica , Controle de Qualidade , Temperatura
10.
Int J Lab Hematol ; 35(2): 177-82, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23113926

RESUMO

INTRODUCTION: The APTT is widely employed as part of a coagulation screening panel, used as a pre-operative assessment of bleeding risk, to detect hereditary and acquired haemostatic defects and to monitor anticoagulant therapy. External quality assessment (EQA) exercises assess laboratory performance of individual tests, but rarely assess the approach to investigation of an abnormal result. METHODS: A multicentre exercise was carried out to investigate the ability of laboratories to identify the cause of a prolonged APTT. A sample was distributed with a request to carry out whichever tests were considered necessary to achieve a probable diagnosis. RESULTS: One hundred and ten centres in the UK NEQAS programme took part, and all 104 centres providing an interpretation correctly identified deficiency of FVIII in the sample. However, of these, 10 centres reported additional defects, including lupus anticoagulant, FIX deficiency, FXII deficiency and a FVIII inhibitor. CONCLUSIONS: A markedly varied approach to investigation of a prolonged APTT was observed, although a lack of clinical information may have contributed to this finding.


Assuntos
Transtornos da Coagulação Sanguínea/diagnóstico , Tempo de Tromboplastina Parcial/métodos , Tempo de Tromboplastina Parcial/normas , Humanos , Estudos Multicêntricos como Assunto
11.
Haemophilia ; 18 Suppl 4: 66-72, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22726086

RESUMO

von Willebrand disease (VWD) is the most common inherited bleeding disorder, but variable severity and several classification types mean that diagnosis is often not straightforward. In many countries, the assays are not readily available and/or are not well standardized. The latest methods and the basis of VWD are discussed here, together with information from the international quality assessment programme (IEQAS). Factor XIII deficiency is a rare, but important bleeding disorder, which may be missed or diagnosed late. A discussion and update on this diagnosis is considered in the final section of our review.


Assuntos
Técnicas de Laboratório Clínico/normas , Deficiência do Fator XIII/diagnóstico , Doenças de von Willebrand/diagnóstico , Colágeno , Hemaglutininas , Hemofilia A/diagnóstico , Humanos , Agregação Plaquetária , Controle de Qualidade , Ristocetina , Fator de von Willebrand/metabolismo
12.
Haemophilia ; 18 Suppl 4: 73-80, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22726087

RESUMO

Congenital defects of platelets or plasma proteins involved in blood coagulation generally lead to bleeding disorders. In some of these disorders, patients with a severe phenotype are prone to spontaneous bleeds with critical consequences. This situation occurs more commonly in haemophilia A and haemophilia B and to a certain extent in severe forms (type 3) of von Willebrand disease. Defects in other plasma coagulation proteins and platelet factors are relatively rare, with an incidence of ≤ 1: 1-2 million. Molecular genetic studies of the human coagulation factors, especially factors VIII and IX, have contributed to a better understanding of the biology of these genetic disorders, the accurate detection of carriers and genetic counselling, and have also fostered new therapeutic strategies. This article reviews the evolution of genetics over the last five decades as a tool for bleeding disorder investigations, the recent advances in molecular techniques that have contributed to improved genetic diagnosis of this condition, and the development and utility of proficiency testing programmes and reference materials for genetic diagnosis of bleeding disorders.


Assuntos
Transtornos da Coagulação Sanguínea/genética , Fatores de Coagulação Sanguínea/genética , Hemostasia/genética , Biologia Molecular/métodos , Transtornos da Coagulação Sanguínea/diagnóstico , Humanos , Análise de Sequência de DNA
14.
Int J Lab Hematol ; 34(1): 70-80, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21752234

RESUMO

INTRODUCTION: The quality of anticoagulation management is not readily or frequently assessed, particularly between different centres. This study sought to evaluate agreement in oral anticoagulant management decisions between participating centres in UK NEQAS programmes. METHODS: Participants were asked to indicate whether they used computerized dosing support software (CDSS) and to complete a series of questions with respect to anticoagulant management provision. Four clinical scenarios were provided, together with past and current International Normalised Ratio (INR) results. Participants were asked to provide recommendations on the target INR they would assign to the patient, the dose of warfarin and a recall interval. RESULTS: Seven hundred and fifty-nine centres returned results, of which 28% were enrolled in the hospital-based EQA programme, and 72% were participants in the point-of-care testing programme. Six hundred (79%) reported use of CDSS. In one straightforward scenario, there was 99% agreement in dose recommendation. However, for three more complex scenarios, differences were apparent in target INRs employed and both dose and recall recommendations. In some cases, differences related to the software system employed. CONCLUSION: The study emphasizes large variation in the approach to managing these scenarios and warrants further investigation, together with education including promoting national guidelines for the assignment of target ranges.


Assuntos
Anticoagulantes/administração & dosagem , Sistemas de Medicação , Software , Administração Oral , Adulto , Idoso , Anticoagulantes/uso terapêutico , Transtornos da Coagulação Sanguínea/tratamento farmacológico , Feminino , Humanos , Coeficiente Internacional Normatizado , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários , Varfarina/administração & dosagem
16.
Peptides ; 31(2): 284-90, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19944725

RESUMO

We have previously demonstrated that pregnant ovine endometrium expresses the gastrin-releasing peptide (GRP) gene at a high level following conceptus implantation. Here we report the isolation, characterization and biological activity of ovine GRP 1-46, the primary product of this gene in the pregnant endometrium. Full thickness 125-140-day pregnant sheep uterus (term is 145 day) was homogenized in 80% acetonitrile/2% trifluoroacetic acid (1:7 ACN/TFA), concentrated on reverse-phase C18 cartridges and chromatographed successively on gel filtration (Sephadex G-50) and reverse-phase HPLC (C18 muBondapak). Purification was monitored by RIA. Purified GRP peptide was analysed by mass spectrometry giving a major mass ion at 4963 which corresponds exactly to GRP 1-46. Other mass ions from pro-GRP did not contain a biologically active N-terminus or antigenic determinant. Proteolytic cleavage of pro-GRP to give rise to GRP(1-46) would require preferential cleavage at the Glu-Glu bond by a Glu-C2-like enzyme, rather than the trypsin-like and C-terminal amidation enzymes (PAM) that produce GRP(18-27) and GRP(1-27) in other tissues. GRP 1-46 was synthesized and receptor binding and biological activity tested on a range of rodent and human cell lines that express GRP-related receptors GRPR, NMBR and BRS3. GRP 1-46 bound GRPR and NMBR with low affinity, and mobilized inositol phosphate in cell lines expressing the GRPR and NMBR, but not BRS-3. This study describes a new processed product of the GRP gene, GRP 1-46, which is highly expressed in the pregnant sheep endometrium and which acts as a weak agonist at the GRPR and NMBR.


Assuntos
Endométrio/química , Peptídeo Liberador de Gastrina/isolamento & purificação , Peptídeo Liberador de Gastrina/farmacologia , Sequência de Aminoácidos , Animais , Linhagem Celular , Linhagem Celular Tumoral , Feminino , Peptídeo Liberador de Gastrina/análise , Peptídeo Liberador de Gastrina/metabolismo , Humanos , Indóis/farmacologia , Fosfatos de Inositol/metabolismo , Camundongos , Dados de Sequência Molecular , Peso Molecular , Peptídeos/genética , Gravidez , Ligação Proteica/fisiologia , Precursores de Proteínas/genética , Piridinas/farmacologia , Ratos , Receptores da Bombesina/antagonistas & inibidores , Receptores da Bombesina/genética , Receptores da Bombesina/metabolismo , Ovinos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Transfecção , Fosfolipases Tipo C/metabolismo
18.
Haemophilia ; 15(2): 571-7, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19175423

RESUMO

External quality assessment (EQA) has been shown to improve laboratory performance and diagnosis in haemostasis. We report here findings from the World Federation of Haemophilia (WFH) EQA programme during the period 2004-2007. Samples for PT, APTT, FVIII:C, FIX:C and VWF assays were distributed to centres in both established and emerging countries, and results were compared with results obtained by United Kingdom National External Quality Assessment Scheme (UK NEQAS) participants on the same samples. In general, good agreement was seen throughout between WFH and UK NEQAS for screening tests, and it was possible to identify an improvement in WFH centre agreement for results for VWF assays during the period of study. Agreement between emerging and established WFH centres was comparable for screening tests, possibly indicative of the relative simplicity of these tests and the degree of automation now employed in almost all haemostasis laboratories. However, CVs and performance compared with UK NEQAS participant results for factor assays amongst established centres was better than between emerging centres. Distribution of a questionnaire revealed different application of methodology for these assays, which may contribute to the observed difference in performance. Several centres participated in supplementary exercises, with comparable results obtained by emerging and established centres performing FVIII and fibrinogen measurement on cryoprecipitate, and all centres performing FVIII inhibitor assays correctly identifying the presence of an inhibitor. Participation in EQA programmes should continue to encourage improvement in laboratory performance and therefore improvements in the diagnosis and care of patients with haemophilia.


Assuntos
Técnicas de Laboratório Clínico/normas , Transtornos Hemorrágicos/diagnóstico , Hemostasia , Garantia da Qualidade dos Cuidados de Saúde/normas , Fator IX/análise , Fator VIII/análise , Humanos , Tempo de Protrombina , Inquéritos e Questionários , Fator de von Willebrand/análise
19.
J Clin Pathol ; 61(8): 950-4, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18663056

RESUMO

AIMS: Platelet function testing forms an important part of the laboratory investigation of a bleeding tendency; however, little standardisation and quality control is available for these tests. A UK National External Quality Assessment Scheme (UK NEQAS) for Blood Coagulation exercise sought to identify current practice among laboratories performing platelet function tests. METHODS: A questionnaire was circulated in March 2006 to establish the current status of platelet function testing practice among participants of UK NEQAS. Participants were asked specifically about practice in bleeding time testing, PFA-100 analyser use, platelet aggregometry methodology and additional tests of platelet function. RESULTS: 169 returned questionnaires revealed that 26 centres used bleeding time, the PFA-100 analyser and platelet aggregometry in their investigations; 13 used bleeding time and the PFA-100 only; 33 used bleeding time and platelet aggregometry; and 23 used the PFA-100 with platelet aggregometry. 58 centres reported that they performed only bleeding times in their investigations, 10 reported use of the PFA-100 only, and 6 reported use of aggregometry only. Marked variability was observed in methodology for each of these tests, and in many cases no form of quality control was employed. CONCLUSIONS: The data confirmed the lack of standardisation in methodology employed in different centres. Updated guidelines and standardisation of platelet function assessment are required to facilitate comparability between centres.


Assuntos
Transtornos Plaquetários/diagnóstico , Testes de Função Plaquetária/normas , Prática Profissional/normas , Tempo de Sangramento , Coleta de Amostras Sanguíneas/métodos , Humanos , Laboratórios/normas , Agregação Plaquetária , Testes de Função Plaquetária/métodos , Prática Profissional/estatística & dados numéricos , Garantia da Qualidade dos Cuidados de Saúde , Valores de Referência , Reino Unido
20.
J Thromb Haemost ; 6(3): 464-9, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18088346

RESUMO

BACKGROUND AND AIMS: External quality assessment (EQA) should be an inherent component of patient self management (PSM) of oral anticoagulation. The aim of this study was to evaluate methods of EQA for patients within a cluster randomized trial. METHOD: After development of methods, general practises were randomly allocated to a formal EQA scheme of patients performing the test independently at home or at their practise with supervision. The supervised group of practises was further sub divided to test two other EQA methods: (i) venous sample compared with patients' point of care (POC) device; and (ii) patients POC compared with reference POC. Primary trial outcome measure was reliability of results from the formal scheme taking into account adherence and test errors. RESULTS: Proportion of EQA scheme tests in range was 633/836 (75.7%). Proportion in range was significantly higher in group performing independently compared with supervised group, 80.1% vs. 71.5% respectively, P = 0.02. Sixty-six percent of tests were in range with venous compared with patients POC, and 88% in patients POC compared with reference POC. CONCLUSION: Patients are able to undertake a formal EQA scheme and perform more reliably at home independently. There are satisfactory alternatives if a formal scheme is not acceptable.


Assuntos
Anticoagulantes/administração & dosagem , Sistemas Automatizados de Assistência Junto ao Leito/normas , Administração Oral , Humanos , Cooperação do Paciente , Atenção Primária à Saúde , Avaliação de Programas e Projetos de Saúde , Garantia da Qualidade dos Cuidados de Saúde , Reprodutibilidade dos Testes , Autocuidado , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...