Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
1.
EuroIntervention ; 20(11): e718-e727, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38840576

RESUMO

BACKGROUND: Left atrial appendage occlusion (LAAO) is performed increasingly, but long-term follow-up imaging data are lacking. AIMS: The aim of this study was to evaluate the safety and durability of the Amplatzer Amulet device >4 years after LAAO. METHODS: This was a prospective observational cohort study including 52 patients implanted with the Amplatzer Amulet device at Aarhus University Hospital, Denmark. A >4-year follow-up cardiac computed tomography (CT) scan after LAAO was performed and compared with the results from the 2-month and 12-month scans. The primary outcome was left atrial appendage (LAA) sealing based on distal LAA contrast patency and peridevice leakage (PDL), stratified into complete occlusion (grade 0 [G0]) and grade 1-3 leakage (G1-3), respectively. Secondary outcomes were low- and high-grade hypoattenuated thickening (HAT), device-related thrombosis (DRT) and device durability. RESULTS: The median (interquartile range [IQR]) follow-up time from LAAO to the latest CT scan was 5.8 years (4.5; 6.3). At 2-month (n=52), 12-month (n=27) and >4-year CT follow-ups (n=52), rates of both complete occlusion (33%, 37%, 35%) and G2 leaks (52%, 52%, 48%) remained stable. Rates of G1 leaks varied (14%, 4%, 6%) and G3 leaks rose (2%, 7%, 12%) from earliest to latest follow-up. The median left atrial (LA) volume increased from 127 mL (96; 176) to 144 mL (108; 182) and 147 mL (107; 193). No DRT was found. The structural device integrity was preserved. CONCLUSIONS: This study indicates a stable LAA sealing status throughout the follow-up period, emphasising the importance of the procedural result in avoiding PDL. Few patients displayed PDL progression, which might partly be related to LA remodelling with increasing volume. The long-term device durability appears excellent. Larger studies are warranted to confirm these findings.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Tomografia Computadorizada por Raios X , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Apêndice Atrial/fisiopatologia , Masculino , Feminino , Idoso , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Estudos Prospectivos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Seguimentos , Pessoa de Meia-Idade , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação
2.
Artigo em Inglês | MEDLINE | ID: mdl-38789325

RESUMO

BACKGROUND: Coronary CT angiography (CCTA) is well-established for diagnosis and stratification of coronary artery disease (CAD). Its usefulness in guiding percutaneous coronary interventions (PCI) and stent sizing is unknown. METHODS: This is a sub-analysis of the Precise Percutaneous Coronary Intervention Plan (P3) study (NCT03782688). We analyzed 65 vessels with matched CCTA and pre-PCI optical coherence tomography (OCT) assessment. The CCTA-guided stent size was defined by the mean distal reference lumen diameter rounded up to the nearest stent diameter. The OCT lumen-guided stent size was the mean distal reference lumen diameter rounded to the closest stent diameter. The agreement on stent diameters was determined with Kappa statistics, Passing-Bablok regression analysis, and the Bland-Altman method. RESULTS: The distal reference lumen diameter by CCTA and OCT were 2.75 â€‹± â€‹0.53 â€‹mm and 2.72 â€‹± â€‹0.55 â€‹mm (mean difference 0.06, limits of agreement -0.7 to 0.82). There were no proportional or systematic differences (coefficient A 1.06, 95% CI 0.84 to 1.3 and coefficient B -0.22, 95% CI -0.83 to 0.36) between methods. The agreement between the CCTA and OCT stent size was substantial (Cohen's weighted Kappa 0.74, 95% CI 0.64 to 0.85). Compared to OCT stent diameter, CCTA stent size was concordant in 52.3% of the cases; CCTA overestimated stent size in 20.0% and underestimated in 27.7%. CONCLUSION: CCTA accurately assessed the reference vessel diameter used for stent sizing. CCTA-based stent sizing showed a substantial agreement with OCT. CCTA allows for PCI planning and may aid in selecting stent diameter.

3.
Am J Hypertens ; 37(7): 455-464, 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38477704

RESUMO

BACKGROUND: Chronic kidney disease (CKD) is associated with accelerated vascular calcification and increased central systolic blood pressure when measured invasively (invCSBP) relative to cuff-based brachial systolic blood pressure (cuffSBP). The contribution of aortic wall calcification to this phenomenon has not been clarified. We, therefore, examined the effects of aortic calcification on cuffSBP and invCSBP in a cohort of patients representing all stages of CKD. METHODS: During elective coronary angiography, invCSBP was measured in the ascending aorta with a fluid-filled catheter with simultaneous recording of cuffSBP using an oscillometric device. Furthermore, participants underwent a non-contrast computed tomography scan of the entire aorta with observer-blinded calcification scoring of the aortic wall ad modum Agatston. RESULTS: We included 168 patients (mean age 67.0 ±â€…10.5, 38 females) of whom 38 had normal kidney function, while 30, 40, 28, and 32 had CKD stages 3a, 3b, 4, and 5, respectively. Agatston scores adjusted for body surface area ranged from 48 to 40,165. We found that invCSBP increased 3.6 (95% confidence interval 1.4-5.7) mm Hg relative to cuffSBP for every 10,000-increment in aortic Agatston score. This association remained significant after adjustment for age, diabetes, antihypertensive treatment, smoking, eGFR, and BP level. No such association was found for diastolic BP. CONCLUSIONS: Patients with advanced aortic calcification have relatively higher invCSBP for the same cuffSBP as compared to patients with less calcification. Advanced aortic calcification in CKD may therefore result in hidden central hypertension despite apparently well-controlled cuffSBP. ClinicalTrials.gov identifier: NCT04114695.


Assuntos
Determinação da Pressão Arterial , Insuficiência Renal Crônica , Calcificação Vascular , Humanos , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Insuficiência Renal Crônica/fisiopatologia , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/fisiopatologia , Determinação da Pressão Arterial/métodos , Doenças da Aorta/fisiopatologia , Doenças da Aorta/diagnóstico por imagem , Pressão Sanguínea , Angiografia por Tomografia Computadorizada , Artéria Braquial/fisiopatologia , Artéria Braquial/diagnóstico por imagem , Angiografia Coronária , Aortografia , Valor Preditivo dos Testes
4.
J Am Heart Assoc ; 13(5): e032605, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38390822

RESUMO

BACKGROUND: Following percutaneous coronary intervention (PCI), optical coherence tomography provides prognosis information. The pullback pressure gradient is a novel index that discriminates focal from diffuse coronary artery disease based on fractional flow reserve pullbacks. We sought to investigate the association between coronary artery disease patterns, defined by coronary physiology, and optical coherence tomography after stent implantation in stable patients undergoing PCI. METHODS AND RESULTS: This multicenter, prospective, single-arm study was conducted in 5 countries (NCT03782688). Subjects underwent motorized fractional flow reserve pullbacks evaluation followed by optical coherence tomography-guided PCI. Post-PCI optical coherence tomography minimum stent area, stent expansion, and the presence of suboptimal findings such as incomplete stent apposition, stent edge dissection, and irregular tissue protrusion were compared between patients with focal versus diffuse disease. Overall, 102 patients (105 vessels) were included. Fractional flow reserve before PCI was 0.65±0.14, pullback pressure gradient was 0.66±0.14, and post-PCI fractional flow reserve was 0.88±0.06. The mean minimum stent area was 5.69±1.99 mm2 and was significantly larger in vessels with focal disease (6.18±2.12 mm2 versus 5.19±1.72 mm2, P=0.01). After PCI, incomplete stent apposition, stent edge dissection, and irregular tissue protrusion were observed in 27.6%, 10.5%, and 51.4% of the cases, respectively. Vessels with focal disease at baseline had a lower prevalence of incomplete stent apposition (11.3% versus 44.2%, P=0.002) and more irregular tissue protrusion (69.8% versus 32.7%, P<0.001). CONCLUSIONS: Baseline coronary pathophysiological patterns are associated with suboptimal imaging findings after PCI. Patients with focal disease had larger minimum stent area and a higher incidence of tissue protrusion, whereas stent malapposition was more frequent in patients with diffuse disease.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Humanos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Valor Preditivo dos Testes , Estudos Prospectivos , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento
5.
J Cardiovasc Comput Tomogr ; 18(3): 243-250, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38246785

RESUMO

BACKGROUND: The association between coronary computed tomography angiography (CTA) derived fractional flow reserve (FFRCT) and risk of recurrent angina in patients with new onset stable angina pectoris (SAP) and stenosis by CTA is uncertain. METHODS: Multicenter 3-year follow-up study of patients presenting with symptoms suggestive of new onset SAP who underwent first-line CTA evaluation and subsequent standard-of-care treatment. All patients had at least one ≥30 â€‹% coronary stenosis. A per-patient lowest FFRCT-value ≤0.80 represented an abnormal test result. Patients with FFRCT ≤0.80 who underwent revascularization were categorized according to completeness of revascularization: 1) Completely revascularized (CR-FFRCT), all vessels with FFRCT ≤0.80 revascularized; or 2) incompletely revascularized (IR-FFRCT) ≥1 vessels with FFRCT ≤0.80 non-revascularized. Recurrent angina was evaluated using the Seattle Angina Questionnaire. RESULTS: Amongst 769 patients (619 [80 â€‹%] stenosis ≥50 â€‹%, 510 [66 â€‹%] FFRCT ≤0.80), 174 (23 â€‹%) reported recurrent angina at follow-up. An FFRCT ≤0.80 vs â€‹> â€‹0.80 associated to increased risk of recurrent angina, relative risk (RR): 1.82; 95 â€‹% CI: 1.31-2.52, p â€‹< â€‹0.001. Risk of recurrent angina in CR-FFRCT (n â€‹= â€‹135) was similar to patients with FFRCT >0.80, 13 â€‹% vs 15 â€‹%, RR: 0.93; 95 â€‹% CI: 0.62-1.40, p â€‹= â€‹0.72, while IR-FFRCT (n â€‹= â€‹90) and non-revascularized patients with FFRCT ≤0.80 (n â€‹= â€‹285) had increased risk, 37 â€‹% vs 15 â€‹% RR: 2.50; 95 â€‹% CI: 1.68-3.73, p â€‹< â€‹0.001 and 30 â€‹% vs 15 â€‹%, RR: 2.03; 95 â€‹% CI: 1.44-2.87, p â€‹< â€‹0.001, respectively. Use of antianginal medication was similar across study groups. CONCLUSION: In patients with SAP and coronary stenosis by CTA undergoing standard-of-care guided treatment, FFRCT provides information regarding risk of recurrent angina.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Valor Preditivo dos Testes , Recidiva , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Fatores de Risco , Seguimentos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Estenose Coronária/terapia , Fatores de Tempo , Medição de Risco , Angina Estável/fisiopatologia , Angina Estável/diagnóstico por imagem , Angina Estável/terapia , Índice de Gravidade de Doença , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Prognóstico
6.
Eur Radiol ; 34(4): 2677-2688, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37798406

RESUMO

OBJECTIVE: To assess the accuracy of a virtual stenting tool based on coronary CT angiography (CCTA) and fractional flow reserve (FFR) derived from CCTA (FFRCT Planner) across different levels of image quality. MATERIALS AND METHODS: Prospective, multicenter, single-arm study of patients with chronic coronary syndromes and lesions with FFR ≤ 0.80. All patients underwent CCTA performed with recent-generation scanners. CCTA image quality was adjudicated using the four-point Likert scale at a per-vessel level by an independent committee blinded to the FFRCT Planner. Patient- and technical-related factors that could affect the FFRCT Planner accuracy were evaluated. The FFRCT Planner was applied mirroring percutaneous coronary intervention (PCI) to determine the agreement with invasively measured post-PCI FFR. RESULTS: Overall, 120 patients (123 vessels) were included. Invasive post-PCI FFR was 0.88 ± 0.06 and Planner FFRCT was 0.86 ± 0.06 (mean difference 0.02 FFR units, the lower limit of agreement (LLA) - 0.12, upper limit of agreement (ULA) 0.15). CCTA image quality was assessed as excellent (Likert score 4) in 48.3%, good (Likert score 3) in 45%, and sufficient (Likert score 2) in 6.7% of patients. The FFRCT Planner was accurate across different levels of image quality with a mean difference between FFRCT Planner and invasive post-PCI FFR of 0.02 ± 0.07 in Likert score 4, 0.02 ± 0.07 in Likert score 3 and 0.03 ± 0.08 in Likert score 2, p = 0.695. Nitrate dose ≥ 0.8mg was the only independent factor associated with the accuracy of the FFRCT Planner (95%CI - 0.06 to - 0.001, p = 0.040). CONCLUSION: The FFRCT Planner was accurate in predicting post-PCI FFR independent of CCTA image quality. CLINICAL RELEVANCE STATEMENT: Being accurate in predicting post-PCI FFR across a wide spectrum of CT image quality, the FFRCT Planner could potentially enhance and guide the invasive treatment. Adequate vasodilation during CT acquisition is relevant to improve the accuracy of the FFRCT Planner. KEY POINTS: • The fractional flow reserve derived from coronary CT angiography (FFRCT) Planner is a novel tool able to accurately predict fractional flow reserve after percutaneous coronary intervention. • The accuracy of the FFRCT Planner was confirmed across a wide spectrum of CT image quality. Nitrates dose at CT acquisition was the only independent predictor of its accuracy. • The FFRCT Planner could potentially enhance and guide the invasive treatment.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Estudos Prospectivos , Tomografia Computadorizada por Raios X , Angiografia Coronária/métodos , Angiografia por Tomografia Computadorizada/métodos , Estenose Coronária/terapia , Valor Preditivo dos Testes
7.
Int J Cardiol ; 399: 131668, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38141723

RESUMO

BACKGROUND AND AIMS: Coronary hemodynamics impact coronary plaque progression and destabilization. The aim of the present study was to establish the association between focal vs. diffuse intracoronary pressure gradients and wall shear stress (WSS) patterns with atherosclerotic plaque composition. METHODS: Prospective, international, single-arm study of patients with chronic coronary syndromes and hemodynamic significant lesions (fractional flow reserve [FFR] ≤ 0.80). Motorized FFR pullback pressure gradient (PPG), optical coherence tomography (OCT), and time-average WSS (TAWSS) and topological shear variation index (TSVI) derived from three-dimensional angiography were obtained. RESULTS: One hundred five vessels (median FFR 0.70 [Interquartile range (IQR) 0.56-0.77]) had combined PPG and WSS analyses. TSVI was correlated with PPG (r = 0.47, [95% Confidence Interval (95% CI) 0.30-0.65], p < 0.001). Vessels with a focal CAD (PPG above the median value of 0.67) had significantly higher TAWSS (14.8 [IQR 8.6-24.3] vs. 7.03 [4.8-11.7] Pa, p < 0.001) and TSVI (163.9 [117.6-249.2] vs. 76.8 [23.1-140.9] m-1, p < 0.001). In the 51 vessels with baseline OCT, TSVI was associated with plaque rupture (OR 1.01 [1.00-1.02], p = 0.024), PPG with the extension of lipids (OR 7.78 [6.19-9.77], p = 0.003), with the presence of thin-cap fibroatheroma (OR 2.85 [1.11-7.83], p = 0.024) and plaque rupture (OR 4.94 [1.82 to 13.47], p = 0.002). CONCLUSIONS: Focal and diffuse coronary artery disease, defined using coronary physiology, are associated with differential WSS profiles. Pullback pressure gradients and WSS profiles are associated with atherosclerotic plaque phenotypes. Focal disease (as identified by high PPG) and high TSVI are associated with high-risk plaque features. CLINICAL TRIAL REGISTRATION: https://clinicaltrials,gov/ct2/show/NCT03782688.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Placa Aterosclerótica , Humanos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Hemodinâmica , Fenótipo , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Valor Preditivo dos Testes , Estudos Prospectivos
8.
Eur Heart J Case Rep ; 7(12): ytad571, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38046651

RESUMO

Background: Intracardiac echocardiography (ICE)-guided left atrial appendage occlusion (LAAO) is increasingly common. Patients with previous atrial septal defect closure constitute a significant challenge for transseptal access. Case summary: A 49-year-old man with persistent atrial fibrillation, hypertension, and reduced left ventricular function was considered for LAAO after a life-threatening intrathoracic bleeding while on oral anticoagulation. Percutaneous atrial septal defect closure was performed 15 years before with a 34 mm Amplatzer Septal Occluder. Preprocedural cardiac computed tomography demonstrated the atrial septal occluder device with a small native interatrial septum at the inferior margin. The left atrial appendage landing zone measured 17 × 22 mm. The LAAO was performed under local analgesia. A steerable sheath was used to guide the transseptal puncture, and the ICE probe was traced along a guidewire across the atrial septum. A 12-F Amulet delivery sheath was advanced through the same transseptal hole. Under ICE and fluoroscopy guidance, a 25 mm Amplatzer Amulet was deployed. Follow-up imaging showed a well-positioned device with a small peridevice leak at the disc. Discussion: This case report illustrates the feasibility of LAAO performed with ICE guidance from the left atrium in a patient with a large Amplatzer Septal Occluder with a small native interatrial septum. It demonstrates that prior atrial septal defect closure should not be considered as a contraindication for LAAO but warrants careful preprocedural planning.

9.
Artigo em Inglês | MEDLINE | ID: mdl-37882993

RESUMO

BACKGROUND: Amplatzer Amulet is a frequently used device for left atrial appendage occlusion (LAAO). The current sizing protocol is based on the maximum diameter of the left atrial appendage (LAA) landing zone. However, mean, perimeter-, or area-derived diameter might be more accurate measures for device sizing. METHODS: Retrospective analysis of 150 consecutive patients undergoing LAAO is guided by pre-procedural cardiac CT. A total of 117 patients were included; 7 were excluded due to renal failure and 26 due to closure with the sandwich technique. The maximum, mean, area-, and perimeter-derived diameters of the landing zone were derived from pre-procedural cardiac CT scans, and their accuracy to predict the implanted device size was investigated. The predicted device size was determined based on the currently recommended sizing algorithm. Peri-device leak (PDL) was assessed (grade 1-3) along with the underlying mechanism. RESULTS: Device-sizing accuracy was superior for mean, area-, and perimeter derived diameters compared with the maximal diameter, especially for eccentric landing zones. Mean difference between predicted and actually implanted device size was 0.08 mm (± 2.77), 0.30 mm (± 2.40), - 0.39 mm (± 2.43), and - 2.55 mm (± 2.57) across mean, area-derived, perimeter-derived, and maximal diameter, respectively. Grade 3 peri-device leak was seen in 8.5% of implants without a significant association to the eccentricity of the landing zone. The leading mechanism for PDL was device malalignment. CONCLUSION: Our results indicate mean, area-, and perimeter-derived diameters of the device landing zone to perform similar and superior in device-sizing accuracy compared with the maximum diameter.

10.
JACC Cardiovasc Imaging ; 16(11): 1452-1464, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37480908

RESUMO

BACKGROUND: The interplay between coronary hemodynamics and plaque characteristics remains poorly understood. OBJECTIVES: The aim of this study was to compare atherosclerotic plaque phenotypes between focal and diffuse coronary artery disease (CAD) defined by coronary hemodynamics. METHODS: This multicenter, prospective, single-arm study was conducted in 5 countries. Patients with functionally significant lesions based on an invasive fractional flow reserve ≤0.80 were included. Plaque analysis was performed by using coronary computed tomography angiography and optical coherence tomography. CAD patterns were assessed using motorized fractional flow reserve pullbacks and quantified by pullback pressure gradient (PPG). Focal and diffuse CAD was defined according to the median PPG value. RESULTS: A total of 117 patients (120 vessels) were included. The median PPG was 0.66 (IQR: 0.54-0.75). According to coronary computed tomography angiography analysis, plaque burden was higher in patients with focal CAD (87% ± 8% focal vs 82% ± 10% diffuse; P = 0.003). Calcifications were significantly more prevalent in patients with diffuse CAD (Agatston score per vessel: 51 [IQR: 11-204] focal vs 158 [IQR: 52-341] diffuse; P = 0.024). According to optical coherence tomography analysis, patients with focal CAD had a significantly higher prevalence of circumferential lipid-rich plaque (37% focal vs 4% diffuse; P = 0.001) and thin-cap fibroatheroma (TCFA) (47% focal vs 10% diffuse; P = 0.002). Focal disease defined by PPG predicted the presence of TCFA with an area under the curve of 0.73 (95% CI: 0.58-0.87). CONCLUSIONS: Atherosclerotic plaque phenotypes associate with intracoronary hemodynamics. Focal CAD had a higher plaque burden and was predominantly lipid-rich with a high prevalence of TCFA, whereas calcifications were more prevalent in diffuse CAD. (Precise Percutaneous Coronary Intervention Plan [P3]; NCT03782688).


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Placa Aterosclerótica , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Estudos Prospectivos , Angiografia Coronária/métodos , Valor Preditivo dos Testes , Fenótipo , Lipídeos
11.
Circulation ; 147(14): 1053-1063, 2023 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-36621817

RESUMO

BACKGROUND: Low-density lipoprotein cholesterol (LDL-C) is an important causal risk factor for atherosclerotic cardiovascular disease (ASCVD). However, a sizable proportion of middle-aged individuals with elevated LDL-C level have not developed coronary atherosclerosis as assessed by coronary artery calcification (CAC). Whether presence of CAC modifies the association of LDL-C with ASCVD risk is unknown. We evaluated the association of LDL-C with future ASCVD events in patients with and without CAC. METHODS: The study included 23 132 consecutive symptomatic patients evaluated for coronary artery disease using coronary computed tomography angiography (CTA) from the Western Denmark Heart Registry, a seminational, multicenter-based registry with longitudinal registration of patient and procedure data. We assessed the association of LDL-C level obtained before CTA with ASCVD (myocardial infarction and ischemic stroke) events occurring during follow-up stratified by CAC>0 versus CAC=0 using Cox regression models adjusted for baseline characteristics. Outcomes were identified through linkage among national registries covering all hospitals in Denmark. We replicated our results in the National Heart, Lung, and Blood Institute-funded Multi-Ethnic Study of Atherosclerosis. RESULTS: During a median follow-up of 4.3 years, 552 patients experienced a first ASCVD event. In the overall population, LDL-C (per 38.7 mg/dL increase) was associated with ASCVD events occurring during follow-up (adjusted hazard ratio [aHR], 1.14 [95% CI, 1.04-1.24]). When stratified by the presence or absence of baseline CAC, LDL-C was only associated with ASCVD in the 10 792/23 132 patients (47%) with CAC>0 (aHR, 1.18 [95% CI, 1.06-1.31]); no association was observed among the 12 340/23 132 patients (53%) with CAC=0 (aHR, 1.02 [95% CI, 0.87-1.18]). Similarly, a very high LDL-C level (>193 mg/dL) versus LDL-C <116 mg/dL was associated with ASCVD in patients with CAC>0 (aHR, 2.42 [95% CI, 1.59-3.67]) but not in those without CAC (aHR, 0.92 [0.48-1.79]). In patients with CAC=0, diabetes, current smoking, and low high-density lipoprotein cholesterol levels were associated with future ASCVD events. The principal findings were replicated in the Multi-Ethnic Study of Atherosclerosis. CONCLUSIONS: LDL-C appears to be almost exclusively associated with ASCVD events over ≈5 years of follow-up in middle-aged individuals with versus without evidence of coronary atherosclerosis. This information is valuable for individualized risk assessment among middle-aged people with or without coronary atherosclerosis.


Assuntos
Aterosclerose , Doenças Cardiovasculares , Doença da Artéria Coronariana , Calcificação Vascular , Pessoa de Meia-Idade , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/complicações , LDL-Colesterol , Doenças Cardiovasculares/complicações , Fatores de Risco , Medição de Risco/métodos , Sistema de Registros , Dinamarca/epidemiologia , Calcificação Vascular/complicações
12.
Eur Heart J Cardiovasc Pharmacother ; 9(3): 208-219, 2023 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-36269306

RESUMO

AIMS: Beyond 1 year after percutaneous coronary intervention (PCI), guidelines recommend anticoagulant monotherapy in patients with atrial fibrillation (AF) rather than dual therapy with an anticoagulant and an antiplatelet drug. The risks and benefits of this strategy, however, remain uncertain. We examined hospitalization for bleeding and ischaemic risk beyond 1 year after PCI in patients with AF treated with monotherapy vs. dual therapy. Furthermore, among patients treated with monotherapy, we compared direct oral anticoagulant (DOAC) therapy and vitamin K antagonist (VKA) therapy. METHODS AND RESULTS: We included all patients with AF undergoing first-time PCI between 2003 and 2017 from the Western Denmark Heart Registry and followed them for up to 4 years. Follow-up started 15 months after PCI to enable assessment of medical treatment after 12 months. Using a Cox regression model, we computed weighted hazard ratios (HRw) of hospitalization for bleeding and major adverse cardiac events (MACEs). Analyses comparing monotherapy vs. dual therapy included 3331 patients, and analyses comparing DOAC vs. VKA monotherapy included 1275 patients. Risks of hospitalization for bleeding [HRw 0.90, 95% confidence interval (CI) 0.75-1.09] and MACE (HRw 1.04, 95% CI 0.90-1.19) were similar with monotherapy and dual therapy. Similarly, risks of hospitalization for bleeding (HRw 1.27, 95% CI 0.84-1.92) and MACE (HRw 1.15, 95% CI 0.87-1.50) were equal with DOAC and VKA monotherapy. CONCLUSION: Our results support long-term OAC monotherapy beyond 1 year after PCI in patients with atrial fibrillation and suggest that DOAC monotherapy is as safe and effective as VKA monotherapy.


Assuntos
Fibrilação Atrial , Intervenção Coronária Percutânea , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/induzido quimicamente , Fibrinolíticos/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Inibidores da Agregação Plaquetária/efeitos adversos , Anticoagulantes/efeitos adversos , Hemorragia/induzido quimicamente
14.
Eur Heart J Cardiovasc Imaging ; 24(2): 250-259, 2023 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-36336848

RESUMO

AIMS: Cardiac computed tomography (CT) is increasingly utilized during follow-up after left atrial appendage closure (LAAC). Hypoattenuated thickening (HAT) is a common finding and might represent either benign device healing or device-related thrombosis (DRT). The appearance and characteristics of HAT associated with the Watchman FLX have not been previously described. Therefore, we sought to investigate cardiac CT findings during follow-up after Watchman FLX implantation with a focus on HAT and DRT. METHODS AND RESULTS: Retrospective single-centre, observational study including all patients with successful Watchman FLX implantation and follow-up cardiac CT between March 2019 and September 2021 (n = 244). Blinded analysis of CT images was performed describing the localization, extent, and morphology of HAT and correlated to imaging and histology findings in a canine model. Relevant clinical and preclinical ethical approvals were obtained.Overall, HAT was present in 156 cases (64%) and could be classified as either subfabric hypoattenuation (n = 59), flat sessile HAT (n = 78), protruding sessile HAT (n = 16), or pedunculated HAT (n = 3). All cases of pedunculated HAT and five cases of protruding sessile HAT were considered as high-grade HAT (n = 7). Subfabric hypoattenuation and flat sessile HAT correlated with device healing and endothelialization in histological analysis of explanted devices. CONCLUSION: Subfabric hypoattenuation and flat sessile HAT are frequent CT findings for Watchman FLX, likely representing benign device healing and endothelialization. Pedunculated HAT and protruding HAT are infrequent CT findings that might represent DRT.


Assuntos
Fibrilação Atrial , Trombose , Animais , Cães , Resultado do Tratamento , Estudos Retrospectivos , Ecocardiografia Transesofagiana , Tomografia , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/cirurgia
15.
J Interv Card Electrophysiol ; 66(2): 391-401, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35951214

RESUMO

BACKGROUND: The left atrial appendage (LAA) sealing properties of the Amplatzer Amulet and Watchman FLX devices were compared using cardiac computed tomography (CT) follow-up. METHODS: Single-center cohort study of patients undergoing LAAO between 2017 and 2020. Two consecutive cohorts were enrolled, one treated with the Amplatzer Amulet (n = 150) up till 2019, and a second cohort treated with the Watchman FLX (n = 150) device from 2019. Cardiac CT was performed 2 months postprocedure. The primary outcome was complete LAA occlusion defined as no visible peri-device leak (PDL) and absence of contrast patency in the distal LAA. Secondary outcomes included PDL, contrast patency without visible PDL, PDL area, and periprocedural complications. RESULTS: Complete occlusion was achieved in 39 (30.5%) of the Amulet group, compared to 89 (71.8%) of the FLX group, p < 0.001. A PDL at the Amulet disc was present in 65 (50.8%), at the lobe in 16 (12.5%), and at both the disc and lobe in 13 (10.2%). For FLX, a PDL was present in 20 (16.1%). Contrast patency without visible PDL was observed in 24 (18.8%) and 15 (12.1%) of the Amulet and FLX group, respectively. The PDL area at the Amulet mid-lobe was 92 mm2 (59-158) and 32 mm2 (IQR 28-96) for FLX, p = 0.019. Device-related thrombosis occurred in 1 (0.7%) and 2 (1.3%), respectively (p = 0.99), with periprocedural adverse events occurring in 6 (4%) and 8 (5.3%) of the Amulet and FLX group (p = 0.79). CONCLUSION: Complete LAA occlusion was achieved in a significantly higher proportion treated with the Watchman FLX compared to the Amulet device. PDL was smaller with the FLX than the Amulet. Conceptual device design differences make interpretation of results complex, and additional studies with clinical outcomes are needed.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Humanos , Estudos de Coortes , Apêndice Atrial/diagnóstico por imagem , Resultado do Tratamento , Cateterismo Cardíaco , Ecocardiografia Transesofagiana/métodos , Acidente Vascular Cerebral/etiologia
16.
Catheter Cardiovasc Interv ; 100(5): 801-809, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36153649

RESUMO

PURPOSE: The present article aims to compare a novel sizing chart based on both maximum and minimum diameters (novel MATRIX) with the current sizing recommendation instructions for use (IFU) based on the maximum diameter. BACKGROUND: Current IFU with the Amulet device are still based on the maximum left atrial appendage (LAA) diameter, which might lead to inappropriate oversizing, especially in elliptic appendages. METHODS: This was a retrospective analysis of patients undergoing LAA occlusion in two high-volume centers. Two hundred patients were included (100 patients with baseline cardiac computed tomography angiography [CCTA] and 100 with baseline 2D and 3D-transesophageal echocardiography [TEE]). The degree of concordance between the predicted device size recommendation and the actual device selection was the primary outcome. RESULTS: The novel MATRIX showed a higher level of concordance between the predicted and implanted device size, regardless of imaging modalities. CCTA showed the strongest, and 2D-TEE the weakest concordance between the predicted and implanted device for both MATRIX and IFU charts. The percentage of patients in whom the disagreement among the predicted and implanted device represented >1 size was higher when using the IFU chart. In elliptical LAA anatomies, the differences favoring the use of MATRIX compared to the IFU in terms of predicted/implanted agreement were higher. Finally, no significant differences in clinical or imaging endpoints were observed between the two different sizing charts. CONCLUSIONS: Incorporating both the LAA maximum and minimum diameters, as opposed to just maximum diameter, appears to improve sizing accuracy. The proposed MATRIX sizing chart offered a higher level of concordance between predicted and implanted device compared to the current IFU.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Estudos Retrospectivos , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Ecocardiografia Transesofagiana
17.
JACC Cardiovasc Imaging ; 15(7): 1242-1255, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35798401

RESUMO

BACKGROUND: Low fractional flow reserve (FFR) values after percutaneous coronary intervention (PCI) carry a worse prognosis than high post-PCI FFR values. Therefore, the ability to predict post-PCI FFR might play an important role in procedural planning. Post-PCI FFR values can now be computed from pre-PCI coronary computed tomography angiography (CTA) using the fractional flow reserve derived from coronary computed tomography angiography revascularization planner (FFRCT Planner). OBJECTIVES: The aim of this study was to validate the accuracy of the FFRCT Planner. METHODS: In this multicenter, investigator-initiated, prospective study, patients with chronic coronary syndromes and significant lesions based on invasive FFR ≤0.80 were recruited. The FFRCT Planner was applied to the fractional flow reserve derived from coronary computed tomography angiography (FFRCT) model, simulating PCI. The primary objective was the agreement between the predicted post-PCI FFR by the FFRCT Planner and measured post-PCI FFR. Accuracy of the FFRCT Planner's luminal dimensions was assessed by using post-PCI optical coherence tomography as the reference. RESULTS: Overall, 259 patients were screened, with 120 patients (123 vessels) included in the final analysis. The mean patient age was 64 ± 9 years, and 24% had diabetes. Measured FFR post-PCI was 0.88 ± 0.06, and the FFRCT Planner FFR was 0.86 ± 0.06 (mean difference: 0.02 ± 0.07 FFR unit; limits of agreement: -0.12 to 0.15). Optical coherence tomography minimal stent area was 5.60 ± 2.01 mm2, and FFRCT Planner minimal stent area was 5.0 ± 2.2 mm2 (mean difference: 0.66 ± 1.21 mm2; limits of agreement: -1.7 to 3.0). The accuracy and precision of the FFRCT Planner remained high in cases with focal and diffuse disease and with low and high calcium burden. CONCLUSIONS: The FFRCT-based technology was accurate and precise for predicting FFR after PCI. (Precise Percutaneous Coronary Intervention Plan Study [P3]; NCT03782688).


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Idoso , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Tomografia Computadorizada por Raios X
19.
Eur J Prev Cardiol ; 29(13): 1802-1810, 2022 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-35653637

RESUMO

AIMS: The Reduction of Cardiovascular Events with Icosapent Ethyl-Intervention Trial (REDUCE-IT) trial demonstrated that icosapent ethyl lowered the risk of atherosclerotic cardiovascular disease (ASCVD) among patients with elevated triglycerides. However, how to appropriately implement its use in clinical practice is not well-defined. We aimed to determine whether plaque burden as assessed by coronary artery calcium (CAC) could stratify ASCVD risk among patients eligible for icosapent ethyl. METHODS AND RESULTS: Among 23 759 patients who underwent computed tomography angiography (CTA) in the Western Denmark Heart Registry, we identified eligibility for the REDUCE-IT trial. A total of 2146 participants (9%) met enrolment criteria for REDUCE-IT. During a median of 4.3 years of follow-up, 146 ASCVD events occurred. Overall, there was a stepwise increase in ASCVD event rates per 1000 person-years with increasing CAC (CAC = 0: 10.5, CAC 1-299: 18.7, CAC ≥300: 49.8). REDUCE-IT-eligible patients with CAC ≥300 had a multivariable-adjusted hazard ratio of 3.1 compared with CAC = 0 (95% confidence interval: 1.9-4.9). Coronary artery calcium differentiated risk similarly in patients with and without obstructive coronary artery disease (CAD). Overall, the 5-year estimated number needed to treat to prevent one event with icosapent ethyl was 45 and ranged from 87 in those with CAC = 0 to 17 in those with CAC ≥300. Some patients with non-obstructive CAD had lower estimated number needed to treat than patients with obstructive CAD when their plaque burden was higher. CONCLUSION: Atherosclerotic plaque burden as assessed by CAC can identify REDUCE-IT-eligible patients who are expected to derive most, and least, absolute benefit from treatment with icosapent ethyl regardless of obstructive versus non-obstructive CAD status.


Assuntos
Aterosclerose , Doença da Artéria Coronariana , Placa Aterosclerótica , Calcificação Vascular , Humanos , Cálcio , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Dinamarca/epidemiologia , Sistema de Registros , Medição de Risco/métodos , Triglicerídeos , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/tratamento farmacológico , Calcificação Vascular/epidemiologia
20.
Am J Cardiol ; 176: 1-7, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35606174

RESUMO

The long-term cardiovascular risk for patients examined with coronary computed tomography angiography (CCTA) to rule out coronary heart disease compared with population controls remains unexplored. A nationwide register-based study including first-time CCTA-examined patients between 2007 and 2017 in Denmark alive 180 days post-CCTA was conducted. We evaluated 5-year outcomes of myocardial infarction (MI) or revascularization and all-cause mortality in 3 distinct CCTA-groups: (1) no post-CCTA preventive pharmacotherapy use (cholesterol-lowering drugs, antiplatelets, or anticoagulants); (2) post-CCTA preventive pharmacotherapy use; and (3) revascularization or MI within 180 days post-CCTA. For each patient group, population controls were matched on age, gender, and calendar year. Absolute risks standardized to the age, gender, selected co-morbidity, and anti-anginal pharmacotherapy distributions of the specific CCTA-examined patients and respective controls were obtained from multivariable Cox regression. Of 110,599 CCTA-examined patients, (1) 48,231 patients were not prescribed preventive pharmacotherapy 180 days post-CCTA; (2) 42,798 patients were prescribed preventive pharmacotherapy within 180 days post-CCTA; and (3) 19,570 patients were diagnosed with MI or revascularized within 180 days post-CCTA. For patient groups 1 to 3 versus respective controls, 5-year MI or revascularization risks were <0.1% versus 2.0%, <0.1% versus 3.8%, and 19.0% versus 2.5%, all p<0.001. Five-year all-cause mortality were 2.8% versus 4.2%, 5.5% versus 8.8%, and 6.7% versus 8.5%, all p <0.001. In conclusion, the 5-year MI or revascularization risk can be considered very low for CCTA-examined patients without ischemic events within 180 days post-CCTA. Conversely, CCTA-examined patients with MI or revascularization events within 180 days post-CCTA have significantly elevated 5-year MI or revascularization risk.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Dinamarca/epidemiologia , Seguimentos , Humanos , Infarto do Miocárdio/epidemiologia , Revascularização Miocárdica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...