Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
J Korean Soc Radiol ; 84(4): 941-945, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37559815

RESUMO

May-Thurner syndrome (MTS) is a rare cause of deep vein thrombosis. Several cases of MTS because of various causes have been reported. However, MTS due to osteophytes in patients with underlying diffuse idiopathic skeletal hyperostosis (DISH) has not been reported in English literature, to the best of our knowledge. Here, we present the CT findings of MTS in patient with DISH.

2.
Eur Radiol ; 29(5): 2518-2525, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30547203

RESUMO

OBJECTIVES: To compare the diagnostic performance and interpretation time of digital breast tomosynthesis (DBT) for both novice and experienced readers with and without using a computer-aided detection (CAD) system for concurrent read. METHODS: CAD system was developed for concurrent read in DBT interpretation. In this observer performance study, we used an enriched sample of 100 DBT cases including 70 with and 30 without breast cancers. Image interpretation was performed by four radiologists with different experience levels (two experienced and two novice). Each reader completed two reading sessions (at a minimum 2-month interval), once with and once without CAD. Three different rating scales were used to record each reader's interpretation. Reader performance with and without CAD was reported and compared for each radiologist. Reading time for each case was also recorded. RESULTS: Average area under the receiver operating characteristic curve values for BI-RADS scale on using CAD were 0.778 and 0.776 without using CAD, demonstrating no statistically significant differences. Results were consistent when the probability of malignancy and percentage probability of malignancy scales were used. Reading times per case were 72.07 s and 62.03 s (SD, 37.54 s vs 34.38 s) without and with CAD, respectively. The average difference in reading time on using CAD was a statistically significant decrease of 10.04 ± 1.85 s, providing 14% decrease in time. The time-reducing effect was consistently observed in both novice and experienced readers. CONCLUSION: DBT combined with CAD reduced interpretation time without diagnostic performance loss to novice and experienced readers. KEY POINTS: • The use of a concurrent DBT-CAD system shortened interpretation time. • The shortened interpretation time with DBT-CAD did not come at a cost to diagnostic performance to novice or experienced readers. • The concurrent DBT-CAD system improved the efficiency of DBT interpretation.


Assuntos
Neoplasias da Mama/diagnóstico , Diagnóstico por Computador/instrumentação , Mamografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Humanos , Pessoa de Meia-Idade , Curva ROC , Fatores de Tempo
3.
Comput Methods Programs Biomed ; 143: 113-120, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28391808

RESUMO

BACKGROUND AND OBJECTIVE: We propose a nipple detection algorithm for use with digital breast tomosynthesis (DBT) images. DBT images have been developed to overcome the weaknesses of 2D mammograms for denser breasts by providing 3D breast images. The nipple location acts as an invaluable landmark in DBT images for aligning the right and left breasts and describing the relative location of any existing lesions. METHODS: Nipples may be visible or invisible in a breast image, and therefore a nipple detection method must be able to detect the nipples for both cases. The detection method for visible nipples based on their shape is simple and highly efficient. However, it is difficult to detect invisible nipples because they do not have a prominent shape. Fibroglandular tissue in a breast is anatomically connected with the nipple. Thus, the nipple location can be detected by analyzing the location of such tissue. In this paper, we propose a method for detecting the location of both visible and invisible nipples using fibroglandular tissue and changes in the breast area. RESULTS: Our algorithm was applied to 138 DBT images, and its nipple detection accuracy was evaluated based on the mean Euclidean distance. The results indicate that our proposed method achieves a mean Euclidean distance of 3.10±2.58mm. CONCLUSIONS: The nipple location can be a very important piece of information in the process of a DBT image registration. This paper presents a method for the automatic nipple detection in a DBT image. The extracted nipple location plays an essential role in classifying any existing lesions and comparing both the right and left breasts. Thus, the proposed method can help with computer-aided detection for a more efficient DBT image analysis.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Algoritmos , Mama/patologia , Neoplasias da Mama/patologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Mamilos/diagnóstico por imagem , Reconhecimento Automatizado de Padrão , Reprodutibilidade dos Testes
4.
Healthc Inform Res ; 22(4): 293-298, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27895961

RESUMO

OBJECTIVES: We propose an automatic breast mass detection algorithm in three-dimensional (3D) ultrasound (US) images using the Hough transform technique. METHODS: One hundred twenty-five cropped images containing 68 benign and 60 malignant masses are acquired with clinical diagnosis by an experienced radiologist. The 3D US images are masked, subsampled, contrast-adjusted, and median-filtered as preprocessing steps before the Hough transform is used. Thereafter, we perform 3D Hough transform to detect spherical hyperplanes in 3D US breast image volumes, generate Hough spheres, and sort them in the order of votes. In order to reduce the number of the false positives in the breast mass detection algorithm, the Hough sphere with a mean or grey level value of the centroid higher than the mean of the 3D US image is excluded, and the remaining Hough sphere is converted into a circumscribing parallelepiped cube as breast mass lesion candidates. Finally, we examine whether or not the generated Hough cubes were overlapping each other geometrically, and the resulting Hough cubes are suggested as detected breast mass candidates. RESULTS: An automatic breast mass detection algorithm is applied with mass detection sensitivity of 96.1% at 0.84 false positives per case, quite comparable to the results in previous research, and we note that in the case of malignant breast mass detection, every malignant mass is detected with false positives per case at a rate of 0.62. CONCLUSIONS: The breast mass detection efficiency of our algorithm is assessed by performing a ROC analysis.

5.
Biomed Res Int ; 2016: 8651573, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27274993

RESUMO

We propose computer-aided detection (CADe) algorithm for microcalcification (MC) clusters in reconstructed digital breast tomosynthesis (DBT) images. The algorithm consists of prescreening, MC detection, clustering, and false-positive (FP) reduction steps. The DBT images containing the MC-like objects were enhanced by a multiscale Hessian-based three-dimensional (3D) objectness response function and a connected-component segmentation method was applied to extract the cluster seed objects as potential clustering centers of MCs. Secondly, a signal-to-noise ratio (SNR) enhanced image was also generated to detect the individual MC candidates and prescreen the MC-like objects. Each cluster seed candidate was prescreened by counting neighboring individual MC candidates nearby the cluster seed object according to several microcalcification clustering criteria. As a second step, we introduced bounding boxes for the accepted seed candidate, clustered all the overlapping cubes, and examined. After the FP reduction step, the average number of FPs per case was estimated to be 2.47 per DBT volume with a sensitivity of 83.3%.


Assuntos
Mama/patologia , Calcinose/diagnóstico , Imageamento Tridimensional/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos , Desenho Assistido por Computador , Feminino , Humanos , Mamografia/métodos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos
6.
Artigo em Inglês | MEDLINE | ID: mdl-23366341

RESUMO

Most countries face high and increasing rates of cardiovascular disease. Each year, heart disease kills more Americans than cancer. Therefore, there has been a promising market for portable ECG equipment and it is increasing. To use portable ECG measuring devices, it is essential to define a suitable location for the measuring as we need to reduced electrode size and distance. This research proposes to study how the inter-electrode distance affects the signal and how the electrode pair should be placed on the chest in order to obtain a sufficiently reliable ECG signal to detect heart arrhythmias in any environment, such as home or work. Therefore, we developed a compact, portable patch type ambulatory ECG monitoring system, Heart Tracker, using a microprocessor for preliminary study of signal analysis. To optimize the electrode arrangement in wireless environment, we compared HT and standard 12 lead with changing electrode position.


Assuntos
Algoritmos , Diagnóstico por Computador/instrumentação , Eletrocardiografia Ambulatorial/instrumentação , Eletrodos , Processamento de Sinais Assistido por Computador/instrumentação , Telemetria/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Artigo em Inglês | MEDLINE | ID: mdl-23367071

RESUMO

We suggest a sequential algorithm for the detection of the ventricular fibrillation (VF) and ventricular tachycardia (VT) of a rate above 180 bpm, so called shockable rhythms. The built-in algorithm for ECG analysis embedded in the portable bio-signal sensing module is aimed to discriminate between shockable and non-shockable rhythms and its accuracy is analyzed. An algorithm for VF/VT detection is proposed to analyze every 1 s ECG episode using the past 8 s episodes. The method is tested with 844,587 ECG episodes from the widely accepted databases. A sensitivity of 86.8 % and a specificity of 99.4 % were obtained and compared with the previous results.


Assuntos
Algoritmos , Diagnóstico por Computador/métodos , Eletrocardiografia/métodos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/prevenção & controle , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/prevenção & controle , Cardioversão Elétrica , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Artigo em Inglês | MEDLINE | ID: mdl-19162696

RESUMO

Osteoporosis is characterized by an abnormal loss of bone mineral content, which leads to a tendency to non-traumatic bone fractures or to structural deformations of bone. Thus, bone density has been considered as a most reliable parameter to assess osteoporotic fracture risk. In past decades, by the way, bone texture measures have been studied to estimate other aspect of bone quality. Some studies have been performed on CT or MR images to assess bone quality using trabecular structure analysis. Other studies have been performed on plain x-ray images or ultrasound images to assess trabecular structure. However, most of the studies are focused on individual parameters to distinguish between osteoporotic fractured group and nonfractured group. In this preliminary study, we combine various texture parameters with bone density parameters using a support vector machine and point out the most promising combination of parameters to distinguish between osteoporotic fractured group and nonfractured group.


Assuntos
Inteligência Artificial , Fraturas Ósseas/diagnóstico por imagem , Fraturas Espontâneas/diagnóstico por imagem , Osteoporose/diagnóstico por imagem , Reconhecimento Automatizado de Padrão/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Traumatismos do Punho/diagnóstico por imagem , Absorciometria de Fóton/métodos , Idoso , Diagnóstico Diferencial , Feminino , Fraturas Ósseas/etiologia , Fraturas Espontâneas/etiologia , Humanos , Osteoporose/complicações , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Traumatismos do Punho/etiologia
9.
Artigo em Inglês | MEDLINE | ID: mdl-18003265

RESUMO

Osteoporosis is characterized by an abnormal loss of bone mineral content, which leads to a tendency to non-traumatic bone fractures or to structural deformations of bone. Thus, bone density measurement has been considered as a most reliable method to assess bone fracture risk due to osteoporosis. In past decades, x-ray images have been studied in connection with the bone mineral density estimation. However, the estimated bone mineral density from the x-ray image can undergo a relatively large accuracy or precision error. The most relevant origin of the accuracy or precision error may be unstable x-ray image acquisition condition. In the previous study, we presented a bone mineral density estimation method that uses the trabecular bone filling factor in the radius x-ray image and that is relatively insensitive to the x-ray image acquisition condition. In this paper, we investigate the method using larger patient data and point out a preliminary result related to the fracture risk prediction using the method.


Assuntos
Absorciometria de Fóton/métodos , Densidade Óssea , Osteoporose/diagnóstico por imagem , Osteoporose/fisiopatologia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/fisiopatologia , Feminino , Humanos , Reprodutibilidade dos Testes , Medição de Risco/métodos , Fatores de Risco , Sensibilidade e Especificidade
10.
Artigo em Inglês | MEDLINE | ID: mdl-18002212

RESUMO

Various statistical parameters have been tried for the computer-aided diagnosis of the liver fibrosis. The region of interest (ROI) for the liver and spleen parenchymas have been chosen, and the hepatolienal textural contrast for each ultrasound (US) image has been examined. The selectively chosen textural parameters are linearly combined with the pre-determined coefficients to give the computer-aided diagnostic parameter for the liver fibrosis, whose final stage is named as cirrhosis. From the comparison with the clinical diagnosis it is suggested that the proposed calculation scheme using the textural parameters show the quite promising classification performance for the computer-aided diagnosis of the liver cirrhosis.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Cirrose Hepática/diagnóstico por imagem , Reconhecimento Automatizado de Padrão/métodos , Ultrassonografia/métodos , Inteligência Artificial , Humanos , Aumento da Imagem/métodos , Cirrose Hepática/complicações , Cirrose Hepática/etiologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Conf Proc IEEE Eng Med Biol Soc ; 2006: 1870-2, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17945678

RESUMO

Tinnitus is defined as an unwanted auditory perception of internal origin, usually localized, and rarely heard by others. Persisting appearances of tinnitus are most commonly combined with diseases or damage in the inner ear or neuro-auditory pathway. Diffusion tensor magnetic resonance imaging (DTI) is a new imaging method with the capability of providing non-invasive information on tissue microstructure not available in routine clinical MRI images. Since white matter regions of the brain are an ordered structure due to the myelination and directionality of axons and have a high degree of anisotropy, the ability to detect changes in anisotropy can be extremely useful in the study of diseases such as tinnitus and multiple sclerosis, which are assumed to involve the demyelination of axons. While several studies investigated tinnitus using MRI, few studies tried to analyze neurological disorders quantitatively using DTI. In this study, the cerebral volume of white matter on DTI images of patients with tinnitus was measured using the semi-automated and intuitive menu based image processing tool (Human Analyzer, ETRI, Korea). Total number of ten patients with tinnitus including three women was examined.


Assuntos
Encéfalo/patologia , Doenças Desmielinizantes/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Fibras Nervosas Mielinizadas/patologia , Zumbido/patologia , Adulto , Algoritmos , Doenças Desmielinizantes/etiologia , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Zumbido/complicações
12.
Conf Proc IEEE Eng Med Biol Soc ; 2006: 1983-5, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17945689

RESUMO

The detection of abnormal lesions in the early stages of lung cancer is important to improve survival. Computer-aided detection (CAD) system can be useful for early detection of pulmonary nodules on computed tomography (CT) images for screening. Moreover, CAD system can be 'second opinion' when a radiologist detects the pulmonary nodules on multi-slice CT images. We developed a computer-aided detection system for pulmonary nodule detection on multi-detector row computed tomography (MDCT) images. We applied the nodule isolation technique using radial distribution function and additional algorithms. In this paper, we reported the ground-glass opacity (GGO) lesions detected by self-developed computer-aided pulmonary nodule detection system.


Assuntos
Algoritmos , Reconhecimento Automatizado de Padrão/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Inteligência Artificial , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/instrumentação
13.
Conf Proc IEEE Eng Med Biol Soc ; 2006: 1980-2, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17945688

RESUMO

Osteoporosis is characterized by an abnormal loss of bone mineral content, which leads to a tendency to non-traumatic bone fractures or to structural deformations of bone. Thus, bone density measurement has been considered as a most reliable method to assess bone fracture risk due to osteoporosis. In past decades, X-ray images have been studied in connection with the bone mineral density estimation. However, the estimated bone mineral density from the X-ray image can undergo a relatively large accuracy or precision error. The most relevant origin of the accuracy or precision error may be unstable X-ray image acquisition condition. Thus, we focus our attentions on finding a bone mineral density estimation method that is relatively insensitive to the X-ray image acquisition condition. In this paper, we develop a simple technique for distal radius bone mineral density estimation using the trabecular bone filling factor in the X-ray image and apply the technique to the wrist X-ray images of 20 women. Estimated bone mineral density shows a high linear correlation with a dual-energy X-ray absorptiometry (r=0.87).


Assuntos
Absorciometria de Fóton/métodos , Densidade Óssea , Osteoporose/diagnóstico por imagem , Osteoporose/fisiopatologia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tíbia/diagnóstico por imagem , Tíbia/fisiopatologia , Algoritmos , Feminino , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Conf Proc IEEE Eng Med Biol Soc ; 2005: 3261-3, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-17282941

RESUMO

Osteoporosis is characterized by an abnormal loss of bone mineral content, which leads to a tendency to nontraumatic bone fractures or to structural deformations of bone. Thus bone density measurement has been considered as a most reliable method to assess bone fracture risk due to osteoporosis. In past decades bone texture measures have been also studied in connection with the bone quality estimation. However, most studies have been focused on texture analysis of CT or MR images. Though studies on plain radiographs have been also performed to assess in vivo trabecular structure these studies are mainly done on anatomic sites such as femur, spine, and calcaneus. In this preliminary study we apply various texture measures to distal radius plain radiographs and point out several promising texture measures that significantly distinguish between osteoporotic fractured group and nonfractured group.

15.
Conf Proc IEEE Eng Med Biol Soc ; 2005: 3348-50, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-17282963

RESUMO

We investigated the B-mode ultrasound (US) images of abdomen by normalizing the gray level values of the liver with the representative gray levels (RGL's) of the liver parenchyma, renal cortex, subcutaneous fat, to quantify the fatty infiltration of the liver (FIL). The RGL's were compared with the clinical diagnosis of the FIL showing good correlation between them.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...