Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Heart Rhythm ; 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38971417

RESUMO

BACKGROUND: Idiopathic epicardial premature ventricular contractions (PVCs) originating from the left ventricular summit are difficult to eliminate. OBJECTIVE: To describe feasibility and procedural safety of focal monopolar biphasic pulsed field ablation (F-PFA) from within the great cardiac vein (GCV) for the treatment of idiopathic epicardial PVCs. METHODS: In 4 pigs, F-PFA (CENTAURI, Cardiofocus) was applied from within the GCV followed by macroscopic gross analysis. In 4 patients with previously failed radiofrequency ablation, electroanatomic mapping was used to guide F-PFA from within the GCV and the ventricular outflow tracts. Coronary angiography and optical coherence tomography (OCT) were performed in 2 patients. RESULTS: In pigs, F-PFA from within the GCV (5mm away from the coronary arteries) resulted in myocardial lesions with a maximal depth of 4mm which was associated with non-obstructive transient coronary spasms. In patients, sequential delivery of F-PFA in the ventricular outflow tracts and from within the GCV eliminated the PVCs. During F-PFA delivery from within the GCV with prophylactic nitroglycerin application, coronary angiography showed no coronary spasm when F-PFA was delivered >5mm away from the coronary artery and a transient coronary spasm without changes in a subsequent OCT, when F-PFA was delivered directly on the coronary artery. Intracardiac echo and computer tomography integration was used to monitor F-PFA delivery from within the GCV. There were no immediate or short-term complications. CONCLUSION: Sequential mapping-guided F-PFA from endocardial ventricular outflow tracts and from within the GCV is feasible with a favourable procedural safety profile for the treatment of epicardial PVC.

2.
Europace ; 26(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38758963

RESUMO

AIMS: Pulmonary vein isolation (PVI) is the corner stone of modern rhythm control strategies in patients with atrial fibrillation (AF). Sleep-disordered breathing (SDB) is prevalent in more than 50% of patients undergoing AF ablation, and studies have indicated a greater recurrence rate after PVI in patients with SDB. Herein, we study the effect of catheter-based PVI on AF in a pig model for SDB. METHODS AND RESULTS: In 11 sedated spontaneously breathing pigs, obstructive apnoeas were simulated by 75 s of intermittent negative upper airway pressure (INAP) applied by a negative pressure device connected to the endotracheal tube. Intermittent negative upper airway pressures were performed before and after PVI. AF-inducibility and atrial effective refractory periods (aERPs) were determined before and during INAP by programmed atrial stimulation. Pulmonary vein isolation prolonged the aERP by 48 ± 27 ms in the right atrium (RA) (P < 0.0001) and by 40 ± 34 ms in the left atrium (LA) (P = 0.0004). Following PVI, AF-inducibility dropped from 28 ± 26% to 0% (P = 0.0009). Intermittent negative upper airway pressure was associated with a transient aERP-shortening (ΔaERP) in both atria, which was not prevented by PVI (INAP indued ΔaERP after PVI in the RA: -57 ± 34 ms, P = 0.0002; in the LA: -42 ± 24 ms, P < 0.0001). Intermittent negative upper airway pressure was associated with a transient increase in AF-inducibility (from 28 ± 26% to 69 ± 21%; P = 0.0008), which was not attenuated by PVI [INAP-associated AF-inducibility after PVI: 58 ± 33% (P = 0.5)]. CONCLUSION: Transient atrial arrhythmogenic changes related to acute obstructive respiratory events are not prevented by electrical isolation of the pulmonary veins, which partially explains the increased AF recurrence in patients with SDB after PVI procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Modelos Animais de Doenças , Veias Pulmonares , Animais , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/prevenção & controle , Fibrilação Atrial/diagnóstico , Suínos , Ablação por Cateter/métodos , Apneia Obstrutiva do Sono/fisiopatologia , Falha de Tratamento , Frequência Cardíaca , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia
3.
Heart Rhythm ; 21(5): 622-629, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38280622

RESUMO

BACKGROUND: More than 50% of patients with atrial fibrillation (AF) suffer from sleep disordered breathing (SDB). Obstructive respiratory events contribute to a transient, vagally mediated atrial arrhythmogenic substrate, which is resistant to most available antiarrhythmic drugs. OBJECTIVE: The purpose of this study was to investigate the effect of pharmacologic inhibition of the G-protein-gated acetylcholine-regulated potassium current (IK,ACh) with and without acute autonomic nervous system activation by nicotine in a pig model for obstructive respiratory events. METHODS: In 21 pigs, SDB was simulated by applying an intermittent negative upper airway pressure (INAP). AF inducibility and atrial effective refractory periods (aERPs) were determined before and during INAP by an S1S2 atrial pacing-protocol. Pigs were randomized into 3 groups-group 1: vehicle (n = 4); group 2: XAF-1407 (IK,ACh inhibitor) (n = 7); and group 3: nicotine followed by XAF-1407 (n = 10). RESULTS: In group 1, INAP shortened aERP (ΔaERP -42.6 ms; P = .004) and transiently increased AF inducibility from 0% to 31%. In group 2, XAF-1407 prolonged aERP by 25.2 ms (P = .005) during normal breathing and prevented INAP-induced aERP shortening (ΔaERP -3.6 ms; P = .3) and AF inducibility. In group 3, INAP transiently shortened aERP during nicotine perfusion (ΔaERP -33.6 ms; P = .004) and increased AF inducibility up to 61%, which both were prevented by XAF-1407. CONCLUSION: Simulated obstructive respiratory events transiently shorten aERP and increase AF inducibility, which can be prevented by the IK,ACh-inhibitor XAF-1407. XAF-1407 also prevents these arrhythmogenic changes induced by obstructive respiratory events during nicotine perfusion. Whether IK,ACh channels represent a target for SDB-related AF in humans warrants further study.


Assuntos
Fibrilação Atrial , Modelos Animais de Doenças , Animais , Suínos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/etiologia , Fibrilação Atrial/prevenção & controle , Átrios do Coração/fisiopatologia , Átrios do Coração/efeitos dos fármacos , Átrios do Coração/metabolismo , Acetilcolina/farmacologia , Nicotina/farmacologia , Síndromes da Apneia do Sono/fisiopatologia , Síndromes da Apneia do Sono/complicações
4.
Front Cardiovasc Med ; 10: 1139364, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36970354

RESUMO

Aim: To propose a standardized workflow for 3D-electroanatomical mapping guided pulmonary vein isolation in pigs. Materials and methods: Danish female landrace pigs were anaesthetized. Ultrasound-guided puncture of both femoral veins was performed and arterial access for blood pressure measurement established. Fluoroscopy- and intracardiac ultrasound-guided passage of the patent foramen ovale or transseptal puncture was performed. Then, 3D-electroanatomical mapping of the left atrium was conducted using a high-density mapping catheter. After mapping all pulmonary veins, an irrigated radiofrequency ablation catheter was used to perform ostial ablation to achieve electrical pulmonary vein isolation. Entrance- and exit-block were confirmed and re-assessed after a 20-min waiting period. Lastly, animals were sacrificed to perform left atrial anatomical gross examination. Results: We present data from 11 consecutive pigs undergoing pulmonary vein isolation. Passage of the fossa ovalis or transseptal puncture was uneventful and successful in all animals. Within the inferior pulmonary trunk 2-4 individual veins as well as 1-2 additional left and right pulmonary veins could be cannulated. Electrical isolation by point-by-point ablation of all targeted veins was successful. However, pitfalls including phrenic nerve capture during ablation, ventricular arrhythmias during antral isolation close to the mitral valve annulus and difficulties in accessing right pulmonary veins were encountered. Conclusion: Fluoroscopy- and intracardiac ultrasound-guided transseptal puncture, high-density electroanatomical mapping of all pulmonary veins and complete electrical pulmonary vein isolation can be achieved reproducibly and safely in pigs when using current technologies and a step-by-step approach.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...