Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Pulm Med ; 22(1): 211, 2022 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-35643452

RESUMO

BACKGROUND: There is increasing evidence of small airway abnormalities in smokers despite normal spirometry. The concavity in the descending limb of the maximum expiratory flow curve (MEFV) is a recognised feature of obstruction and can provide information beyond FEV1, and potentially early smoking-related damage. We aimed to evaluate concavity measures compared to known small airway measurements. METHODS: Eighty smokers with normal spirometry had small airway function assessed: multiple breath nitrogen washout (MBNW) from which ventilation heterogeneity in the diffusion-dependent acinar (Sacin) and convection-dependent conductive (Scond) airways were assessed, and impulse oscillometry system (IOS) from which respiratory resistance and reactance at 5 Hz (R5 and X5) were measured. Concavity measures were calculated from the MEFV, partitioned into global and peripheral concavity. RESULTS: We found abnormal peripheral and global concavity as well as acinar ventilation heterogeneity are common in "normal" smokers. Concavity measures were not related to either MBNW or IOS measurements. CONCLUSION: Abnormalities in concavity indices and MBNW or oscillometry parameters are common in smokers despite normal spirometry. However, these measures likely reflect different mechanisms of peripheral airway dysfunction.


Assuntos
Pulmão , Fumantes , Humanos , Oscilometria , Pirina , Testes de Função Respiratória , Espirometria
2.
ERJ Open Res ; 7(4)2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34761000

RESUMO

INTRODUCTION: We aimed to determine normal thresholds for positive bronchodilator responses for oscillometry in an Australian general population sample aged ≥40 years, to guide clinical interpretation. We also examined relationships between bronchodilator responses and respiratory symptoms, asthma diagnosis, smoking and baseline lung function. METHODS: Subjects recruited from Sydney, Melbourne and Busselton, Australia, underwent measurements of spirometry, resistance (R rs6 ) and reactance (X rs6 ) at 6 Hz, before and after inhalation of salbutamol 200 µg. Respiratory symptoms and/or medication use, asthma diagnosis, and smoking were recorded. Threshold bronchodilator responses were defined as the fifth percentile of decrease in R rs6 and 95th percentile increase in X rs6 in a healthy subgroup. RESULTS: Of 1318 participants, 1145 (570 female) were analysed. The lower threshold for ΔR rs6 was -1.38 cmH2O·s·L-1 (-30.0% or -1.42 Z-scores) and upper threshold for ΔX rs6 was 0.57 cmH2O·s·L-1 (1.36 Z-scores). Respiratory symptoms and/or medication use, asthma diagnosis, and smoking all predicted bronchodilator response, as did baseline oscillometry and spirometry. When categorised into clinically relevant groups according to those predictors, ΔX rs6 was more sensitive than spirometry in smokers without current asthma or chronic obstructive pulmonary disease (COPD), ∼20% having a positive response. Using absolute or Z-score change provided similar prevalences of responsiveness, except in COPD, in which responsiveness measured by absolute change was twice that for Z-score. DISCUSSION: This study describes normative thresholds for bronchodilator responses in oscillometry parameters, including intra-breath parameters, as determined by absolute, relative and Z-score changes. Positive bronchodilator response by oscillometry correlated with clinical factors and baseline function, which may inform the clinical interpretation of oscillometry.

3.
Respirology ; 25(6): 613-619, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31482693

RESUMO

BACKGROUND AND OBJECTIVE: Fixed airflow obstruction (FAO) in asthma occurs despite optimal inhaled treatment and no smoking history, and remains a significant problem, particularly with increasing age and duration of asthma. Increased lung compliance and loss of lung elastic recoil has been observed in older people with asthma, but their link to FAO has not been established. We determined the relationship between abnormal lung elasticity and airflow obstruction in asthma. METHODS: Non-smoking asthmatic subjects aged >40 years, treated with 2 months of high-dose inhaled corticosteroid/long-acting beta-agonist (ICS/LABA), had FAO measured by spirometry, and respiratory system resistance at 5 Hz (Rrs5 ) and respiratory system reactance at 5 Hz (Xrs5 ) measured by forced oscillation technique. Lung compliance (K) and elastic recoil (B/A) were calculated from pressure-volume curves measured by an oesophageal balloon. Linear correlations between K and B/A, and forced expiratory volume in 1 s/forced vital capacity (FEV1 /FVC), Rrs5 and Xrs5 were assessed. RESULTS: Eighteen subjects (11 males; mean ± SD age: 64 ± 8 years, asthma duration: 39 ± 22 years) had moderate FAO measured by spirometry ((mean ± SD z-score) post-bronchodilator FEV1 : -2.2 ± 0.5, FVC: -0.7 ± 1.0, FEV1 /FVC: -2.6 ± 0.7) and by increased Rrs5 (median (IQR) z-score) 2.7 (1.9 to 3.2) and decreased Xrs5 : -4.1(-2.4 to -7.3). Lung compliance (K) was increased in 9 of 18 subjects and lung elastic recoil (B/A) reduced in 5 of 18 subjects. FEV1 /FVC correlated negatively with K (rs = -0.60, P = 0.008) and Rrs5 correlated negatively with B/A (rs = -0.52, P = 0.026), independent of age. Xrs5 did not correlate with lung elasticity indices. CONCLUSION: Increased lung compliance and loss of elastic recoil relate to airflow obstruction in older non-smoking asthmatic subjects, independent of ageing. Thus, structural lung tissue changes may contribute to persistent, steroid-resistant airflow obstruction. CLINICAL TRIAL REGISTRATION: ACTRN126150000985583 at anzctr.org.au (UTN: U1111-1156-2795).


Assuntos
Corticosteroides/uso terapêutico , Asma/tratamento farmacológico , Volume Expiratório Forçado/fisiologia , Complacência Pulmonar/fisiologia , Capacidade Vital/fisiologia , Idoso , Asma/patologia , Elasticidade/efeitos dos fármacos , Feminino , Humanos , Pulmão/patologia , Masculino , Pessoa de Meia-Idade , Doença Pulmonar Obstrutiva Crônica , Testes de Função Respiratória/métodos , Espirometria/métodos
4.
J Appl Physiol (1985) ; 126(5): 1223-1231, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-30763164

RESUMO

Respiratory system reactance (Xrs) measured by the forced oscillation technique (FOT) is theoretically and experimentally related to lung volume. In chronic obstructive pulmonary disease (COPD), the absolute volume measured by body plethysmography includes a proportion that is inaccessible to pressure oscillations applied via the mouth, that is, a "noncommunicating" lung volume. We hypothesized that in COPD the presence of noncommunicating lung would disrupt the expected Xrs-volume relationship compared with plethysmographic functional residual capacity (FRCpleth). Instead, Xrs would relate to estimates of communicating volume, namely, expiratory reserve volume (ERV) and single-breath alveolar volume (VaSB). We examined FOT and lung function data from people with COPD (n = 51) and from healthy volunteers (n = 40). In healthy volunteers, we observed an expected inverse relationship between reactance at 5 Hz (X5) and FRCpleth. In contrast, there was no such relationship between X5 and FRCpleth in COPD subjects. However, there was an inverse relationship between X5 and both ERV and VaSB. Hence the theoretical Xrs-volume relationship is present in COPD but only when considering the communicating volume rather than the absolute lung volume. These findings confirm the role of reduced communicating lung volume as an important determinant of Xrs and therefore advance our understanding and interpretation of FOT measurements in COPD. NEW & NOTEWORTHY To investigate the determinants of respiratory system reactance (Xrs) measured by the forced oscillation technique (FOT) in chronic obstructive pulmonary disease (COPD), we examine the relationship between Xrs and lung volume. We show that Xrs does not relate to absolute lung volume (functional residual capacity) in COPD but instead relates only to the volume of lung in communication with the airway opening. This communicating volume may therefore be fundamental to our interpretation of FOT measurements in COPD and other pulmonary diseases.


Assuntos
Volume Expiratório Forçado/fisiologia , Pulmão/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Volume de Ventilação Pulmonar/fisiologia , Adulto , Idoso , Resistência das Vias Respiratórias/fisiologia , Feminino , Capacidade Residual Funcional/fisiologia , Humanos , Masculino , Oscilometria/métodos , Espirometria/métodos , Capacidade Vital/fisiologia
6.
J Clin Monit Comput ; 32(3): 509-512, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28761996

RESUMO

The forced oscillation technique (FOT) is an emerging clinical lung function test, with commercial devices becoming increasingly available. However comparability across existing devices has not been established. We evaluated in vivo and in vitro measurements made using three commercial devices against a custom-built device (WIMR): Resmon Pro Diary (Restech srl, Italy), tremoFlo C-100 (Thorasys Medical Systems, Canada), Jaeger Masterscope CT IOS (CareFusion, Hoechberg, Germany). Respiratory system resistance Rrs and reactance Xrs at 5 Hz were examined in twelve healthy subjects (mean age 33 ± 11 years, 7 males), and in two test standards of known resistance and reactance. Subjects performed three measurements during tidal breathing on the four devices in random order. Total, inspiratory and expiratory Rrs and Xrs were calculated and compared using one-way repeated measures ANOVA and Bonferroni post-hoc tests. Rrs did not differ between devices, with <10% deviation from predicted, except for the IOS device. With Xrs, similar values were seen between the WIMR and Resmon devices and between the tremoFlo and IOS devices. No differences were observed using test standards; deviation from theoretical value was <2% for resistance and <5% for reactance. The WIMR, tremoFlo and Resmon Pro but not IOS devices measure similar Rrs, whereas there was more disparity across devices in the estimation of Xrs parameters. The discrepancy between in vivo and in vitro measurements suggest that FOT validation procedures need to take into account the breathing pattern, either using biological controls or a breathing model.


Assuntos
Desenho de Equipamento , Oscilometria/métodos , Testes de Função Respiratória/instrumentação , Testes de Função Respiratória/métodos , Adulto , Feminino , Voluntários Saudáveis , Humanos , Técnicas In Vitro , Masculino , Monitorização Fisiológica , Reprodutibilidade dos Testes , Respiração , Processamento de Sinais Assistido por Computador , Software , Adulto Jovem
7.
Respirology ; 23(5): 512-518, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29141272

RESUMO

BACKGROUND AND OBJECTIVE: Smokers develop respiratory symptoms and peripheral airway dysfunction even when spirometry is preserved. Multiple breath nitrogen washout (MBNW) and impulse oscillometry system (IOS) are potentially useful measures of peripheral airway function but they have not been compared in such subjects. We hypothesized that MBNW and IOS are jointly abnormal in smokers with normal spirometry and that these abnormalities relate to respiratory symptoms. METHODS: Eighty smokers with normal spirometry completed a symptom questionnaire, had ventilation heterogeneity in diffusion (Sacin) and convection-dependent (Scond) airways and trapped gas volume at functional residual capacity as a percentage of vital capacity (%VtrFRC/VC) measured by MBNW. Respiratory resistance and reactance at 5 and 20 Hz were measured using IOS. RESULTS: Respiratory symptoms were reported in 55 (68%) subjects. Forty (50%) subjects had at least one abnormal MBNW parameter, predominantly in Sacin. Forty-one (51%) subjects had at least one abnormal IOS parameter, predominantly in resistance. Sixty-one (76%) subjects had an abnormality in either MBNW or IOS. Chronic bronchitis symptoms were associated with an increased Scond, while wheeze was associated with lower spirometry and an increased resistance. Abnormalities in MBNW and IOS parameters were unrelated to each other. CONCLUSIONS: Respiratory symptoms and peripheral airway dysfunction are common in smokers with normal spirometry. Symptoms of chronic bronchitis related to conductive airway abnormalities, while wheeze was related to spirometry and IOS. The clinical significance of abnormalities in peripheral airway function in smokers remains undetermined.


Assuntos
Bronquite Crônica/fisiopatologia , Pulmão/fisiopatologia , Fumar/fisiopatologia , Adulto , Resistência das Vias Respiratórias , Feminino , Capacidade Residual Funcional , Humanos , Masculino , Oscilometria , Estudos Prospectivos , Capacidade de Difusão Pulmonar , Sons Respiratórios , Espirometria , Inquéritos e Questionários , Avaliação de Sintomas , Volume de Ventilação Pulmonar
8.
Respirology ; 21(7): 1270-6, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27140677

RESUMO

BACKGROUND AND OBJECTIVE: Cigarette smoke exposure increases airway smooth muscle (ASM) contractility. Abnormalities in peripheral airway function in smokers with normal spirometry could be due to the effects of ASM tone. We aimed to determine the contribution of ASM tone to peripheral airway function in smokers with normal spirometry from the response to bronchodilator (BD). METHODS: Ventilation heterogeneity in peripheral conductive (Scond) and acinar (Sacin) airways were measured in 50 asymptomatic smokers and 20 never-smokers using multiple breath nitrogen washout, before and 20 min after inhalation of 200 µg salbutamol and 80 µg ipratropium bromide. Z-scores were calculated to define abnormality in Sacin and Scond. RESULTS: Nineteen smokers had abnormal Sacin, and 12 had abnormal Scond; 7 had abnormalities in both. After BD, Sacin improved in smokers with normal Sacin (6.5 ± 15.9%, P = 0.02), smokers with abnormal Sacin (9.2 ± 16.9%, P = 0.03) and in control subjects (11.7 ± 18.2%, P = 0.01), with no differences in improvements between groups. Sacin remained abnormal in 15/19 smokers and their post-BD values correlated with smoking exposure (r = 0.53, P = 0.02). After BD, Scond improved in smokers with abnormal Scond (28.3 ± 15.9%, P = 0.002) and normalized in 9/12 subjects, but not in those with normal Scond (0.25 ± 32.7%, P = 0.44) or control subjects (-1.7 ± 21.2%, P = 0.64). CONCLUSION: In smokers with normal spirometry, abnormal conductive airway function could be attributed to increased bronchomotor tone. In contrast, bronchomotor tone in acinar airways is unaffected by smoking and functional abnormality. There may be different causal mechanisms underlying acinar and conductive airway abnormalities in smokers with normal spirometry.


Assuntos
Albuterol/farmacologia , Broncodilatadores/farmacologia , Ipratrópio/farmacologia , Músculo Liso/efeitos dos fármacos , Respiração/efeitos dos fármacos , Fumar , Adulto , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Espirometria , Adulto Jovem
9.
Artigo em Inglês | MEDLINE | ID: mdl-25999709

RESUMO

BACKGROUND: Expiratory flow limitation (EFL) is seen in some patients presenting with a COPD exacerbation; however, it is unclear how EFL relates to the clinical features of the exacerbation. We hypothesized that EFL when present contributes to symptoms and duration of recovery during a COPD exacerbation. Our aim was to compare changes in EFL with symptoms in subjects with and without flow-limited breathing admitted for a COPD exacerbation. SUBJECTS AND METHODS: A total of 29 subjects with COPD were recruited within 48 hours of admission to West China Hospital for an acute exacerbation. Daily measurements of post-bronchodilator spirometry, resistance, and reactance using the forced oscillation technique and symptom (Borg) scores until discharge were made. Flow-limited breathing was defined as the difference between inspiratory and expiratory respiratory system reactance (EFL index) greater than 2.8 cmH2O·s·L(-1). The physiological predictors of symptoms during recovery were determined by mixed-effect analysis. RESULTS: Nine subjects (31%) had flow-limited breathing on admission despite similar spirometry compared to subjects without flow-limited breathing. Spirometry and resistance measures did not change between enrolment and discharge. EFL index values improved in subjects with flow-limited breathing on admission, with resolution in four patients. In subjects with flow-limited breathing on admission, symptoms were related to inspiratory resistance and EFL index values. In subjects without flow-limited breathing, symptoms related to forced expiratory volume in 1 second/forced vital capacity. In the whole cohort, EFL index values at admission was related to duration of stay (Rs=0.4, P=0.03). CONCLUSION: The presence of flow-limited breathing as well as abnormal respiratory system mechanics contribute independently to symptoms during COPD exacerbations.


Assuntos
Expiração , Pulmão/fisiopatologia , Admissão do Paciente , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Idoso , Resistência das Vias Respiratórias , Broncodilatadores/uso terapêutico , China , Progressão da Doença , Expiração/efeitos dos fármacos , Feminino , Volume Expiratório Forçado , Humanos , Inalação , Pulmão/efeitos dos fármacos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doença Pulmonar Obstrutiva Crônica/complicações , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Recuperação de Função Fisiológica , Espirometria , Fatores de Tempo , Resultado do Tratamento , Capacidade Vital
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...