Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Orthop Surg Res ; 18(1): 433, 2023 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-37312224

RESUMO

BACKGROUND: The present study aimed to evaluate the indications, feasibility, clinical effectiveness and complications of the treatment with microwave in situ inactivation followed by curettage and bone grafting assisted with internal fixation, for the proximal humerus tumors. METHODS: The clinical data of 49 patients with primary or metastatic tumor of the proximal humerus who received intraoperative microwave inactivation in situ with curettage and bone grafting in our hospital from May 2008 to April 2021 were retrospectively analyzed. RESULTS: There were 25 males and 24 females, with an average age of 57.6 ± 19.9 years (range, 20-81). All patients were followed up for 7 to 146 months, with an average period of 69.2 ± 39.8 months. Up to the last follow-up, 14 patients died. The 5-year overall survival was 67.3%, and 5-year tumor-specific survival was 71.4%. The 5-year tumor-specific survival rates were 100% for aggressive benign tumors or low potential malignancy tumors, 70.1% for primary malignancies, and 36.9% for metastatic tumors. The average preoperative MSTS, constant-Murley and VAS scores were 16.81 ± 3.85, 62.71 ± 12.56 and 6.75 ± 2.47, which were all significantly improved at 6 weeks after operation and at the final follow-up (P < 0.05). CONCLUSIONS: Microwave inactivation in situ and curettage and bone grafting are a feasible treatment for tumors of proximal humeral, especially for malignant tumors and metastases, without the necessity of the replacement of the shoulder, with little trauma and good upper limb function, and with low local recurrence and distant metastasis.


Assuntos
Hipertermia Induzida , Neoplasias , Feminino , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Ombro , Micro-Ondas/uso terapêutico , Estudos Retrospectivos , Úmero/cirurgia
2.
Cell Tissue Bank ; 24(4): 747-758, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37133795

RESUMO

Decalcified bone matrix (DBM) is a widely used alternative material for bone transplantation. In the DBM production process, an effective particle size and the highest utilization rate of raw materials can be achieved only through multiple high-speed circulating comminution. The rat posterolateral lumbar fusion model (PLF) is the most mature small animal model for the initial evaluation of the efficacy of graft materials for bone regeneration and spinal fusion. To evaluate the differences in the in vivo osteogenic effects of DBM pulverization through 1, 5, 9, and 14 high-speed cycles, sixty athymic rats were divided into six groups: single cycling crushing (CC1), 5 cycles of crushing (CC5), 9 cycles of crushing (CC9), 13 cycles of crushing (CC13), autogenous bone graft (ABG) and negative control (NC). Posterolateral lumbar fusion was performed. Six weeks after surgery, the bilateral lumbar fusion of athymic rats was evaluated through manual palpation, X-ray, micro-CT and histological sections. Rank data were tested by the rank-sum test, and nonparametric data were tested by the Kruskal‒Wallis H test. The manual palpation and X-ray results showed that the fusion rate did not significantly differ between the CC1, CC5, CC9, CC13 and ABG groups. However, cavities appeared in CC9 and CC13 on the micro-CT image. The bone mass (BV/TV) of CC1, CC5, CC9 and CC13 was better than that of the ABG group, while almost no osteogenesis was observed in the NC group. Histologically, there was no obvious difference between the four groups except that the CC9 group and CC13 group had more fibrous tissues in the new bone. In conclusion, DMB with different cycling crushing times has no obvious difference in fusion rate of PLF, but it is slightly better than the ABG group.


Assuntos
Matriz Óssea , Fusão Vertebral , Ratos , Animais , Matriz Óssea/transplante , Ratos Nus , Vértebras Lombares/cirurgia , Osso e Ossos , Fusão Vertebral/métodos , Transplante Ósseo/métodos
3.
Cell Tissue Bank ; 2023 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-36797536

RESUMO

The purpose of this study was to investigate whether 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) combined with n-hydroxysuccinimide (NHS) can repair tendon damage caused by peracetic acid-ethanol and gamma irradiation sterilization. The semitendinosus tendons of 15 New Zealand white rabbits were selected as experimental materials, and the tendons were sterilized in a solution containing 1% (v/w) peracetic acid and 24% (v/w) ethanol. After 15 kGy gamma irradiation sterilization, the tendons were randomly divided into three groups (n = 10). The tendons were repaired with EDCs of 0, 2.5 and 5 mM combined with 5 mM NHS for 6 h, the tendons were temporarily stored at - 80 ± °C. The arrangement and spatial structure of collagen fibers were observed by light microscopy and scanning electron microscopy, the collagen type and collagen crimp period were observed under a polarizing microscope, and the collagen fibril diameter and its distribution were measured by transmission electron microscopy, from which the collagen fibril index and mass average diameter were calculated. The resistance of collagen to enzymolysis was detected by the free hydroxyproline test, and tensile fracture and cyclic loading tests of each group of tendons were carried out, from which the elastic modulus, maximum stress, maximum strain, strain energy density and cyclic creep strain were calculated. The obtained results showed that the gap between loose collagen fibers in the 0 mM control group was wider, the parallel arrangement of tendons in the 2.5 and 5 mM groups was more uniform and regular and the fiber space decreased, the crimp period in the 5 mM group was lower than that in the 0 mM group (P < 0.05), and the concentration of hydroxyproline in the 5 mM group (711.64 ± 77.95 µg/g) was better than that in the control group (1150.57 ± 158.75 µg/g). The elastic modulus of the 5 mM group (424.73 ± 150.96 MPa) was better than that of the 0 mM group (179.09 ± 37.14 MPa). Our results show that EDC combined with NHS can repair damaged tendons after peracetic acid-ethanol and gamma radiation treatment, and 5 mM EDC has better morphological performance, anti-enzymolysis ability and biomechanical properties than 2.5 mM EDC.

4.
Cell Tissue Bank ; 24(1): 203-210, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35831637

RESUMO

At present, the commonly used allogeneic bone powder in the clinic can be divided into nondemineralized bone matrix and demineralized bone matrix (DBM). Commonly used demineralizers include acids and ethylene diamine tetraacetic acid (EDTA). There may be some diversities between them. Also, the size of the bone particle can affects its cell compatibility and osteogenic ability. We produced different particle sizes i.e., < 75, 75-100, 100-315, 315-450, 450-650, and 650-1000 µm, and treated in three ways (nondemineralized, demineralized by EDTA, and demineralized by HCl). Scanning electron microscopy showed that the surface of the samples in each group was relatively smooth without obvious differences. The results of specific surface area and porosity analysis showed that they were significantly higher in demineralized bone powder than in nondemineralized bone powder, however, there was no significant difference between the two decalcification methods. The content of hydroxyproline in nondemineralized bone powder and EDTA-demineralized bone powder had no statistical difference, while HCl-demineralization had statistical significance compared with the former two, and the content increased with the decrease of particle size. The protein and BMP-2 extracted from HCl demineralized bone powder were significantly higher than that from nondemineralized bone powder and EDTA demineralized bone powder, and there were differences among different particle sizes. These results suggested the importance of demineralization mode and particle size of the allogenic bone powder and provided guidance for the choice of the most appropriate particle size and demineralization mode to be used in tissue bioengineering.


Assuntos
Osso e Ossos , Transplante de Células-Tronco Hematopoéticas , Tamanho da Partícula , Pós/análise , Ácido Edético , Matriz Óssea/química , Osteogênese , Técnica de Desmineralização Óssea
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...