1.
Ultrasonics ; 142: 107355, 2024 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-38830325

RESUMO

Fatigue crack is one of the main failure modes of pressure vessels. Online monitoring and predicting methods of crack growth play an important role in the operation of important pressure vessel. The SH0 wave is non-dispersive, and it is not disturbed by internal media of pressure vessel and very sensitive to cracks, therefore it is suitable for fatigue crack growth monitoring. Moreover, fatigue crack growth in industry is affected by material properties, loads, which usually shows some uncertainty. And the particle filter (PF) is well suited to deal with prediction problems affected by uncertainty. Hence, the prediction method of crack growth based on SH0 wave monitoring and PF is proposed (short for SH0-PF). The basic theory of crack monitoring method using SH0 wave is introduced, and the signal feature extraction using the damage index is studied. The state equation characterizing the fatigue crack growth is established by Paris model, and the observation equation is established based on the normalized correlation moment damage index according to monitoring signal using SH0 wave. The prediction reliability of the fatigue crack growth applying SH0-PF is verified by experiment with the single edge notched specimen. The experimental results indicate that the prediction accuracy of SH0-PF is better than that of the traditional Paris model.

2.
Ultrasonics ; 108: 106236, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32866941

RESUMO

Dry-coupled ultrasonic waveguide transducers enable the long-term monitoring of the critical mechanical components working in high temperature environment. In these systems, waveguide units are applied to isolate the vulnerable piezoelectric elements from the harsh measurement zones. However, the disturbance cannot be overcome, which may arise from inevitably temperature fluctuation and the indirect measurement in long term monitoring. In the present research, a high temperature experimental system using dry-coupled ultrasonic waveguide transducers is investigated. The disturbances caused by this measurement system are studied in the heating period, holding period and cooling period, respectively. Moreover, the correlations between the group velocities, dispersion curves, signal amplitudes, waveforms under temperature variations are investigated. At last, the dispersion characteristics of the shear horizontal wave in high temperature stainless steel plate are analyzed. This work strives to pave a solid foundation for the application of SH waves to online monitoring of high-temperature equipment using dry-coupled ultrasonic waveguide transducers.

3.
Sensors (Basel) ; 20(7)2020 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-32235338

RESUMO

For the purpose of providing transducers for long-term monitoring of wall thinning of critical pressure equipment in corrosion or high temperature environments, the optimal design methodology for tapered waveguide units was proposed in the present study. Firstly, the feasibility of the quasi-fundamental shear horizontal (SH0*) wave propagating in the tapered waveguide units was analyzed via numerical simulations, and the transmitting limitations of the non-dispersive SH0* wave were researched. Secondly, several tapered waveguide transducers with varying cross-sections to transmit pure SH0* wave were designed according to the numerical results. Experimental investigations were carried out, and the results were compared with waveguide transducers with a prismatic cross-section. It was found that the tapered waveguide units can transmit non-dispersive shear horizontal waves and suppress the wave attenuation at the same time. The experimental results agreed very well with the numerical simulations. Finally, high-temperature experiments were carried out, and the reliability of thickness measuring by the tapered waveguide transducers was validated. The errors between the measured and the true thicknesses were small. This work paves a solid foundation for the optimal design of tapered waveguide transducers for thickness monitoring of equipment in harsh environments.

4.
Sensors (Basel) ; 19(4)2019 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-30781384

RESUMO

The safety of critical pressure equipment in elevated temperature is increasingly important. Moreover, the on-line monitoring method is potentially useful to improve their safety. A waveguide bar system can enable monitoring of critical equipment working in elevated temperature using reliable ultrasonic technology. Among the waveguide bar system, the matching mechanism of the transducer and the waveguide bar is crucial to propagate the pure fundamental quasi-shear mode (shorten for SH0*) wave. In the present research, the loading line sources that can excite pure SH0* wave are investigated and the anti-plane shear loading source is selected. The critical values about the geometric dimensions of the junctions between the piezoelectric transducer and the waveguide bar are explored by simulation and experiments. On the condition that the excitation sources satisfy the critical values, the loading can be approximated to an anti-plane shear one to excite the pure SH0* wave. Some waveguide bar systems are designed based on the simulated critical values and some experiments at high temperature are carried out. The experimental results verify that the designed waveguide bar systems can excite the pure SH0* wave at elevated temperatures, which verify the reliability of the simulated critical results.

5.
Materials (Basel) ; 10(9)2017 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-28869554

RESUMO

Guided wave technique could be a possible method for monitoring components working in high temperature above 350 °C. However, this would require the design of an appropriate waveguide bar to transmit the wave, so that its sensing part is not influenced by the high temperature. In the present study, the shape of waveguide bars is designed based on the analysis of wave source characteristics. The critical frequency-width and frequency-thickness products of waveguide bars are analyzed theoretically and numerically to transmit the zeroth shear horizontal wave SH0* in bars. The results show that waveguide bars can cut off all the other wave modes when their frequency-thickness products are smaller than the critical value fd*, and frequency-width products are not smaller than the critical value fw*. Six waveguide bars are designed and fabricated based on the design criteria, and an experiment system is set up to check their work performance. The testing results indicate that the wave signals of the SH0* mode propagate clearly in waveguide bars, and cut off all the other modes when the frequency-thickness products and frequency-width products of the bars meet the design criteria. It is also demonstrated that the dependency of the experimental group velocity of each waveguide bar on frequency is in good agreement with the numerical result. High-temperature experiments also validate the reliability of the designed waveguide bars. Therefore, the critical frequency-thickness product and frequency-width product can be the basis for the design of the waveguide bars.

6.
Sensors (Basel) ; 13(11): 15504-12, 2013 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-24233026

RESUMO

To accurately detect deformation and extend the component life beyond the original design limits, structural safety monitoring techniques have attracted considerable attention in the power and process industries for decades. In this paper an on-line monitoring system for high temperature pipes in a power plant is developed. The extension-based sensing devices are amounted on straight pipes, T-Joints and elbows of a main steam pipeline. During on-site monitoring for more than two years, most of the sensors worked reliably and steadily. However, the direct strain gauge could not work for long periods because of the high temperature environment. Moreover, it is found that the installation and connection of the extensometers can have a significant influence on the measurement results. The on-line monitoring system has a good alarming function which is demonstrated by detecting a steam leakage of the header.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...