Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ann Anat ; 256: 152313, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39097117

RESUMO

BACKGROUND: To prevent the absorption and collapse of the labial bone plate of the anterior teeth, immediate implantation and socket shield technique have been increasingly applied to anterior dental aesthetic implant restoration. OBJECTIVE: To provide a biomechanical basis for implant restoration of maxillary anterior teeth, finite element analysis was used to investigate the stress peak and distribution in different anatomical sites of natural teeth, conventional immediate implantation and socket shield technique. METHODS: Three maxillary finite element models were established, including a maxillary incisor as a natural tooth, a conventional immediate implantation and a socket shield technique. A mechanical load of 100 N was applied to simulate and analyze the biomechanical behavior of the root, periodontal ligament (PDL), implant and surrounding bone interface. RESULTS: The stress distribution of the natural tooth was relatively uniform under load. The maximum von Mises stress of the root, periodontal ligament, cortical bone and cancellous bone were 20.14 MPa, 2.473 MPa, 19.48 MPa and 5.068 MPa, respectively. When the conventional immediate implantation was loaded, the stress was mainly concentrated around the neck of implant. Maximum stress on the surface of the implant was 102 MPa, the cortical bone was 16.13 MPa, and the cancellous bone was 18.29 MPa. When the implantation with socket shield technique was loaded, the stress distribution of the implant was similar to that of immediate implantation. Maximum stress on the surface of the implant was 100.5 MPa, the cortical bone was 23.11 MPa, the cancellous bone was 21.66 MPa, the remaining tooth fragment was 29.42 MPa and the periodontal ligament of the tooth fragment was 1.131 MPa. CONCLUSIONS: 1. Under static loading, both socket shield technology and conventional immediate implantation can support the esthetic restoration of anterior teeth biomechanically. 2.Under short-term follow-up, both immediate implant and socket shield technology achieved satisfactory clinical results, including bone healing and patient satisfaction. 3.The stress distribution is mainly located on the buccal bone surface of the implant and is associated with resorption of the buccal bone plate after implant replacement in both socket shield technology and conventional immediate implantation. 4.The presence of retained root fragment had an impact on the bone graft gap. In immediate implantation, the peak stress was located in the cortical bone near the implant position, while in socket shield technology, the peak stress was at the neck of the cortical bone corresponding to the retained root fragment.


Assuntos
Análise de Elementos Finitos , Incisivo , Maxila , Ligamento Periodontal , Alvéolo Dental , Humanos , Incisivo/anatomia & histologia , Incisivo/fisiologia , Maxila/fisiologia , Maxila/cirurgia , Alvéolo Dental/cirurgia , Alvéolo Dental/fisiologia , Fenômenos Biomecânicos , Ligamento Periodontal/fisiologia , Estresse Mecânico , Raiz Dentária/anatomia & histologia , Raiz Dentária/fisiologia , Masculino , Implantes Dentários , Carga Imediata em Implante Dentário/métodos
2.
J Prosthet Dent ; 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38782608

RESUMO

STATEMENT OF PROBLEM: Factors influencing early implant failure (failure during the healing period) in the rehabilitation and restoration of oral function in partially edentulous patients are unclear. PURPOSE: The purpose of this clinical study was to investigate several factors that may be associated with early implant failure. MATERIAL AND METHODS: This retrospective study was conducted on 3247 implants in 2061 patients between 2009 and 2022. Patient-related and surgery-related factors, including smoking; sex; diabetes; bone grafting; implant length, diameter, and design; adjacent teeth; and insertion torque, were manually retrieved and analyzed. Using univariate and multivariate analyses, a generalized estimating equation (GEE) model with chi-squared tests was employed to evaluate factors related to early implant failure (the failure before restoration) (α=.05). RESULTS: The mean ±standard deviation age of the study patients was 49.2 ±15.0 years (range 18 to 91). Ninety-nine implants (3.05%) failed during the healing period. Three factors were statistically significant regarding early implant failure: smoking (odds ratio [OR]=1.92, P=.008), implant design (tapered implants) (OR=1.84, P=.007), and implant length <10 mm (OR=2.98, P=.011). Factors including diabetes, bone grafting, anatomic location, adjacent teeth (endodontic therapy in the adjacent teeth and the distance between implant and adjacent teeth), healing method, and insertion torque did not exhibit a statistically significant higher early implant failure rate. Ninety-three sites with failed implants received new implants, and 6 of these 93 implants failed during the healing period. CONCLUSIONS: Within the limitation of sample size, smokers, implant length (<10 mm), and implant design (tapered implant) exhibited higher risk of early implant failure in this retrospective study. Implant insertion torque, healing method, adjacent teeth, and diabetes did not significantly influence the risk of early implant failure.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA