Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Front Cardiovasc Med ; 10: 1281860, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38028455

RESUMO

Background: Ultrasound-guided percutaneous device closure of perimembranous ventricular septal defects (PmVSD) is a minimally invasive recent treatment approach. Perventricular PmVSD device closure is an emerging radiation-free intervention, yet it comes with certain limitations. No studies compared both of these treatment approaches. Methods: We performed a retrospective institutional data comparison of percutaneous (PCP Group, n = 138) and perventricular (PVP Group, n = 67) ultrasound-guided device closure procedures in 205 patients with PmVSD between March 2017 and December 2022. Results: Patients of the PCP and PVP groups had a median age of 4.9 years (IQR, 3.1-14.0) and 5.3 years (IQR, 3.4-13.1) respectively. The median PmVSD diameter in the PCP Group was 4.0 mm (IQR, 3.3-5.3) and 5.2 mm (IQR, 4.0-7.0) in the PVP Group (p = 0.001). There was no significant difference in success rates between the PCP and PVP Groups (intention-to-treat population, 88.4% vs. 92.5%, p = 0.36; as-treated population, 88.4% vs. 89.3%, p = 0.84). 5/8 failed percutaneous cases that were shifted to the perventricular approach were successful. Compared to the PVP Group, patients of the PCP group experienced a significant decrease in ventilation time, drainage volume, and postoperative hospital stay (p < 0.001). The median follow-up period was 24 months (IQR, 6-42) for the PCP group and 61 months (IQR, 53-65) for the PVP group. The overall severe adverse event rate was 0% in the PCP group and 3.0% in the PVP group. Conclusions: Perventricular and percutaneous ultrasound-guided device closure of PmVSD are both effective and safe treatment options. The percutaneous approach offers less trauma and faster recovery and may be the preferred approach in selected patients.

2.
Cardiol Young ; 32(4): 589-596, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34247666

RESUMO

BACKGROUND: The safe closure of atrial septal defect with deficient posterior-inferior or inferior vena cava rim is a controversial issue. Few studies have been conducted on the closure of atrial septal defect with deficient posterior-inferior or inferior vena cava rim without fluoroscopy. This study evaluated the feasibility and safety of echocardiography-guided transcatheter closure of atrial septal defect with deficient posterior-inferior or inferior vena cava rim. METHODS: The data of 136 patients who underwent transcatheter atrial septal defect closure without fluoroscopy from March 2017 to March 2020 were retrospectively analysed. The patients were classified into the deficient (n = 45) and sufficient (n = 91) posterior-inferior or inferior vena cava rim groups. Procedure and the follow-up results were compared between the two groups. RESULTS: Atrial septal defect indexed diameter and the device indexed diameter in the deficient rim group were both larger than that in the sufficient rim group (22.12 versus 17.38 mm/m2, p < 0.001; 24.77 versus 21.21 mm/m2, p = 0.003, respectively). There was no significant difference in the success rate of occlusion between two groups (97.78% in the deficient rim group versus 98.90% in the sufficient rim group, p = 1.000). During follow-up, the incidence of severe adverse cardiac events was not statistically significant (p = 0.551). CONCLUSIONS: Atrial septal defect with deficient posterior-inferior or inferior vena cava rim can safely undergo transcatheter closure under echocardiography alone if precisely evaluated with transesophageal or transthoracic echocardiography and the size of the occluder is appropriate. The mid-term results after closure are similar to that for an atrial septal defect with sufficient rim.


Assuntos
Comunicação Interatrial , Dispositivo para Oclusão Septal , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia , Ecocardiografia Transesofagiana , Estudos de Viabilidade , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/cirurgia , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/cirurgia
3.
Chinese Pharmacological Bulletin ; (12): 153-158, 2022.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1014186

RESUMO

Aim To study the modulation effects of HKSX capsule on Alzheimer's disease (AD) and to preliminarily explore its mechanism using SAMP8 as an AD model.Methods SAMP8 mice aged 4 months were randomly divided into model group ( P8 group) , HKSX low-dose group (L-HKSX group) , HKSX high- dose group ( H-HKSX group) , and senescence-accel- erated mouse/resistance 1 (SAMR1 ) at the same age was used as normal control group ( R1 group).New object recognition and Morris water maze experiments were used to detect the learning and memory abilities of each group.Levels of A(3, _40 and A(3, 42 were detected by ELISA, and the expression levels of LC3- U , p62, Beclin-1 , PSD95 and Syn in hippocampus of each group were detected by Western blot.Results Compared with model group, both low and high doses of HKSX could enhance the D1 in new object recognition test, increase number of crossing the platform anrl the time spent in the target quadrant, and shorten the escape latency.Besides, it also enhanced the clearance °f Ap, _40 and AfJ, _42 , up-regulated the relative expression of Beclin-1 and LC3- II and down-regulated the expression of P62.In addition, it increased the expression of synaptic-related proteins PSD95 and Syn.Conclusions HKSX capsule can regulate the expression of autophagy-related proteins and improve autoph- agv dysfunction, which in turn reduce the deposition of A(3 in vivo to alleviate its cytotoxicity and improve synaptic plasticity.Thus, HKSX can improve the learning and memory deficits of AD mice.

4.
Medicine (Baltimore) ; 96(36): e7968, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28885350

RESUMO

BACKGROUND: Left ventricular (LV) remodeling after myocardial injury, volume or pressure overload is characterized by a change in LV shape from an ellipse to more of a sphere. The usefulness of 3-dimensional (3D) sphericity index (SpI) for accurate evaluation of LV remodeling remains uncertain despite extensive research. METHODS: We searched Pubmed, Embase, Web of Science, and Cochrane databases to identify relevant studies from January 1, 1990 to August 1, 2016. The quality of each study was evaluated using the Newcastle-Ottawa Scale. Meta regression and sensitivity and subgroup analyses based on patterns of LV remodeling were performed. RESULTS: Thirteen studies with a total of 1064 patients were included in this meta-analysis. There was evidence of obvious heterogeneity (I = 82.4%; P < .001), which was mainly accounted for by the pattern of remodeling according to meta-regression. The result of subgroup meta-analyses suggested that SpI in patients with eccentric remodeling was significantly higher compared with control group (95% confidence interval [CI], 0.78-1.10). No statistic difference was found in LV SpI between healthy controls and patients with concentric hypertrophy (95% CI, -0.89 to 0.16) or myocardial injury (95% CI, -0.13 to 0.41). CONCLUSION: 3D SpI can be widely used to assess LV remodeling in patients with eccentric remodeling, but has limitations in predicting concentric hypertrophy and regional or chronic myocardial injury.


Assuntos
Cardiopatias/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Imageamento Tridimensional , Remodelação Ventricular , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...