1.
Trials ; 22(1): 123, 2021 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-33557898

RESUMO

BACKGROUND: Neck pain is a common clinical disease, which seriously affects people's mental health and quality of life and results in loss of social productivity. Improving neck pain's curative effect and reducing its recurrence rate are major medical problems. Shi's manipulation therapy has unique advantages and technical features that aid in the diagnosis and treatment of neck pain. Compared with first-line non-steroidal anti-inflammatory drug (NSAID) treatment of neck pain, Shi's cervical manipulation lacks the relevant research basis of therapeutic advantage, safety, and satisfaction for treating acute and subacute neck pain. Herein, we aim to confirm our hypothesis in a clinical trial that the safety and efficacy of Shi's cervical manipulation will be more effective, safer, and more satisfactory than NSAIDs to treat acute and subacute neck pain. METHODS: In this multicenter, positive-controlled, randomized clinical trial, traditional analgesic drug (NSAID) is used to evaluate and show that Shi's manipulation is more effective, safe, and satisfactory for treating acute and subacute neck pain. Overall, 240 subjects are randomly divided into the trial and control groups, with both groups treated by the corresponding main intervention method for up to 12 weeks. Clinical data will be collected before the intervention and immediately after the first treatment; at 3 days and 1, 2, 4, 8, and 12 weeks after the intervention; and at 26 and 52 weeks after treatment follow-up of clinical observation index data collection. The clinical observation indices are as follows: (1) cervical pain is the primary observation index, measured by Numerical Rating Scale. The secondary indices include the following: (2) cervical dysfunction index, measured by patient self-evaluation using cervical Neck Disability Index; (3) cervical activity measurement, measured by the cervical vertebra mobility measurement program of Android mobile phone system; (4) overall improvement, measured by patient self-evaluation with SF-36; and (5) satisfactory treatment, determined by patient self-evaluation. DISCUSSION: We will discuss whether Shi's cervical manipulation has greater advantages in efficacy, safety, and satisfaction of acute and subacute neck pain than traditional NSAIDs, to provide a scientific basis for the dissemination and application of Shi's cervical manipulation. TRIAL REGISTRATION: China Registered Clinical Trial Registration Center ChiCTR1900021371 . Registered on 17 February 2019.


Assuntos
Manipulação da Coluna , Cervicalgia , China , Humanos , Manipulação da Coluna/efeitos adversos , Estudos Multicêntricos como Assunto , Cervicalgia/diagnóstico , Cervicalgia/terapia , Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
2.
Artigo em Inglês | MEDLINE | ID: mdl-30643532

RESUMO

OBJECTIVE: To compare the immediate and short term effectiveness of Shi's Daoyin therapy (DT) rather than the Melbourne Protocol (MP) in terms of pain, mobility, and isometric strength of cervical muscles in nonacute nonspecific neck pain patients. MATERIAL AND METHODS: A total of 114 nonacute nonspecific neck pain patients aged 20~50 years were recruited and randomly assigned to be treated by either Shi's DT or the MP. 56 cases and 54 cases received treatment for 3 weeks and were evaluated before and after intervention and at 3-week follow-up in Shi's DT group and MP group, respectively. The outcome measures were Chinese version of the Neck Disability Index (NDI), cervical range of motion (ROM), maximal voluntary isometric force (MVIF), and pain intensity (Numeric Pain Rating Scale, NPRS). RESULTS: All outcomes of both groups showed statistically significant improvements after the intervention and at 3-week follow-up (P < 0.05), while no statistically significant difference was found in NDI between groups. When followed up after 3 weeks, the ROM in axial rotation was significantly greater in the Shi's DT group (P < 0.05), and the NPRS in the Shi's DT group was significantly lower than the MP group (P < 0.05). At the end of the treatment period, the MVIF in lateral bending in the Shi's DT group had a lower value (P = 0.044) than in the MP group, but there was no significant difference in flexion and extension between the two groups. CONCLUSIONS: Both Shi's DT and MP groups demonstrated an obvious reduction in pain intensity and improvements in neck mobility after a short term follow-up period. The improvement of Shi's DT in disability and pain during functional activities is generally similar to that of the MP for the treatment of nonacute nonspecific neck pain.

3.
Int J Artif Organs ; 37(5): 392-401, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24619902

RESUMO

In this paper, a novel artificial anal sphincter (AAS) system based on rebuilding the rectal sensation function is proposed to treat human fecal incontinence. The executive mechanism of the traditional AAS system was redesigned and integrated for a simpler structure and better durability. The novel executive mechanism uses a sandwich structure to simulate the basic function of the natural human anal sphincter. To rebuild the lost rectal sensation function caused by fecal incontinence, we propose a novel method for rebuilding the rectal sensation function based on an Optimal Wavelet Packet Basis (OWPB) using the Davies-Bouldin (DB) index and a support vector machine (SVM). OWPB using a DB index is used for feature vector extraction, while a SVM is adopted for pattern recognition.Furthermore, an in vitro experiment with the AAS system based on rectal sensation function rebuilding was carried out. Experimental results indicate that the novel executive mechanism can simulate the basic function of the natural human anal sphincter, and the proposed method is quite effective for rebuilding rectal sensation in patients.


Assuntos
Canal Anal/fisiopatologia , Defecação/fisiologia , Incontinência Fecal/cirurgia , Desenho de Prótese , Sensação/fisiologia , Incontinência Fecal/fisiopatologia , Humanos , Técnicas In Vitro , Próteses e Implantes
4.
J Med Eng Technol ; 37(4): 307-12, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23706019

RESUMO

This paper presents a wireless, miniaturized, bi-directional telemetric artificial anal sphincter system that can be used for controlling patients' anal incontinence. The artificial anal sphincter system is mainly composed of an executive mechanism, a wireless power supply system and a wireless communication system. The wireless communication system consists of an internal RF transceiver, an internal RF antenna, a data transmission pathway, an external RF antenna and an external RF control transceiver. A micro NMHA (Normal Mode Helical Antenna) has been used for the transceiver of the internal wireless communication system and a quarter wave-length whip antenna of 7.75 cm has been used for the external wireless communication system. The RF carrier frequency of wireless communication is located in a license-free 433.1 MHz ISM (Industry, Science, and Medical) band. The radiation characteristics and SAR (Specific Absorption Rate) are evaluated using the finite difference time-domain method and 3D human body model. Results show that the SAR values of the antenna satisfy the ICNIRP (International Commission on Nonionizing Radiation Protection) limitations.


Assuntos
Canal Anal , Órgãos Artificiais , Tecnologia sem Fio/instrumentação , Algoritmos , Fenômenos Eletromagnéticos , Humanos , Modelos Biológicos
SELEÇÃO DE REFERÊNCIAS