Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Quant Imaging Med Surg ; 9(5): 905-920, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31281783

RESUMO

Endoscopic imaging is the main method for detecting gastrointestinal diseases, which adversely affect human health. White light endoscopy (WLE) was the first method used for endoscopic examination and is still the preliminary step in the detection of gastrointestinal diseases during clinical examination. However, it cannot accurately diagnose gastrointestinal diseases owing to its poor correlation with histopathological diagnosis. In recent years, many advanced endoscopic methods have emerged to improve the detection accuracy by endoscopy. Chromoendoscopy (CE) enhances the contrast between normal and diseased tissues using biocompatible dye agents. Narrow band imaging (NBI) can improve the contrast between capillaries and submucosal vessels by changing the light source acting on the tissue using special filters to realize the visualization of the vascular structure. Flexible spectral imaging color enhancement (FICE) technique uses the reflectance spectrum estimation technique to obtain individual spectral images and reconstructs an enhanced image of the mucosal surface using three selected spectral images. The i-Scan technology takes advantage of the different reflective properties of normal and diseased tissues to obtain images, and enhances image contrast through post-processing algorithms. These abovementioned methods can be used to detect gastrointestinal diseases by observing the macroscopic structure of the digestive tract mucosa, but the ability of early cancer detection is limited with low resolution. However, based on the principle of confocal imaging, probe-based confocal laser endomicroscopy (pCLE) can enable cellular visualization with high-performance probes, which can present cellular morphology that is highly consistent with that shown by biopsy to provide the possibility of early detection of cancer. Other endoscopic imaging techniques including endoscopic optical coherence tomography (EOCT) and photoacoustic endoscopy (PAE), are also promising for diagnosing gastrointestinal diseases. This review focuses on these technologies and aims to provide an overview of different technologies and their clinical applicability.

2.
Water Res ; 161: 297-307, 2019 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-31203035

RESUMO

This study evaluated the anti-biofouling efficacy of capacitor mode and resistor mode in membrane distillation (MD). Polytetrafluoroethylene (PTFE) membrane coated with carbon nanotube (CNT) was adopted as the electrically conductive membrane. The biofouling formation on the pre-treatment membrane was systematically analyzed, and the results showed that both operation modes had obvious inhabitation on bacteria, especially the capacitor mode exhibited stronger prevention capability on biomass accumulation than resistor mode. NMDs analysis of microbial communities further revealed that the anti-biofouling effect mainly occurred on the membrane surface, and gram-positive biomarkers which can survive better in external electric field was distinctively found in capacitor mode through LEfSE analysis. Hypothesis was introduced to explain the anti-fouling function of two modes that in the capacitor mode, the competitive electrostatic repulsion of bacteria cells on negative electrode associated by the cell-disruption effect of electro-catalyzed reactive oxygen species (ROS) generation, while the anti-fouling function of resistor mode was a result of temperature increment on membrane surface caused by Joule heating effects. This article attempts to provide an insight of anti-fouling mechanism of electric field applied in MD and to prove the feasibility of above-mentioned operation modes as non-chemical methods for optimization of membrane-based water treatment process.


Assuntos
Incrustação Biológica , Purificação da Água , Destilação , Condutividade Elétrica , Eletricidade , Membranas Artificiais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...