1.
JAMA Ophthalmol ; 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38935400

RESUMO

Importance: Capsular tension rings (CTRs) can support weak zonules and inhibit capsular shrinkage, thus potentially reducing intraocular lens (IOL) decentration and tilt. However, it has been debated whether CTRs can reduce IOL decentration and tilt in highly myopic eyes and whether CTR implantation is necessary for all highly myopic eyes. Objective: To evaluate the influence of CTR implantation on IOL decentration and tilt in highly myopic eyes. Design, Setting, and Participants: This randomized clinical trial was conducted between November 2021 and September 2023 at the Zhongshan Ophthalmic Center, Guangzhou, China. Patients with cataract and an axial length (AL) of 26 mm or longer were enrolled. Interventions: Participants were stratified into 3 groups based on the AL (stratum 1, 26 mm ≤ AL <28 mm; stratum 2, 28 mm ≤ AL <30mm; stratum 3, AL ≥30 mm), and further randomly assigned to the CTR group (a C-loop IOL combined with a CTR) or the control group (only a C-loop IOL) within each stratum. Main Outcomes and Measures: IOL decentration at 3 months after cataract surgery was evaluated using anterior segment optical coherence tomography. Results: A total of 186 eyes of 186 participants (mean [SD] age, 57.3 [10.9] years; 118 female [63.4%]) were randomized into the CTR group (93 [50%]) or control group (93 [50%]), with 87 eyes (93.6%) and 92 eyes (98.9%) completing follow-up at 3 months, respectively. The CTR group showed smaller IOL decentration (0.19 mm vs 0.23 mm; difference, -0.04 mm; 95% CI, -0.07 to -0.01 mm; P = .02) and tilt at 3 months, and lower proportions of clinically significant IOL decentration (≥0.4 mm) and tilt (≥7°) at 3 months compared with the control group. Similar results were only found in eyes with an AL of 30 mm or longer (IOL decentration: 0.20 mm vs 0.28 mm; difference, -0.08 mm; 95% CI, -0.14 to -0.02 mm; P = .01). Additionally, the CTR group showed a smaller change in IOL decentration from 1 week to 3 months, higher prediction accuracy, and better visual quality and patient satisfaction in this stratum. No differences were observed between the CTR and control groups in eyes with an AL less than 30 mm. Conclusions and Relevance: CTR implantation reduced C-loop IOL decentration and tilt, increased position stability, and improved visual quality in eyes with an AL of 30 mm or longer. These findings support use of CTR implantation in eyes with an AL of 30 mm or longer and implanted with C-loop IOLs. Trial Registration: ClinicalTrials.gov Identifier: NCT05161520.

2.
Am J Ophthalmol ; 262: 237-245, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38452920

RESUMO

PURPOSE: To investigate the relationship between effective lens position (ELP) and patient characteristics, and to further develop a new intraocular lens (IOL) calculation formula for cataract patients with previous pars plana vitrectomy (PPV). DESIGN: Cross-sectional study. METHODS: A total of 2793 age-related cataract patients (group 1) and 915 post-PPV cataract patients (group 2) who underwent phacoemulsification with IOL implantation were included. The ELP of 2 groups was compared and the association between ELP and patient characteristics was further evaluated using standardized multivariate regression coefficients. An ensemble artificial intelligence-based ELP prediction model was developed using a training set of 810 vitrectomized eyes, and a thick-lens IOL formula (LISA-PPV) was constructed and compared with 7 existing formulas on an external multi-center testing set of 105 eyes. RESULTS: Compared to eyes with age-related cataract, vitrectomized eyes showed a similar ELP distribution (P = .19), but different standardized coefficients of preoperative biometry for ELP. The standardized coefficients also varied with the type of vitreous tamponade, history of scleral buckling, and ciliary sulcus IOL implantation. The LISA-PPV formula showed the lowest mean and median absolute prediction error (MAE: 0.63 D; MedAE: 0.44 D), and the highest percentages of eyes within ±0.5 D of prediction error (57.14%) in the testing dataset. CONCLUSIONS: The ELP prediction required optimization specifically for vitrectomized eyes based on their biometric and surgical characteristics. The LISA-PPV formula is a useful and accurate tool for determining IOL power in cataract patients with previous PPV (available at http://ppv-iolcalculator.com/).


Assuntos
Inteligência Artificial , Biometria , Implante de Lente Intraocular , Lentes Intraoculares , Óptica e Fotônica , Facoemulsificação , Vitrectomia , Humanos , Estudos Transversais , Masculino , Feminino , Idoso , Vitrectomia/métodos , Biometria/métodos , Pessoa de Meia-Idade , Acuidade Visual/fisiologia , Idoso de 80 Anos ou mais , Refração Ocular/fisiologia , Catarata/fisiopatologia , Catarata/complicações , Estudos Retrospectivos
3.
Asia Pac J Ophthalmol (Phila) ; 13(1): 100001, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38383078

RESUMO

PURPOSE: To investigate the between-eye differences of the crystalline lens in subjects with unilateral high myopia and assess its contribution to the interocular refractive error disparity. METHODS: Children and adolescents with unilateral high myopia, defined as cycloplegic spherical equivalent (SE) ≤ -5D in one eye and ≥ -3D in the other eye, were recruited. Ocular biometric parameters, including axial length (AL) and lens thickness (LT), were measured by IOLMaster 700. Other lens-related parameters, including anterior lens radius of curvature (ALR) and posterior lens radius of curvature (PLR), were measured by CASIA2 swept-source optical coherence tomography. Lens power (LP) was calculated using Bennett's formula. Paired t-test was used to assess the between-eye difference in biometric parameters, and multiple regression analysis was used to assess factors associated with the between-eye SE difference. RESULTS: Ninety-one participants (6-18 years of age; 52.75% girls) were included. The highly myopic eyes showed significantly lower LP (P < 0.001) and smaller ALR (P < 0.001) than the contralateral eyes, while no significant difference was found in central LT. In both eyes, ALR was significantly related to SE (P = 0.001 and P = 0.006, respectively); while LT was not associated with SE (P = 0.051 and P = 0.052, respectively). Paired-eye analysis showed that the between-eye difference in ALR was the only lenticular parameter significantly associated with the between-eye difference in SE (P = 0.005). CONCLUSION: In highly myopic eyes, the crystalline lens reduced total power but morphologically changed to a more curved shape without significant lens thinning, suggesting that the LP loss is mainly achieved by reducing its internal power in high myopes.


Assuntos
Cristalino , Miopia , Erros de Refração , Criança , Feminino , Humanos , Adolescente , Masculino , Olho , Miopia/complicações , Refração Ocular , Erros de Refração/complicações , Comprimento Axial do Olho
4.
Graefes Arch Clin Exp Ophthalmol ; 262(6): 1829-1838, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38197993

RESUMO

PURPOSE: To investigate the effect of posterior keratometry (PK) on the accuracy of 10 intraocular lens (IOL) power calculation formulas using standard keratometry (K) and total keratometry (TK). METHODS: This is a retrospective consecutive case-series study. The IOL power was calculated using K and TK measured by IOLMaster 700 in 6 new-generation formulas (Barrett Universal II, Emmetropia Verifying Optical (EVO) 2.0, RBF Calculator 3.0, Hoffer QST, Kane, and Ladas Super Formula) and 4 traditional formulas (Haigis, Hoffer Q, Holladay 1, and SRK/T). The arithmetic prediction error (PE) and mean absolute PE (MAE) were evaluated. The locally-weighted scatterplot smoothing was performed to assess the relationship between PE and PK. RESULTS: A total of 576 patients (576 eyes) who underwent cataract surgery were included. Compared with using K, all formulas using TK showed a hyperopic shift in the whole group. Specifically, for eyes with PK exceeding -5.90 D, all formulas using TK exhibited a hyperopic shift (all P < 0.001), while eyes with PK less than -5.90 D showed a myopic shift (all P < 0.001). The MAE of new-generation formulas calculated with TK and K showed no statistical differences, while the MAE of traditional formulas with TK was larger (TK: 0.34 ~ 0.43 D; K: 0.33 ~ 0.42 D, all P < 0.05). CONCLUSIONS: The prediction bias of formulas with TK increased as PK deviated from -5.90 D. TK did not improve the prediction accuracy of new-generation formulas, and even performed worse in traditional formulas.


Assuntos
Biometria , Córnea , Lentes Intraoculares , Óptica e Fotônica , Refração Ocular , Humanos , Estudos Retrospectivos , Refração Ocular/fisiologia , Feminino , Masculino , Biometria/métodos , Idoso , Córnea/diagnóstico por imagem , Reprodutibilidade dos Testes , Pessoa de Meia-Idade , Acuidade Visual/fisiologia , Facoemulsificação/métodos , Idoso de 80 Anos ou mais , Seguimentos , Implante de Lente Intraocular/métodos
5.
Acta Ophthalmol ; 2024 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-38235601

RESUMO

PURPOSE: To determine whether correcting the axial length (AL) measurement error of the IOLMaster 700 could improve the refractive prediction accuracy in silicone oil-filled eyes. METHODS: This study included 265 cataract patients (265 eyes) with silicone oil tamponade who were scheduled for phacoemulsification with intraocular lens (IOL) implantation. The performances of various formulas, including Barrett Universal II, Emmetropia Verifying Optical, Hoffer-QST, Kane, Ladas Super Formula, Pearl-DGS, Radial Basis Function and traditional formulas (Haigis, Hoffer Q, Holladay 1 and SRK/T), were evaluated. The refractive prediction errors (PE) calculated with measured AL (ALmeas ) and corrected AL with silicone oil adjustment (SOAL ) were compared. Subgroup analysis was performed based on the ALmeas (<23 mm; 23-26 mm; ≥26 mm). RESULTS: Using SOAL significantly reduced the hyperopic PE of formulas when compared to ALmeas (-0.05 to 0.17 D vs 0.15 to 0.38 D, p < 0.001). After applying AL correction, all formulas showed a lower mean absolute PE (0.47-0.57 D vs 0.50-0.69 D). The percentage of eyes within ±1.0 D of PE increased from 84.91%-88.68% to 89.81%-91.32% for new formulas and from 78.11%-83.40% to 85.66%-88.68% for traditional formulas, with the use of SOAL . Subgroup analysis showed that the majority of formulas with SOAL in prediction accuracy for eyes with an AL ≥26 mm (p < 0.05). CONCLUSIONS: The refractive prediction accuracy in silicone oil-filled eyes was improved by correcting the AL measurement error of the IOLMaster 700, especially for long eyes.

6.
Transl Vis Sci Technol ; 12(3): 13, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36928129

RESUMO

Purpose: The purpose of this study was to compare total keratometry (TK) and posterior keratometry (PK) obtained by two swept-source optical biometers (IOLMaster 700 and CASIA2) and one Scheimpflug-based topography (Pentacam AXL). Methods: The TK and PK in cataract surgery candidates obtained by IOLMaster 700, CASIA2, and Pentacam AXL were compared. Intraclass correlation coefficients (ICCs), limit of agreement, and Bland-Altman plots were used to assess the agreement. Results: One hundred two patients with a mean age of 68.21 ± 8.70 years were included. There were significant differences among IOLMaster 700, CASIA2, and Pentacam AXL in the mean TK (TKm) (44.23 ± 1.59 diopters [D] vs. 43.25 ± 1.53 D vs. 43.94 ± 1.68 D; all P < 0.001), mean PK (PKm; -5.90 ± 0.24 D vs. -6.25 ± 0.25 D vs. -6.37 ± 0.26 D; all P < 0.001) and TK-J0 (-0.34 ± 0.65 D vs. -0.23 ± 0.53 D vs. -0.12 ± 0.62 D; all P < 0.001). We also observed significant differences in PK-J45 between IOLMaster 700 and Pentacam AXL as well as between CASIA2 and Pentacam AXL (both P < 0.001). There was a good agreement in TKm, TK-J0, TK-J45, and PK-J0 (ICC = 0.887, 0.880, 0.751, and 0.807, respectively), a moderate agreement in PK-J45 (ICC = 0.626), and a poor agreement in PKm (ICC = 0.498) among these 3 biometers. Conclusions: TK, PK, and the corresponding astigmatism obtained by IOLMaster 700, CASIA2, and Pentacam AXL showed significant differences, and could not be used interchangeably. Translational Relevance: Our study may help to guide preoperative keratometry measurement for intraocular lens (IOL) power calculation and astigmatism evaluation for patients with cataract.


Assuntos
Astigmatismo , Catarata , Humanos , Pessoa de Meia-Idade , Idoso , Biometria , Estudos Prospectivos , Córnea
7.
J Immunol Res ; 2022: 6008376, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35812246

RESUMO

Allergic asthma is associated with allergen-induced airway hyperresponsiveness and inflammatory cell infiltration. While moderate-to-severe asthma with refractory symptoms is difficult to treat, methane is protective against organ damage. In this study, an asthmatic mouse model was established. Airway resistance under acetylcholine stimulation in asthmatic mice and histology of lung tissue injury were determined. EOS infiltration was determined by flow cytometry. Enzyme-linked immunosorbent assays (ELISAs) were performed for the determination of relevant cytokine levels in asthmatic mice with or without methane treatment. The potential mechanisms of methane under anti-IL-10 antibody intraperitoneal intervention were assessed by ELISA and flow cytometry. Pulmonary T regulatory cells (Tregs) were analyzed by flow cytometry, and anti-CD25 antibody was used to block them. Immunoblot analysis was performed to evaluate if methane played a role in the asthmatic lungs via the NF-κB and MAPKs pathways. The results showed that methane significantly improved airway compliance, relieved asthma-induced lung injury, and reduced EOS accumulation and inflammatory mediators in the lungs of ovalbumin-treated asthmatic mice. Anti-IL-10 treatment diminished the ameliorating effect of methane on asthma. In addition, methane enhanced pulmonary Tregs in asthma, which could be blocked by the anti-CD25 antibody. Further analysis revealed that methane decreased p-p65/p65 and p-p38/p38 expression. In conclusion, methane is a readily available and inexpensive molecule potentially suitable for human use, which can alleviate asthma-induced lung injury and EOS infiltration through the IL-10 pathway by increasing Tregs and decreasing NF-κB and p38 MAPK in a mouse model.


Assuntos
Asma , Lesão Pulmonar , Animais , Líquido da Lavagem Broncoalveolar , Modelos Animais de Doenças , Pulmão/patologia , Lesão Pulmonar/tratamento farmacológico , Lesão Pulmonar/metabolismo , Lesão Pulmonar/patologia , Metano/metabolismo , Metano/farmacologia , Camundongos , Camundongos Endogâmicos BALB C , NF-kappa B/metabolismo , Ovalbumina
8.
Front Cell Dev Biol ; 10: 794837, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35531093

RESUMO

Congenital hereditary cataract is genetically heterogeneous and the leading cause of visual impairment in children. Identification of hereditary causes is critical to genetic counselling and family planning. Here, we examined a four-generation Chinese pedigree with congenital dominant cataract and identified a new mutation in GJA8 via targeted exome sequencing. A heterozygous missense mutation c.263C > T, leading to a proline-to-Leucine conversion at the conserved residue 88 in the second transmembrane domain of human connexin 50 (Cx50), was identified in all patients but not in unaffected family members. Functional analyses of the mutation revealed that it disrupted the stability of Cx50 and had a deleterious effect on protein function. Indeed, the mutation compromised normal membrane permeability and gating of ions, and impeded cell migration when overexpressed. Together, our results expand the pathogenic mutation spectrum of Cx50 underlying congenital cataract and lend more support to clinical diagnosis and genetic counseling.

9.
Curr Eye Res ; 45(4): 483-489, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31566446

RESUMO

Purpose: To identify the pathogenetic mutations in a four-generation Chinese family with dominant congenital cataracts and microphthalmia.Methods: A four-generation Chinese family with dominant congenital cataracts were recruited. Genomic DNAs were collected from their peripheral blood leukocytes and subjected to whole exome sequencing. The genetic mutations were identified by bioinformatic analyses and verified by Sanger sequencing.Results: Whole exome sequencing revealed a c.279C>G point mutation in the CRYBB1 gene which was further verified by Sanger sequencing. The nucleotide replacement results in a novel mutation p.S93R in a conserved residue of ßB1 crystallin which is predicted to disrupt normal ßB1 structure and function.Conclusions: We identified a novel missense mutation p.S93R in CRYBB1 in a Chinese family with autosomal dominant congenital cataracts and microphthalmia. This serine residue is extremely conserved evolutionarily in more than 50 ßγ-crystallins of many species. These data will be very helpful to further understand the structural and functional features of crystallins.