1.
Biomicrofluidics ; 12(1): 014111, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29464009

RESUMO

Self-monitoring of glycated albumin (GA), a useful glycemic marker, is an established method for preventing diabetes complications. Here, the paper-based lateral flow assay devices were developed for the sensitive detection of GA and the total human serum albumin (tHSA) in self-monitoring diabetes patients. Boronic acid-derived agarose beads were packed into a hole on a lateral flow channel. These well-coordinated agarose beads were used to capture GA through specific cis-diol interactions and to enhance the colorimetric signals by concentrating the target molecules. The devices exhibited large dynamic ranges (from 10 µg/ml to 10 mg/ml for GA and from 10 mg/ml to 50 mg/ml for tHSA) and low detection limits (7.1 µg/ml for GA and 4.7 mg/ml for tHSA), which cover the range of GA concentration in healthy plasma, which is 0.21-1.65 mg/ml (0.6%-3%). In determining the unknown GA concentrations in two commercial human plasma samples, the relative percentage difference between the values found by a standard ELISA kit and those found by our developed devices was 2.62% and 8.80%, which are within an acceptable range. The measurements of GA and tHSA were completed within 20 min for the total sample-to-answer diagnosis, fulfilling the demand for rapid analysis. Furthermore, the recovery values ranged from 99.4% to 110% in device accuracy tests. These results indicate that the developed paper-based device with boronic acid-derived agarose beads is a promising platform for GA and tHSA detection as applied to self-monitoring systems.

2.
Anal Sci ; 33(9): 993-998, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28890500

RESUMO

In the present study, we developed an electrochemical sensor for highly sensitive detection of hydroxylamine using Au-Pt alloy nanoparticles. Au-Pt alloy nanoparticles were electrochemically deposited on a working electrode made of single-walled carbon nanotubes. The framework composition in the Au-Pt alloy nanoparticle was easily controlled by adjusting the Au3+:Pt4+ composition ratio in the precursor solution. Morphological and chemical characterizations of the resulting Au-Pt alloy nanoparticles were performed using field emission scanning electron microscopy, X-ray diffraction, and energy dispersion X-ray spectroscopy. When the Au3+:Pt4+ ratio in the precursor solution was 1:5, the ratio of Au:Pt atom in alloy nanoparticle was about 6:4. Au60Pt40 alloy nanoparticles were found to have the optimum synthetic ratio for hydroxylamine detection. The electrocatalytic performance of Au-Pt alloy nanoparticles in the presence of hydroxylamine was also characterized using cyclic voltammetry, differential pulse voltammetry, and chronoamperometry. In the chronoamperometric detection of hydroxylamine, the sensor exhibited a detection limit of 0.80 µM (S/N = 3) and a high sensitivity of 184 µA mM-1 cm-2. Moreover, the amperometric response of the sensor in 1 mM hydroxylamine was stable for a long time (450 s). Long-term stability tests showed that the current responses to hydroxylamine were 96, 91 and 85% of the initial signal value after storage for 5, 10, and 20 days, respectively.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...