Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Neuroradiol ; 51(1): 74-81, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37442272

RESUMO

PURPOSE: Traditional flow diverters (FDs) for treating aneurysms at the fetal posterior communicating artery are unsatisfactory. Surpass Streamline is a novel FD with different mesh characteristics; however, the outcomes for such aneurysms remain unclear. This study aimed to compare hemodynamic alterations induced by Surpass Streamline, Pipeline Flex, and Tubridge devices and explore possible strategies for aneurysms at the fetal posterior communicating artery. METHODS: Two simulated aneurysms (Case 1, Case 2) were constructed from digital subtraction angiography (DSA). The three FDs were virtually deployed, and hemodynamic analysis based on computational fluid dynamics was performed. Hemodynamic parameters, including the sac-averaged velocity magnitude (Velocity), high-flow volume (HFV), and wall shear stress (WSS), were compared between each FD and the untreated model (control). Surpass Streamline was performed in real life for two aneurysms and the clinical outcomes were collected for analysis. RESULTS: Compared to the control, the Surpass resulted in the most significant reduction in flow. In Case 1, the Velocity, HFV, and WSS were reduced by 51.6%, 78.1%, and 64.3%, respectively. In Case 2, the Velocity, HFV, and WSS were reduced by 48.0%, 81.1%, and 65.3%, respectively. Tubridge showed slightly larger changes in hemodynamic parameters than Pipeline. In addition, our analysis suggested that metal coverage was correlated with the WSS, Velocity, and HFV. The postoperative DSA showed that the aneurysm was nearly occluded in Case 1 and decreased in Case 2. CONCLUSION: Compared to that with the Pipeline and Tubridge, the Surpass resulted in the greatest reduction in hemodynamic parameters and might be effective for aneurysms at the fetal posterior communicating artery. Virtual FD deployment and computational fluid dynamics analysis may be used to predict the treatment outcomes.


Assuntos
Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/cirurgia , Hemodinâmica , Resultado do Tratamento , Hidrodinâmica , Artérias
2.
Politics Life Sci ; 41(2): 232-255, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36880546

RESUMO

This is a registered report for a study of racial and ethnic variation in the relationship between negativity bias and political attitudes. Pioneering work on the psychological and biological roots of political orientation has suggested that political conservatism is driven in large part by enhanced negativity bias. This work has been criticized on several theoretical fronts, and recent replication attempts have failed. To dig deeper into the contours of when (and among whom) negativity bias predicts conservatism, we investigate a surprisingly overlooked factor in existing literature: race and ethnicity. We propose that political issues represent threat or disgust in different ways depending on one's race and ethnicity. We recruited 174 White, Latinx, and Asian American individuals (in equal numbers) to examine how the relationship between negativity bias and political orientation varies by race/ethnicity across four domains: policing/criminal justice, immigration, economic redistribution, and religious social conservatism.


Assuntos
Viés , Etnicidade , Política , Humanos , Asiático , Asco , Emigração e Imigração , Brancos , Hispânico ou Latino
3.
Interv Neuroradiol ; 26(5): 557-565, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32830566

RESUMO

BACKGROUND: The Low-profile Visualized Intraluminal Support device (LVIS) has been successfully used to treat cerebral aneurysm, and the push-pull technique has been used clinically to compact the stent across aneurysm orifice. Our aim was to exhibit the hemodynamic effect of the compacted LVIS stent. METHODS: Two patient-specific aneurysm models were constructed from three-dimensional angiographic images. The uniform LVIS stent, compacted LVIS and Pipeline Embolization Device (PED) with or without coil embolization were virtually deployed into aneurysm models to perform hemodynamic analysis. Intra-aneurysmal flow parameters were calculated to assess hemodynamic differences among different models. RESULTS: The compacted LVIS had the highest metal coverage across the aneurysm orifice (case 1, 46.37%; case 2, 67.01%). However, the PED achieved the highest pore density (case 1, 19.56 pores/mm2; case 2, 18.07 pores/mm2). The compacted LVIS produced a much higher intra-aneurysmal flow reduction than the uniform LVIS. The PED showed a higher intra-aneurysmal flow reduction than the compacted LVIS in case 1, but the results were comparable in case 2. After stent placement, the intra-aneurysmal flow was further reduced as subsequent coil embolization. The compacted LVIS stent with coils produced a similar reduction in intra-aneurysmal flow to that of the PED. CONCLUSIONS: The combined characteristics of stent metal coverage and pore density should be considered when assessing the flow diversion effects of stents. More intra-aneurysmal flow reductions could be introduced by compacted LVIS stent than the uniform one. Compared with PED, compacted LVIS stent may exhibit a flow-diverting effect comparable to that of the PED.


Assuntos
Embolização Terapêutica/métodos , Aneurisma Intracraniano/terapia , Stents , Hemorragia Subaracnóidea/terapia , Angiografia Digital , Angiografia Cerebral , Simulação por Computador , Hemodinâmica , Humanos , Hidrodinâmica , Imageamento Tridimensional , Aneurisma Intracraniano/diagnóstico por imagem , Angiografia por Ressonância Magnética , Desenho de Prótese , Hemorragia Subaracnóidea/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...