Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cell Rep ; 43(5): 114199, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38728138

RESUMO

Implantable electrode arrays are powerful tools for directly interrogating neural circuitry in the brain, but implementing this technology in the spinal cord in behaving animals has been challenging due to the spinal cord's significant motion with respect to the vertebral column during behavior. Consequently, the individual and ensemble activity of spinal neurons processing motor commands remains poorly understood. Here, we demonstrate that custom ultraflexible 1-µm-thick polyimide nanoelectronic threads can conduct laminar recordings of many neuronal units within the lumbar spinal cord of unrestrained, freely moving mice. The extracellular action potentials have high signal-to-noise ratio, exhibit well-isolated feature clusters, and reveal diverse patterns of activity during locomotion. Furthermore, chronic recordings demonstrate the stable tracking of single units and their functional tuning over multiple days. This technology provides a path for elucidating how spinal circuits compute motor actions.


Assuntos
Eletrodos Implantados , Medula Espinal , Animais , Medula Espinal/fisiologia , Camundongos , Potenciais de Ação/fisiologia , Atividade Motora/fisiologia , Neurônios/fisiologia , Locomoção/fisiologia , Camundongos Endogâmicos C57BL , Masculino
2.
Clin Oral Investig ; 27(1): 15-30, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36422719

RESUMO

OBJECTIVES: For a conventional indirect restoration, temporary cementation inevitably contaminated collapsed dentin collagen. The purpose of this review was to evaluate the optimal strategy for minimizing its negative effects. MATERIAL AND METHODS: Databases such as PubMed, Web of Science, EMBASE, and the Cochrane Library were searched for in vitro studies, involving the influence of immediate dentin sealing (IDS), different temporary cements, and their removal strategies on dentin bond strength. The meta-analysis used the inverse variance method with effect method of the standardized mean difference and statistical significance at p ≤ 0.05. The I2 value and the Q-test were used to assess the heterogeneity. RESULTS: A total of 14 in vitro trials were subjected to the meta-analysis. Within the study's limitations, we assumed that IDS eliminated the negative effects of temporary bonding, achieving the comparable immediate bond strength with the control (p = 0.46). In contrast, under delayed dentin sealing (DDS), temporary cementation statistically decreased bond strength (p = 0.002). Compared with resin-based and non-eugenol zinc oxide cements, polycarboxylate and calcium hydroxide cements performed better on bond strength with no statistical difference from the control group (p > 0.05). Among the removal methods of temporary cements, the Al2O3 abrasion restored the decreased bond strength (p = 0.07) and performed better than hand instruments alone (p = 0.04), while pumice removal slightly reduced the bond strength in contrast with the control group (p = 0.05, 95% CI = - 1.62 to 0). CONCLUSIONS: The choices of IDS, polycarboxylate and calcium hydroxide temporary cements, Al2O3 abrasion removal method were feasible and efficient to enhance the bond strength. CLINICAL RELEVANCE: It is worthwhile applying IDS technique, polycarboxylate and calcium hydroxide temporary cements during indirect restoration. The Al2O3 abrasion of cleaning dentin can minimize the negative effects of temporary cement.


Assuntos
Colagem Dentária , Cimentos de Resina , Cimentos de Resina/química , Colagem Dentária/métodos , Adesivos Dentinários/química , Hidróxido de Cálcio , Cimentos Dentários/química , Teste de Materiais , Dentina , Resistência à Tração , Análise do Estresse Dentário
3.
Biomaterials ; 291: 121905, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36403326

RESUMO

Flexible neural electrodes improve the recording longevity and quality of individual neurons by promoting tissue-electrode integration. However, the intracortical implantation of flexible electrodes inevitably induces tissue damage. Understanding the longitudinal neural and vascular recovery following the intracortical implantation is critical for the ever-growing applications of flexible electrodes in both healthy and disordered brains. Aged animals are of particular interest because they play a key role in modeling neurological disorders, but their tissue-electrode interface remains mostly unstudied. Here we integrate in-vivo two-photon imaging and electrophysiological recording to determine the time-dependent neural and vascular dynamics after the implantation of ultraflexible neural electrodes in aged mice. We find heightened angiogenesis and vascular remodeling in the first two weeks after implantation, which coincides with the rapid increase in local field potentials and unit activities detected by electrophysiological recordings. Vascular remodeling in shallow cortical layers preceded that in deeper layers, which often lasted longer than the recovery of neural signals. By six weeks post-implantation vascular abnormalities had subsided, resulting in normal vasculature and microcirculation. Putative cell classification based on firing pattern and waveform shows similar recovery time courses in fast-spiking interneurons and pyramidal neurons. These results elucidate how structural damages and remodeling near implants affecting recording efficacy, and support the application of ultraflexible electrodes in aged animals at minimal perturbations to endogenous neurophysiology.


Assuntos
Neurônios , Remodelação Vascular , Animais , Camundongos , Eletrodos , Encéfalo , Interneurônios
4.
Neurophotonics ; 9(3): 032204, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35036472

RESUMO

Significance: Electrophysiological recording and optical imaging are two prevalent neurotechnologies with complementary strengths, the combined application of which can significantly improve our capacity in deciphering neural circuits. Flexible electrode arrays can support longitudinal optical imaging in the same brain region, but their mechanical flexibility makes surgical preparation challenging. Here, we provide a step-by-step protocol by which an ultraflexible nanoelectronic thread is co-implanted with a cranial window in a single surgery to enable chronic, dual-modal measurements. Aim: The method uses 1 - µ m -thick polymer neural electrodes which conform to the site of implantation. The mechanical flexibility of the probe allows bending without breaking and enables long-lasting electrophysiological recordings of single-unit activities and concurrent, high-resolution optical imaging through the cranial window. Approach: The protocol describes methods and procedures to co-implant an ultraflexible electrode array and a glass cranial window in the mouse neocortex. The implantation strategy includes temporary attachment of flexible electrodes to a retractable tungsten-microwire insertion shuttle, craniotomy, stereotaxic insertion of the electrode array, skull fixation of the cranial window and electrode, and installation of a head plate. Results: The resultant implant allows simultaneous interrogation of brain activity both electrophysiologically and optically for several months. Importantly, a variety of optical imaging modalities, including wide-field fluorescent imaging, two-photon microscopy, and functional optical imaging, can be readily applied to the specific brain region where ultraflexible electrodes record from. Conclusions: The protocol describes a method for co-implantation of ultraflexible neural electrodes and a cranial window for chronic, multimodal measurements of brain activity in mice. Device preparation and surgical implantation are described in detail to guide the adaptation of these methods for other flexible neural implants and cranial windows.

5.
Dent Mater J ; 41(1): 1-10, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34471040

RESUMO

This review aims to evaluate whether the etch-and-rinse or self-etch mode is the better protocol for dentin adhesion by universal adhesives. A total of 15 articles were included in the meta-analysis. Two reviewers performed a literature search up to October 2020in four databases: PubMed, Web of Science, Embase, and the Cochrane Library. Without considering the difference in aging mode, the analysis of the immediate and long-term bond strength of dentin showed that there was no statistical significance between the etch-and-rinse and self-etch mode of universal adhesive, and the long-term bond strength decreased relative to the immediate. In vitro studies suggest that prior acid etching did not improve bond performance. Whether from the perspective of long-term bonding performance or simplifying operating procedures, the self-etch mode is preferred.


Assuntos
Colagem Dentária , Adesivos Dentinários , Adesivos , Cimentos Dentários , Dentina , Teste de Materiais , Cimentos de Resina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...