Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Knee Surg Sports Traumatol Arthrosc ; 23(12): 3601-6, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25178535

RESUMO

PURPOSE: Pseudo-patella baja (PPB) is a surgical complication that can arise from total knee arthroplasty and occurs when the patella tendon is not shortened but the level of the femorotibial joint line is elevated. The goal of this study was to assess the performance of a technique specifically designed to prevent the occurrence of PPB and its radiological results. METHODS: Ninety-nine patients undergoing total knee arthroplasty were included. Patients were divided into a non-correction group and a correction group. The correction group were applied an additional metal block in order to reduce the excess resection of the distal femur. To evaluate PPB, the change in the pre- and postoperative joint line was measured using the modified Blackburne-Peel Index (BPI). RESULTS: In the non-correction group, 68 of 74 cases showed an occurrence of PPB (92 %), in the correction group, 6 of 57 cases showed an occurrence of PPB (11 %). The preoperative-modified BPI of the non-correction group was not significantly different from that of the correction group (0.6 ± 0.1 vs. 0.6 ± 0.2). The modified BPI decreased significantly in the non-correction group after TKA (0.6 ± 0.1 vs. 0.2 ± 0.1, p < 0.05). However, the modified BPI did not change significantly in the correction group after TKA (0.6 ± 0.2 vs. 0.6 ± 0.2). CONCLUSION: The comparison of preoperative and postoperative radiological results showed that our intervention maintained the joint line without elevation. We proposed an effective method to prevent various complications due to the joint line elevation that occur in PPB. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Joelho/efeitos adversos , Articulação do Joelho/patologia , Ligamento Patelar/patologia , Idoso , Animais , Artroplastia do Joelho/métodos , Feminino , Fêmur/cirurgia , Humanos , Articulação do Joelho/cirurgia , Masculino , Patela/cirurgia , Ligamento Patelar/cirurgia , Período Pós-Operatório
2.
BMC Musculoskelet Disord ; 15: 433, 2014 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-25510950

RESUMO

BACKGROUND: The prosthesis of contemporary total knee arthroplasty (TKA) has been modified to provide a more familiar environment for higher flexion angle of the replaced knee. The design modifications continue based on evidence reported in the literature. However, whether these modifications of the prosthesis design lead to improvements in clinical results needs further investigation. We determined whether the prosthesis modifications based on recent evidence improve clinical and radiographic results following high flexion TKA. METHODS: 524 patients who underwent primary TKA using two different high flexion prostheses were divided to Group 1 (HF-1) using a high flexion prosthesis, group 2 (HF-2) using the more recently devised high flexion prosthesis, which claims to be adopted from evidence proposed in the literature. Clinical outcomes included ranges of motion (ROM), the Knee Society knee and function score (KSKS and KSFS), the Western Ontario and McMaster Universities Arthritis Index (WOMAC) score, radiologic evaluation, and complication related to surgery. RESULTS: No differences in terms of clinical and radiographic results were observed between the groups at the 2 year follow-up. The mean ROM was 123°and 124° in the HF-1 and HF-2 groups, respectively. KSKS were 90 and 89.1, KSFS were 76.6 and 81.8, and total WOMAC scores were 23.1 and 24.9 in the HF-1 and HF- 2 groups. No differences of the incidences of radiolucency on radiographs (1.4% in HF-1, 2.1% in HF-2) and dislocation (1 case in HF-1 only) was observed. CONCLUSIONS: Even if recent modifications in the design of high flexion TKA prosthesis were based on evidence in the literature, they did not provide meaningful improvements in short-term clinical and radiographic outcomes after TKA. Surgeons should consider our findings when choosing a prosthesis for their patients.


Assuntos
Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/tendências , Prótese do Joelho/tendências , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Desenho de Prótese/tendências , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Amplitude de Movimento Articular/fisiologia , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
3.
Yonsei Med J ; 54(6): 1505-10, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24142658

RESUMO

PURPOSE: We devised an intraoperatively identifiable mechanical axis (IIMA) as a reference of alignment in total knee arthroplasty (TKA). MATERIALS AND METHODS: Between February 2010 and January 2011, primary TKAs were consecutively performed on 672 patients (1007 knees) using an IIMA as a reference in the coronal plane. RESULTS: The alignment of the lower extremity improved from a mean of 11.4±6.7° (-10.3-34.4°) of varus preop. to 0.7±3.5° (-5.2-8.6°) immediately after surgery. Mean alignment of the femoral component in the coronal plane was 89.3±2.3° (83.4-97.2°) postop. and mean alignment of the tibial component was 90.4±2.2° (85.1-94.2°) postop. CONCLUSION: This study showed that IIMA could be of considerable value as a new guider of alignment that is easily accessible and highly effective during total knee arthroplasty.


Assuntos
Artroplastia do Joelho/métodos , Fêmur/cirurgia , Humanos , Tíbia/cirurgia
4.
Knee Surg Relat Res ; 25(2): 60-4, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23741700

RESUMO

PURPOSE: To assess proper soft tissue balancing of the varus arthritic knee between posterior oblique ligament (POL) release group and superficial medial collateral ligament (SMCL) release group. MATERIALS AND METHODS: This retrospective study was performed on 186 patients who underwent minimally invasive surgery (MIS) total knee arthroplasty (TKA) from January 2011 to December 2011. Eighty-three patients were in the group of SMCL release and 103 patients were in the POL release group. We intended to use a 10 mm polyethylene insert (PE) during TKA, and retrospectively compared the actual thickness of PE between POL release group and SMCL release group. RESULTS: The mean PE thickness was 10.59±1.3 mm (range, 8 to 15 mm) in POL group and 11.88±1.8 mm (range, 10 to 18 mm) in SMCL group (p=0.001). We found a significant difference in the mean PE thickness between POL release group and SMCL release group. CONCLUSIONS: POL and deep MCL releases in MIS-TKA would be beneficial for varus deformity correction in the osteoarthritic knee.

5.
Mol Med Rep ; 7(2): 489-94, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23229788

RESUMO

Tissue inhibitors of metalloproteinases (TIMPs) are involved in synaptic plasticity, neuronal cell differentiation and neuroprotection in the central nervous system. To investigate whether TIMP4 polymorphisms are associated with schizophrenia and autism spectrum disorders (ASDs), 480 patients (schizophrenia, n=287; ASDs, n=193) and 296 controls were enrolled. Clinical symptoms of schizophrenia and ASDs were assessed using the operation criteria checklist for psychotic illness (OPCRIT) and Childhood Autism Rating Scale (CARS), respectively. One promoter single nucleotide polymorphism (SNP; rs3755724, -55C/T) and one exonic SNP (rs17035945, 3'-untranslated region) were selected. SNPStats and SNPAnalyzer Pro programs were used to calculate odds ratios. Multiple logistic regression models were performed to analyze the genetic data. Based on the results, these two SNPs were not associated with schizophrenia and ASD. In the analysis of clinical features of schizophrenia, rs3755724 was nominally associated with schizophrenia with poor concentration (P=0.044 in the codominant2 model, P=0.041 in the log-additive model and P=0.043 in allele frequency). These results suggest that TIMP4 is not associated with the development of schizophrenia and ASD in the population studied.


Assuntos
Transtornos Globais do Desenvolvimento Infantil/genética , Polimorfismo de Nucleotídeo Único , Esquizofrenia/genética , Inibidores Teciduais de Metaloproteinases/genética , Adolescente , Adulto , Alelos , Criança , Éxons , Feminino , Frequência do Gene , Genótipo , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Regiões Promotoras Genéticas , Adulto Jovem , Inibidor Tecidual 4 de Metaloproteinase
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...