Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(14)2022 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-35890756

RESUMO

This paper presents a field implementation of the structural health monitoring (SHM) of fatigue cracks for steel bridge structures. Steel bridges experience fatigue cracks under repetitive traffic loading, which pose great threats to their structural integrity and can lead to catastrophic failures. Currently, accurate and reliable fatigue crack monitoring for the safety assessment of bridges is still a difficult task. On the other hand, wireless smart sensors have achieved great success in global SHM by enabling long-term modal identifications of civil structures. However, long-term field monitoring of localized damage such as fatigue cracks has been limited due to the lack of effective sensors and the associated algorithms specifically designed for fatigue crack monitoring. To fill this gap, this paper proposes a wireless large-area strain sensor (WLASS) to measure large-area strain fatigue cracks and develops an effective algorithm to process the measured large-area strain data into actionable information. The proposed WLASS consists of a soft elastomeric capacitor (SEC) used to measure large-area structural surface strain, a capacitive sensor board to convert the signal from SEC to a measurable change in voltage, and a commercial wireless smart sensor platform for triggered-based wireless data acquisition, remote data retrieval, and cloud storage. Meanwhile, the developed algorithm for fatigue crack monitoring processes the data obtained from the WLASS under traffic loading through three automated steps, including (1) traffic event detection, (2) time-frequency analysis using a generalized Morse wavelet (GM-CWT) and peak identification, and (3) a modified crack growth index (CGI) that tracks potential fatigue crack growth. The developed WLASS and the algorithm present a complete system for long-term fatigue crack monitoring in the field. The effectiveness of the proposed time-frequency analysis algorithm based on GM-CWT to reliably extract the impulsive traffic events is validated using a numerical investigation. Subsequently, the developed WLASS and algorithm are validated through a field deployment on a steel highway bridge in Kansas City, KS, USA.


Assuntos
Tecnologia de Sensoriamento Remoto , Aço , Colapso Estrutural , Humanos
2.
Sensors (Basel) ; 21(21)2021 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-34770326

RESUMO

The authors have previously proposed corrugated soft elastomeric capacitors (cSEC) to create ultra compliant scalable strain gauges. The cSEC technology has been successfully demonstrated in engineering and biomechanical applications for in-plane strain measurements. This study extends work on the cSEC to evaluate its performance at measuring angular rotation when installed folded at the junction of two plates. The objective is to characterize the sensor's electromechanical behavior anticipating applications to the monitoring of welded connections in steel components. To do so, an electromechanical model that maps the cSEC signal to bending strain induced by angular rotation is derived and adjusted using a validated finite element model. Given the difficulty in mapping strain measurements to rotation, an algorithm termed angular rotation index (ARI) is formulated to link measurements to angular rotation directly. Experimental work is conducted on a hollow structural section (HSS) steel specimen equipped with cSECs subjected to compression to generate angular rotations at the corners within the cross-section. Results confirm that the cSEC is capable of tracking angular rotation-induced bending strain linearly, however with accuracy levels significantly lower than found over flat configurations. Nevertheless, measurements were mapped to angular rotations using the ARI, and it was found that the ARI mapped linearly to the angle of rotation, with an accuracy of 0.416∘.


Assuntos
Aço , Fenômenos Biomecânicos , Elasticidade , Pressão
3.
BMC Biomed Eng ; 2: 3, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32903362

RESUMO

BACKGROUND: The characterization of limb biomechanics has broad implications for analyzing and managing motion in aging, sports, and disease. Motion capture videography and on-body wearable sensors are powerful tools for characterizing linear and angular motions of the body, though are often cumbersome, limited in detection, and largely non-portable. Here we examine the feasibility of utilizing an advanced wearable sensor, fabricated with stretchable electronics, to characterize linear and angular movements of the human arm for clinical feedback. A wearable skin-adhesive patch with embedded accelerometer and gyroscope (BioStampRC, MC10 Inc.) was applied to the volar surface of the forearm of healthy volunteers. Arms were extended/flexed for the range of motion of three different regimes: 1) horizontal adduction/abduction 2) flexion/extension 3) vertical abduction. Data were streamed and recorded revealing the signal "pattern" of movement in three separate axes. Additional signal processing and filtering afforded the ability to visualize these motions in each plane of the body; and the 3-dimensional motion envelope of the arm. RESULTS: Each of the three motion regimes studied had a distinct pattern - with identifiable qualitative and quantitative differences. Integration of all three movement regimes allowed construction of a "motion envelope," defining and quantifying motion (range and shape - including the outer perimeter of the extreme of motion - i.e. the envelope) of the upper extremity. The linear and rotational motion results from multiple arm motions match measurements taken with videography and benchtop goniometer. CONCLUSIONS: A conformal, stretchable electronic motion sensor effectively captures limb motion in multiple degrees of freedom, allowing generation of characteristic signatures which may be readily recorded, stored, and analyzed. Wearable conformal skin adherent sensor patchs allow on-body, mobile, personalized determination of motion and flexibility parameters. These sensors allow motion assessment while mobile, free of a fixed laboratory environment, with utility in the field, home, or hospital. These sensors and mode of analysis hold promise for providing digital "motion biomarkers" of health and disease.

4.
Sensors (Basel) ; 17(11)2017 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-29149088

RESUMO

Direct measurements of external forces acting on a structure are infeasible in many cases. The Augmented Kalman Filter (AKF) has several attractive features that can be utilized to solve the inverse problem of identifying applied forces, as it requires the dynamic model and the measured responses of structure at only a few locations. But, the AKF intrinsically suffers from numerical instabilities when accelerations, which are the most common response measurements in structural dynamics, are the only measured responses. Although displacement measurements can be used to overcome the instability issue, the absolute displacement measurements are challenging and expensive for full-scale dynamic structures. In this paper, a reliable model-based data fusion approach to reconstruct dynamic forces applied to structures using heterogeneous structural measurements (i.e., strains and accelerations) in combination with AKF is investigated. The way of incorporating multi-sensor measurements in the AKF is formulated. Then the formulation is implemented and validated through numerical examples considering possible uncertainties in numerical modeling and sensor measurement. A planar truss example was chosen to clearly explain the formulation, while the method and formulation are applicable to other structures as well.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...