Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cardiovasc Comput Tomogr ; 14(1): 36-41, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31327744

RESUMO

BACKGROUND: To investigate the impact of left ventricular outflow tract (LVOT) calcification on the incidence of device failure and mortality in patients undergoing transcatheter aortic valve implantation (TAVI). METHODS: Of 690 consecutive patients undergoing transfemoral TAVI in our center from January 2013 to December 2015, 600 presented with non-severe (NSCALVOT) and 90 (13.0%) with severe (SCALVOT) LVOT calcification. Primary outcome of interest was device failure defined as a composite of procedural death, prosthesis dislocation, annulus rupture or significant para-valvular leakage (PVL). Secondary outcome of interest was 30-day and one-year all-cause mortality. RESULTS: Mean age of the population was 80.8 ±â€¯7.2 years, mean STS score was 5.7 ±â€¯4.6% and 50.6% of the patients were women. Patients with SCALVOT more frequently experienced device failure (10.0% vs. 3.8%, p = 0.009) and were at higher risk of 30 day (10.0% vs. 2.8%, p < 0.001) all cause mortality as compared to those with NSCALVOT. Furthermore, patients with SCALVOT were more frequently in need of post-dilation (15.6% vs. 8.5%, p = 0.032) and showed higher incidence of significant PVL (7.8% vs. 2.5%, p = 0.007). In multivariate analysis, SCALVOT (hazard ratio 2.87; 95% CI 1.20 to 6.34) and use of balloon-expandable prosthesis (hazard ratio 0.32; 95% CI 0.15 to 0.73) were identified as independent predictors of device failure. CONCLUSION: Presence of severe LVOT calcification in patients undergoing transfemoral TAVI is associated with a higher risk of device failure and short-term mortality.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Calcinose/cirurgia , Próteses Valvulares Cardíacas , Falha de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Calcinose/diagnóstico por imagem , Calcinose/mortalidade , Calcinose/fisiopatologia , Bases de Dados Factuais , Feminino , Alemanha/epidemiologia , Humanos , Incidência , Masculino , Tomografia Computadorizada Multidetectores , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...