Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Cogn Neurodyn ; 18(2): 383-404, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38699621

RESUMO

Fibromyalgia is a soft tissue rheumatism with significant qualitative and quantitative impact on sleep macro and micro architecture. The primary objective of this study is to analyze and identify automatically healthy individuals and those with fibromyalgia using sleep electroencephalography (EEG) signals. The study focused on the automatic detection and interpretation of EEG signals obtained from fibromyalgia patients. In this work, the sleep EEG signals are divided into 15-s and a total of 5358 (3411 healthy control and 1947 fibromyalgia) EEG segments are obtained from 16 fibromyalgia and 16 normal subjects. Our developed model has advanced multilevel feature extraction architecture and hence, we used a new feature extractor called GluPat, inspired by the glucose chemical, with a new pooling approach inspired by the D'hondt selection system. Furthermore, our proposed method incorporated feature selection techniques using iterative neighborhood component analysis and iterative Chi2 methods. These selection mechanisms enabled the identification of discriminative features for accurate classification. In the classification phase, we employed a support vector machine and k-nearest neighbor algorithms to classify the EEG signals with leave-one-record-out (LORO) and tenfold cross-validation (CV) techniques. All results are calculated channel-wise and iterative majority voting is used to obtain generalized results. The best results were determined using the greedy algorithm. The developed model achieved a detection accuracy of 100% and 91.83% with a tenfold and LORO CV strategies, respectively using sleep stage (2 + 3) EEG signals. Our generated model is simple and has linear time complexity.

2.
Comput Biol Med ; 140: 105120, 2021 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-34896884

RESUMO

BACKGROUND: The most prevalent neuropsychiatric disorder among children is attention deficit hyperactivity disorder (ADHD). ADHD presents with a high prevalence of comorbid disorders such as conduct disorder (CD). The lack of definitive confirmatory diagnostic tests for ADHD and CD make diagnosis challenging. The distinction between ADHD, ADHD + CD and CD is important as the course and treatment are different. Electrocardiography (ECG) signals may become altered in behavioral disorders due to brain-heart autonomic interactions. We have developed a software tool to categorize ADHD, ADHD + CD and CD automatically on ECG signals. METHOD: ECG signals from participants were decomposed using empirical wavelet transform into various modes, from which entropy features were extracted. Robust ten-fold cross-validation with adaptive synthetic sampling (ADASYN) and z-score normalization were performed at each fold. Analysis of variance (ANOVA) technique was employed to determine the variability within the three classes, and obtained the most discriminatory features. Highly significant entropy features were then fed to classifiers. RESULTS: Our model yielded the best classification results with the bagged tree classifier: 87.19%, 87.71% and 86.29% for accuracy, sensitivity and specificity, respectively. CONCLUSION: The proposed expert system can potentially assist mental health professionals in the stratification of the three classes, for appropriate intervention using accessible ECG signals.

3.
Comput Methods Programs Biomed ; 166: 91-98, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30415722

RESUMO

BACKGROUND AND OBJECTIVE: Liver fibrosis is a type of chronic liver injury that is characterized by an excessive deposition of extracellular matrix protein. Early detection of liver fibrosis may prevent further growth toward liver cirrhosis and hepatocellular carcinoma. In the past, the only method to assess liver fibrosis was through biopsy, but this examination is invasive, expensive, prone to sampling errors, and may cause complications such as bleeding. Ultrasound-based elastography is a promising tool to measure tissue elasticity in real time; however, this technology requires an upgrade of the ultrasound system and software. In this study, a novel computer-aided diagnosis tool is proposed to automatically detect and classify the various stages of liver fibrosis based upon conventional B-mode ultrasound images. METHODS: The proposed method uses a 2D contourlet transform and a set of texture features that are efficiently extracted from the transformed image. Then, the combination of a kernel discriminant analysis (KDA)-based feature reduction technique and analysis of variance (ANOVA)-based feature ranking technique was used, and the images were then classified into various stages of liver fibrosis. RESULTS: Our 2D contourlet transform and texture feature analysis approach achieved a 91.46% accuracy using only four features input to the probabilistic neural network classifier, to classify the five stages of liver fibrosis. It also achieved a 92.16% sensitivity and 88.92% specificity for the same model. The evaluation was done on a database of 762 ultrasound images belonging to five different stages of liver fibrosis. CONCLUSIONS: The findings suggest that the proposed method can be useful to automatically detect and classify liver fibrosis, which would greatly assist clinicians in making an accurate diagnosis.


Assuntos
Cirrose Hepática/fisiopatologia , Fígado/fisiopatologia , Adulto , Idoso , Algoritmos , Técnicas de Imagem por Elasticidade , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Cirrose Hepática/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Redes Neurais de Computação , Reconhecimento Automatizado de Padrão , Probabilidade , Sensibilidade e Especificidade , Software , Ultrassonografia
4.
Comput Biol Med ; 92: 204-209, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-29227822

RESUMO

Untreated age-related macular degeneration (AMD), diabetic retinopathy (DR), and glaucoma may lead to irreversible vision loss. Hence, it is essential to have regular eye screening to detect these eye diseases at an early stage and to offer treatment where appropriate. One of the simplest, non-invasive and cost-effective techniques to screen the eyes is by using fundus photo imaging. But, the manual evaluation of fundus images is tedious and challenging. Further, the diagnosis made by ophthalmologists may be subjective. Therefore, an objective and novel algorithm using the pyramid histogram of visual words (PHOW) and Fisher vectors is proposed for the classification of fundus images into their respective eye conditions (normal, AMD, DR, and glaucoma). The proposed algorithm extracts features which are represented as words. These features are built and encoded into a Fisher vector for classification using random forest classifier. This proposed algorithm is validated with both blindfold and ten-fold cross-validation techniques. An accuracy of 90.06% is achieved with the blindfold method, and highest accuracy of 96.79% is obtained with ten-fold cross-validation. The highest classification performance of our system shows the potential of deploying it in polyclinics to assist healthcare professionals in their initial diagnosis of the eye. Our developed system can reduce the workload of ophthalmologists significantly.


Assuntos
Técnicas de Diagnóstico Oftalmológico , Interpretação de Imagem Assistida por Computador/métodos , Retina/diagnóstico por imagem , Doenças Retinianas/diagnóstico por imagem , Algoritmos , Fundo de Olho , Glaucoma/diagnóstico por imagem , Humanos
5.
Comput Biol Med ; 91: 13-20, 2017 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-29031099

RESUMO

Shear wave elastography (SWE) examination using ultrasound elastography (USE) is a popular imaging procedure for obtaining elasticity information of breast lesions. Elasticity parameters obtained through SWE can be used as biomarkers that can distinguish malignant breast lesions from benign ones. Furthermore, the elasticity parameters extracted from SWE can speed up the diagnosis and possibly reduce human errors. In this paper, Shearlet transform and local binary pattern histograms (LBPH) are proposed as an original algorithm to differentiate malignant and benign breast lesions. First, Shearlet transform is applied on the SWE images to acquire low frequency, horizontal and vertical cone coefficients. Next, LBPH features are extracted from the Shearlet transform coefficients and subjected to dimensionality reduction using locality sensitivity discriminating analysis (LSDA). The reduced LSDA components are ranked and then fed to several classifiers for the automated classification of breast lesions. A probabilistic neural network classifier trained only with seven top ranked features performed best, and achieved 98.08% accuracy, 98.63% sensitivity, and 97.59% specificity in distinguishing malignant from benign breast lesions. The high sensitivity and specificity of our system indicates that it can be employed as a primary screening tool for faster diagnosis of breast malignancies, thereby possibly reducing the mortality rate due to breast cancer.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Interpretação de Imagem Assistida por Computador/métodos , Algoritmos , Mama/diagnóstico por imagem , Feminino , Humanos , Sensibilidade e Especificidade
6.
Comput Biol Med ; 88: 72-83, 2017 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-28700902

RESUMO

Glaucoma is an optic neuropathy defined by characteristic damage to the optic nerve and accompanying visual field deficits. Early diagnosis and treatment are critical to prevent irreversible vision loss and ultimate blindness. Current techniques for computer-aided analysis of the optic nerve and retinal nerve fiber layer (RNFL) are expensive and require keen interpretation by trained specialists. Hence, an automated system is highly desirable for a cost-effective and accurate screening for the diagnosis of glaucoma. This paper presents a new methodology and a computerized diagnostic system. Adaptive histogram equalization is used to convert color images to grayscale images followed by convolution of these images with Leung-Malik (LM), Schmid (S), and maximum response (MR4 and MR8) filter banks. The basic microstructures in typical images are called textons. The convolution process produces textons. Local configuration pattern (LCP) features are extracted from these textons. The significant features are selected using a sequential floating forward search (SFFS) method and ranked using the statistical t-test. Finally, various classifiers are used for classification of images into normal and glaucomatous classes. A high classification accuracy of 95.8% is achieved using six features obtained from the LM filter bank and the k-nearest neighbor (kNN) classifier. A glaucoma integrative index (GRI) is also formulated to obtain a reliable and effective system.


Assuntos
Algoritmos , Glaucoma/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Reconhecimento Automatizado de Padrão/métodos , Técnicas de Diagnóstico Oftalmológico , Humanos
7.
Comput Biol Med ; 84: 59-68, 2017 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-28343061

RESUMO

The cause of diabetic macular edema (DME) is due to prolonged and uncontrolled diabetes mellitus (DM) which affects the vision of diabetic subjects. DME is graded based on the exudate location from the macula. It is clinically diagnosed using fundus images which is tedious and time-consuming. Regular eye screening and subsequent treatment may prevent the vision loss. Hence, in this work, a hybrid system based on Radon transform (RT), discrete wavelet transform (DWT) and discrete cosine transform (DCT) are proposed for an automated detection of DME. The fundus images are subjected to RT to obtain sinograms and DWT is applied on these sinograms to extract wavelet coefficients (approximate, horizontal, vertical and diagonal). DCT is applied on approximate coefficients to obtain 2D-DCT coefficients. Further, these coefficients are converted into 1D vector by arranging the coefficients in zig-zag manner. This 1D signal is subjected to locality sensitive discriminant analysis (LSDA). Finally, various supervised classifiers are used to classify the three classes using significant features. Our proposed technique yielded a classification accuracy of 100% and 97.01% using two and seven significant features for private and public (MESSIDOR) databases respectively. Also, a maculopathy index is formulated with two significant parameters to discriminate the three groups distinctly using a single integer. Hence, our obtained results suggest that this system can be used as an eye screening tool for diabetic subjects for DME.


Assuntos
Retinopatia Diabética/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Edema Macular/diagnóstico por imagem , Adulto , Idoso , Algoritmos , Análise Discriminante , Feminino , Fundo de Olho , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Ondaletas
8.
Comput Biol Med ; 84: 89-97, 2017 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-28351716

RESUMO

Vision is paramount to humans to lead an active personal and professional life. The prevalence of ocular diseases is rising, and diseases such as glaucoma, Diabetic Retinopathy (DR) and Age-related Macular Degeneration (AMD) are the leading causes of blindness in developed countries. Identifying these diseases in mass screening programmes is time-consuming, labor-intensive and the diagnosis can be subjective. The use of an automated computer aided diagnosis system will reduce the time taken for analysis and will also reduce the inter-observer subjective variabilities in image interpretation. In this work, we propose one such system for the automatic classification of normal from abnormal (DR, AMD, glaucoma) images. We had a total of 404 normal and 1082 abnormal fundus images in our database. As the first step, 2D-Continuous Wavelet Transform (CWT) decomposition on the fundus images of two classes was performed. Subsequently, energy features and various entropies namely Yager, Renyi, Kapoor, Shannon, and Fuzzy were extracted from the decomposed images. Then, adaptive synthetic sampling approach was applied to balance the normal and abnormal datasets. Next, the extracted features were ranked according to the significances using Particle Swarm Optimization (PSO). Thereupon, the ranked and selected features were used to train the random forest classifier using stratified 10-fold cross validation. Overall, the proposed system presented a performance rate of 92.48%, and a sensitivity and specificity of 89.37% and 95.58% respectively using 15 features. This novel system shows promise in detecting abnormal fundus images, and hence, could be a valuable adjunct eye health screening tool that could be employed in polyclinics, and thereby reduce the workload of specialists at hospitals.


Assuntos
Fundo de Olho , Interpretação de Imagem Assistida por Computador/métodos , Retina/diagnóstico por imagem , Doenças Retinianas/diagnóstico por imagem , Análise de Ondaletas , Bases de Dados Factuais , Técnicas de Diagnóstico Oftalmológico , Entropia , Glaucoma/diagnóstico por imagem , Humanos
9.
Comput Biol Med ; 75: 54-62, 2016 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-27253617

RESUMO

Posterior Segment Eye Diseases (PSED) namely Diabetic Retinopathy (DR), glaucoma and Age-related Macular Degeneration (AMD) are the prime causes of vision loss globally. Vision loss can be prevented, if these diseases are detected at an early stage. Structural abnormalities such as changes in cup-to-disc ratio, Hard Exudates (HE), drusen, Microaneurysms (MA), Cotton Wool Spots (CWS), Haemorrhages (HA), Geographic Atrophy (GA) and Choroidal Neovascularization (CNV) in PSED can be identified by manual examination of fundus images by clinicians. However, manual screening is labour-intensive, tiresome and time consuming. Hence, there is a need to automate the eye screening. In this work Bi-dimensional Empirical Mode Decomposition (BEMD) technique is used to decompose fundus images into 2D Intrinsic Mode Functions (IMFs) to capture variations in the pixels due to morphological changes. Further, various entropy namely Renyi, Fuzzy, Shannon, Vajda, Kapur and Yager and energy features are extracted from IMFs. These extracted features are ranked using Chernoff Bound and Bhattacharyya Distance (CBBD), Kullback-Leibler Divergence (KLD), Fuzzy-minimum Redundancy Maximum Relevance (FmRMR), Wilcoxon, Receiver Operating Characteristics Curve (ROC) and t-test methods. Further, these ranked features are fed to Support Vector Machine (SVM) classifier to classify normal and abnormal (DR, AMD and glaucoma) classes. The performance of the proposed eye screening system is evaluated using 800 (Normal=400 and Abnormal=400) digital fundus images and 10-fold cross validation method. Our proposed system automatically identifies normal and abnormal classes with an average accuracy of 88.63%, sensitivity of 86.25% and specificity of 91% using 17 optimal features ranked using CBBD and SVM-Radial Basis Function (RBF) classifier. Moreover, a novel Retinal Risk Index (RRI) is developed using two significant features to distinguish two classes using single number. Such a system helps to reduce eye screening time in polyclinics or community-based mass screening. They will refer the patients to main hospitals only if the diagnosis belong to the abnormal class. Hence, the main hospitals will not be unnecessarily crowded and doctors can devote their time for other urgent cases.


Assuntos
Retinopatia Diabética/diagnóstico por imagem , Glaucoma/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Degeneração Macular/diagnóstico por imagem , Retina/diagnóstico por imagem , Adulto , Idoso , Humanos , Masculino , Pessoa de Meia-Idade
10.
Comput Biol Med ; 73: 131-40, 2016 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-27107676

RESUMO

Age-related Macular Degeneration (AMD) affects the central vision of aged people. It can be diagnosed due to the presence of drusen, Geographic Atrophy (GA) and Choroidal Neovascularization (CNV) in the fundus images. It is labor intensive and time-consuming for the ophthalmologists to screen these images. An automated digital fundus photography based screening system can overcome these drawbacks. Such a safe, non-contact and cost-effective platform can be used as a screening system for dry AMD. In this paper, we are proposing a novel algorithm using Radon Transform (RT), Discrete Wavelet Transform (DWT) coupled with Locality Sensitive Discriminant Analysis (LSDA) for automated diagnosis of AMD. First the image is subjected to RT followed by DWT. The extracted features are subjected to dimension reduction using LSDA and ranked using t-test. The performance of various supervised classifiers namely Decision Tree (DT), Support Vector Machine (SVM), Probabilistic Neural Network (PNN) and k-Nearest Neighbor (k-NN) are compared to automatically discriminate to normal and AMD classes using ranked LSDA components. The proposed approach is evaluated using private and public datasets such as ARIA and STARE. The highest classification accuracy of 99.49%, 96.89% and 100% are reported for private, ARIA and STARE datasets. Also, AMD index is devised using two LSDA components to distinguish two classes accurately. Hence, this proposed system can be extended for mass AMD screening.


Assuntos
Algoritmos , Neovascularização de Coroide/diagnóstico por imagem , Bases de Dados Factuais , Processamento de Imagem Assistida por Computador/métodos , Degeneração Macular/diagnóstico por imagem , Máquina de Vetores de Suporte , Feminino , Humanos , Masculino , Medição de Risco
11.
Eur Neurol ; 74(1-2): 79-83, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26303033

RESUMO

Depression is a mental disorder characterized by persistent occurrences of lower mood states in the affected person. The electroencephalogram (EEG) signals are highly complex, nonlinear, and nonstationary in nature. The characteristics of the signal vary with the age and mental state of the subject. The signs of abnormality may be invisible to the naked eyes. Even when they are visible, deciphering the minute changes indicating abnormality is tedious and time consuming for the clinicians. This paper presents a novel method for automated EEG-based diagnosis of depression using nonlinear methods: fractal dimension, largest Lyapunov exponent, sample entropy, detrended fluctuation analysis, Hurst's exponent, higher order spectra, and recurrence quantification analysis. A novel Depression Diagnosis Index (DDI) is presented through judicious combination of the nonlinear features. The DDI calculated automatically based on the EEG recordings can be used to diagnose depression objectively using just one numeric value. Also, these features extracted from nonlinear methods are ranked using the t value and fed to the support vector machine (SVM) classifier. The SVM classifier yielded the highest classification performance with an average accuracy of about 98%, sensitivity of about 97%, and specificity of about 98.5%.


Assuntos
Depressão/diagnóstico , Eletroencefalografia/métodos , Humanos , Dinâmica não Linear , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador
12.
Comput Biol Med ; 63: 208-18, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26093788

RESUMO

Age-related Macular Degeneration (AMD) is an irreversible and chronic medical condition characterized by drusen, Choroidal Neovascularization (CNV) and Geographic Atrophy (GA). AMD is one of the major causes of visual loss among elderly people. It is caused by the degeneration of cells in the macula which is responsible for central vision. AMD can be dry or wet type, however dry AMD is most common. It is classified into early, intermediate and late AMD. The early detection and treatment may help one to stop the progression of the disease. Automated AMD diagnosis may reduce the screening time of the clinicians. In this work, we have introduced LCP to characterize normal and AMD classes using fundus images. Linear Configuration Coefficients (CC) and Pattern Occurrence (PO) features are extracted from fundus images. These extracted features are ranked using p-value of the t-test and fed to various supervised classifiers viz. Decision Tree (DT), Nearest Neighbour (k-NN), Naive Bayes (NB), Probabilistic Neural Network (PNN) and Support Vector Machine (SVM) to classify normal and AMD classes. The performance of the system is evaluated using both private (Kasturba Medical Hospital, Manipal, India) and public domain datasets viz. Automated Retinal Image Analysis (ARIA) and STructured Analysis of the Retina (STARE) using ten-fold cross validation. The proposed approach yielded best performance with a highest average accuracy of 97.78%, sensitivity of 98.00% and specificity of 97.50% for STARE dataset using 22 significant features. Hence, this system can be used as an aiding tool to the clinicians during mass eye screening programs to diagnose AMD.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Degeneração Macular/diagnóstico , Retina/patologia , Máquina de Vetores de Suporte , Feminino , Humanos , Masculino , Sensibilidade e Especificidade
13.
Eur Neurol ; 73(5-6): 329-36, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25997732

RESUMO

The complex, nonlinear and non-stationary electroencephalogram (EEG) signals are very tedious to interpret visually and highly difficult to extract the significant features from them. The linear and nonlinear methods are effective in identifying the changes in EEG signals for the detection of depression. Linear methods do not exhibit the complex dynamical variations in the EEG signals. Hence, chaos theory and nonlinear dynamic methods are widely used in extracting the EEG signal features for computer-aided diagnosis (CAD) of depression. Hence, this article presents the recent efforts on CAD of depression using EEG signals with a focus on using nonlinear methods. Such a CAD system is simple to use and may be used by the clinicians as a tool to confirm their diagnosis. It should be of a particular value to enable the early detection of depression.


Assuntos
Depressão/diagnóstico , Diagnóstico por Computador/métodos , Eletroencefalografia/métodos , Processamento de Sinais Assistido por Computador , Humanos , Dinâmica não Linear
14.
Med Biol Eng Comput ; 53(12): 1319-31, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25894464

RESUMO

Diabetic macular edema (DME) is one of the most common causes of visual loss among diabetes mellitus patients. Early detection and successive treatment may improve the visual acuity. DME is mainly graded into non-clinically significant macular edema (NCSME) and clinically significant macular edema according to the location of hard exudates in the macula region. DME can be identified by manual examination of fundus images. It is laborious and resource intensive. Hence, in this work, automated grading of DME is proposed using higher-order spectra (HOS) of Radon transform projections of the fundus images. We have used third-order cumulants and bispectrum magnitude, in this work, as features, and compared their performance. They can capture subtle changes in the fundus image. Spectral regression discriminant analysis (SRDA) reduces feature dimension, and minimum redundancy maximum relevance method is used to rank the significant SRDA components. Ranked features are fed to various supervised classifiers, viz. Naive Bayes, AdaBoost and support vector machine, to discriminate No DME, NCSME and clinically significant macular edema classes. The performance of our system is evaluated using the publicly available MESSIDOR dataset (300 images) and also verified with a local dataset (300 images). Our results show that HOS cumulants and bispectrum magnitude obtained an average accuracy of 95.56 and 94.39% for MESSIDOR dataset and 95.93 and 93.33% for local dataset, respectively.


Assuntos
Retinopatia Diabética/classificação , Retinopatia Diabética/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Edema Macular/classificação , Edema Macular/diagnóstico , Adulto , Técnicas de Diagnóstico Oftalmológico , Humanos , Pessoa de Meia-Idade , Curva ROC , Adulto Jovem
15.
Med Biol Eng Comput ; 52(9): 781-96, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25112273

RESUMO

Age-related macular degeneration (AMD) affects the central vision and subsequently may lead to visual loss in people over 60 years of age. There is no permanent cure for AMD, but early detection and successive treatment may improve the visual acuity. AMD is mainly classified into dry and wet type; however, dry AMD is more common in aging population. AMD is characterized by drusen, yellow pigmentation, and neovascularization. These lesions are examined through visual inspection of retinal fundus images by ophthalmologists. It is laborious, time-consuming, and resource-intensive. Hence, in this study, we have proposed an automated AMD detection system using discrete wavelet transform (DWT) and feature ranking strategies. The first four-order statistical moments (mean, variance, skewness, and kurtosis), energy, entropy, and Gini index-based features are extracted from DWT coefficients. We have used five (t test, Kullback-Lieber Divergence (KLD), Chernoff Bound and Bhattacharyya Distance, receiver operating characteristics curve-based, and Wilcoxon) feature ranking strategies to identify optimal feature set. A set of supervised classifiers namely support vector machine (SVM), decision tree, [Formula: see text]-nearest neighbor ([Formula: see text]-NN), Naive Bayes, and probabilistic neural network were used to evaluate the highest performance measure using minimum number of features in classifying normal and dry AMD classes. The proposed framework obtained an average accuracy of 93.70%, sensitivity of 91.11%, and specificity of 96.30% using KLD ranking and SVM classifier. We have also formulated an AMD Risk Index using selected features to classify the normal and dry AMD classes using one number. The proposed system can be used to assist the clinicians and also for mass AMD screening programs.


Assuntos
Sistemas Inteligentes/instrumentação , Degeneração Macular/diagnóstico , Software , Análise de Ondaletas , Idoso , Idoso de 80 Anos ou mais , Teorema de Bayes , Fundo de Olho , Humanos , Processamento de Imagem Assistida por Computador , Pessoa de Meia-Idade , Curva ROC , Sensibilidade e Especificidade , Máquina de Vetores de Suporte
16.
Comput Biol Med ; 53: 55-64, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25127409

RESUMO

Age-related Macular Degeneration (AMD) is one of the major causes of vision loss and blindness in ageing population. Currently, there is no cure for AMD, however early detection and subsequent treatment may prevent the severe vision loss or slow the progression of the disease. AMD can be classified into two types: dry and wet AMDs. The people with macular degeneration are mostly affected by dry AMD. Early symptoms of AMD are formation of drusen and yellow pigmentation. These lesions are identified by manual inspection of fundus images by the ophthalmologists. It is a time consuming, tiresome process, and hence an automated diagnosis of AMD screening tool can aid clinicians in their diagnosis significantly. This study proposes an automated dry AMD detection system using various entropies (Shannon, Kapur, Renyi and Yager), Higher Order Spectra (HOS) bispectra features, Fractional Dimension (FD), and Gabor wavelet features extracted from greyscale fundus images. The features are ranked using t-test, Kullback-Lieber Divergence (KLD), Chernoff Bound and Bhattacharyya Distance (CBBD), Receiver Operating Characteristics (ROC) curve-based and Wilcoxon ranking methods in order to select optimum features and classified into normal and AMD classes using Naive Bayes (NB), k-Nearest Neighbour (k-NN), Probabilistic Neural Network (PNN), Decision Tree (DT) and Support Vector Machine (SVM) classifiers. The performance of the proposed system is evaluated using private (Kasturba Medical Hospital, Manipal, India), Automated Retinal Image Analysis (ARIA) and STructured Analysis of the Retina (STARE) datasets. The proposed system yielded the highest average classification accuracies of 90.19%, 95.07% and 95% with 42, 54 and 38 optimal ranked features using SVM classifier for private, ARIA and STARE datasets respectively. This automated AMD detection system can be used for mass fundus image screening and aid clinicians by making better use of their expertise on selected images that require further examination.


Assuntos
Técnicas de Diagnóstico Oftalmológico , Interpretação de Imagem Assistida por Computador/métodos , Degeneração Macular/diagnóstico , Algoritmos , Bases de Dados Factuais , Fundo de Olho , Humanos , Modelos Estatísticos , Análise de Ondaletas
20.
Am J Obstet Gynecol ; 122(5): 642-9, 1975 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-1146929

RESUMO

This study was undertaken to investigate the effect of daily ingestion of 0.5 mg. of lynestrenol on some parameters of the hypothalamic-pituitary-ovarian axis. Daily plasma concentrations of follicle-stimulating hormone (FSH), luteinizing hormone (LH), estradiol-17-beta (estradiol; E2-17beta), and progesterone (P) were determined by specific radioimmunoassays during one control and one treatment cycle of seven normally ovulating women. One of the volunteers was followed throughout 84 days of treatment. The following changes were observed during medication: (1) the midcycle FSH/LH peak was abolished, with a trend toward reduced LH values during the second half of the treatment cycles; (2) progesterone was significantly, though variably, reduced whereas estradiol showed little difference between control and treatment cycles; (3) during prolonged treatment two difference cyclic response patterns were observed in the same individual. It is concluded that daily administration of 0.5 mg. of lynestrenol exerts a profound effect at the central level, which contributes to the satisfactory contraceptive efficacy of this compound. A hypothetic blockade of estradiol receptors at the pituitary and/or hypothalamic level is discussed.


Assuntos
Sistema Hipotálamo-Hipofisário/efeitos dos fármacos , Linestrenol/farmacologia , Ovário/efeitos dos fármacos , Adulto , Fenômenos Químicos , Química , Anticoncepcionais Orais Sintéticos/farmacologia , Estradiol/sangue , Feminino , Hormônio Foliculoestimulante/sangue , Humanos , Sistema Hipotálamo-Hipofisário/fisiologia , Hormônio Luteinizante/sangue , Linestrenol/administração & dosagem , Menstruação , Noretindrona , Norgestrel , Ovário/fisiologia , Gravidez , Progesterona/sangue , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...