1.
Rev Sci Instrum ; 91(3): 033903, 2020 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-32260020

RESUMO

In this study, we describe an advanced multi-functional, variable-energy positron beam system capable of measuring the energies of multiple "positron-induced" electrons in coincidence with the Doppler-shifted gamma photon resulting from the annihilation of the correlated positron. The measurements were carried out using the unique characteristics of the digital time-of-flight spectrometer and the gamma spectrometer available with the advanced positron beam system. These measurements have resulted in (i) the first digital time-of-flight spectrum of positron annihilation-induced Auger electrons generated using coincident signals from a high-purity Ge detector and a micro-channel plate, (ii) a two-dimensional array of the energy of Doppler-broadened annihilation gamma and the time-of-flight of positron-annihilation induced Auger electrons/secondary electrons measured in coincidence with the annihilation gamma photon, and (iii) the time-of-flight spectra of multiple secondary electrons ejected from a bilayer graphene surface as a result of the impact and/or annihilation of positrons. The novelty of the gamma-electron coincidence spectroscopy has been demonstrated by extracting the Doppler-broadened spectrum of gamma photons emitted due to the annihilation of positrons exclusively with 1s electrons of carbon. The width of the extracted Doppler-broadened gamma spectrum has been found to be consistent with the expected broadening of the annihilation gamma spectrum due to the momentum of the 1s electrons in carbon.

2.
Rev Sci Instrum ; 87(3): 035114, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27036826

RESUMO

We describe a novel spectrometer designed for positron annihilation induced Auger electron spectroscopy employing a time-of-flight spectrometer. The spectrometer's new configuration enables us to implant monoenergetic positrons with kinetic energies as low as 1.5 eV on the sample while simultaneously allowing for the detection of electrons emitted from the sample surface at kinetic energies ranging from ∼500 eV to 0 eV. The spectrometer's unique characteristics made it possible to perform (a) first experiments demonstrating the direct transition of a positron from an unbound scattering state to a bound surface state and (b) the first experiments demonstrating that Auger electron spectra can be obtained down to 0 eV without the beam induced secondary electron background obscuring the low energy part of the spectra. Data are presented which show alternative means of estimating positron surface state binding energy and background-free Auger spectra.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...