1.
Dimens Crit Care Nurs ; 39(1): 4-11, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31789980

RESUMO

BACKGROUND: As of December 31, 2016, in the United States, 22 866 patients received left ventricular assist devices (LVADs) (J Heart Lung Transplant. 2017;36(10):1080-1086). First responders are generally unfamiliar with LVAD equipment functionality (J Heart Lung Transplant. 2018;37(4):S275). When a patient has an emergency either clinically or with a controller alarm or failure, speaking with ventricle assist device (VAD)-trained personnel is imperative to the prevention of adverse events. Starting February 2017, an LVAD program totaling 181 patients at a large teaching hospital changed their afterhours process to reduce wait time between patient call and talking to VAD-trained personnel to increase patient safety and patient satisfaction. METHODS: The Plan-Do-Check-Act quality improvement method was used to evaluate this project from February 2017 to July 2018 by the program's clinical information analyst. An afterhours summary of telephone interactions between VAD program clinicians (VAD coordinators, physician assistants, and nurse practitioner) was used to analyze the use of the "VAD Emergency Line." An annual patient satisfaction survey was completed to analyze patient satisfaction of the VAD Emergency Line. INTERVENTIONS: Review of the afterhours summary was conducted to determine the use of the VAD Emergency Line. The process of afterhours patient calls was changed so that calls are answered immediately by a 24-hour LVAD-trained medical ambulance service, called VAD Emergency Line. Patient use of the VAD Emergency Line was continuously assessed. In November 2017, it was recognized that only 57% of patient calls used the VAD Emergency Line, and further intervention was needed. In November 2017, patients were provided visual reminders to ensure compliance. RESULTS: Seventeen months after the implementation of the VAD Emergency Line, 92% of patient's afterhours calls were through the VAD Emergency Line. Although there was no statistical significance found, there was clinical significance. Since the implementation of the VAD Emergency Line, patient use of the VAD Emergency Line increased 56% from March 2017 to July 2018. There have been zero adverse safety events. Sixty-one percent of patients strongly agreed to the question "You are able to communicate emergent needs after hours (VAD Emergency Line)? CONCLUSION: Implementation of the LVAD Emergency Line has improved communication between patients in the outpatient setting. This increased patient safety by allowing patients to speak to LVAD-trained first responders and VAD coordinator personnel immediately without ever being put on hold. This communication process can be applied to other clinical programs.


Assuntos
Plantão Médico/normas , Comunicação , Serviços Médicos de Emergência/normas , Insuficiência Cardíaca/terapia , Coração Auxiliar , Melhoria de Qualidade , Algoritmos , Hospitais Universitários , Humanos , Educação de Pacientes como Assunto , Segurança do Paciente , Satisfação do Paciente , Análise de Causa Fundamental
3.
Prog Transplant ; 29(1): 67-72, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30518310

RESUMO

BACKGROUND: A mixed-method study of role stress and work intensity among nurse practitioners (NPs) in mechanical circulatory support (MCS) programs in the United States reported a qualitative data related to burnout. We empirically investigated this phenomenon by pursuing the following specific aims: (1) describe levels of personal burnout (PB), work-related (WB) burnout, and client-related burnout (CB) and quality of work life (QOWL) among MCS-NPs; (2) determine the relationship between burnout and QOWL variables; and (3) identify which type of burnout is a predictor of QOWL. METHODS: We employed an exploratory correlational research design. Demographics, work characteristics, and psychometrically robust measures of burnout and QOWL were completed by 47 MCS-NPs from various regions of the United States. Data were analyzed with descriptive and inferential statistics. RESULTS: Higher levels of burnout (PB, WB, and CB) were associated with lower levels of QOWL (r = -.52 to -.64, P < .001). Of the 3 types of burnout, WB burnout showed a significant predictor of QOWL (R2 = .44, P < .01). Multiple regression models showed that a 1 point increase in mean score of WB would decrease a mean QOWL score by 0.64 after controlling the effect of PB and CB. Some dimensions of QOWL were associated with work/hospital characteristics (r > -.30, P values <.05). CONCLUSION: Work-related burnout is negatively associated with low QOWL among NPs. Hospital/work environment was contributing factors to high burnout and low QOWL. Further research is needed to confirm the findings including the effect of burnout and QOWL on patient and ventricular assist device program outcomes.


Assuntos
Esgotamento Profissional , Transplante de Coração , Coração Auxiliar , Profissionais de Enfermagem/psicologia , Recursos Humanos de Enfermagem Hospitalar/psicologia , Adulto , Feminino , Hospitais Universitários , Humanos , Masculino , Qualidade de Vida , Inquéritos e Questionários , Estados Unidos
SELEÇÃO DE REFERÊNCIAS