Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 115
Filtrar
1.
Cancer Treat Rev ; 127: 102748, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38703593

RESUMO

Clinical trials of prostate-specific membrane antigen (PSMA) targeted radiopharmaceuticals have shown encouraging results. Some agents, like lutetium-177 [177Lu]Lu-PSMA-617 ([177Lu]Lu-PSMA-617), are already approved for late line treatment of metastatic castration-resistant prostate cancer (mCRPC). Projections are for continued growth of this treatment modality; [177Lu]Lu-PSMA-617 is being studied both in earlier stages of disease and in combination with other anti-cancer therapies. Further, the drug development pipeline is deep with variations of PSMA-targeting radionuclides, including higher energy alpha particles conjugated to PSMA-honing vectors. It is safe to assume that an increasing number of patients will be exposed to PSMA-targeted radiopharmaceuticals during the course of their cancer treatment. In this setting, it is important to better understand and mitigate the most commonly encountered toxicities. One particularly vexing side effect is xerostomia. In this review, we discuss the scope of the problem, inventories to better characterize and monitor this troublesome side effect, and approaches to preserve salivary function and effectively palliate symptoms. This article aims to serve as a useful reference for prescribers of PSMA-targeted radiopharmaceuticals, while also commenting on areas of missing data and opportunities for future research.


Assuntos
Antígenos de Superfície , Glutamato Carboxipeptidase II , Compostos Radiofarmacêuticos , Humanos , Compostos Radiofarmacêuticos/uso terapêutico , Masculino , Glutamato Carboxipeptidase II/antagonistas & inibidores , Neoplasias de Próstata Resistentes à Castração/tratamento farmacológico , Neoplasias de Próstata Resistentes à Castração/radioterapia , Lutécio/uso terapêutico , Radioisótopos/efeitos adversos , Radioisótopos/administração & dosagem , Glândulas Salivares/efeitos da radiação , Glândulas Salivares/efeitos dos fármacos , Dipeptídeos/uso terapêutico , Compostos Heterocíclicos com 1 Anel/uso terapêutico
2.
Theranostics ; 14(6): 2367-2378, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38646652

RESUMO

The field of theranostics is rapidly advancing, driven by the goals of enhancing patient care. Recent breakthroughs in artificial intelligence (AI) and its innovative theranostic applications have marked a critical step forward in nuclear medicine, leading to a significant paradigm shift in precision oncology. For instance, AI-assisted tumor characterization, including automated image interpretation, tumor segmentation, feature identification, and prediction of high-risk lesions, improves diagnostic processes, offering a precise and detailed evaluation. With a comprehensive assessment tailored to an individual's unique clinical profile, AI algorithms promise to enhance patient risk classification, thereby benefiting the alignment of patient needs with the most appropriate treatment plans. By uncovering potential factors unseeable to the human eye, such as intrinsic variations in tumor radiosensitivity or molecular profile, AI software has the potential to revolutionize the prediction of response heterogeneity. For accurate and efficient dosimetry calculations, AI technology offers significant advantages by providing customized phantoms and streamlining complex mathematical algorithms, making personalized dosimetry feasible and accessible in busy clinical settings. AI tools have the potential to be leveraged to predict and mitigate treatment-related adverse events, allowing early interventions. Additionally, generative AI can be utilized to find new targets for developing novel radiopharmaceuticals and facilitate drug discovery. However, while there is immense potential and notable interest in the role of AI in theranostics, these technologies do not lack limitations and challenges. There remains still much to be explored and understood. In this study, we investigate the current applications of AI in theranostics and seek to broaden the horizons for future research and innovation.


Assuntos
Inteligência Artificial , Neoplasias , Medicina de Precisão , Humanos , Medicina de Precisão/métodos , Medicina de Precisão/tendências , Neoplasias/diagnóstico , Neoplasias/terapia , Algoritmos , Nanomedicina Teranóstica/métodos , Nanomedicina Teranóstica/tendências
3.
Clin Nucl Med ; 49(4): e164-e165, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38377363

RESUMO

ABSTRACT: A 78-year-old man receiving bicalutamide for prostate cancer was referred for a PSMA PET/CT scan to evaluate his gradually rising prostate-specific antigen level. The PSMA PET/CT revealed gynecomastia with radiotracer uptake in bilateral breast parenchyma, a known but rarely reported effect of bicalutamide monotherapy. This scan also demonstrated metastatic progression of his disease in bone and lymph nodes, and he was started on leuprolide injections. Three months after a decrease in his testosterone level, the radiotracer uptake in his breast tissue had resolved, demonstrating that PSMA-avid bicalutamide-induced gynecomastia is reversible.


Assuntos
Anilidas , Ginecomastia , Nitrilas , Neoplasias da Próstata , Compostos de Tosil , Masculino , Humanos , Idoso , Ginecomastia/induzido quimicamente , Ginecomastia/diagnóstico por imagem , Antagonistas de Androgênios/efeitos adversos , Androgênios , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata/complicações , Neoplasias da Próstata/tratamento farmacológico
4.
BJUI Compass ; 5(2): 319-324, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38371200

RESUMO

Background: For men with prostate cancer, radiographic progression may occur without a concordant rise in prostate-specific antigen (PSA). Our study aimed to assess the prevalence of radiographic progression using C-11 choline positron emission tomography (PET) imaging in patients achieving ultra-low PSA values and to evaluate clinical outcomes in this patient population. Methods: In a single institution study, we reviewed the prospectively maintained Mayo Clinic C-11 Choline PET metastatic prostate cancer registry to identify patients experiencing radiographic disease progression (rDP) on C-11 choline PET scan while the PSA value was less than 0.5 ng/mL. Disease progression was confirmed by tissue biopsy or response to subsequent therapy. Clinicopathologic variables were abstracted by trained research personnel. Overall survival was estimated using the Kaplan-Meier method. Intergroup differences were assessed using the log-rank test. A univariate and multivariate Cox regression model was performed to investigate variables associated with poor survival after rDP. Results: A total of 1323 patients within the registry experienced rDP between 2011 and 2021, including 220 (16.6%) men with rDP occurring at low PSA level. A median (interquartile range [IQR]) of 54.7 (19.7-106.9) months elapsed between the time of prostate cancer diagnosis and low PSA rDP, during which 173 patients (78%) developed castration-resistant prostate cancer (CRPC). Sites of low PSA rDP included local recurrence (n = 17, 8%), lymph node (n = 90, 41%), bone (n = 94, 43%) and visceral metastases (n = 19, 9%). Biopsy at the time of rDP demonstrated small-cell or neuroendocrine features in 21% of patients with available tissue. Over a median (IQR) follow-up of 49.4 (21.3-95.1) months from the time of low PSA rDP, 46% (n = 102) of patients died. Factors associated with poorer survival outcomes include advanced age at rDP, CRPC status, bone and visceral metastasis (p value <0.05). Visceral metastases were associated with decreased overall survival (p = 0.009 by log-rank) as compared with other sites of rDP. Conclusions: Men with prostate cancer commonly experience metastatic progression at very low or even undetectable PSA levels. Periodic imaging, even at low absolute PSA values, may result in more timely identification of disease progression.

5.
J Clin Med ; 13(2)2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38256579

RESUMO

Major advances in prostate cancer diagnosis, staging, and management have occurred over the past decade, largely due to our improved understanding of the technical aspects and clinical applications of advanced imaging, specifically magnetic resonance imaging (MRI) and prostate-cancer-specific positron emission tomography (PET). Herein, we review the established utility of these important and exciting technologies, as well as areas of controversy and uncertainty that remain important areas for future study. There is strong evidence supporting the utility of MRI in guiding initial biopsy and assessing local disease. There is debate, however, regarding how to best use the imaging modality in risk stratification, treatment planning, and assessment of biochemical failure. Prostate-cancer-specific PET is a relatively new technology that provides great value to the evaluation of newly diagnosed, treated, and recurrent prostate cancer. However, its ideal use in treatment decision making, staging, recurrence detection, and surveillance necessitates further research. Continued study of both imaging modalities will allow for an improved understanding of their best utilization in improving cancer care.

6.
J Nucl Cardiol ; 31: 101779, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38215598

RESUMO

OBJECTIVES: The objective of this study was to determine the diagnostic performance of 15O-water positron emission tomography (PET) myocardial perfusion imaging to detect coronary artery disease (CAD) using the truth-standard of invasive coronary angiography (ICA) with fractional flow reserve (FFR) or instantaneous wave-Free Ratio (iFR) or coronary computed tomography angiogram (CCTA). BACKGROUND: 15O-water has a very high first-pass extraction that allows accurate quantification of myocardial blood flow and detection of flow-limiting CAD. However, the need for an on-site cyclotron and lack of automated production at the point of care and relatively complex image analysis protocol has limited its clinical use to date. METHODS: The RAPID WATER FLOW study is an open-label, multicenter, prospective investigation of the accuracy of 15O-water PET to detect obstructive angiographic and physiologically significant stenosis in patients with suspected CAD. The study will include the use of an automated system for producing, dosing, and injecting 15O-water and enrolling approximately 215 individuals with suspected CAD at approximately 10 study sites in North America and Europe. The primary endpoint of the study is the diagnostic sensitivity and specificity of the 15O-water PET study using the truth-standard of ICA with FFR or iFR to determine flow-limiting stenosis, or CCTA to rule out CAD and incorporating a quantitative analytic platform developed for the 15O-water PET acquisitions. Sensitivity and specificity are to be considered positive if the lower bound of the 95% confidence interval is superior to the threshold of 60% for both, consistent with prior registration studies. Subgroup analyses include assessments of diagnostic sensitivity, specificity, and accuracy in female, obese, and diabetic individuals, as well as in those with multivessel disease. All enrolled individuals will be followed for adverse and serious adverse events for up to 32 hours after the index PET scan. The study will have >90% power (one-sided test, α = 0.025) to test the hypothesis that sensitivity and specificity of 15O-water PET are both >60%. CONCLUSIONS: The RAPID WATER FLOW study is a prospective, multicenter study to determine the diagnostic sensitivity and specificity of 15O-water PET as compared to ICA with FFR/iFR or CCTA. This study will introduce several novel aspects to imaging registration studies, including a more relevant truth standard incorporating invasive physiologic indexes, coronary CTA to qualify normal individuals for eligibility, and a more quantitative approach to image analysis than has been done in prior pivotal studies. CLINICAL TRIAL REGISTRATION INFORMATION: Clinical-Trials.gov (#NCT05134012).


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Humanos , Feminino , Estudos Prospectivos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Constrição Patológica , Água , Angiografia Coronária/métodos , Perfusão , Valor Preditivo dos Testes , Imagem de Perfusão do Miocárdio/métodos , Angiografia por Tomografia Computadorizada/métodos
7.
Prostate ; 84(3): 237-244, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37899635

RESUMO

BACKGROUND: Prostate cancer (PCa) parenchymal brain metastases are uncommon and troubling observations in the course of the disease. Our study aims to evaluate the prevalence of brain metastases among PCa patients while reporting various therapeutic modalities, clinical features, and oncological outcomes. METHODS: We retrospectively identified 34 patients with parenchymal brain metastasis out of 4575 patients using a prospectively maintained database that contains clinicopathologic characteristics of PCa patients between January 2012 and December 2021. Based on the three treatment modalities used, the patients were divided into three groups: stereotactic radiosurgery (SRS), whole brain radiotherapy (WBRT), and systemic therapy alone. The Kaplan-Meier curve was used to calculate overall survival [OS] probability and the Cox proportional hazards regression model was used to compare between groups. RESULTS: At the time of brain metastasis diagnosis, the median age was 66 years, the median (interquartile range [IQR]) prostate-specific antigen (PSA) was 2.2 (0.1-26.6) ng/ml and the median (IQR) months from initial PCa diagnosis to brain metastasis development was 70.8 (27.6-100.9). The median (IQR) primary Gleason score was 8 (7-9) and over a median (IQR) follow-up time of 2.2 (1.2-16.5) months, 76.5% (n = 26) of the patients died. Thirteen (38.2%) patients had solitary lesion, whereas 21 (61.8%) had ≥2 lesions. The lesions were supratentorial in 19 (55.9%) patients, infratentorial in six (17.6%), and both sides in nine (26.5%). Among all 34 patients, 10 (29.4%) were treated with SRS, seven (20.6%) with WBRT, and 17 (50%) with systemic therapy alone. OS varied greatly between the three treatment modalities (log-rank test, p = 0.049). Those who were treated with SRS and WBRT had better OS compared with patients who were treated with systemic therapy alone (hazard ratio: 0.37, 95% confidence interval: 0.16-0.86, p = 0.022). CONCLUSIONS: In our single-institutional study, we confirmed that PCa brain metastasis is associated with poor survival outcomes and more advanced metastatic disease. Furthermore, we found that SRS and WBRT for brain metastasis in patients with recurrent PCa appear to be associated with improved OS as compared with systemic therapy alone and are likely secondary to selection bias.


Assuntos
Neoplasias Encefálicas , Neoplasias da Próstata , Radiocirurgia , Masculino , Humanos , Lactente , Estudos Retrospectivos , Resultado do Tratamento , Neoplasias Encefálicas/terapia , Neoplasias Encefálicas/secundário , Neoplasias da Próstata/cirurgia
8.
J Am Coll Radiol ; 20(11S): S455-S470, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-38040464

RESUMO

Incidental pulmonary nodules are common. Although the majority are benign, most are indeterminate for malignancy when first encountered making their management challenging. CT remains the primary imaging modality to first characterize and follow-up incidental lung nodules. This document reviews available literature on various imaging modalities and summarizes management of indeterminate pulmonary nodules detected incidentally. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Assuntos
Nódulos Pulmonares Múltiplos , Sociedades Médicas , Humanos , Diagnóstico por Imagem/métodos , Medicina Baseada em Evidências , Pulmão , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Estados Unidos
9.
Eur J Nucl Med Mol Imaging ; 50(12): 3513-3537, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37624384

RESUMO

PREAMBLE: The Society of Nuclear Medicine and Molecular Imaging (SNMMI) is an international scientific and professional organization founded in 1954 to promote the science, technology, and practical application of nuclear medicine. The European Association of Nuclear Medicine (EANM) is a professional non-profit medical association that facilitates communication worldwide between individuals pursuing clinical and research excellence in nuclear medicine. The EANM was founded in 1985. The merged International Society for Magnetic Resonance in Medicine (ISMRM) is an international, nonprofit, scientific association whose purpose is to promote communication, research, development, and applications in the field of magnetic resonance in medicine and biology and other related topics and to develop and provide channels and facilities for continuing education in the field.The ISMRM was founded in 1994 through the merger of the Society of Magnetic Resonance in Medicine and the Society of Magnetic Resonance Imaging. SNMMI, ISMRM, and EANM members are physicians, technologists, and scientists specializing in the research and practice of nuclear medicine and/or magnetic resonance imaging. The SNMMI, ISMRM, and EANM will periodically define new guidelines for nuclear medicine practice to help advance the science of nuclear medicine and/or magnetic resonance imaging and to improve the quality of service to patients throughout the world. Existing practice guidelines will be reviewed for revision or renewal, as appropriate, on their fifth anniversary or sooner, if indicated. Each practice guideline, representing a policy statement by the SNMMI/EANM/ISMRM, has undergone a thorough consensus process in which it has been subjected to extensive review. The SNMMI, ISMRM, and EANM recognize that the safe and effective use of diagnostic nuclear medicine imaging and magnetic resonance imaging requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guideline by those entities not providing these services is not authorized. These guidelines are an educational tool designed to assist practitioners in providing appropriate care for patients. They are not inflexible rules or requirements of practice and are not intended, nor should they be used, to establish a legal standard of care. For these reasons and those set forth below, the SNMMI, the ISMRM, and the EANM caution against the use of these guidelines in litigation in which the clinical decisions of a practitioner are called into question. The ultimate judgment regarding the propriety of any specific procedure or course of action must be made by the physician or medical physicist in light of all the circumstances presented. Thus, there is no implication that an approach differing from the guidelines, standing alone, is below the standard of care. To the contrary, a conscientious practitioner may responsibly adopt a course of action different from that set forth in the guidelines when, in the reasonable judgment of the practitioner, such course of action is indicated by the condition of the patient, limitations of available resources, or advances in knowledge or technology subsequent to publication of the guidelines. The practice of medicine includes both the art and the science of the prevention, diagnosis, alleviation, and treatment of disease. The variety and complexity of human conditions make it impossible to always reach the most appropriate diagnosis or to predict with certainty a particular response to treatment. Therefore, it should be recognized that adherence to these guidelines will not ensure an accurate diagnosis or a successful outcome. All that should be expected is that the practitioner will follow a reasonable course of action based on current knowledge, available resources, and the needs of the patient to deliver effective and safe medical care. The sole purpose of these guidelines is to assist practitioners in achieving this objective.

10.
Radiol Imaging Cancer ; 5(4): e220157, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37477566

RESUMO

Theranostics is the combination of two approaches-diagnostics and therapeutics-applied for decades in cancer imaging using radiopharmaceuticals or paired radiopharmaceuticals to image and selectively treat various cancers. The clinical use of theranostics has increased in recent years, with U.S. Food and Drug Administration (FDA) approval of lutetium 177 (177Lu) tetraazacyclododecane tetraacetic acid octreotate (DOTATATE) and 177Lu-prostate-specific membrane antigen vector-based radionuclide therapies. The field of theranostics has imminent potential for emerging clinical applications. This article reviews critical areas of active clinical advancement in theranostics, including forthcoming clinical trials advancing FDA-approved and emerging radiopharmaceuticals, approaches to dosimetry calculations, imaging of different radionuclide therapies, expanded indications for currently used theranostic agents to treat a broader array of cancers, and emerging ideas in the field. Keywords: Molecular Imaging, Molecular Imaging-Cancer, Molecular Imaging-Clinical Translation, Molecular Imaging-Target Development, PET/CT, SPECT/CT, Radionuclide Therapy, Dosimetry, Oncology, Radiobiology © RSNA, 2023.


Assuntos
Neoplasias , Medicina de Precisão , Estados Unidos , Masculino , Humanos , Compostos Radiofarmacêuticos/uso terapêutico , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Radioisótopos/uso terapêutico , Neoplasias/diagnóstico por imagem , Neoplasias/terapia
11.
Int J Mol Sci ; 24(14)2023 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-37511386

RESUMO

Radiopharmaceuticals are rapidly developing as a field, with the successful use of targeted beta emitters in neuroendocrine tumors and prostate cancer serving as catalysts. Targeted alpha emitters are in current development for several potential oncologic indications. Herein, we review the three most prevalently studied conjugated/chelated alpha emitters (225actinium, 212lead, and 211astatine) and focus on contemporary clinical trials in an effort to more fully appreciate the breadth of the current evaluation. Phase I trials targeting multiple diseases are now underway, and at least one phase III trial (in selected neuroendocrine cancers) is currently in the initial stages of recruitment. Combination trials are now also emerging as alpha emitters are integrated with other therapies in an effort to create solutions for those with advanced cancers. Despite the promise of targeted alpha therapies, many challenges remain. These challenges include the development of reliable supply chains, the need for a better understanding of the relationships between administered dose and absorbed dose in both tissue and tumor and how that predicts outcomes, and the incomplete understanding of potential long-term deleterious effects of the alpha emitters. Progress on multiple fronts is necessary to bring the potential of targeted alpha therapies into the clinic.


Assuntos
Neoplasias da Próstata , Compostos Radiofarmacêuticos , Humanos , Masculino , Partículas alfa/uso terapêutico , Neoplasias da Próstata/tratamento farmacológico , Compostos Radiofarmacêuticos/farmacologia , Ensaios Clínicos como Assunto
12.
Medicine (Baltimore) ; 102(6): e32665, 2023 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-36820562

RESUMO

Evaluate the quantitative, subjective (Deauville score [DS]) and reader agreement differences between standard ordered subset expectation maximization (OSEM) and Bayesian penalized likelihood (BPL) positron emission tomography (PET) reconstruction methods. A retrospective review of 104 F-18 fluorodeoxyglucose PET/computed tomography (CT) exams among 52 patients with diffuse large B-cell lymphoma. An unblinded radiologist moderator reviewed both BPL and OSEM PET/CT exams. Four blinded radiologists then reviewed the annotated cases to provide a visual DS for each annotated lesion. Significant (P < .001) differences in BPL and OSEM PET methods were identified with greater standard uptake value (SUV) maximum and SUV mean for BPL. The DS was altered in 25% of cases when BPL and OSEM were reviewed by the same radiologist. Interobserver DS agreement was higher for OSEM (>1 cm lesion = 0.89 and ≤1 cm lesion = 0.84) compared to BPL (>1 cm lesion = 0.85 and ≤1 cm lesion = 0.81). Among the 4 readers, average intraobserver visual DS agreement between OSEM and BPL was 0.67 for lesions >1cm and 0.4 for lesions ≤1 cm. F-18 Fluorodeoxyglucose PET/CT of diffuse large B-cell lymphoma reconstructed with BPL has higher SUV values, altered DSs and reader agreement when compared to OSEM. This report finds volumetric PET measurements such as metabolic tumor volume to be similar between BPL and OSEM PET reconstructions. Efforts such as adoption of European Association Research Ltd accreditation should be made to harmonize PET data with an aim at balancing the need for harmonization and sensitivity for lesion detection.


Assuntos
Linfoma Difuso de Grandes Células B , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Teorema de Bayes , Benchmarking , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Fluordesoxiglucose F18 , Algoritmos , Linfoma Difuso de Grandes Células B/diagnóstico por imagem
13.
Surgery ; 173(1): 117-123, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36229257

RESUMO

BACKGROUND: Focused parathyroidectomy in primary hyperparathyroidism is possible with accurate preoperative localization. A growing body of data exists regarding the role of radio-labeled C11 choline positron emission tomography/computed tomography. In cases of nonlocalized disease, it may be a useful adjunct to ultrasound, (123)I/(99)Tc-sestamibi (I-123 sestamibi), or 4-dimensional computed tomography imaging. METHODS: Patients who received a neck and chest limited coverage C11 choline positron emission tomography/computed tomography for evaluation of primary hyperparathyroidism from 2017 to 2021 at a single institution were retrospectively reviewed. We assessed the sensitivity, positive predictive value, and false negative rate. We also compared these rates to the standard modalities of ultrasound, I-123 sestamibi, 4-dimensional computed tomography, and examined concordance rates. RESULTS: We identified 43 patients, of whom 33 had a positive C11 choline positron emission tomography/computed tomography finding. This cohort of patients had failed to localize on multiple standard imaging modalities. Twenty-five patients proceeded to surgery, 72% of whom were reoperative cases. Twenty (80%) achieved an intraoperative cure. Analysis showed that C11 choline positron emission tomography/computed tomography achieved a sensitivity of 64% (95% confidence interval 47%-82%) and positive predictive value of 72% (95% confidence interval 54%-90%). There were 5/25 (20%) false positive positron emission tomography C11 choline results found to be lymph nodes, normal parathyroid, and 1 recurrent laryngeal nerve neuroma. CONCLUSION: C11 choline positron emission tomography/computed tomography is a useful adjunct for parathyroid localization in a complex population of patients who have failed standard localization techniques including ultrasound, I-123 sestamibi, or 4-dimensional computed tomography and/or prior operations. Although routine inclusion of C11 choline positron emission tomography/computed tomography imaging may not be necessary, it may aid in preoperative localization in the reoperative setting.


Assuntos
Colina , Hiperparatireoidismo Primário , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Hiperparatireoidismo Primário/diagnóstico por imagem , Hiperparatireoidismo Primário/cirurgia , Tecnécio Tc 99m Sestamibi , Estudos Retrospectivos , Glândulas Paratireoides/diagnóstico por imagem , Glândulas Paratireoides/cirurgia , Compostos Radiofarmacêuticos , Tomografia por Emissão de Pósitrons
14.
J Nucl Med Technol ; 51(1): 57-59, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36351799

RESUMO

Metabolic tumor volume (MTV) is defined as the total metabolically active tumor volume seen on 18F-FDG PET/CT examinations. Calculating MTV is often time-consuming, requiring a high degree of manual input. In this study, the MTV calculations of a board-certified nuclear radiologist were compared with those of 2 nuclear medicine technologists. As part of the technologists' educational program, after their classroom time they were trained by the radiologist for 30 min. The technologists calculated MTV within 7.5% of the radiologist's calculations in a set of patients who had diffuse large B-cell lymphoma and were undergoing initial staging 18F-FDG PET/CT. These findings suggest that nuclear medicine technologists may help accelerate implementation of MTV into clinical practice with favorable accuracy, possibly as an initial step followed by validation by the interpreting physician. The aim of this study was to explore whether efficiency is improved by integrating nuclear medicine technologists into a semiautomated workflow to calculate total MTV.


Assuntos
Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Fluordesoxiglucose F18 , Carga Tumoral , Tomografia por Emissão de Pósitrons , Prognóstico , Estudos Retrospectivos , Compostos Radiofarmacêuticos
15.
BJR Case Rep ; 8(3): 20210222, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36101727

RESUMO

Metastatic neuroendocrine tumour (NET) to brain has been reported in 1.5-5% of patients with NETs. Differentiation between intracranial NET metastasis and meningiomas can cause a diagnostic dilemma. We present a symptomatic case of a 66-year-old male with a history of left-sided skull base mass. The diagnosis of a meningioma was made based on the MRI findings and clinical presentation. The patient received radiation and the mass remained stable on serial MRI images at follow-up visits. Five years after his initial presentation, the patient's mass showed further growth. He also complained of worsening of his recent diagnosis of irritable bowel syndrome and fluctuations in his blood pressure. Surgical resection was performed, and histopathological features were consistent with moderately differentiated neuroendocrine tumour. Further evaluation with 68 Gallium-DOTATATE positron emission-computed tomography (Ga-68 PET/CT) showed metastatic disease involving the bones, lymph nodes, and liver without convincing evidence of the location of primary malignancy within the bowel loops or the pancreas. The patient was started on combination of capecitabine and temozolomide with partial response and significant improvement of his symptoms. This case highlights the clinical and radiological behaviour of intracranial NET that can mimic the diagnosis of meningioma.

16.
J Thorac Dis ; 14(4): 939-951, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35572874

RESUMO

Background: Percutaneous ablation is an alternative treatment for lung cancer in non-operable patients. This is a prospective clinical trial for percutaneous microwave ablation (pMWA) of biopsy-proven lung cancer to demonstrate safety and efficacy. Methods: A prospective trial from 6-1-2016 to 1-1-2019 enrolled patients with biopsy-proven primary or metastatic lung cancer <3 cm in size and 1 cm away from the pleura for pMWA with the Emprint Ablation System with Thermosphere Technology for Phase I analysis, (Clinicaltrials.gov; #NCT0267302). Patients were followed for 1 year with PET/CT and PET/MR to determine patterns of recurrence and efficacy of ablation. Results: After 12 patients consented for biopsy, 6 patients underwent treatment of 7 lesions, 3/6 women, median age of 67 (IQR, 65-70) years, body mass index (BMI): 27.8 (IQR, 21.4-32.1) kg/m2, lesion distance to pleura 24.4 (IQR, 13-38) mm, lesion size of 10.7 (IQR, 6-14) mm, and ablation duration time 5.9 (IQR, 3-10) minutes. pMWA were completed at 75 W. Twelve adverse events were reported (1 Grade 3, 3 Grade 2, and 8 Grade 1 events) with Grade 4 or 5 events. Mean % change after ablation in forced expiratory volume in one second (FEV1) was -2% and diffusion capacity for carbon monoxide (DLCO) was -1%. After 2-3 months, the lesions would decrease in size, rim thickness, fluorodeoxyglucose (FDG) activity, and T2 signal. FDG activity after 6 months was below blood pool in all cases. The ablation zones stabilized by 6-12 months. One patient expired during the study from pneumonia unrelated to ablation without local recurrence. Of the seven ablations during the 1 year follow-up, there was local tumor recurrence at 271 days following ablation at the apex of the ablation zone, subsequently successfully treated with percutaneous cryoablation (Cryo). Conclusions: pMWA appears to be a safe and effective mechanism for treatment of primary and secondary tumors of the lung, with possible preservation of pulmonary function.

17.
Abdom Radiol (NY) ; 47(12): 4058-4072, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35426497

RESUMO

Advanced molecular imaging has come to play an integral role in the management of gastro-entero-pancreatic neuroendocrine neoplasms (GEP-NENs). Somatostatin receptor (SSTR) PET has now emerged as the reference standard for the evaluation of NENs and is particularly critical in the context of peptide receptor radionuclide therapy (PRRT) eligibility. SSTR PET/MRI with liver-specific contrast agent has a strong potential for one-stop-shop multiparametric evaluation of GEP-NENs. 18F-FDG is a complementary radiotracer to SSTR, especially in the context of high-grade neuroendocrine neoplasms. Knowledge gaps in quantitative evaluation of molecular imaging studies and their role in assessment of response to PRRT and combination therapies are active research areas. Novel radiotracers have the potential to overcome existing limitations in the molecular imaging of GEP-NENs. The purpose of this article is to provide an overview of the current trends, pitfalls, and recent advancements of molecular imaging for GEP-NENs.


Assuntos
Tumores Neuroendócrinos , Neoplasias Pancreáticas , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Receptores de Somatostatina , Tomografia por Emissão de Pósitrons , Imageamento por Ressonância Magnética
18.
Front Oncol ; 12: 823667, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35198446

RESUMO

Somatostatin receptor 2 (SSTR2) has been shown to be expressed in a subset of neuroendocrine tumors and carcinomas and plays a role in imaging studies and guiding therapy. Patients with tumors expressing SSTR2 may be successfully treated with somatostatin inhibitors or radiolabeled somatostatin analogues. We studied SSTR2 expression in TET and correlated it with 68Ga-DOTATATE PET/CT or 68Ga-DOTATATE PET/MR results and treatment outcome. An institutional database of TET was searched for thymoma, thymic carcinoma, and thymic neuroendocrine tumor (TNET) with available resection specimens. Cases were subtyped (2021 WHO classification) and staged (8th AJCC/UICC staging). A section was stained with anti-SSTR2 antibody (clone UMB1). Percent tumor cells with membranous staining was recorded if present in ≥1% of tumor cells. Medical records were searched for 68Ga-DOTATATE PET scans and treatment. Statistical analysis was performed. Eighty patients (1969-2021) with a median age of 61.3 years (range, 19.1-87.3) (37 males, 46.3%) had thymic carcinoma (N=33), TNET (N=7), or thymoma (N=40). SSTR2 expression was identified in 29 (of 80, 36.3%) TET including 2/2 (100%) small cell carcinomas, 2/5 (40.0%) atypical carcinoid tumors, 16/23 (69.6%) squamous cell carcinomas, 2/2 (100%) lymphoepithelial carcinomas, 1/1 (100%) adenosquamous carcinoma, and 6/40 (15.0%) thymomas. SSTR2 expression in ≥50% of tumor cells (vs 1-49%) was associated with younger age (p=0.023) and shorter recurrence/metastasis-free survival (p=0.007). 68Ga-DOTATATE PET scans (N=9) revealed a Krenning score of 3 in patients with atypical carcinoid tumor, small cell carcinoma, and squamous cell carcinoma (N=1 each) with SSTR2 expression in 95, 100, and 5% of tumor cells, respectively. Scans with Krenning scores of ≤2 (N=5) were seen in tumors with no SSTR2 expression in 80% of cases and a single atypical carcinoid tumor with SSTR2 expression in 10% of tumor cells. One scan resulted as "increased uptake" was in a patient with no SSTR2 expression. In conclusion, 68Ga-DOTATATE PET scans correlated with SSTR2 expression in TET in most patients and appeared to be useful to identify patients with TET who may be amenable to treatment with somatostatin analogues. Larger studies including more patients with 68Ga-DOTATATE PET scans are necessary to independently and prospectively validate our findings.

19.
Pharm Res ; 39(1): 153-165, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34988780

RESUMO

PURPOSE: GSK2982772 is a selective inhibitor of receptor-interacting protein kinase-1 (RIPK1) with a short 2- to 3-h half-life. In a previous modified-release (MR) study, a matrix monolithic formulation (80% GSK2982772 released over 12 h) provided a once-daily (QD) pharmacokinetic (PK) profile in the fasted state; however, it was susceptible to food effects. The current study evaluated the safety and PK of MR formulations using GSK proprietary DiffCORE™ technology. METHODS: Part A evaluated PK following single-dose (240 mg) fasted and fed (high-fat meal) administration of three DiffCORE MR formulations within pre-defined in vitro extremes of 80% GSK2982772 released over 12 h (MR-12 h) to 80% GSK2982772 released over 18 h (MR-18 h) versus an immediate-release formulation. Part B evaluated MR-16 h (120-960 mg) in different prandial states. RESULTS: Pharmacokinetic profiles for all MR formulations and doses tested in the fasted and fed states were consistent with QD dosing. CONCLUSIONS: The DiffCORE technology overcame the food effect vulnerability observed with the matrix monolithic formulation. The MR-16 h formulation was selected for further clinical development as a QD dosing regimen (NCT03649412 September 26, 2018).


Assuntos
Oxazepinas , Área Sob a Curva , Estudos Cross-Over , Preparações de Ação Retardada , Meia-Vida , Oxazepinas/farmacocinética , Tecnologia , Triazóis
20.
AJR Am J Roentgenol ; 218(1): 141-150, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34346785

RESUMO

PET with targeted radiotracers has become integral to mapping the location and burden of recurrent disease in patients with biochemical recurrence (BCR) of prostate cancer (PCa). PET with 11C-choline is part of the National Comprehensive Cancer Network and European Association of Urology guidelines for evaluation of BCR. With advances in PET technology, increasing use of targeted radiotracers, and improved survival of patients with BCR because of novel therapeutics, atypical sites of metastases are being increasingly encountered, challenging the conventional view that prostate cancer rarely metastasizes beyond bones or lymph nodes. The purpose of this article is to describe such atypical metastases in the abdomen and pelvis on 11C-choline PET (including metastases to the liver, pancreas, genital tract, urinary tract, peritoneum, abdominal wall, and perineural spread) and to present multimodality imaging features and relevant imaging pitfalls. Given atypical metastases' inconsistent relationship with the serum PSA level and the nonspecific presenting symptoms, atypical metastases are often first detected on imaging. Awareness of their imaging features is important because their detection affects clinical management, patient counseling, prognosis, and clinical trial eligibility. Such awareness is particularly critical because the role of radiologists in the imaging and management of BCR will continue to increase given the expanding regulatory approvals of other targeted and theranostic radiotracers.


Assuntos
Neoplasias Abdominais/diagnóstico por imagem , Radioisótopos de Carbono , Colina , Segunda Neoplasia Primária/diagnóstico por imagem , Neoplasias Pélvicas/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias da Próstata/patologia , Cavidade Abdominal/diagnóstico por imagem , Neoplasias Abdominais/secundário , Humanos , Masculino , Imagem Multimodal , Neoplasias Pélvicas/secundário , Pelve/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...