Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Sci (Weinh) ; 11(11): e2306824, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38191978

RESUMO

Protein complexes are essential for proteins' folding and biological function. Currently, native analysis of large multimeric protein complexes remains challenging. Structural biology techniques are time-consuming and often cannot monitor the proteins' dynamics in solution. Here, a capillary electrophoresis-mass spectrometry (CE-MS) method is reported to characterize, under near-physiological conditions, the conformational rearrangements of ∽1 MDa GroEL upon complexation with binding partners involved in a protein folding cycle. The developed CE-MS method is fast (30 min per run), highly sensitive (low-amol level), and requires ∽10 000-fold fewer samples compared to biochemical/biophysical techniques. The method successfully separates GroEL14 (∽800 kDa), GroEL7 (∽400 kDa), GroES7 (∽73 kDa), and NanA4 (∽130 kDa) oligomers. The non-covalent binding of natural substrate proteins with GroEL14 can be detected and quantified. The technique allows monitoring of GroEL14 conformational changes upon complexation with (ATPγS)4-14 and GroES7 (∽876 kDa). Native CE-pseudo-MS3 analyses of wild-type (WT) GroEL and two GroEL mutants result in up to 60% sequence coverage and highlight subtle structural differences between WT and mutated GroEL. The presented results demonstrate the superior CE-MS performance for multimeric complexes' characterization versus direct infusion ESI-MS. This study shows the CE-MS potential to provide information on binding stoichiometry and kinetics for various protein complexes.


Assuntos
Dobramento de Proteína , Proteínas , Conformação Proteica , Eletroforese Capilar , Espectrometria de Massas
2.
Trends Analyt Chem ; 1652023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37388554

RESUMO

Tissues and other cell populations are highly heterogeneous at the cellular level, owing to differences in expression and modifications of proteins, polynucleotides, metabolites, and lipids. The ability to assess this heterogeneity is crucial in understanding numerous biological phenomena, including various pathologies. Traditional analyses apply bulk-cell sampling, which masks the potentially subtle differences between cells that can be important in understanding of biological processes. These limitations due to cell heterogeneity inspired significant efforts and interest toward the analysis of smaller sample sizes, down to the level of individual cells. Among the emerging techniques, the unique capabilities of capillary electrophoresis coupled with mass spectrometry (CE-MS) made it a prominent technique for proteomics and metabolomics analysis at the single-cell level. In this review, we focus on the application of CE-MS in the proteomic and metabolomic profiling of single cells and highlight the recent advances in sample preparation, separation, MS acquisition, and data analysis.

3.
Anal Chem ; 94(41): 14358-14367, 2022 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-36194750

RESUMO

Proteomic analysis of limited samples and single cells requires specialized methods that prioritize high sensitivity and minimize sample loss. Consequently, sample preparation is one of the most important steps in limited sample analysis workflows to prevent sample loss. In this work, we have eliminated sample handling and transfer steps by processing intact cells directly in the separation capillary, online with capillary electrophoresis coupled to tandem mass spectrometry (CE-MS/MS) for top-down proteomic (TDP) analysis of low numbers of mammalian cancer cells (<10) and single cells. We assessed spray voltage injection of intact cells from a droplet of cell suspension (∼1000 cells) and demonstrated 0-9 intact cells injected with a dependency on the duration of spray voltage application. Spray voltage applied for 2 min injected an average of 7 ± 2 cells and resulted in 33-57 protein and 40-88 proteoform identifications (N = 4). To analyze single cells, manual cell loading by hydrodynamic pressure was used. Replicates of single HeLa cells (N = 4) lysed on the capillary and analyzed by CE-MS/MS demonstrated a range of 17-40 proteins and 23-50 proteoforms identified. An additional cell line, THP-1, was analyzed at the single-cell level, and proteoform abundances were compared to show the capabilities of single-cell TDP (SC-TDP) for assessing cellular heterogeneity. This study demonstrates the initial application of TDP in single-cell proteome-level profiling. These results represent the highest reported identifications from TDP analysis of a single HeLa cell and prove the tremendous potential for CE-MS/MS on-capillary sample processing for high sensitivity analysis of single cells and limited samples.


Assuntos
Proteômica , Espectrometria de Massas em Tandem , Animais , Proteínas de Ligação a DNA , Células HeLa , Humanos , Mamíferos , Proteoma/análise , Proteômica/métodos , Espectrometria de Massas em Tandem/métodos
4.
J Proteome Res ; 21(10): 2453-2461, 2022 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-36112031

RESUMO

In this work, we pioneered the assessment of coupling high-field asymmetric waveform ion mobility spectrometry (FAIMS) with ultrasensitive capillary electrophoresis hyphenated with tandem mass spectrometry (CE-MS/MS) to achieve deeper proteome coverage of low nanogram amounts of digested cell lysates. An internal stepping strategy using three or four compensation voltages per analytical run with varied cycle times was tested to determine optimal FAIMS settings and MS parameters for the CE-FAIMS-MS/MS method. The optimized method applied to bottom-up proteomic analysis of 1 ng of HeLa protein digest standard identified 1314 ± 30 proteins, 4829 ± 200 peptide groups, and 7577 ± 163 peptide spectrum matches (PSMs) corresponding to a 16, 25, and 22% increase, respectively, over CE-MS/MS alone, without FAIMS. Furthermore, the percentage of acquired MS/MS spectra that resulted in PSMs increased nearly 2-fold with CE-FAIMS-MS/MS. Label-free quantitation of proteins and peptides was also assessed to determine the precision of replicate analyses from FAIMS methods with increased cycle times. Our results also identified from 1 ng of HeLa protein digest without any prior enrichment 76 ± 9 phosphopeptides, 18% of which were multiphosphorylated. These results represent a 46% increase in phosphopeptide identifications over the control experiments without FAIMS yielding 2.5-fold more multiphosphorylated peptides.


Assuntos
Espectrometria de Mobilidade Iônica , Proteômica , Eletroforese Capilar , Espectrometria de Mobilidade Iônica/métodos , Fosfopeptídeos , Proteoma , Proteômica/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos
5.
Anal Chem ; 94(2): 704-713, 2022 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-34983182

RESUMO

In this work, we developed an ultra-sensitive CE-MS/MS method for bottom-up proteomics analysis of limited samples, down to sub-nanogram levels of total protein. Analysis of 880 and 88 pg of the HeLa protein digest standard by CE-MS/MS yielded ∼1100 ± 46 and ∼160 ± 59 proteins, respectively, demonstrating higher protein and peptide identifications than the current state-of-the-art CE-MS/MS-based proteomic analyses with similar amounts of sample. To demonstrate potential applications of our ultra-sensitive CE-MS/MS method for the analysis of limited biological samples, we digested 500 and 1000 HeLa cells using a miniaturized in-solution digestion workflow. From 1-, 5-, and 10-cell equivalents injected from the resulted digests, we identified 744 ± 127, 1139 ± 24, and 1271 ± 6 proteins and 3353 ± 719, 5709 ± 513, and 8527 ± 114 peptide groups, respectively. Furthermore, we performed a comparative assessment of CE-MS/MS and two reversed-phased nano-liquid chromatography (RP-nLC-MS/MS) methods (monolithic and packed columns) for the analysis of a ∼10 ng HeLa protein digest standard. Our results demonstrate complementarity in the protein- and especially peptide-level identifications of the evaluated CE-MS- and RP-nLC-MS-based methods. The techniques were further assessed to detect post-translational modifications and highlight the strengths of the CE-MS/MS approach in identifying potentially important and biologically relevant modified peptides. With a migration window of ∼60 min, CE-MS/MS identified ∼2000 ± 53 proteins on average from a single injection of ∼8.8 ng of the HeLa protein digest standard. Additionally, an average of 232 ± 10 phosphopeptides and 377 ± 14 N-terminal acetylated peptides were identified in CE-MS/MS analyses at this sample amount, corresponding to 2- and 1.5-fold more identifications for each respective modification found by nLC-MS/MS methods.


Assuntos
Proteômica , Espectrometria de Massas por Ionização por Electrospray , Eletroforese Capilar/métodos , Células HeLa , Humanos , Fosfopeptídeos , Proteômica/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos
6.
Semin Perinatol ; 44(4): 151244, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32248956

RESUMO

This article examines approaches for improving the efficiency and effectiveness of quality metrics currently in use in neonatal care. Desirable characteristics of quality metrics are discussed, the criteria and process for their development are presented, and the uses and limitations of current neonatal outcome and process metrics are explored together with approaches for improving metric performance. Discussion includes enhancing quality metrics through optimizing improvement readiness, sustaining improvements once achieved, and use of improvement science methods to improve metric validity.


Assuntos
Unidades de Terapia Intensiva Neonatal , Neonatologia/normas , Avaliação de Processos e Resultados em Cuidados de Saúde/normas , Melhoria de Qualidade , Humanos , Recém-Nascido , Enfermagem Neonatal/normas , Avaliação de Programas e Projetos de Saúde
7.
Nat Methods ; 16(7): 587-594, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31249407

RESUMO

One gene can give rise to many functionally distinct proteoforms, each of which has a characteristic molecular mass. Top-down mass spectrometry enables the analysis of intact proteins and proteoforms. Here members of the Consortium for Top-Down Proteomics provide a decision tree that guides researchers to robust protocols for mass analysis of intact proteins (antibodies, membrane proteins and others) from mixtures of varying complexity. We also present cross-platform analytical benchmarks using a protein standard sample, to allow users to gauge their proficiency.


Assuntos
Benchmarking , Espectrometria de Massas/métodos , Proteínas/química , Desnaturação Proteica , Processamento de Proteína Pós-Traducional , Proteômica
8.
Am J Perinatol ; 35(13): 1311-1318, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29783270

RESUMO

OBJECTIVE: To reduce nonactionable oximeter alarms by 80% without increasing time infants were hypoxemic (oxygen saturation [SpO2] ≤ 80%) or hyperoxemic (SpO2 > 95% while on supplemental oxygen). STUDY DESIGN: In 2015, a multidisciplinary team at Connecticut Children's Medical Center initiated a quality improvement project to reduce nonactionable oximeter alarms in two referral neonatal intensive care units (NICUs). Changes made through improvement cycles included reduction of the low oximeter alarm limit for specific populations, increased low alarm delay, development of postmenstrual age-based alarm profiles, and updated bedside visual reminders. Manual alarm tallies and electronic SpO2 data were collected throughout the project. RESULTS: Alarm tallies were collected for 158 patient care hours with SpO2 data available for 138 of those hours. Mean number of total nonactionable alarms per patient per hour decreased from 9 to 2 (78% decrease) and the mean number of nonactionable low alarms per patient per hour decreased from 5 to 1 (80% decrease). No change was noted in the balancing measures of percentage time with SpO2 ≤ 80% (mean 4.3%) or SpO2 > 95% (mean 23.7%). CONCLUSION: Through small changes in oximeter alarm settings, including revision of alarm limits, alarm delays, and age-specific alarm profiles, our NICUs significantly reduced nonactionable alarms without increasing hypoxemia.


Assuntos
Alarmes Clínicos/normas , Unidades de Terapia Intensiva Neonatal , Oximetria , Feminino , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal/organização & administração , Unidades de Terapia Intensiva Neonatal/normas , Masculino , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Monitorização Fisiológica/normas , Oximetria/efeitos adversos , Oximetria/instrumentação , Oximetria/métodos , Oxigenoterapia/métodos , Testes Imediatos/organização & administração , Melhoria de Qualidade
9.
Clin Perinatol ; 44(3): 713-728, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28802348

RESUMO

Clinical alarm systems have received significant attention in recent years following warnings from hospital accrediting and health care technology organizations regarding patient harm caused by unsafe practices. Alarm desensitization or fatigue from frequent, false, or unnecessary alarms, has led to serious events and even patient deaths. Other concerns include settings inappropriate to patient population or condition, inadequate staff training, and improper use or disabling. Research on human factors in alarm response and of functionality of medical devices will help clinicians develop appropriate policies, practices, and device settings for clinical alarms in neonatal intensive care units.


Assuntos
Fadiga de Alarmes do Pessoal de Saúde , Alarmes Clínicos , Unidades de Terapia Intensiva Neonatal , Melhoria de Qualidade , Humanos
10.
Pediatr Res ; 80(6): 785-792, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27509008

RESUMO

BACKGROUND: We examined recent trends and interhospital variation in use of indomethacin, ibuprofen, and surgical ligation for patent ductus arteriosus (PDA) in very-low-birth-weight (VLBW) infants. METHODS: Included in this retrospective study of the Pediatric Hospital Information System database were 13,853 VLBW infants from 19 US children's hospitals, admitted at age < 3 d between 1 January 2005 and 31 December 2014. PDA management and in-hospital outcomes were examined for trends and variation. RESULTS: PDA was diagnosed in 5,719 (42%) VLBW infants. Cyclooxygenase inhibitors and/or ligation were used in 74% of infants with PDA overall, however studied hospitals varied greatly in PDA management. Odds of any cyclooxygenase inhibitor or surgical treatment for PDA decreased 11% per year during the study period. This was temporally associated with improved survival but also with increasing bronchopulmonary dysplasia, periventricular leukomalacia, retinopathy of prematurity, and acute renal failure in unadjusted analyses. There was no detectable correlation between hospital-specific changes in PDA management and hospital-specific changes in outcomes of preterm birth during the study period. CONCLUSION: Use of cyclooxygenase inhibitors and ligation for PDA in VLBW infants decreased over a 10-y period at the studied hospitals. Further evidence is needed to assess the impact of this change in PDA management.


Assuntos
Permeabilidade do Canal Arterial/tratamento farmacológico , Permeabilidade do Canal Arterial/cirurgia , Inibidores de Ciclo-Oxigenase/uso terapêutico , Bases de Dados Factuais , Feminino , Hospitais Pediátricos , Humanos , Ibuprofeno/uso terapêutico , Indometacina/uso terapêutico , Recém-Nascido , Recém-Nascido de muito Baixo Peso , Ligadura , Masculino , Estudos Retrospectivos , Resultado do Tratamento , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...