Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Spine Deform ; 11(2): 487-493, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36447049

RESUMO

PURPOSE: Magnetically controlled growing rods (MCGR) have become the dominant distraction-based implant for the treatment of early onset scoliosis (EOS). Recent studies, however, have demonstrated rising rates of implant failure beyond short-term follow-up. We sought to evaluate a single-center experience with MCGR for the treatment of EOS to define the rate of MCGR failure to lengthen, termed implant stall, over time. METHODS: A single-center, retrospective review was conducted identifying children with EOS undergoing primary MCGR implantation. The primary endpoint was the occurrence of implant stalling, defined as a failure of the MCGR to lengthen on three consecutive attempted lengthening sessions with minimum of 2 years follow-up. Clinical and radiographic variables were collected and compared between lengthening and stalled MCGRs. A Kaplan-Meier survival analysis was conducted to assess implant stalling over time. RESULTS: A total of 48 children met inclusion criteria (mean age 6.3 ± 1.8 years, 64.6% female). After a mean 56.9 months (range of 27 to 90 months) follow-up, 25 (48%) of children experienced implant stalling at a mean of 26.0 ± 14.1 months post-implantation. Kaplan-Meier survival analysis demonstrated that only 50% of MCGR continue to successfully lengthen at 2 years post-implantation, decreasing to < 20% at 4 years post-implantation. CONCLUSION: Only 50% of MCGR continue to successfully lengthen 2 years post-implantation, dropping dramatically to < 20% at 4 years, adding to the available knowledge regarding the long-term viability and cost-effectiveness of MCGR in the management of EOS. Further research is needed to validate these findings.


Assuntos
Procedimentos Ortopédicos , Escoliose , Criança , Humanos , Feminino , Pré-Escolar , Masculino , Seguimentos , Escoliose/cirurgia , Próteses e Implantes , Estudos Retrospectivos
2.
Artigo em Inglês | MEDLINE | ID: mdl-34637410

RESUMO

Osteochondral lesions of the femoral head in young people are rare and present unique management challenges. Optimal treatment for these lesions is unclear. From 2009 to 2016, clinical and radiographic outcomes were prospectively collected within a series of symptomatic focal osteochondral lesions of the femoral head with a minimum follow-up of 2 years. A surgical hip dislocation followed by implantation of a size-matched fresh osteochondral femoral head allograft was performed. Nine hips in eight patients (6 female patients) underwent surgery at an average of 17 years (11 to 21 years). Individual allograft sizes ranged from 10 to 35 mm in diameter; with 2 of 9 hips receiving two allografts in a stacked or mosaicplasty technique at the time of treatment. The average graft implantation was 3536.5 mm2. Modified Harris hip scores improved by 13.4 (P = 0.018) from preoperative to final follow-up for all patients. Significant improvements in internal rotation (12° versus 23°, P = 0.011), external rotation (32° versus 50°, P = 0.041), and abduction (28° versus 40°, P = 0.042) were also achieved. Three patients (four hips) demonstrated poor radiographic healing (<50% incorporation at 2 years), which correlated with worse clinical outcomes and was associated with a lower preoperative lateral center edge angle (21.5° versus 30.4°, P = 0.049). Fresh osteochondral allograft treatment is a good option for focal osteochondral lesions of the femoral head with improved outcomes and motion; however, higher failure rates may be seen in those with a lower center edge angle.


Assuntos
Cabeça do Fêmur , Luxação do Quadril , Acetábulo , Adolescente , Aloenxertos , Feminino , Cabeça do Fêmur/diagnóstico por imagem , Luxação do Quadril/diagnóstico por imagem , Humanos , Transplante Homólogo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...