Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Lett ; 36(4): 523-5, 2011 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-21326443

RESUMO

We report what we believe to be the first experimental demonstration of coherent beam combining of two fiber amplifiers in a 100 ns pulse regime using a signal leak between the pulses. Pulses of ∼100 W stimulated-Brillouin-scattering limited peak power are combined with 95% efficiency, a residual phase error of λ/27, and no significant beam quality degradation.

2.
Clin Microbiol Infect ; 16(9): 1368-74, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20041891

RESUMO

In order to provide a statistically based evaluation of the incidence of invasive aspergillosis (IA) over time, we applied the cumulative sums (CUSUM) methodology, which was developed for quality control and has already been applied for the surveillance of hospital-acquired infections. Cases of IA were recorded during a 5-year period. Incidence rates of cases assumed to be hospital-acquired, i.e. nosocomial IA (NIA), were analysed using CUSUM tests. Relationships between NIA, fungal contamination and construction or renovation work were tested using time-series methods. Between January 2002 and December 2006, 81 cases of NIA were recorded. CUSUM analysis of NIA incidence showed no significant deviation from the expected monthly number of cases until August 2005, and then the CUSUM crossed the decision limit, i.e. identified a significant increase in NIA as compared with the reference period (January 2002 to December 2004). Up to April 2006, the learning-curve CUSUM stayed over its limit, supporting an ongoing outbreak involving 24 patients, and then it significantly decreased in May 2006. Follow-up after May 2006 indicated no out-of-control situation, supporting a return to the baseline situation. In haematology wards, significant links were found between NIA incidence and fungal contamination of several sites at each ward (mainly unprotected common sites). An environmental source of contamination could be suspected, but no significant relationship was found between NIA incidence and ongoing construction or renovation. In conclusion, the CUSUM test proved to be well suited for real-time monitoring of NIA and for early identification and follow-up of an outbreak.


Assuntos
Aspergilose/epidemiologia , Infecção Hospitalar/epidemiologia , Surtos de Doenças , Gestão da Segurança/métodos , Vigilância de Evento Sentinela , Adulto , Aspergilose/diagnóstico , Infecção Hospitalar/diagnóstico , Humanos , Incidência
3.
Opt Lett ; 33(22): 2701-3, 2008 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-19015714

RESUMO

We report on what we believe to be the first demonstration of an erbium-ytterbium-doped multifilament-core (MFC) fiber for single-mode amplification of narrow linewidth high peak power pulses. A master-oscillator-power-fiber-amplifier laser source has been demonstrated using a 37-filament MFC fiber in the last amplification stage. Pulses with 750 microJ (940 W peak power) and laser linewidth<1 MHz have beam generated with M2 approximately 1.3. This value is close to the theoretical value M2 approximately 1.5.

4.
Opt Express ; 16(5): 3212-22, 2008 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-18542409

RESUMO

This paper reports the main characteristics of the Stokes spectra for typical pumped and unpumped Erbium-Ytterbium doped fibers. Doped fibers show shorter Brillouin shifts and their spectra are up to 1.6 times broader than undoped fibers. Those spectra are composed of several peaks originating from several longitudinal acoustic modes. The effective Brillouin gain of the secondary modes can be as large as 20% of the main peak gain. They can merge into a more complex structure for the largest cores. Simulations allow to relate these characteristics to the influence of codoping and index profile inhomogeneity. An additional broadening of the Stokes spectrum in pumped fibers is reported and attributed to thermal effects.


Assuntos
Desenho Assistido por Computador , Érbio/química , Tecnologia de Fibra Óptica/instrumentação , Lasers de Estado Sólido , Análise Espectral/métodos , Itérbio/química , Desenho de Equipamento , Análise de Falha de Equipamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...