Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-34574828

RESUMO

This paper examines how economic growth and renewable energy consumption are associated with air pollution using a dynamic panel approach. Focusing on several major air pollutants, namely, particulate matter, sulfur dioxide, nitrogen oxide, and carbon monoxide, this paper tests the environmental Kuznets hypothesis and determines whether the use of renewable energy sources contributes to a reduction in air pollution. Data from a balanced panel of 145 countries for the period between 2000 and 2014 was used for the estimation of the dynamic panel model. The results of the dynamic panel model showed inverted U-shaped curves for the relationship between economic development and particulate matter and sulfur dioxide emissions. The results also revealed that increasing renewable energy consumption contributes to an improvement in air quality. Moreover, it was found that urbanization tends to decrease sulfur dioxide and nitrogen oxide emissions, while trade openness reduces particulate matter and carbon monoxide emissions but increases sulfur dioxide emissions.


Assuntos
Poluição do Ar , Desenvolvimento Econômico , Dióxido de Carbono/análise , Energia Renovável , Urbanização
2.
Jpn J Radiol ; 36(1): 59-67, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29086347

RESUMO

PURPOSE: We aimed to develop a gap-filling algorithm, in particular the filter mask design method of the algorithm, which optimizes the filter to the imaging object by an adaptive and iterative process, rather than by manual means. METHODS: Two numerical phantoms (Shepp-Logan and Jaszczak) were used for sinogram generation. The algorithm works iteratively, not only on the gap-filling iteration but also on the mask generation, to identify the object-dedicated low frequency area in the DCT-domain that is to be preserved. We redefine the low frequency preserving region of the filter mask at every gap-filling iteration, and the region verges on the property of the original image in the DCT domain. RESULTS: The previous DCT2 mask for each phantom case had been manually well optimized, and the results show little difference from the reference image and sinogram. We observed little or no difference between the results of the manually optimized DCT2 algorithm and those of the proposed algorithm. CONCLUSIONS: The proposed algorithm works well for various types of scanning object and shows results that compare to those of the manually optimized DCT2 algorithm without perfect or full information of the imaging object.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Algoritmos , Imagens de Fantasmas
3.
J Nucl Sci Technol ; 45(7): 634-638, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19606269

RESUMO

We investigate a method to improve the position decoding for thick crystal versions (i.e., ≥8 mm) of the continuous miniature crystal element (cMiCE) PET detector by more accurately modeling the detector light response function (LRF). The LRF for continuous detectors varies with the depth of interaction (DOI) of the detected photon. This variation in LRF can result in a positioning error for two-dimensional positioning algorithms. We explore a method to improve positioning performance by deriving two lookup tables, corresponding to the front and back regions of the crystal. The DETECT2000 simulation package was used to investigate the light response characteristics for a 48.8 mm by 48.8 mm by 10 (8) mm slab of LSO coupled to a 64-channel, flat-panel PMT. The data are then combined to produce the two-dimensional light collection histograms. Light collection histograms that have markedly non-Gaussian distributions are characterized as a combination of two Gaussian functions, where each Gaussian function corresponds to a DOI region of the crystal. The results indicate that modest gains in positioning accuracy are achieved near the central region of the crystal. However, significant improvements in spatial resolution and positioning bias are achieved for the corner section of the detector.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...