Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Artigo em Coreano | WPRIM (Pacífico Ocidental) | ID: wpr-17787

RESUMO

This study was performed to investigate the influence of lateral guidance pattern and chewing pattern on masticatory muscle activity and occlusal contact pattern. Twenty-five patients with temporomandibular disorders and thirty students without temporomandibular disorders were selected for this study. Electromyographic examination and occlusal contact examination were performed simultaneously with Bio-Pak System(Bioresearch Inc.,U.S.A.) and T-Scan System(Tekscan Co., USA). The obtained results were as follows : 1. The EMG activity of masseter and anterior temporal muscle in patient group with canine guidance was higher than with non-canine guidance, but there was no significant difference(p>0.05). 2. The EMG activity of anterior temporal muscle in normal group with non-canine guidance was higher at preferred chewing side than at opposite side(p0.05). 5. The occlusal contact force at preferred chewing side was higher in patient group than in normal group(p<0.05).


Assuntos
Humanos , Oclusão Dentária , Músculo Masseter , Mastigação , Músculos da Mastigação , Músculo Temporal , Transtornos da Articulação Temporomandibular
2.
Artigo em Coreano | WPRIM (Pacífico Ocidental) | ID: wpr-191467

RESUMO

The purpose of this study was to evaluate the stress patterns developed in abutment and residual ridge according to removable denture design in case of remaining mandibular cannies The removable denture design in this study were as foolows ; 1. Removable partial denture with non-splinted abutment 2. Removable partial denture with splinted abutment 3. Overdenture with telescopic crown 4. Overdenture with O-Ring attachment 5. Overdenture with combination bar attachment Photoelastic stress analysis was used to record the isochromatic fringe patterns and to calculate principal stress components at measuring points. The results were as follows : 1. In case of removable partial denture with non-splinted abutment, stress of root area at the loaded side was the largest. No significant differences in stress of root area were observed between loaded side and unloaded side. 2. No significant differences in stress of residual ridge at the loaded side were observed between removable partial denture with splinted abutment and removable partial denture with non-splinted abutment 3. In case of combination bar attachment retained overdenture stress of root area was the largest and in case of telescopic crown retained overdenture stress of root area was lowest. 4. In case of attachment retained overdenture, stress of residual ridge was lower but stress of root area was larger than in case of removable partial denture


Assuntos
Coroas , Planejamento de Dentadura , Revestimento de Dentadura , Prótese Parcial Removível , Dentaduras , Periodonto , Contenções , Dente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...