Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-22279736

RESUMO

BackgroundRobust diagnostics, capable of detecting multiple variant of SARS-CoV-2 are necessary to mitigate the COVID-19 pandemic. In this study we directly compare the diagnostic capabilities of an LFI engineered with monoclonal antibodies (mAbs) originating from SARS-CoV-2 NP immunizations to the Abbott BinaxNOW COVID-19 Antigen CARD. MethodsHere we established a library of 18 mAbs specific to SARS-CoV-2 NP and used two of these mAbs (1CV7 and 1CV14) to generate a prototype antigen-detection lateral flow immunoassay (LFI). Samples consisting of remnant RT-PCR positive patient nasopharyngeal swabs preserved in viral transport media (VTM) were tested on the 1CV7/1CV14 LFI and the commercially available BinaxNOW test. Assays were allowed to resolve and results were recorded by two observers. FindingsA total of 98 remnant SARS-CoV-2 positive patient specimens were tested on both the 1CV7/1CV14 LFI and the BinaxNOW test. The 1CV7/1CV14 LFI detected 71 of the total 98 specimens, while the BinaxNOW test detected 52 of the 98 specimens. Additionally, the 1CV7/1CV14 LFI consistently detected samples with higher RT-PCR cycle threshold values than the BinaxNOW test. InterpretationThe 1CV7/1CV14 LFI outperformed the BinaxNOW test in the detection of BA.2, BA.2.12.1, and BA.5 Omicron sub-variants when testing remnant RT-PCR positive patient nasopharyngeal swabs diluted in viral transport media. BA.1 and BA.4 detection was comparable. The data suggest that mAbs derived from SARS-CoV-2 NP can aid in a more sensitive diagnostic immunoassay for COVID-19. FundingThe study was funded by the University of Nevada, Renos Research and Innovation Office, DxDiscovery, Inc. internal funds, and through AuCoin Laboratory internal funds. Research in ContextO_ST_ABSEvidence before this studyC_ST_ABSSince the onset of the pandemic, rapid antigen tests have proven themselves to be an accessible, accurate diagnostic platform. The widespread distribution of these tests has aided in curbing the COVID-19 pandemic. Data has shown that the tests manufactured at the beginning of the pandemic, utilizing monoclonal antibodies (mAbs) isolated from severe acute respiratory syndrome coronavirus (SARS-CoV), are less sensitive at detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) Omicron and Omicron subvariants. The reduced sensitivity can lead to diagnostic escape, and possible surges in COVID-19 caseloads Added value of this studyIn this study, a total of 98 remnant RT-PCR confirmed SARS-CoV-2 positive clinical specimens were tested on both a prototype rapid antigen test in the form of a lateral flow immunoassay (LFI) (referred to as the 1CV7/1CV14 LFI) and the available Abbott BinaxNOW COVID-19 Antigen CARD. The 1CV7/1CV14 LFI detected markedly more specimens (71 of 98) specimens than the BinaxNOW test (52 of the 98). Implications of all the available evidenceThis research suggests that that the use of mAbs isolated from immunizations with protein from SARS-CoV-2 may result in a diagnostic assay that is more sensitive in detection of SARS-CoV-2 Omicron subvariants, in comparison to the existing BinaxNOW COVID-19 Antigen CARD.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...