Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Appl Radiat Isot ; 178: 109988, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34688025

RESUMO

PURPOSE: In this study, we used Gafchromic™ film XR-QA2 and RT-QA2 to characterize the film energy response against various radionuclides. We introduce a neutron depletion theoretical model that can describe film response as a function of cumulated activity. The film response was investigated with respect to different backscatter media such as polystyrene, perspex, lead and corrugated fibreboard carton (CFC). The sensitivity of the two types of film to different energies was also studied. Lastly, a film stack method was tested to allow the user to obtain sequential, cumulative doses at different time points. METHODS: Pieces of Gafchromic™ film XR-QA2 and RT-QA2 were exposed to Am-241, Cs-137, Tc-99m, and I-131 to obtain various cumulative activities. After 24 h, each film piece was digitized by scanning it with an Epson Perfection V330 flatbed scanner to obtain 48-bit RGB TIFF images. Afterwards, each image was processed with the Image J software package. The film response was fitted to a theoretically derived function based on the neutron depletion model and the Beer-Lambert Law and compared with an existing fitting function. Layers of the film were also placed together and irradiated with the above-mentioned radionuclides to investigate the possibility of increasing the sensitivity of the film as a dosimeter. The energy response of the two types of film was investigated by irradiating pieces of film with different photon energies. RESULTS: The theoretical response model fits OD vs cumulative activity accurately. XR-QA2 film shows good energy film response by using CFC as a backscatter material when using radionuclides. From the results, it is also evident that XR-QA2 is more sensitive to low energy gamma rays than RT-QA2. Its OD sensitivity can be increased by 2 ± 0.2 when using a double layer film and by 2.8 ± 0.3 when using a triple-layer film. By using a film stack, the experimental time can be decreased by using the second-order polynomial relationship obtained to relate the stacked film data to the single film data. CONCLUSIONS: The neutron depletion theoretical model is accurate and contains less free parameters than higher-order polynomial fits. The Gafchromic™ XR-QA2 film is also better to use in nuclear medicine because of its higher sensitivity. The sensitivity of the film as a dosimeter can also be increased by using multiple layers of film. Experiment times can also be decreased by using the film stack method.

3.
Biomed Phys Eng Express ; 7(3)2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33601352

RESUMO

Purpose. In this study, Monte Carlo (MC) simulations were done to relate the dose-response of the film to that in water. The effect of backscattering materials (PMMA, lead, polystyrene, and air) was investigated on its influence on film density for radionuclides including Am-241, Tc-99m, I-131, Cs-137.Methods. A BEAMnrc MC simulation was designed to score a phase-space file (PSF) below the container of the radionuclide under consideration to use as an input file for the subsequent DOSXYZnrc MC simulation. The geometry of the container holding the radionuclide was built using the component modules available in BEAMnrc. BEAMDP was used to investigate the container effect on the radionuclide spectrum as well as the fluence. The DOSXYZnrc simulation produced the absorbed dose in XR-QA2 and RT-QA2 GafchromicTMfilms. The DOSXYZnrc simulations were repeated for the GafchromicTMfilm now replaced with water to get the absorbed dose in water. From these results, conversion factors for the dose in water to the film dose for the different radionuclides, Am-241, Tc-99m, I-131, and Cs-137 were obtained. The actual film dose was calculated using the specific gamma exposure constant (Γ) at a distance of 50 cm for a point source approximation. From the BEAMnrc simulations, the particle fluence was extracted from PSFs to correct for the fluence at 0.1 cm below the sources from the fluence 50 cm away since the inverse square law will not apply to finite-size sources. The absorbed dose profiles in the film were compared to the absorbed dose profiles from the MC simulations.Results. A fitting function based on the neutron depletion model fits the optical density versus absorbed film dose data well and can be used as a calibration tool to obtain the film dose from its optical density. Lead as a backscatter material results in a higher optical density change but a lower absorbed dose. The XR-QA2 GafchromicTMfilm is more sensitive than the RT-QA2 GafchromicTMfilm, showing a more responsive optical density (OD) change in the energy range of radionuclides used in this study. Conversion factors were determined to convert the dose in water to the dose in GafchromicTMfilm. The Am-241 and I-131 simulated absorbed dose in the film to dose in water does not fluctuate as much as the simulated absorbed dose in film and water when using Tc-99m and Cs-137. Validation was shown for the comparison of the film and MC simulation absorbed dose profiles.Conclusions. MC BEAMnrc simulations are useful to simulate radionuclides and their containers. BEAMDP extracted energy spectra showed that the radionuclide containers produced a Compton effect on the energy spectra and added filtration on the lower spectral photon components. Extracted fluence ratios from PSFs were used to calculate the absorbed dose value at 0.1 cm distance from the source. By using the fit function, the dose in the film can be determined for known optical density values. The effect of the backscatter materials showed that the XR-QA2 GafchromicTMfilm results in higher optical density values than the RT-QA2 GafchromicTMfilm. The absorbed dose in both the films is comparable but not for a radionuclide such as Am-241 with an activity of 74MBq. The lead backscatter material showed to be the most prominent in optical density enhancement, and the air equivalent material was the least prominent. The XR-QA2 GafchromicTMfilm is the most sensitive and will be the best option if working with low energies. The absorbed dose in the XR-QA2 GafchromicTMfilm also showed a good comparison to the absorbed dose in water for the Am-241 radionuclide with an activity of 74MBq. The absorbed dose in the films compares well to the MC simulated doses.


Assuntos
Água/química , Radioisótopos de Césio , Dosimetria Fotográfica , Radioisótopos do Iodo , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...