Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Infect Dis ; 44(11): 1408-14, 2007 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-17479934

RESUMO

BACKGROUND: Needleless intravascular catheter connector valves have been introduced into clinical practice to minimize the risk of needlestick injury. However, infection-control risks associated with these valves may be underappreciated. In March 2005, a dramatic increase in bloodstream infections was noted in multiple patient care units of a hospital in temporal association with the introduction of a needleless valve into use. METHODS: Surveillance for primary bloodstream infection was conducted using standard methods throughout the hospital. Blood culture contamination rates were monitored. Cultures were performed using samples obtained from intravascular catheter connector valves. RESULTS: The relative risk of bloodstream infection for the time period in which the suspect connector valve was in use, compared with baseline, was 2.79 (95% confidence interval, 2.27-3.43). In critical care units, the rate of primary bloodstream infection increased with the introduction of the valve from 3.87 infections per 1000 catheter-days to 10.64 infections per 1000 catheter-days (P<.001), and it decreased to 5.59 infections per 1000 catheter-days (P=.02) in the 6 months following removal of the device from use. Similarly, in inpatient nursing units, the rate of bloodstream infection increased from 3.47 infections per 1000 catheter-days to 7.3 infections per 1000 catheter-days (P=.02) following introduction of the device, and it decreased to 2.88 infections per 1000 catheter-days (P=.57) following removal of the device from use. Similar events occurred in the cooperative care units. The rate of blood culture contamination did not substantially change over the course of the study. Of 37 valves that were subjected to microbiological sample testing, 24.3% yielded microbes, predominantly coagulase-negative staphylococci. CONCLUSION: A significant association between primary bloodstream infection and a needleless connector valve was observed. Evaluation of needleless connector valves should include a thorough assessment of infection risks in prospective randomized trials prior to their introduction to the market.


Assuntos
Bacteriemia/epidemiologia , Bacteriemia/etiologia , Cateterismo/instrumentação , Surtos de Doenças , Contaminação de Equipamentos , Humanos , Fatores de Risco
2.
Biosecur Bioterror ; 4(4): 351-65, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17238819

RESUMO

In spite of great advances in medicine, serious communicable diseases are a significant threat. Hospitals must be prepared to deal with patients who are infected with pathogens introduced by a bioterrorist act (e.g., smallpox), by a global emerging infectious disease (e.g., avian influenza, viral hemorrhagic fevers), or by a laboratory accident. One approach to hazardous infectious diseases in the hospital setting is a biocontainment patient care unit (BPCU). This article represents the consensus recommendations from a conference of civilian and military professionals involved in the various aspects of BPCUs. The role of these units in overall U.S. preparedness efforts is discussed. Technical issues, including medical care issues (e.g., diagnostic services, unit access); infection control issues (e.g., disinfection, personal protective equipment); facility design, structure, and construction features; and psychosocial and ethical issues, are summarized and addressed in detail in an appendix. The consensus recommendations are presented to standardize the planning, design, construction, and operation of BPCUs as one element of the U.S. preparedness effort.


Assuntos
Doenças Transmissíveis , Consenso , Isolamento de Pacientes/organização & administração , Doenças Transmissíveis/transmissão , Arquitetura Hospitalar , Humanos , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...