Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Eur Heart J Cardiovasc Imaging ; 15(6): 659-65, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24408930

RESUMO

OBJECTIVES: We compared the accuracy of quantified myocardial flow reserve and absolute stress myocardial blood flow (MBF) alone in the detection of coronary artery disease (CAD). BACKGROUND: Myocardial flow reserve, i.e. ratio of stress and rest flow, has been commonly used to detect CAD with many imaging modalities. However, it is not known whether absolute stress flow alone is sufficient for detection of significant CAD. METHODS: We enrolled 104 patients with moderate (30-70%) pre-test likelihood of CAD without previous myocardial infarction. MBF was measured by positron emission tomography and O-15-water at rest and during the adenosine stress in the regions of the left anterior descending, left circumflex, and right coronary artery. All the patients underwent invasive coronary angiography including the measurement of fractional flow reserve when appropriate. RESULTS: Quantified myocardial flow reserve (optimal cut-off value 2.5) detected significant coronary stenosis with sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 81, 87, 66 and 94%, respectively. When compared with flow reserve, absolute MBF at stress (optimal cut-off value of 2.4 mL/min/g) was more accurate in detecting significant coronary stenosis [area under the curve (AUC) 0.94 vs. 0.90, P = 0.02] with sensitivity, specificity, PPV, and NPV of 95% (P = 0.03 vs. flow reserve), 90, 73, and 98%, respectively. An absolute increase of MBF from rest to stress by <1.5 mL/g/min had also similar accuracy in detecting CAD (AUC: 0.95). The results were comparable in patients who did and did not receive i.v. beta-blockers prior imaging. CONCLUSIONS: Absolute stress perfusion alone was superior to perfusion reserve in the detection of haemodynamically significant CAD and allows shorter imaging protocols with smaller radiation dose.


Assuntos
Antagonistas Adrenérgicos beta/administração & dosagem , Doença da Artéria Coronariana/diagnóstico , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Imagem Multimodal/métodos , Imagem de Perfusão do Miocárdio/métodos , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Angiografia Coronária/métodos , Doença da Artéria Coronariana/tratamento farmacológico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons/métodos , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X/métodos
2.
Eur Heart J Cardiovasc Imaging ; 13(1): 79-85, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21880607

RESUMO

AIMS: Accelerated flow at the site of flow-limiting stenosis can be detected by transthoracic Doppler echocardiography (TTDE). We studied feasibility and accuracy of sequential coronary computed tomography angiography (CTA) and TTDE in detection of haemodynamically significant coronary artery disease (CAD). METHODS AND RESULTS: We prospectively enrolled 107 patients with intermediate (30-70%) pre-test likelihood of CAD. All patients underwent CTA using a 64-slice scanner. Using TTDE, the ratio of maximal diastolic flow velocity to pre-stenotic flow velocity (M/P ratio) was measured in the coronary segments with stenosis in CTA. In all patients, the results were compared with invasive coronary angiography, including measurement of fractional flow reserve when appropriate. All analyses were done blinded. TTDE was feasible in 276 of 285 evaluated coronary segments. Significant coronary stenoses were associated with a higher M/P ratio than non-significant stenoses (3.59 ± 1.82 vs. 1.28 ± 0.60, P < 0.001). The optimal M/P ratio for detection of significant stenosis was 2.2 (area under receiver operating characteristic curve 0.92, P < 0.001). Compared with the strategy of CTA alone, sequential CTA and focused TTDE had a better positive predictive value (PPV; 61 vs. 78%) and diagnostic accuracy (93 vs. 96%, P = 0.006) without impairment of the negative predictive value (97 vs. 97%). CONCLUSION: Sequential use of CTA and TTDE is feasible for combined anatomic and functional evaluation of coronary stenoses. Compared with coronary CTA alone, addition of TTDE improved PPV for detection of significant CAD.


Assuntos
Estenose Coronária/diagnóstico , Descanso , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/patologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Ecocardiografia , Estudos de Viabilidade , Feminino , Indicadores Básicos de Saúde , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Estatística como Assunto , Tomografia Computadorizada por Raios X
3.
Circ Cardiovasc Imaging ; 4(6): 678-84, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21926262

RESUMO

BACKGROUND: The standard interpretation of perfusion imaging is based on the assessment of relative perfusion distribution. The limitations of that approach have been recognized in patients with multivessel disease and endothelial dysfunction. To date, however, no large clinical studies have investigated the value of measuring quantitative blood flow and compared that with relative uptake. METHODS AND RESULTS: One hundred four patients with moderate (30%-70%) pretest likelihood of coronary artery disease (CAD) underwent PET imaging during adenosine stress using (15)O-water and dynamic imaging. Absolute myocardial blood flow was calculated from which both standard relative myocardial perfusion images and images scaled to a known absolute scale were produced. The patients and the regions then were classified as normal or abnormal and compared against the reference of conventional angiography with fractional flow reserve. In patient-based analysis, the positive predictive value, negative predictive value, and accuracy of absolute perfusion in the detection of any obstructive CAD were 86%, 97%, and 92%, respectively, with absolute quantification. The corresponding values with relative analysis were 61%, 83%, and 73%, respectively. In region-based analysis, the receiver operating characteristic curves confirmed that the absolute quantification was superior to relative assessment. In particular, the specificity and positive predictive value were low using just relative differences in flow. Only 9 of 24 patients with 3-vessel disease were correctly assessed using relative analysis. CONCLUSIONS: The measurement of myocardial blood flow in absolute terms has a significant impact on the interpretation of myocardial perfusion. As expected, multivessel disease is more accurately detected.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária/fisiologia , Ecocardiografia sob Estresse/métodos , Perfusão/métodos , Tomografia por Emissão de Pósitrons/métodos , Velocidade do Fluxo Sanguíneo , Estudos de Coortes , Meios de Contraste , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença
4.
Arterioscler Thromb Vasc Biol ; 31(1): 211-8, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21030717

RESUMO

OBJECTIVE: To measure intrapericardial fat (IPF), extrapericardial fat (EPF), and myocardial perfusion (MBF) in patients with and without coronary artery disease (CAD), hypothesizing that perfusion is more strongly associated with IPF because it is in direct anatomic contiguity with the myocardium or coronary arteries. METHODS AND RESULTS: Fat surrounding the heart may increase the risk of CAD and calcification, but little is known about the role of MBF in this relationship. The study included 107 patients with an intermediate likelihood of CAD. Positron emission tomography/computed tomography was used to measure IPF and EPF volumes and coronary artery calcium level, together with MBF at rest and during adenosine-induced hyperemia. Subsequently, all subjects underwent coronary angiography and were grouped for presence/absence of CAD and severity of myocardial hypoperfusion. IPF and EPF levels were higher in men and in patients with CAD (n=85) than in those without CAD (n=22) (P<0.001). EPF was increased regardless of the degree of stenoses (n=45), whereas IPF was selectively increased in subjects with obstructive stenoses (n=40). IPF and EPF levels were both associated with coronary artery calcium scores (R=0.25 and R=0.26, respectively; P<0.02), coronary flow reserve (R=-0.37 and R=-0.38, respectively; P<0.001), and hyperemic MBF (R=-0.36 and R=-0.44, respectively; P<0.0005). Male sex was a strong negative predictor of MBF. After discounting for confounders, myocardial hyperemic perfusion was predicted independently by sex, coronary artery calcium score, and IPF, but not EPF. CONCLUSIONS: CAD is accompanied by augmented fat depots surrounding the heart, which are negatively related to coronary flow hyperemia. Among fat depots, IPF was the only independent predictor of hyperemic MBF, supporting the hypothesis of a direct paracrine/vasocrine effect.


Assuntos
Adiposidade , Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária , Hiperemia/fisiopatologia , Pericárdio/fisiopatologia , Adenosina , Idoso , Calcinose/fisiopatologia , Distribuição de Qui-Quadrado , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Feminino , Finlândia , Reserva Fracionada de Fluxo Miocárdico , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores Sexuais , Tomografia Computadorizada por Raios X , Vasodilatadores
5.
Eur J Nucl Med Mol Imaging ; 36(10): 1594-602, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19408000

RESUMO

PURPOSE: Carimas (Cardiac Image Analysis System) is a new software package developed at the Turku PET Centre for the quantitation of PET studies of the heart with a broad range of tracers. The goal of this study was to assess the reproducibility of results the package provides for myocardial perfusion (MP) quantitation using (15)O-labelled water. METHODS: Four observers with various levels of experience in nuclear medicine independently analysed 20 MP studies (10 rest flow: "rest", 10 adenosine-induced hyperaemia: "stress"). Each study was analysed twice. The linear mixed model for repeated measures was fitted to the data to calculate intraclass correlation coefficients (ICC), differences between the repeats (the intraobserver differences) and differences between the observers (the interobserver differences). Also, Pearson correlation coefficients (r) were calculated and Bland-Altman plots were drawn. The reproducibility of MP was assessed on global, regional and segmental levels. Thereafter, this analysis was applied in 48 consecutive clinical patients with suspected coronary heart disease (CHD). RESULTS: For the experienced observer the Pearson r for all segments was 0.974 at rest and 0.978 at stress (p < 0.0001), and the repeatability coefficients were 0.145 ml/g per min (15.5% of the average) and 0.389 ml/g per min (14.9%), correspondingly. The ICC reflected very good overall reproducibility. The intraobserver and interobserver differences were small, and the difference between the most and the least experienced observers at stress was 8.5% for the global MP. The clinical accuracy of the perfusion in the detection of CHD was excellent (positive predictive value 91% and negative predictive value 88%) against invasive angiography. CONCLUSION: The results demonstrate high reproducibility of myocardial perfusion quantitation with (15)O-labelled water PET using Carimas. The results support the feasibility of robust analysis and good clinical accuracy.


Assuntos
Coração/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Radioisótopos de Oxigênio , Tomografia por Emissão de Pósitrons/métodos , Idoso , Circulação Coronária , Doença das Coronárias/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/estatística & dados numéricos , Tomografia por Emissão de Pósitrons/estatística & dados numéricos , Reprodutibilidade dos Testes , Software , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...