Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Medicina (Kaunas) ; 60(2)2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38399551

RESUMO

Background and Objectives: Atrial fibrillation (AF), a prevalent cardiac arrhythmia, significantly impacts the quality of life of those affected. The preferred treatment for symptomatic AF, particularly when pharmacological methods fall short, is catheter ablation with pulmonary vein isolation (PVI). While common pulmonary vein (PV) anatomical variants, such as the right accessory pulmonary vein and the common ostium of left pulmonary veins (LCPV), have been studied extensively, their impact on the long-term outcome of PVI is known to be minimal. However, data on less common anomalies, like the common ostium of the left and right inferior pulmonary vein (CIPV), remain scarce in the medical literature. This report aims to shed light on the challenges and outcomes of catheter ablation in a patient with a rare CIPV anomaly. By presenting this case, we contribute to the limited knowledge about the management of such unique anatomical variations in AF treatment and discuss the importance of individualized treatment approaches. Case Presentation: We present a case involving a 56-year-old male diagnosed with AF in 2018. Initial PVI treatment was successful, but the patient experienced symptom recurrence after three years. A preprocedural CT scan before the second ablation revealed a CIPV anomaly. During the repeat procedure, a right superior pulmonary vein (RSPV) reisolation was performed due to identified gaps in the previous ablation line. Post-procedure, the patient maintained a sinus rhythm and reported no further symptoms. Conclusions: This case highlights the importance of recognizing rare PV anatomies like CIPV in the effective management of AF. Tailored ablation strategies, accounting for unique anatomical conditions, can lead to successful long-term outcomes, reinforcing the need for personalized approaches in AF treatment, especially in cases involving complex anatomical variations.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Masculino , Humanos , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Qualidade de Vida , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
2.
J Infect Dev Ctries ; 15(9): 1277-1280, 2021 09 30.
Artigo em Inglês | MEDLINE | ID: mdl-34669596

RESUMO

INTRODUCTION: The estimated infection rate after permanent endocardial lead implantation is between 1% and 2%. Pacemaker lead endocarditis is treated with total removal of the infected device and proper antibiotics. In this case report, we present a patient with delayed diagnosis and treatment due to the COVID-19 outbreak. CASE REPORT: An 88-year-old, pacemaker dependent woman with diagnosed pacemaker pocket infection was admitted to the University Cardiovascular institute. The patient had a prolonged follow-up time due to the COVID-19 outbreak. She missed her routine checkup and came to her local hospital when the generator had already protruded completely, to the point where she held it in her own hand. Transthoracic echocardiogram showed possible vegetations on the lead. Transesophageal echocardiography was not performed due to the COVID-19 pandemic. On the day after the admission the patient underwent transvenous removal of the pacemaker lead using a 9 French gauge rotational extraction sheathe (Cook Medical). The extracted lead was covered in a thin layer of vegetations. Further follow-ups showed good recovery with no complications. CONCLUSIONS: A case showing delayed treatment of pacemaker pocket infection, due to delayed follow-up time during the COVID-19 pandemic. This patient underwent successful transvenous removal of the infected pacemaker lead, along with adequate antibiotic therapy, which has proven to be the most effective method of treating cardiac device-related endocarditis.


Assuntos
Remoção de Dispositivo , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , COVID-19 , Feminino , Humanos , Infecções Relacionadas à Prótese/terapia , Tempo para o Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...