Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Chir Orthop Traumatol Cech ; 89(1): 16-26, 2022.
Artigo em Tcheco | MEDLINE | ID: mdl-35247240

RESUMO

PURPOSE OF THE STUDY Laboratory methods are central to prosthetic joint infection (PJI) diagnosis. Most research teams focus on detection of specific inflammatory markers, causative pathogens, or on assessment of the tissue response. This study sought to determine the optimal cut-off values and diagnostic performance of selected synovial markers in relation to the diagnosis of hip or knee PJI. The studied markers were synovial level of glucose, lactate, coefficient of energy balance (CEB) and NGAL (neutrophil gelatinase-associated lipocalin). MATERIAL AND METHODS This prospective study includes 89 patients who underwent revision total knee or hip arthroplasty for septic or aseptic reasons in the period from 2014 to 2017. Among these 89 patients, there are 2 cases of prosthetic hip infection, 22 cases of prosthetic knee infection, 31 aseptic revision total hip arthroplasties and 34 aseptic revision total knee arthroplasties. The diagnostic characteristics of the studied methods were set in relation to the reference standard, the 2013 MSIS (Musculoskeletal Infection Society) criteria. The cut-off values were calculated using the ROC (receiver operating characteristic curve) analysis. RESULTS The synovial glucose test is considered positive if the glucose level drops below 2.65 mmol/L. The area under the curve is 0.813, sensitivity 75.0%, specificity 83.1%. The synovial lactate test is considered positive if lactate level rises above 8.87 mmol/L. The area under the curve is 0.882, sensitivity 70.8%, specificity 95.4%. Synovial NGAL is considered positive if its level exceeds 998 µg/L. The area under the curve is 1.000, sensitivity 100.0%, specificity 100.0%. CEB is considered positive if its value is lower than +4.665. The area under the curve is 0.883, sensitivity 91.7% and specificity 69.8%. Combining of these tests with other synovial markers does not improve the diagnostic performance of the studied tests. CONCLUSIONS The glucose and lactate levels and CEB undoubtedly reflect the presence of an inflammatory process in a prosthetic joint. However, the diagnostic characteristics of these tests are not better than those of other modern diagnostic techniques. As opposed to these tests, synovial NGAL shows excellent diagnostic performance. Nonetheless, the potential of this method shall be verified on larger cohorts of patients. Key words: prosthetic joint infection, periprosthetic infection, total knee arthroplasty, total hip arthroplasty, diagnosis, glucose, lactate, CEB, NGAL.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Prótese do Joelho , Infecções Relacionadas à Prótese , Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Biomarcadores/análise , Proteína C-Reativa/análise , Glucose , Humanos , Prótese do Joelho/efeitos adversos , Ácido Láctico , Lipocalina-2/análise , Estudos Prospectivos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/etiologia , Sensibilidade e Especificidade , Líquido Sinovial/química
2.
Toxicol In Vitro ; 74: 105162, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33839235

RESUMO

Silymarin is a flavonoid complex isolated from the plant Silybum marianum which is well known for its antioxidant, hepatoprotective and immunomodulatory effects. Since little is known about its anti-inflammatory properties and healing effects, our study focused on whether or not silymarin components reduce inflammation and support epidermis regeneration. Lipopolysaccharides (LPS) and sodium dodecyl sulfate (SDS) were used to induce inflammation in normal human epidermal keratinocytes (NHEKs) and reconstructed epidermis (RHE), respectively. The expression of pro-inflammatory cytokines (IL-1, IL-6 and IL-8) in NHEKs and RHE was measured by enzyme - linked immunosorbent assay (ELISA). The expression of cytokeratin 14 and loricrin in RHE was detected by immunofluorescent analysis. Hematoxylin and eosin staining was used for the morphological evaluation of RHE. It was determined that 2, 3 - dehydrosilybin (DHSB) downregulated the production of selected pro-inflammatory cytokines produced by NHEKs. Although all layers of RHE displayed full thickness, when SDS was applied, cell detachment was seen in the stratum corneum and loricrin expression was diminished.


Assuntos
Anti-Inflamatórios/farmacologia , Epiderme/efeitos dos fármacos , Queratinócitos/efeitos dos fármacos , Quercetina/farmacologia , Silimarina/farmacologia , Citocinas/metabolismo , Epiderme/metabolismo , Humanos , Inflamação/induzido quimicamente , Queratina-14/metabolismo , Queratinócitos/metabolismo , Lipopolissacarídeos/toxicidade , Proteínas de Membrana/metabolismo , Dodecilsulfato de Sódio/toxicidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...