Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Braz J Med Biol Res ; 51(4): e6062, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29513788

RESUMO

Liver resection is the standard treatment for any liver lesion. Laparoscopic liver resection is associated with lower intra-operative blood loss and fewer complications than open resection. Access to the posterior part of the right liver lobe is very uncomfortable and difficult for surgeons due the anatomic position, especially when employing laparoscopic surgery. Based on these experiences, a new laparoscopic device was developed that is capable of bending its long axis and allowing the application of radiofrequency energy in areas that were not technically accessible. The device is equipped with four telescopic needle electrodes that cause tissue coagulation after the delivery of radiofrequency energy. Ex vivo testing was performed in 2012 and 2014 at the University Hospital, Ostrava, on a porcine liver tissue. The main goal of this testing was to verify if the newly proposed electrode layout was suitable for sufficient tissue coagulation and creating a safety zone around lesions. During the ex vivo testing, the material of needle electrodes was improved to achieve the lowest possibility of adhesion. The power supply was adjusted from 20 to 120 W and the ablation time, which varied from 10 to 110 s, was monitored. Subsequently, optimal power delivery and time for coagulation was determined. This experimental study demonstrated the feasibility and safety of the newly developed device. Based on the ex vivo testing, LARA-K1 can create a safety zone of coagulation. For further assessment of the new device, an in vivo study should be performed.


Assuntos
Ablação por Cateter/instrumentação , Desenho de Equipamento , Hemostasia Cirúrgica/instrumentação , Hepatectomia/instrumentação , Laparoscopia/instrumentação , Fígado/cirurgia , Hepatectomia/métodos , Humanos , Laparoscopia/métodos
2.
Braz. j. med. biol. res ; 51(4): e6062, 2018. graf
Artigo em Inglês | LILACS | ID: biblio-889069

RESUMO

Liver resection is the standard treatment for any liver lesion. Laparoscopic liver resection is associated with lower intra-operative blood loss and fewer complications than open resection. Access to the posterior part of the right liver lobe is very uncomfortable and difficult for surgeons due the anatomic position, especially when employing laparoscopic surgery. Based on these experiences, a new laparoscopic device was developed that is capable of bending its long axis and allowing the application of radiofrequency energy in areas that were not technically accessible. The device is equipped with four telescopic needle electrodes that cause tissue coagulation after the delivery of radiofrequency energy. Ex vivo testing was performed in 2012 and 2014 at the University Hospital, Ostrava, on a porcine liver tissue. The main goal of this testing was to verify if the newly proposed electrode layout was suitable for sufficient tissue coagulation and creating a safety zone around lesions. During the ex vivo testing, the material of needle electrodes was improved to achieve the lowest possibility of adhesion. The power supply was adjusted from 20 to 120 W and the ablation time, which varied from 10 to 110 s, was monitored. Subsequently, optimal power delivery and time for coagulation was determined. This experimental study demonstrated the feasibility and safety of the newly developed device. Based on the ex vivo testing, LARA-K1 can create a safety zone of coagulation. For further assessment of the new device, an in vivo study should be performed.


Assuntos
Humanos , Ablação por Cateter/instrumentação , Laparoscopia/instrumentação , Desenho de Equipamento , Hemostasia Cirúrgica/instrumentação , Hepatectomia/instrumentação , Fígado/cirurgia , Laparoscopia/métodos , Hepatectomia/métodos
3.
Technol Cancer Res Treat ; 14(5): 573-82, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24945372

RESUMO

The incidence of colorectal carcinoma is still growing in the Czech Republic and also all around the world. With success of oncological treatment is also growing a number of potential patients with liver metastases, who can profit from surgical therapy. The aim of this study was to confirm on porcine models that this method by using new surgical device is effective and safe for patients who have to undergo liver resection. The primary hypothesis of the study was to evaluate whether this new device is able to consistently produce homogeneous and predictable areas of coagulation necrosis without the Pringle maneuver of vascular inflow occlusion. The secondary hypothesis of the study was to compare the standard linear radiofrequency device and a new semi-spherical bipolar device for liver ablation and resection in a hepatic porcine model. Twelve pigs were randomly divided into two groups. Each pig underwent liver resection from both liver lobes in the marginal, thinner part of liver parenchyma. The pigs in first group were operated with standard using device and in the second group we used new developed semi-spherical device. We followed blood count in 0(th), 14(th) and 30(th) day from operation. 14(th) day from resection pigs underwent diagnostic laparoscopy to evaluate of their state, and 30(th) day after operation were all pigs euthanized and subjected to histopathological examination. Histopathological evaluation of thermal changes at the resection margin showed strong thermal alteration in both groups. Statistical analysis of collected dates did not prove any significant (p < 0.05) differences between standard using device and our new surgical tool. We proved safety of new designed semi-spherical surgical. This device can offer the possibility of shortening the ablation time and operating time, which is benefit for patients undergoing the liver resection.


Assuntos
Ablação por Cateter/métodos , Neoplasias Colorretais/radioterapia , Hepatectomia/métodos , Neoplasias Hepáticas/radioterapia , Animais , Neoplasias Colorretais/cirurgia , República Tcheca , Modelos Animais de Doenças , Feminino , Laparoscopia , Fígado/patologia , Fígado/cirurgia , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/cirurgia , Masculino , Sus scrofa
4.
Environ Int ; 59: 372-83, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23911337

RESUMO

Passive and composite sampling in combination with in vitro bioassays and identification and quantification of individual chemicals were applied to characterize pollution by compounds with several specific modes of action in urban area in the basin of two rivers, with 400,000 inhabitants and a variety of industrial activities. Two types of passive samplers, semipermeable membrane devices (SPMD) for hydrophobic contaminants and polar organic chemical integrative samplers (POCIS) for polar compounds such as pesticides and pharmaceuticals, were used to sample wastewater treatment plant (WWTP) influent and effluent as well as rivers upstream and downstream of the urban complex and the WWTP. Compounds with endocrine disruptive potency were detected in river water and WWTP influent and effluent. Year-round, monthly assessment of waste waters by bioassays documented estrogenic, androgenic and dioxin-like potency as well as cytotoxicity in influent waters of the WWTP and allowed characterization of seasonal variability of these biological potentials in waste waters. The WWTP effectively removed cytotoxic compounds, xenoestrogens and xenoandrogens. There was significant variability in treatment efficiency of dioxin-like potency. The study indicates that the WWTP, despite its up-to-date technology, can contribute endocrine disrupting compounds to the river. Riverine samples exhibited dioxin-like, antiestrogenic and antiandrogenic potencies. The study design enabled characterization of effects of the urban complex and the WWTP on the river. Concentrations of PAHs and contaminants and specific biological potencies sampled by POCIS decreased as a function of distance from the city.


Assuntos
Disruptores Endócrinos/análise , Receptores Androgênicos/metabolismo , Receptores de Hidrocarboneto Arílico/metabolismo , Receptores de Estrogênio/metabolismo , Rios/química , Águas Residuárias/química , Poluentes Químicos da Água/análise , Androgênios/análise , Androgênios/farmacologia , Animais , Bioensaio , Linhagem Celular Tumoral , Cidades , República Tcheca , Dioxinas/análise , Dioxinas/farmacologia , Disruptores Endócrinos/farmacologia , Monitoramento Ambiental , Estrogênios/análise , Estrogênios/farmacologia , Praguicidas/análise , Praguicidas/farmacologia , Dibenzodioxinas Policloradas/análise , Dibenzodioxinas Policloradas/farmacologia , Hidrocarbonetos Policíclicos Aromáticos/análise , Hidrocarbonetos Policíclicos Aromáticos/farmacologia , Ratos , Instalações de Eliminação de Resíduos , Poluentes Químicos da Água/farmacologia , Purificação da Água
5.
Environ Toxicol Pharmacol ; 23(3): 297-301, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-21783771

RESUMO

The aim of this study was to assess the effect of deltamethrin on rainbow trout (Oncorhynchus mykiss). Control and experimental group of fish were exposed to Decis EW 50 pesticide preparation (active substance 50g/l of deltamethrin). The acute semistatical toxicity test lasting 96h was performed on rainbow trout juveniles. The 96hLC(50) value of Decis EW 50 was 0.02mg/l. Examination of haematological and biochemical profile and histological tissue examination was performed on 1-2-year-old rainbow trout after 96h of exposure to Decis EW 50 in a concentration of 0.02mg/l. The experimental group showed significantly lower values (p<0.05) of plasma glucose, alanine aminotransferase, cholinesterase and significantly higher (p<0.05) values of erythrocyte count, haemoglobin content, haematocrit and plasma total protein, albumins, ammonia, aspartate aminotransferase, creatinekinase and calcium compared to the control group. The deltamethrin-based Decis EW 50 pesticide preparation was classified among substances strongly toxic for fish.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...