Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Medicina (Kaunas) ; 60(4)2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38674313

RESUMO

Background and Objectives: The combination of aortic valve stenosis (AS) and ischemic heart disease (IHD) is quite common and is associated with myocardial fibrosis (MF). The purpose of this study was to evaluate the association between the histologically verified left ventricular (LV) MF and its geometry and function in isolated AS and AS within IHD groups. Materials and Methods: In a single-center, prospective trial, 116 patients underwent aortic valve replacement (AVR) with/without concomitant surgery. The study population was divided into groups of isolated AS with/without IHD. Echocardiography was used, and LV measurements and aortic valve parameters were obtained from all patients. Myocardial tissue was procured from all study patients undergoing elective surgery. Results: There were no statistical differences between isolated AS and AS+IHD groups in LV parameters or systolic and diastolic functions during the study periods. The collagen volume fraction was significantly different between the isolated AS and AS+IHD groups and was 7.3 ± 5.6 and 8.3 ± 6.4, respectively. Correlations between MF and left ventricular end-diastolic diameter (LVEDD) (r = 0.59, p = < 0.001), left ventricular mass (LVM) (r = 0.42, p = 0.011), left ventricular ejection fraction (LVEF) (r = -0.67, p < 0.001) and an efficient orifice area (EOA) (r = 0.371, p = 0.028) were detected in isolated AS during the preoperative period; the same was observed for LVEDD (r = 0.45, p = 0.002), LVM (r = 0.36, p = 0.026), LVEF (r = -0.35, p = 0.026) and aortic annulus (r = 0.43, p = 0.018) in the early postoperative period; and LVEDD (r = 0.35, p ≤ 0.05), LVM (r = 0.43, p = 0.007) and EOA (r = 0.496, p = 0.003) in the follow-up period. In the group of AS and IHD, correlations were found only with LV posterior wall thickness (r = 0.322, p = 0.022) in the follow-up period. Conclusions: Histological MF in AS was correlated with LVM and LVEDD in all study periods. No correlations between MF and LV parameters were found in aortic stenosis in the ischemic heart disease group across all study periods.


Assuntos
Estenose da Valva Aórtica , Ecocardiografia , Fibrose , Ventrículos do Coração , Humanos , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Prospectivos , Idoso , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Ecocardiografia/métodos , Miocárdio/patologia , Função Ventricular Esquerda/fisiologia , Isquemia Miocárdica/fisiopatologia , Isquemia Miocárdica/complicações
2.
Catheter Cardiovasc Interv ; 103(7): 1111-1124, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38591535

RESUMO

BACKGROUND: The dry-pericardium Vienna transcatheter aortic valve system is repositionable and retrievable, already premounted on the delivery system, eliminating the need for assembly and crimping of the device before valve implantation. METHODS: The VIVA first-in-human feasibility study, a prospective, nonrandomized, single-center trial, evaluated the Vienna aortic valve in 10 patients with severe symptomatic aortic stenosis, who were at intermediate or high surgical risk. This study, registered at ClinicalTrials.gov (NCT04861805), focused on the safety, feasibility, clinical and hemodynamic performance of the Vienna system up to 1-year follow-up. RESULTS: The mean patient age was 79 ± 5 years, 60% male. Valve sizes used: 26 mm (10%), 29 mm (30%), 31 mm (60%). Key hemodynamic improvements were significant: mean aortic valve pressure gradient (mmHg) decreased from 48.7 to 8.1, aortic valve area (cm2) increased from 0.75 to 1.91, and maximum jet velocity through the aortic valve (m/s) decreased from 4.41 to 1.95 (p < 0.0001). No moderate/severe paravalvular leakage was observed, and computed tomography scans revealed no evidence of hypo-attenuated leaflet thickening. The study recorded one life-threatening bleeding event, two cases requiring postprocedural pacemaker implantation, and three ischemic events, with only one causing lasting neurological impairment. Importantly, there were no cases of cardiovascular mortality and only one noncardiovascular death, which was confirmed as unrelated to the device. CONCLUSIONS: The study indicates the Vienna valve as a potential option for severe symptomatic aortic stenosis, designed to streamline the procedure and potentially lower healthcare costs by reducing resource and equipment needs, also procedural errors. Further research is essential to thoroughly evaluate its safety and efficacy.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Estudos de Viabilidade , Próteses Valvulares Cardíacas , Hemodinâmica , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Idoso , Feminino , Estudos Prospectivos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Índice de Gravidade de Doença , Recuperação de Função Fisiológica , Bioprótese , Fatores de Risco
3.
Front Cardiovasc Med ; 10: 1199047, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37522086

RESUMO

Background: The novel Vienna TAVI system is repositionable and retrievable, already pre-mounted on the delivery system, eliminating the need for assembly and crimping of the device prior to valve implantation. Aims: The purpose of this first-in-human feasibility study was to determine the safety, feasibility, clinical and hemodynamic performance of the Vienna TAVI system at 6-month follow-up. (ClinicalTrials.gov identifier NCT04861805). Methods: This is a prospective, non-randomized, single-arm, single-center, first-stage FIH feasibility study, which is followed by a second-stage pivotal, multicenter, multinational study in symptomatic patients with severe aortic stenosis (SAS). The first-stage FIH study evaluated the safety and feasibility, clinical and hemodynamic performance of the device in 10 patients with SAS based on recommendations by the VARC-2. Results: All patients were alive at 3-month follow-up. 1 non-cardiovascular mortality was reported 5 months after implantation. There were no new cerebrovascular events, life-threatening bleeding or conduction disturbances observed at 6-month follow-up. The mean AV gradient significantly decreased from 48.7 ± 10.8 to 7.32 ± 2.0 mmHg and mean AVA increased from 0.75 ± 0.18 to 2.16 ± 0.42 cm2 (p < 0.00001). There was no incidence of moderate or severe total AR observed. In the QoL questionnaires, the patients reported a significant improvement from the baseline 12-KCCQ mean score 58 ± 15 to 76 ± 20. NYHA functional class improved in two patients, remained unchanged in one patient. There was an increase in mean 6-min-walk distance from baseline 285 ± 97 to 347 ± 57 m. Conclusions: This study demonstrates that using Vienna TAVI system has favourable and sustained 6-month safety and performance outcomes in patients with symptomatic severe aortic stenosis.

4.
Artigo em Inglês | MEDLINE | ID: mdl-36612333

RESUMO

Background: The NR3C2 gene encodes the mineralocorticoid receptor, which is present on cardiomyocytes. Prior studies reported an association between the presence of NR3C2 single-nucleotide polymorphisms (SNPs) and an increased cortisol production during a stress response such as acute myocardial infarction (AMI), which may lead to adverse cardiac remodeling. Objective: To study the impact of the NR3C2 rs2070950, rs4635799 and rs5522 gene polymorphisms on left ventricular (LV) remodeling, rhythm and conduction disorders in AMI patients. Methods: A cohort of 301 AMI patients who underwent revascularization was included. SNPs of the NR3C2 gene (rs2070950, rs4635799 and rs5522) were evaluated. A total of 127 AMI patients underwent transthoracic echocardiography follow-up after 72 h and 6 months. Results: The rs2070950 GG genotype and rs4635799 TT genotype were most common in patients who had LV end-diastolic volume increase < 20% and the same or increased LV ejection fraction, indicating a possible protective effect of these SNPs. The rs5522 TT genotype was associated with a higher frequency of arrhythmias, while the presence of at least one rs5522 C allele was associated with a lower risk of arrhythmias. Conclusion: SNPs of the NR3C2 gene appear to correlate with better ventricular remodeling and a reduced rate of arrhythmias post-AMI, possibly by limiting the deleterious effects of cortisol on cardiomyocytes.


Assuntos
Infarto do Miocárdio , Receptores de Mineralocorticoides , Humanos , Receptores de Mineralocorticoides/genética , Remodelação Ventricular/genética , Mineralocorticoides , Hidrocortisona , Infarto do Miocárdio/genética , Arritmias Cardíacas/genética
5.
Medicina (Kaunas) ; 57(6)2021 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-34208003

RESUMO

Background and Objectives: Serum cortisol has been extensively studied for its role during acute myocardial infarction (AMI). Reports have been inconsistent, with high and low serum cortisol associated with various clinical outcomes. Several publications claim to have developed methods to evaluate cortisol activity by using elements of complete blood count with its differential. This study aims to compare the prognostic value of the cortisol index of Endobiogeny with serum cortisol in AMI patients, and to identify if the risk of mortality in AMI patients can be more precisely assessed by using both troponin I and cortisol index than troponin I alone. Materials and methods: This prospective study included 123 consecutive patients diagnosed with AMI. Diagnostic coronary angiography and revascularization was performed for all patients. Cortisol index was measured on admission, on discharge, and after 6 months. Two year follow-up for all patients was obtained. Results: Our study shows cortisol index peaks at 7-12 h after the onset of AMI, while serum cortisol peaked within 3 h from the onset of AMI. The cortisol index is elevated at admission, then significantly decreases at discharge; furthermore, the decline to its bottom most at 6 months is observed with mean values being constantly elevated. The cortisol index on admission correlated with 24-month mortality. We established combined cut-off values of cortisol index on admission > 100 and troponin I > 1.56 µg/las a prognosticator of poor outcomes for the 24-month period. Conclusions: The cortisol index derived from the global living systems theory of Endobiogeny is more predictive of mortality than serum cortisol. Moreover, a combined assessment of cortisol index and Troponin I during AMI offers more accurate risk stratification of mortality risk than troponin alone.


Assuntos
Hidrocortisona , Infarto do Miocárdio , Biomarcadores , Humanos , Infarto do Miocárdio/diagnóstico , Prognóstico , Estudos Prospectivos , Troponina I
6.
J Radiol Prot ; 36(3): 695-708, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27556787

RESUMO

Ionizing radiation management is among the most important safety issues in interventional cardiology. Multiple radiation protection measures allow the minimization of x-ray exposure during interventional procedures. Our purpose was to assess the utilization and effectiveness of radiation protection and optimization techniques among interventional cardiologists in Lithuania. Interventional cardiologists of five cardiac centres were interviewed by anonymized questionnaire, addressing personal use of protective garments, shielding, table/detector positioning, frame rate (FR), resolution, field of view adjustment and collimation. Effective patient doses were compared between operators who work with and without x-ray optimization. Thirty one (68.9%) out of 45 Lithuanian interventional cardiologists participated in the survey. Protective aprons were universally used, but not the thyroid collars; 35.5% (n = 11) operators use protective eyewear and 12.9% (n = 4) wear radio-protective caps; 83.9% (n = 26) use overhanging shields, 58.1% (n = 18)-portable barriers; 12.9% (n = 4)-abdominal patient's shielding; 35.5% (n = 11) work at a high table position; 87.1% (n = 27) keep an image intensifier/receiver close to the patient; 58.1% (n = 18) reduce the fluoroscopy FR; 6.5% (n = 2) reduce the fluoro image detail resolution; 83.9% (n = 26) use a 'store fluoro' option; 41.9% (N = 13) reduce magnification for catheter transit; 51.6% (n = 16) limit image magnification; and 35.5% (n = 11) use image collimation. Median effective patient doses were significantly lower with x-ray optimization techniques in both diagnostic and therapeutic interventions. Many of the ionizing radiation exposure reduction tools and techniques are underused by a considerable proportion of interventional cardiology operators. The application of basic radiation protection tools and techniques effectively reduces ionizing radiation exposure and should be routinely used in practice.


Assuntos
Cardiologia , Exposição Ocupacional/prevenção & controle , Lesões por Radiação/prevenção & controle , Proteção Radiológica/métodos , Radiografia Intervencionista , Humanos , Lituânia , Doses de Radiação , Radiação Ionizante , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...