1.
Curr Top Med Chem ; 1(5): 463-71, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11899108

RESUMO

We have investigated various sample chromatographic extraction and sample preparation methods for liquid chromatography mass spectrometry analysis in order to increase the throughput of various in vivo and in vitro assays in support of drug discovery. The results indicated that direct plasma injection, although certainly faster than conventional protein precipitation for sample preparation, had problems associated with column longevity and overall robustness. Frequently a single study could not be completed without column replacement. On-line solid phase extraction, on the other hand, compared well with off-line solid phase extraction, using our LC extraction column design, as contamination of the extraction column was minimized by back flushing using the Gilson syringe pump. Finally, on-line solid phase extraction for support of Caco-2 permeability studies worked very well for both single components and mixtures as the matrix was much simpler, presenting fewer contamination problems.


Assuntos
Cromatografia Líquida/métodos , Avaliação Pré-Clínica de Medicamentos/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Preparações Farmacêuticas/análise , Anti-Inflamatórios não Esteroides/análise , Antiulcerosos/análise , Anti-Hipertensivos/análise , Aspirina/análise , Células CACO-2 , Cromatografia Líquida/instrumentação , Cimetidina/análise , Avaliação Pré-Clínica de Medicamentos/instrumentação , Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Antagonistas dos Receptores Histamínicos H1/análise , Humanos , Hidroclorotiazida/análise , Inibidores de Fosfodiesterase/análise , Prometazina/análise , Teofilina/análise
2.
J Pharmacol Toxicol Methods ; 46(1): 51-5, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-12164260

RESUMO

INTRODUCTION: The aim of this investigation was to evaluate methods for increasing Caco-2 cell throughput for assessing drug intestinal absorption. The use of 6-, 12-, and 24-well membranes and the effect of membrane size on permeability and the integrity of the Caco-2 cell monolayer were assessed. In an effort to optimize the assessment of drug permeability, increased throughput was investigated by testing compounds singly or as mixtures of analytes. METHOD: The transepithelial electrical resistance (TEER) of cell monolayers was measured on 0.33, 1.0, and 4.7 cm2 polycarbonate membranes using EVOM, over a 25-day period. Absorptive transport was determined on all compounds tested using LC-MS/MS assays, or liquid scintillation spectrometry. RESULTS: The effect of multiple compounds in one well compared to single compounds was assessed with atenolol, nadolol, metoprolol, and propranolol for mixtures of four compounds and with RWJ-53308, atenolol, terbutaline, propranolol, naproxen, piroxicam, topiramate, and furosemide for mixtures of eight compounds. The apparent permeability (Papp) values correlated well between single analytes and mixtures of four and eight analytes in each well. Drug permeability decreased slightly with an increase in well size. The TEER value increased with the number of days in culture for each of the 6-, 12-, and 24-well sizes. DISCUSSION: It was demonstrated that the 24-well format system is ideal for high-throughput assessment. Furthermore, the approach of mixing four or eight analytes in each well to further increase throughput was also demonstrated to be valid.


Assuntos
Células CACO-2/metabolismo , Avaliação Pré-Clínica de Medicamentos/métodos , Absorção Intestinal/fisiologia , Preparações Farmacêuticas/metabolismo , Células CACO-2/efeitos dos fármacos , Permeabilidade da Membrana Celular/efeitos dos fármacos , Permeabilidade da Membrana Celular/fisiologia , Cromatografia Líquida , Combinação de Medicamentos , Impedância Elétrica , Humanos , Espectrometria de Massas , Membranas Artificiais , Cimento de Policarboxilato , Contagem de Cintilação
3.
J Pharm Biomed Anal ; 22(3): 469-80, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10766364

RESUMO

A rapid and reliable analytical method is described for the simultaneous determination of RWJ-38705 (tramadol N-oxide) and several of its major metabolites in the plasma of Sprague-Dawley rats and Beagle dogs. Sample preparation using solid phase extraction was followed by reversed phase liquid chromatography (LC) coupled with tandem mass spectrometric (MS/MS) detection in the positive ionization mode. The assay was linear for all analytes over concentrations ranging from approximately 6 to 2000 ng/ml. The inter-assay reproducibility was generally less than 15% while accuracy values were within 13% of theoretical. The overall recovery of the analytes ranged from approximately 40 to 64% in rat plasma and 53-75% in dog plasma. This assay has proven to be sensitive, specific and reproducible, and it has been readily implemented in preclinical PK studies. Representative plasma concentration versus time profiles resulting from administration of TNO to rats and dogs are presented in this communication.


Assuntos
Anticonvulsivantes/metabolismo , Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Tramadol/análogos & derivados , Administração Oral , Animais , Anticonvulsivantes/sangue , Anticonvulsivantes/farmacocinética , Cromatografia Líquida de Alta Pressão , Cães , Injeções Intravenosas , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Tramadol/sangue , Tramadol/metabolismo , Tramadol/farmacocinética
4.
J Chromatogr B Biomed Sci Appl ; 734(2): 247-55, 1999 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-10595722

RESUMO

A rapid and reliable analytical method is described for the simultaneous determination of a synthetic progestin norgestimate (NGM), and its metabolites, 17-deacetylnorgestimate (17-DA-NGM), 3-ketonorgestimate (3-keto-NGM) and norgestrel (NGL) in human serum using reversed phase high-performance liquid chromatography (HPLC) with tandem mass spectrometric (MS-MS) detection. The assay was linear over the concentration ranges of 0.1-5.0 ng/ml for 17-DA-NGM and NGL and 0.5-5.0 ng/ml for NGM and 3-keto-NGM. The inter-assay reproducibility was consistently less than 10%. The overall recovery of the analytes ranged from 72 to 92%. Serum profiles following oral administration of norgestimate to female volunteers are presented.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Anticoncepcionais Orais Sintéticos/sangue , Espectrometria de Massas/métodos , Norgestrel/análogos & derivados , Combinação de Medicamentos , Estabilidade de Medicamentos , Feminino , Humanos , Levanogestrel/análogos & derivados , Levanogestrel/sangue , Estrutura Molecular , Norgestrel/sangue , Oximas , Controle de Qualidade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
J Pharm Biomed Anal ; 15(6): 765-71, 1997 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9172102

RESUMO

A rapid high-performance liquid chromatographic (HPLC) method for the determination of levofloxacin in human plasma and urine has been validated. A single-step liquid-liquid extraction procedure was used to isolate levofloxacin from the biological matrix prior to quantitative analysis. The compound was separated on an Inertsil C18 reversed-phase HPLC column and quantified by measuring the UV absorbance at 330 nm. The stereospecificity was achieved in the ligand-exchange mode by incorporating chiral reagents directly into the HPLC mobile phase. Ciprofloxacin was used as the internal standard. The method was linear from 0.08 to 5.18 micrograms ml-1 of levofloxacin in plasma and from 23 to 1464 micrograms ml-1 in urine. The overall utility of the method is reflected in its high sample throughput and easy adaptability to robotic automation, thus making the procedure suitable for pharmacological and pharmacokinetic studies of levofloxacin.


Assuntos
Anti-Infecciosos/análise , Cromatografia Líquida de Alta Pressão , Levofloxacino , Ofloxacino/análise , Anti-Infecciosos/sangue , Anti-Infecciosos/urina , Estabilidade de Medicamentos , Humanos , Modelos Lineares , Ofloxacino/sangue , Ofloxacino/urina , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrofotometria Ultravioleta , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...